Search NASA⌕ Search

SEARCH · Search NASA

Results for “quick”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Pin-Retraction Mechanism On Quick-Release Cover

Quick-release cover includes pin-retraction mechanism releasing cover quickly from lower of two sets of pin connections holding cover. Cover released at top by pulling lever as described in "Lever-Arm Pin Puller" (NPO-18788). Removal of cover begins when technician or robot pulls upper-pin-release lever. Cover swings downward until tabs on lower pins are pulled through slots in their receptacles. Lower pins are then free.

Macmartin, Malcolm↗

Quick Look Report of Acceleration Measurements on Mir Space Station During Mir-16

The NASA Microgravity Science and Applications Division (MSAD) sponsors the Space Acceleration Measurement System (SAMS) to support microgravity science experiments with microgravity acceleration measurements. In the past, SAMS was flown exclusively on the NASA Orbiters. MSAD is currently sponsoring science experiments participating in the Shuttle-Mir Science Program in cooperation with the Russians on the Mir space station. Included in the complement of MSAD experiments and equipment is a SAMS unit installed on the Mir space station. On 25 August 1994, the SAMS unit was launched on a Russia Progress vehicle to the Mir space station. The SAMS unit will support science experiments from the U.S. and Russia in a manner similar to the Orbiter missions by measuring the microgravity environments during the experiment operations. In October 1994, the SAMS unit recorded data on Mir for over fifty-three hours in seven different time periods to survey possible locations for future experiments. This report presents a quick look at the data and the microgravity environment during the time periods in which SAMS data were acquired. The Mir acceleration data were examined to ascertain gross attributes of the data. This report does not present an exhaustive examination of all possible activities due to the short time available to prepare this quick look report and due to the absence of complete timeline information during the SAMS recording time periods. Appendices A, B and C provide plots of the SAMS data for an overview of the microgravity environment at the times that data were recorded. Appendix D describes the procedures to access SAMS data by file transfer protocol (ftp) utilizing the internet. Appendix E contains a user comment sheet.

Delombard, Richard↗

Quick-Change Rotational Coupling

Rotational coupling designed to enable quick connection and disconnection of driving and driven components and to transmit torque without slippage. Originally designed to provide for quick adjustment of relative positions of chair and rotary motor drive for vestibular tests of human subjects in outer space. Also suitable for use in other situations in which turntables, rotating scientific instruments, or other equipment connected and disconnected frequently for adjustment or replacement. (Not suitable for replacement of permanent rotary couplings.)

Reschke, Millard F.↗

Evaluation of Mars Entry Reconstructured Trajectories Based on Hypothetical 'Quick-Look' Entry Navigation Data

A first order simulation analysis of the navigation accuracy expected from various Navigation Quick-Look data sets is performed. Here quick-look navigation data are observations obtained by hypothetical telemetried data transmitted on the fly during a Mars probe's atmospheric entry. In this simulation study, navigation data consists of 3-axis accelerometer sensor and attitude information data. Three entry vehicle guidance types are studied: I. a Maneuvering entry vehicle (as with Mars 01 guidance where angle of attack and bank angle are controlled); II. Zero angle-of-attack controlled entry vehicle (as with Mars 98); and III. Ballistic, or spin stabilized entry vehicle (as with Mars Pathfinder);. For each type, sensitivity to progressively under sampled navigation data and inclusion of sensor errors are characterized. Attempts to mitigate the reconstructed trajectory errors, including smoothing, interpolation and changing integrator characteristics are also studied.

Pastor, P. Rick↗

The Geo Quick Ride (GQR) Program: Providing Inexpensive and Frequent Access to Space

This paper examines piggybacking NASA, university, and industry payloads on commercial geosynchronous satellites. NASA's RSDO Office awarded Geo Quick Ride (GQR) study contracts in 1998 to spacecraft manufactures to examine the issues with flying secondary payloads. The study results were very promising. Commercial communication satellites have frequent flights and significant unused resources that could be used to fly secondary payloads. However, manifesting secondary payloads on a commercial revenue-generating satellite is a complex problem to solve. The solution requires multiple simultaneous approaches in order to be successful. There are business, economic, technical, schedule, and organizational issues to be resolved. This paper examines the Geo Quick Ride (GQR) concept, discusses the development issues, and describes how this concept solves many of these issues.

Caffrey, Robert↗

Quick-release connector module

A multi-bay electrical connector is described, of the type that has a frame (12, FIG. 2 ) with cavities (14) that each holds a separate module 20, which enables quick withdrawal of a single module from the frame and its quick replacement. A lock arm (42) is slidable along a first side (50) of a first cavity, and has at least one lock lug (80). A first module has a barrier part (70) that lies inward of the lock lug, which prevents outward movement of the first module out of the frame cavity. The lock arm can be moved to an unlocked position wherein the barrier part on the module lies inward of a gap (84) in the lock arm to permit the module to be pulled out of the frame cavity and later inserted therein. A latch (54) is slidable on the frame in directions (A, B) perpendicular to the sliding movement of the lock arm, and has an abutment (112, FIG. 5 ) that abuts a shoulder (114) on the lock arm to keep the lock arm in its unlocked position until the latch is released.

