Search NASA⌕ Search

SEARCH · Search NASA

Results for “racking test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Sidewall Breach During Lithium-Ion Battery Thermal Runaway Triggered by Cell-to-Cell Propagation Visualized Using High-Speed X-Ray Imaging

With the rapid deployment of Li-ion batteries (LiBs) in a range of applications, it is crucial to ensure their safe operation. Therefore, it is necessary to investigate the rapid thermal runaway failure that LiBs can undergo if improperly operated or subjected to abuse scenarios so that hazardous events can be avoided or mitigated. Sidewall breaches or ruptures of LiBs during thermal runaway are considered the most hazardous failure scenario, resulting in hot abrasive flare from the casing of the cell that can impinge on neighbouring cells and lead to the propagation of thermal runaway throughout a battery pack. Yet, the process leading up to the sidewall breach is not well understood due to the extreme difficulty in visualizing such a failure in commercially relevant cells. With the application of a newly developed chamber for remote-controlled abuse testing of batteries coupled with simultaneous X-ray imaging, we demonstrate here for the first time an in-situ visualization of a sidewall breach. By further applying spatiotemporal mapping techniques, the internal thermal runaway events leading up to the sidewall breach can be analyzed in detail. Subsequently, the speed of the electrode layer delamination could be calculated to a speed of 0.6 m/s. These new insights bring more clarity regarding this phenomenon, that in turn can help battery designers improve battery safety.

battery safety↗

In situ chamber for studying battery failure using high-speed synchrotron radiography

The investigation of lithium-ion battery failures is a major challenge for personnel and equipment due to the associated hazards (thermal reaction, toxic gases and explosions). To perform such experiments safely, a battery abuse-test chamber has been developed and installed at the microtomography beamline ID19 of the European Synchrotron Radiation Facility (ESRF). The chamber provides the capability to robustly perform in situ abuse tests through the heat-resistant and gas-tight design for flexible battery geometries and configurations, including single-cell and multi-cell assemblies. High-speed X-ray imaging can be complemented by supplementary equipment, including additional probes (voltage, pressure and temperature) and thermal imaging. Together with the test chamber, a synchronization graphical user interface was developed, which allows an initial interpretation by time-synchronous visualization of the acquired data. Enabled by this setup, new meaningful insights can be gained into the internal processes of a thermal runaway of current and future energy-storage devices such as lithium-ion cells.

25 ENERGY STORAGE↗

CCG-Flasks Instrument Handbook

Surface-based sampling Samples are collected from the one of the two 60m inlet in the PGS shed. A site technician triggers sampling, usually at 2pm local time, every Thursday. Eacl flask (2.5liters) is sampled for about 2 minutes and pressurized to 40 PSI. This system automatically purges the flasks, dries the air sample, and fills the flasks. Aircraft-based sampling Samples are collected from the community inlet for as many as twelve elevations. The pilot triggers sampling when location and latitude have been reached. Each flask (0.75 liters) is sampled for about 2 minutes and pressurized to 40 PSI. The sampler has two components: (1) a rack mounted programmable compressor package (PCP, see picture below) and (2) a programmable flask package (PFP). Prior each flight, the pilot connects a new PFP to the PCP. An automatic test is then performed to check for leaks. After each flight the PFP is sent back to the laboratory for analysis of trace gases.

47 OTHER INSTRUMENTATION↗

Spectrometer for Sky-Scanning Sun-Tracking Atmospheric Research (4STAR): Instrument Technology

The Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research (4STAR) combines airborne sun tracking and sky scanning with diffraction spectroscopy, to improve knowledge of atmospheric constituents and their links to air-pollution/climate. Direct beam hyper-spectral measurement of optical depth improves retrievals of gas constituents and determination of aerosol properties. Sky scanning enhances retrievals of aerosol type and size distribution. 4STAR measurements will tighten the closure between satellite and ground-based measurements. 4STAR incorporates a modular sun-tracking/ sky-scanning optical head with fiber optic signal transmission to rack mounted spectrometers, permitting miniaturization of the external optical head, and future detector evolution. Technical challenges include compact optical collector design, radiometric dynamic range and stability, and broad spectral coverage. Test results establishing the performance of the instrument against the full range of operational requirements are presented, along with calibration, engineering flight test, and scientific field campaign data and results.

atmosphere↗

Tracking Internal Temperature and Structural Dynamics during Nail Penetration of Lithium-Ion Cells

