At least 55 records · Page 3

Improved thermoelectrically cooled quartz crystal microbalance

Design changes in the thermoelectrically-cooled quartz microbalance, which is used to monitor surface contamination in space simulation chambers, is described in terms of its extended temperature range, increased temperature control, mass sensitivity, and cooling power. The mass sensor uses 20 MHz quartz crystals having a sensitivity of 8.8 x 10 to the minus tenth power g/sq cm - Hz. The crystals are optically polished, metal plated, and overplated with magnesium fluoride to simulate an optical surface. The microbalance temperature circuitry is designed to readout and control surface temperature between 100 C and minus 59 C to plus or minus 0.5 C, and readout only temperature between minus 60 C and minus 199 C using auxiliary liquid nitrogen cooling. Data is included on the measurement of oil contamination of surfaces as a function of temperature in space simulation chambers.

D. McKeown↗

Distributed I/O Control System Implementation for the 1238 Optical Witness Sample Thermoelectric Quartz Crystal Microbalance Thermal Vacuum Bakeout Chamber

The 1238 Thermal Vacuum Bakeout Chamber is used to test materials to determine if they meet space program contamination requirements. The system was previously manual in its operation, in that there was no supervisory control system and therefore, no means for automated operation. Marshall Space Flight Center (MSFC) requested that its operation be automated. The subsequent process implemented involved a hybrid scenario that included existing hardware, a distributed input and output (I/O) system and a graphical user interface (GUI).

Randy K. Buchanan↗

Desorption characteristics of selenium and tellurium thin films

The temperature-dependent desorption behavior of selenium and tellurium is investigated using a heated quartz crystal microbalance. Prior to heating the quartz crystal microbalance, selenium and tellurium films with varying thickness were deposited using thermal effusion cells in a molecular beam epitaxy system for subsequent determination of temperature-dependent mass loss of the deposited films. The desorption rate for tellurium was found to exhibit one sharp peak around 190°C, indicating the loss of the entire film irrespective of film thickness within a temperature window of 20°C, which was completely evaporated at 200°C. Similar experiments for selenium revealed that the thermal desorption took place via a two-stage process with a smaller portion of the material desorbing within an even narrower temperature window of 5°C at a much lower peak temperature of 65°C, while most selenium desorbed within a temperature range of 10°C around 90°C. This two-stage behavior indicated the presence of at least two chemically distinct selenium species or binding states. The direct and quantitative determination of the chalcogen desorption process provides important insights into the kinetics of chalcogenide-based film growth and is in addition of applied benefit to the research community in the area of Se/Te capping and decapping of air sensitive materials as it provides temperature ranges and rates at which full desorption is achieved. Our work furthermore points toward the need for a more detailed understanding of the chemical composition state of atomic and molecular beams supplied from thermal evaporation sources during growth.

36 MATERIALS SCIENCE↗

Hubble space telescope component qualification utilizing a residual gas analyzer

An approach is described for integrating an automated residual gas analyzer (RGA) into the thermal vacuum outgas process. The RGA has the capability of detailed analysis over a 200 amu range with monitoring of each peak as the test progresses. The NASA criterion of either a 50% reduction of each peak over 44 amu or less than an 0.1% amplitude of the 28 amu base peak for all amu's above 44 amu is satisfied. A computer sorts, reports which peaks do not satisfy the criterion, and reports test completion. The computer plots amplitudes of all the peaks from 1 amu through 200 amu for each scan. This RGA real time approach is unique in that it provides sufficient detail to highlight a problem as it occurs. By comparison, a quartz crystal microbalance (QCM) or a thermoelectric quartz crystal microbalance (TQCM) indicates to the operator when changes occur, but not what has happened. Optical witness samples indicate whether a test was satisfactory within a few days after the test was completed.

Westfall, A. H.↗

Surface acoustic-wave piezoelectric crystal aerosol mass microbalance

The development of a particulate mass-sensing instrument based on a quartz-crystal microbalance and enhanced with the new surface acoustic-wave (SAW) technology is reported. Mass sensitivity comparisons of a 158-MHz SAW piezoelectric microbalance and a conventional 10-MHz quartz-crystal microbalance show that the SAW crystal is 266 times more sensitive, in good agreement with the theoretical value of 250. The frequency stability of a single SAW resonator is 6 parts in 10 to the 8th over 1 min. The response to temperature changes is found to be very linear over the range +30 to -30 C. A strong response to 15 ppm SO2 has been demonstrated on a chemically coated SAW crystal.