Sedig, Albert R.↗

High Pressure Quick Disconnect Particle Impact Tests

NASA Johnson Space Center White Sands Test Facility (WSTF) performed particle impact testing to determine whether there is a particle impact ignition hazard in the quick disconnects (QDs) in the Environmental Control and Life Support System (ECLSS) on the International Space Station (ISS). Testing included standard supersonic and subsonic particle impact tests on 15-5 PH stainless steel, as well as tests performed on a QD simulator. This paper summarizes the particle impact tests completed at WSTF. Although there was an ignition in Test Series 4, it was determined the ignition was caused by the presence of a machining imperfection. The sum of all the test results indicates that there is no particle impact ignition hazard in the ISS ECLSS QDs. KEYWORDS: quick disconnect, high pressure, particle impact testing, stainless steel

Rosales, Keisa R.↗

Reliability of a Test Battery Designed for Quickly and Safely Assessing Diverse Indices of Neuromuscular Function

Spaceflight affects nearly every physiological system. Spaceflight-induced alterations in physiological function translate to decrements in functional performance. Purpose: To develop a test battery for quickly and safely assessing diverse indices of neuromuscular performance. I. Quickly: Battery of tests can be completed in approx.30-40 min. II. Safely: a) No eccentric muscle actions or impact forces. b) Tests present little challenge to postural stability. III. Diverse indices: a) Strength: Excellent reliability (ICC = 0.99) b) Central activation: Very good reliability (ICC = 0.87) c) Power: Excellent reliability (ICC = 0.99) d) Endurance: Total work has excellent reliability (ICC = 0.99) e) Force steadiness: Poor reliability (ICC = 0.20 - 0.60) National

Spiering, Barry A.↗

Combining Quick-Turnaround and Batch Workloads at Scale

NAS uses PBS Professional to schedule and manage the workload on Pleiades, an 11,000+ node 1B cluster. At this scale the user experience for quick-turnaround jobs can degrade, which led NAS initially to set up two separate PBS servers, each dedicated to a particular workload. Recently we have employed PBS hooks and scheduler modifications to merge these workloads together under one PBS server, delivering sub-1-minute start times for the quick-turnaround workload, and enabling dynamic management of the resources set aside for that workload.

Matthews, Gregory A.↗

Probing Distinctive Redox Mechanism in Ni-Rich Cathode Via Real-Time Quick X-Ray Absorption Spectroscopy

X-ray radiation damage on the measuring system has been a critical issue regularly for a long-time exposure to X-ray beam during the in operando characterizations, which is particularly severe when the applied X-ray energy is near the absorption edges (M, L, K, etc.) of the interest element. Here, to minimize the negative effects raised by beam radiation, we employ quick X-ray absorption spectroscopy (QXAS) to study the electrochemical reaction mechanism of a Ni-rich layered structure cathode for lithium-ion batteries. With the advanced QXAS technique, the electronic structure and local coordination environment of the transition metals (TMs) are monitored in-operando with limited radiation damage. Compared to the conventional step-mode X-ray absorption spectroscopy, the QXAS can provide more reliable oxidation state change and more detailed local structure evolutions surrounding TMs (Ni and Co) in Ni-rich layered oxides. By leveraging these advantages of QXAS, we demonstrated that the Ni dominates the electrochemical process with the Co being almost electrochemically inactive. Reversible Ni ions movement between TMs sites and Li sites is also revealed by the time-resolved QXAS technique.

25 ENERGY STORAGE↗

Multi-Level Information Storage Using Engineered Electromechanical Resonances of Piezoelectric Wafers: A Concept Piezoelectric Quick Response (PQR) Code

A piezoelectric-based method for information storage is presented. It involves engineering the polarization profiles of multiple piezoelectric wafers to enhance/suppress specific electromechanical resonances. These enhanced/suppressed resonances can be used to represent multiple frequency-dependent bits, thus enabling multi-level information storage. This multi-level information storage is demonstrated by achieving three information states for a ternary encoding. Using the three information states, we present an approach to encode and decode information from a 2-by-3 array of piezoelectric wafers that we refer to as a concept Piezoelectric Quick Response (PQR) code. The scaling relation between the number of wafers used and the cumulative number of information states that can be achieved with the proposed methodology is briefly discussed. Potential applications of this methodology include tamper-evident devices, embedded product tags in manufacturing/inventory tracking, and additional layers of security with existing information storage technologies.