Mechanical abuse of lithium-ion batteries is widely used during testing to induce thermal runaway, characterize associated risks, and expose cell and module vulnerabilities. But, the repeatability of puncture or 'nail penetration' tests is a key issue as there is often a high degree of variability in the resulting thermal runaway process. Here, the failure mechanisms of 18650 cells punctured at different locations and orientations are characterized with respect to their internal structural degradation, and both their internal and surface temperature, all of which are monitored in real time. The initiation and propagation of thermal runaway is visualized via high-speed synchrotron X-ray radiography at 2000 frames per second, and the surface and internal temperatures are recorded via infrared imaging and a thermocouple embedded in the tip of the penetrating nail, respectively. The influence of the nail, as well as how and where it penetrates the cell, on the initiation and propagation of thermal runaway is described and the suitability of this test method for representing in-field failures is discussed.

25 ENERGY STORAGE↗

Environmental Baseline Survey for Proposed Land Use Permit Modification for Expansion of the Dynamic Explosive Test Site (DETS) 9940 Main Complex Parking Lot.

The approach was to perform a document search, supplemented by a visual site inspection, to identify potential environmental contamination associated with the property. Factors evaluated included hazardous substances; petroleum products and derivatives; environmental restoration sites; areas of concern; storage tanks; oil/water separators; grease traps; wash racks; waste tanks; pesticides; military munitions/ordnance; medical or bio-hazardous waste; radioactive waste; solid/municipal waste; indoor air quality; groundwater; wastewater treatment, collection, and disposal/discharge; drinking water quality; utilities; asbestos; polychlorinated biphenyls (PCBs); radon; lead-based paint; cultural resources; floodplains; and natural/biological resources.

54 ENVIRONMENTAL SCIENCES↗

NSLS-II RF BEAM POSITION MONITOR

An internal R&D program has been undertaken at BNL to develop a sub-micron RF Beam Position Monitor (BPM) for the NSLS-II 3rd generation light source that is currently under construction. The BPM R&D program started in August 2009. Successful beam tests were conducted 15 months from the start of the program. The NSLS-II RF BPM has been designed to meet all requirements for the NSLS-II Injection system and Storage Ring. Housing of the RF BPM's in +-0.1 C thermally controlled racks provide sub-micron stabilization without active correction. An active pilot-tone has been incorporated to aid long-term (8hr min) stabilization to 200nm RMS. The development of a sub-micron BPM for the NSLS-II has successfully demonstrated performance and stability. Pilot Tone calibration combiner and RF synthesizer has been implemented and algorithm development is underway. The program is currently on schedule to start production development of 60 Injection BPM's starting in the Fall of 2011. The production of {approx}250 Storage Ring BPM's will overlap the Injection schedule.

43 PARTICLE ACCELERATORS↗

Liquid Cooling in Data Centers

Semiconductor manufacturers have aggressively attacked the problem of escalating microprocessor power consumption levels. Today, server manufacturers can purchase microprocessors that currently have power consumption levels capped at 100W maximum. However, total server power levels continue to increase, with the increase in power consumption coming from the supportin chipsets, memory, and other components. In turn, full rack heat loads are very aggressivley climbing as well, and this is making it increasingly difficult and cost-prohibitive for facility owners to cool these high power racks. As a result, facilities owners are turning to alternative, and more energy efficient, cooling solutions that deploy liquids in one form or another. The paper discusses the advent of the adoption of liquid-cooling in high performance computing centers. An overview of the following competing rack-based, liquid-cooling, technologies is provided: in-row, above rack, refrigerated/enclosed rack, rear door heat exchanger, and device-level (i.e., chip-level). Preparation for a liquid-cooled data center, retroft and greenfield (new), is discussed, with a focus on the key issues that are common to all liquid-cooling technologies that depend upon the delivery of water to the rack (or in some deployments, a Coolant Distribution Unit). The paper then discusses, in some detail, the actual implementation and deployment of a liquid device-level cooled (spray cooled) supercomputer at the Pacific Northwest National Laboratory. Initial results from a successful 30 day compliance test show excellent hardware stability, operating system (OS) and software stack stability, application stability and performance, and an availability level that exceeded expectations at 99.94%. The liquid-cooled supercomputer achieved a peak performance of 9.287 TeraFlops, which placed it at number 101 in the June 2007 Top500 fastest supercomputers worldwide. Long-term performance and energy efficiency testing is currently underway, and detailed results will be reported in upcoming publications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Diffraction and Transmission Synchrotron Imaging at the German Light Source ANKA--Potential Industrial Applications