Bowers, W. D.↗

Accessibility and Mechanical Stability of Nanoporous Zinc Oxide and Aluminum Oxide Coatings Synthesized via Infiltration of Polymer Templates

The conformal nanoporous inorganic coatings with accessible pores that are stable under applied thermal and mechanical stresses represent an important class of materials used in the design of sensors, optical coatings, and biomedical systems. Here, we synthesize porous AlO x and ZnO coatings by the sequential infiltration synthesis (SIS) of two types of polymers that enable the design of porous conformal coatings—polymers of intrinsic microporosity (PIM) and block co-polymer (BCP) templates. Using quartz crystal microbalance (QCM), we show that alumina precursors infiltrate both polymer templates four times more efficiently than zinc oxide precursors. Using the quartz crystal microbalance (QCM) technique, we provide a comprehensive study on the room temperature accessibility to water and ethanol of pores in block copolymers (BCPs) and porous polymer templates using polystyrene-block-poly-4-vinyl pyridine (PS75-b-P4VP25) and polymers of intrinsic microporosity (PIM-1), polymer templates modified by swelling, and porous inorganic coatings such as AlO x and ZnO synthesized by SIS using such templates. Importantly, we demonstrate that no structural damage occurs in inorganic nanoporous AlO x and ZnO coatings synthesized via infiltration of the polymer templates during the water freezing/melting cycling tests, suggesting excellent mechanical stability of the coatings, even though the hardness of the inorganic nanoporous coating is affected by the polymer and precursor selections. We show that the hardness of the coatings is further improved by their annealing at 900 °C for 1 h, though for all the cases except ZnO obtained using the BCP template, this annealing has a negligible effect on the porosity of the material, as is confirmed by the consistency in the optical characteristics. These findings unravel new potential for the materials being used across various environment and temperature conditions.

36 MATERIALS SCIENCE↗

Hydrazine engine plume contamination mapping

Instrumentation for the measurement of plume exhaust specie deposition rates were developed and demonstrated. The instruments, two sets of quartz crystal microbalances, were designed for low temperature operation in the back flow and variable temperature operation in the core flow regions of an exhaust plume. These quartz crystal microbalances performed nominally, and measurements of exhaust specie deposition rates for 8400 number of pulses for a 0.1-lb monopropellant thruster are reported.

Chirivella, J. E.↗

OGO-6 gas-surface energy transfer experiment

The kinetic energy flux of the upper atmosphere was analyzed using OGO-6 data. Energy transfer between 10 microwatts/sq cm and 0.1 W/sq cm was measured by short-term frequency changes of temperature-sensitive quartz crystals used in the energy transfer probe. The condition of the surfaces was continuously monitored by a quartz crystal microbalance to determine the effect surface contamination had on energy accommodation. Results are given on the computer analysis and laboratory tests performed to optimize the operation of the energy transfer probe. Data are also given on the bombardment of OGO-6 surfaces by high energy particles. The thermoelectrically-cooled quartz crystal microbalance is described in terms of its development and applications.

Mckeown, D.↗

Molecular Layer Etching of Metalcone Films Using Lithium Organic Salts and Trimethylaluminum

Advances in semiconductor device manufacturing are limited by our ability to precisely add and remove thin layers of material in multistep fabrication processes. Recent reports on atomic layer etching (ALE) have provided the means for the precise removal of inorganic thin films deposited by atomic layer deposition (ALD), opening new avenues for nanoscale device design. Here, we report on a new technique for the precise removal of metal organic thin films deposited by molecular layer deposition (MLD), which we term molecular layer etching. This etching process employs sequential exposures of lithium organic salt (LOS) and trimethylaluminum (TMA) precursors to produce self-limiting etching behavior. We employ quartz crystal microbalance experiments to demonstrate (i) etching of alucone films preloaded with LOS upon TMA exposures and (ii) layer-by-layer etching of alucone films using alternating exposures of LOS and TMA. We also identify the selectivity of these etching mechanisms. We probe the mechanism for the layer-by-layer etching of alucone using a quartz crystal microbalance and Fourier transform infrared spectroscopy and identify that the etching proceeds via heterolytic cleaving of Al-O bonds in alucone upon LOS exposure followed by methylation to produce volatile species upon TMA exposure. The etching process results in the removal of 0.4 nm/cycle of alucone at 160 °C and up to 3.6 nm/cycle of alucone at 266 °C in ex situ etching experiments on silicon wafers. This halogen-free etching process enables etching of MLD films and provides new fabrication pathways for the control of material geometries at the nanoscale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low Energy Sputtering Experiments for Ion Engine Lifetime Assessment