47 OTHER INSTRUMENTATION↗

Mounted Accelerometer Frequency Response of Adhesive Products and Aluminum Frame Quick Mounts

An accelerometer mounting technique has large implications on the frequency range and accuracy of the measurement, with stiffness and the mass relative to the monitored structure as the primary concerns. The International Organization for Standardization (ISO) gives an extensive list in 5348:2021, detailing mounting methods, and provides recommendations for testing mounts that are not specifically defined. In the nuclear industry on the laboratory scale, there is a need for vibration measurements for predictive maintenance and process monitoring that are nondestructive and capable of working in high-temperature environments. Commercial adhesive products with easy application and removal were tested as nondestructive methods, while quick mounts to a commonly used aluminum frame were tested as nondestructive and have potential applicability in high-temperature environments. The sinusoidal excitation method was used, measuring frequencies from 50 Hz to 10 kHz in one-third octave band intervals, utilizing three accelerometers and comparing the results to those obtained with the stud-mounting method. Using the lowest ±3 dB threshold across each accelerometer, foam dots and poster strips were not successful, and foam tapes were accurate up to 2000 Hz, hose clamps and zip ties up to 800 Hz, and a custom 3D printed mount up to 1000 Hz. Knowing the limitations of each mounting technique allows for accurate measurements within the appropriate range.

47 - OTHER INSTRUMENTATION↗

Ultrastructure of the green alga Dunaliella salina strain CCAP19/18 (Chlorophyta) as investigated by quick-freeze deep-etch electron microscopy

The single-celled green alga Dunaliella salina is a model system for studies on stress biology, in particular regarding secondary carotenoid accumulation. Under non-stress conditions the cells are green, but under abiotic stress the cells turn orange, because they switch their metabolism and accumulate β-Carotene in globules in the chloroplast. For the first time, Quick-freeze deep-etch electron microscopy was used to visualize cellular structures in green and orange cells of D. salina strain CCAP19/18. This allowed us to present an in-depth analysis of the cellular ultrastructure describing and comparing the features of the two cell types. Our images illustrate the presence of a pericellular matrix for this strain of D. salina. The pericellular matrix was spongy and strands of unknown material anchored it into the plasma membrane. The cytoplasm contained a variety of vesicles, vacuoles, and acidocalcisomes. We could show for strain CCAP19/18 that cytoplasmic lipid bodies were often in close proximity to and sometimes in contact with the outer chloroplast envelope membrane and with the endoplasmic reticulum. Major visible differences between green and orange cells were in the chloroplast: the orange cells have greatly reduced amounts of thylakoid membranes and greatly increased numbers of β-Carotene globules. We showed that the β-Carotene globules often made point contacts with thylakoid membranes, and frequently laid side-by-side along the thylakoid membrane surface, providing support to studies that indicated exchange of molecules between β-Carotene globules and thylakoid membranes. A unique finding was the β-Carotene globule duplets, suggesting intermediate stages in β-Carotene globule morphogenesis. Overall, the β-Carotene globules appear to be similar to plant plastoglobuli. We provide this description of the cellular ultrastructure features as a resource in the context of the recent publication of the genome of D. salina strain CCAP19/18 to expand on the knowledge regarding this novel reference strain.

59 BASIC BIOLOGICAL SCIENCES↗

Quick-connect scanning tunneling microscope head with nested piezoelectric coarse walkers

To meet changing research demands, new scanning tunneling microscope (STM) features must constantly evolve. We describe the design, development, and performance of a modular plug-in STM, which is compact and stable. The STM head is equipped with a quick-connect socket that is matched to a universal connector plug, enabling it to be transferred between systems. This head can be introduced into a vacuum system via a load-lock and transferred to various sites equipped with the connector plug, permitting multi-site STM operation. Its design allows for reliable operation in a variety of experimental conditions, including a broad temperature range, ultra-high vacuum, high magnetic fields, and closed-cycle pulse-tube cooling. The STM’s compact size is achieved by a novel nested piezoelectric coarse walker design, which allows for large orthogonal travel in the X, Y, and Z directions, ideal for studying both bulk and thin film samples ranging in size from mm to μm. Its stability and noise tolerance are demonstrated by achieving atomic resolution under ambient conditions on a laboratory desktop with no vibrational or acoustic isolation. The operation of the nested coarse walkers is demonstrated by successful navigation to a μm-sized 2D sample.

Instruments & Instrumentation↗

Quick Guide for SNS-NSE Reduction Software DrSpine (Data Reduction for Spin Echo)

This is a general guide to quick access the most common commands for DrSpine (Data Reduction for Spin Echo) data reduction software of the SNS-NSE spectrometer. Over the length of the manuscript the symbol “ $ “ represents the OS shell prompt, i.e., the beginning of a command line in a shell terminal, while the symbol “-->” represents the beginning of a command line in the DrSpine reduction software, after the activation of the reduction environment.

97 MATHEMATICS AND COMPUTING↗