Diffraction and transmission synchrotron imaging methods have proven to be highly suitable for investigations in materials research and non-destructive evaluation. The high flux and spatial coherence of X-rays from modern synchrotron light sources allows one to work using high resolution and different contrast modalities. This article gives a short overview of different transmission and diffraction imaging methods with high potential for industrial applications, now available for commercial access via the German light source ANKA (Forschungszentrum Karlsruhe) and its new department ANKA Commercial Service (ANKA COS, http://www.anka-cos.de)

36 MATERIALS SCIENCE↗

Analog Signal Multiplexing System for the Iota Proton Injector

The Fermilab Accelerator Science and Technology (FAST) Facility at FNAL is a dedicated research and development center focused on advancing particle accelerator technologies for future applications worldwide. Currently, a key objective of FAST Operations is to commission the 2.5 MeV IOTA Proton Injector (IPI) and enable proton injection into the Integrable Optics Test Accelerator (IOTA) storage ring. The low and medium-energy sections of the IPI include four frame-style dipole trims and two multi-function correctors with independently controlled coils, requiring readout of 32 analog channels for current and voltage monitoring in total. To reduce cost and optimize rack space within the PLC-based control system, a 32-to-4 analog signal multiplexing system was designed and implemented. This system enables real-time readback of excitation parameters from all magnetic correctors. This paper presents the design, construction, implementation, and performance of the multiplexing system.

MacLean, Daniel R. [Fermilab] (ORCID:0000000210103↗

Experimental quantification of the background neutron flux in the Advanced Test Reactor fuel storage canal - 25562

The Advanced Test Reactor at the Idaho National Laboratory is one of only a few high-power, versatile, research reactors of its type in the world. The ATR fuel storage canal features a gamma irradiation facility that has various uses as well. It is composed of a simple dry tube that extends down into one of the fuel storage rack positions. This tube is surrounded by used fuel elements that can be selected from the inventory to produce the desired gamma radiation level and, to some extent, spectrum within the dry tube. The gamma field within the dry tube is accompanied by a small background neutron flux, produced primarily by photoneutron production in the small fraction of heavy water (D{sub 2}O) that is naturally present in light water. Neutron activation spectrometry was employed to quantify the background neutron flux in the dry tube in a configuration where the gamma exposure rate was approximately 5x10{sup 6} Roentgens per hour. The measurement technique used is very sensitive and provided self-consistent results in terms of raw activation data quality. The background neutron fluxes in the gamma facility were very low, but still detectable. The total neutron flux in the energy region above 0.414 eV and the thermal neutron flux (below 0.414 eV) were estimated from the activation measurements to be 7.5x10{sup 2} and 1.0x10{sup 2} n/cm{sup 2}-s, respectively. High uncertainties (factors of approximately 20-30% in the above-thermal range and 100% in the thermal range) apply to these results. These high uncertainties are primarily due to the limited number of activation interactions that could be used to detect such small fluxes and the resulting propagation of uncertainties associated with the various input parameters involved in the spectral unfolding process. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analog Signal Multiplexing System for the IOTA Proton Injector

he Fermilab Accelerator Science and Technology (FAST) Facility at FNAL is a dedicated research and development center focused on advancing particle accelerator technologies for future applications worldwide. Currently, a key objective of FAST Opera-tions is to commission the 2.5 MeV IOTA Proton Injec-tor (IPI) and enable proton injection into the Integrable Optics Test Accelerator (IOTA) storage ring. The low and medium-energy sections of the IPI include four frame-style dipole trims and two multi-function cor-rectors with independently controlled coils, requiring readout of 32 analog channels for current and voltage monitoring in total. To reduce cost and optimize rack space within the PLC-based control system, a 32-to-4 analog signal multiplexing system was designed and implemented. This system enables real-time readback of excitation parameters from all magnetic correctors. This paper presents the design, construction, implementation, and performance of the multiplexing system.

MacLean, Daniel R. [Fermilab] (ORCID:0000000210103↗

Performance Comparison of Four SolarWorld Module Technologies at the US DOE Regional Test Center in New Mexico: November 2016 - March 2017.