The sputtering yield of molybdenum under xenon ion bombardment was measured using a Quartz Crystal Microbalance. The measurements were made for ion kinetic energies in the range 100-1keV on molybdenum films deposited by magnetron sputtering in conditions optimized to reproduce or approach bulk-like properties. SEM micrographs for different anode bias voltages during the deposition are compared, and four different methods were implemented to estimate the density of the molybdenum films. A careful discussion of the Quartz Crystal Microbalance is proposed and it is shown that this method can be used to measure mass changes that are distributed unevenly on the crystal electrode surface, if an analytical expression is known for the differential mass-sensitivity of the crystal and the erosion profile. Finally, results are presented that are in good agreement with previously published data, and it is concluded that this method holds the promise of enabling sputtering yield measurements at energies closer to the threshold energy in the very short term.

Duchemin Olivier B.↗

Particulate size distribution cascade analyzer for spacecraft contamination monitoring

A cascade particulate analyzer was developed for nearly real time measurement of the contaminating particulate size distribution in the spacecraft interior ambient environment and as a real time total impacting particulate mass monitor under vacuum conditions. The analyzer has four stages, the first stage is a basic 10 MHz quartz crystal microbalance used widely on spacecraft (such as Skylab) for contamination monitoring purposes. In this application the front sensing crystal is coated with a low vapor pressure adhesive grease which captures impacting particles. This first stage has a wide viewing angle and measures total particulate mass impacting the crystal while the unit is exposed to the vacuum environment. The remaining three states form an aerodynamic impaction cascade with individual quartz crystal microbalances at each stage acting as accumulated mass sensing elements. These three stages thus give relative mass distribution of particulates in three ranges, particles having effective diameter greater than 5 micron, particles between 1 and 5 micron diameter and particles 0.3 to 1 micron diameter.

Wallace, D. A.↗

Plasma Facing Component Characterization and Correlation With Plasma Conditions in Lithium Tokamak Experiment-β

Lithium coatings in the Lithium Tokamak eXperiment (LTX) led to flat temperature profiles. The flat temperature profiles were observed along with a hot, low density edge, implying a broad, collisionless scrape-off layer (SOL). Additionally, in vacuo X-ray photoelectron spectroscopy (XPS) measurements established that lithium coatings evaporatively deposited onto high-Z plasma facing components (PFCs) became oxidized while retaining the ability to achieve good plasma performance long after lithium was applied to the PFCs. Longstanding theory predicted flat temperature profiles with low recycling walls, which was presumed to be due to hydrogen binding with elemental lithium to form lithium hydride. The presence of oxidized lithium, however, raised questions regarding the exact mechanism of hydrogen retention in LTX. To investigate these questions, the upgraded facility LTX- β includes a new sample exposure probe (SEP) for more detailed in vacuo analysis of PFC samples. The SEP is equipped with a vacuum suitcase capable of transporting samples representative of the LTX- β outer midplane PFCs to a stand-alone XPS system while maintaining pressures lower than the LTX- β base vacuum to limit the contamination between sample exposure and analysis. The low-energy resolution XPS system used in past experiments could only enable the determination of elemental percentages on the PFC sample surfaces. Because the new XPS system has higher energy resolution, it is more direct to assign chemical compounds to the measured binding energies. This capability has been confirmed by comparing XPS data from PFC test samples with measurements using a commercial high-resolution XPS system. Quartz crystal microbalances (QCMs) were used to quantify the thickness of the deposited lithium on the LTX- β PFCs. This article describes the application of the SEP to characterize the PFC surfaces using XPS and their relationship to plasma conditions.

Maan, Anurag↗