This report provides a preliminary (three month) analysis for the SolarWorld system installed at the New Mexico Regional Test Center (RTC.) The 8.7kW, four-string system consists of four module types): bifacial, mono-crystalline, mono-crystalline glass-glass and polycrystalline. Overall, the SolarWorld system has performed well to date: most strings closely match their specification-sheet module temperature coefficients and Sandia 's f lash tests show that Pmax values are well within expectations. Although the polycrystalline modules underperformed, the results may be a function of light exposure, as well as mismatch within the string, and not a production flaw. The instantaneous bifacial gains for SolarWorld 's Bisun modules were modest but it should be noted that the RTC racking is not optimized for bifacial modules, nor is albedo optimized at the site. Additional analysis, not only of the SolarWorld installation in New Mexico but of the SolarWorld installations at the Vermont and Florida RTCs will be provide much more information regarding the comparative performance of the four module types.

14 SOLAR ENERGY↗

Examination of an Electrified Bar Rack Fish Guidance Device for Hydropower Turbines

The potential of hydropower turbines to cause injury or mortality to fish is a concern. To reduce this risk, engineers have begun to develop a conically arranged, cantilevered electrified bar rack (Center Sender). This device is proposed to be mounted within the intake of a turbine, guiding downstream-passing fish towards the center of the turbine where blade velocities are lower and blades are thicker, likely reducing the potential for fish to be injured. A simplified version was installed in a flume for testing with Rainbow trout (Oncorhynchus mykiss) while examining several parameters such as electrification, bar spacing, bar angle, and water velocity. The most effective settings were observed to be a water velocity of 1.0 m s -1 with all bars installed at an angle of 40° with electrification on. Other combinations were still effective but had varying results. A minimal proportion (2.3%) of fish passed at lower velocities with bars electrified and mounted at 20°, suggesting that while it functions well as a guidance device in high-velocity conditions, it performs better as a barrier at lower velocities. The study suggests that the Center Sender has promising potential for reducing the harmful effects of hydropower turbines on fish populations by guiding them away from stressors. Further research is needed, but current results encourage its potential use in hydropower operations.

13 HYDRO ENERGY↗

A Micro-Thermionic Ionization Source for Chemical Detection

The major goal of this project was to develop an ionization-based detector that could be integrated into the portable gas chromatography systems currently produced by Defiant Technologies. This new detector would allow Defiant to analyze a broader range of analytes and enter new markets. There was also an interest in testing the new ionization source in an ion mobility spectrometer (IMS) that is produced by Sandia National Laboratories. Not only could this eliminate the need for a radioactive material in the IMS, it would offer Defiant the opportunity to add a whole new product line to their chemical analysis systems. Significant progress was made in the development of a thermionic ionization source (TIS) and detector. Using a MEMs heater was an attractive concept, but it proved to be an unfruitful approach because of the fragility of the devices at elevated temperatures. A rugged alternative heater was developed using nichrome wire and alumina tubes. These heaters are simple to make, and, for low quantity production, will be considerably cheaper to construct than MEMs devices. This work has provided a firm basis for follow-on projects. There is now a solid concept for constructing heater elements where, prior to this work, there was only the hope that MEMs heaters would work. In addition, the electrometer that was developed works better than the commercial rack-mounted system that was originally used in this study. Overcoming these two obstacles provides a clear technical approach for product development. There will be follow on efforts at Defiant Technologies to refine the development of the thermal ionization detector. Designs are being made to combine the TIS and electrometer electronics into a single package with a simple-to-replace TIS element. Further work will also focus on integrating this new detector into portable gas chromatography products and testing to optimize the performance.

47 OTHER INSTRUMENTATION↗

Thermal Management for FPGA Nodes in HPC Systems

The integration of FPGAs into large-scale computing systems is gaining attention. In these systems, real-time data handling for networking, tasks for scientific computing, and machine learning can be executed with customized datapaths on reconfigurable fabric within heterogeneous compute nodes. At the same time, thermal management, particularly battling the cooling cost and guaranteeing the reliability, is a continuing concern. The introduction of new heterogeneous components into HPC nodes only adds further complexities to thermal modeling and management. The thermal behavior of multi-FPGA systems deployed within large compute clusters is less explored. Here, we first show that the thermal behaviors of different FPGAs of the same generation can vary due to their physical locations in a rack and process variation, even though they are running the same tasks. We present a machine learning–based model to capture the thermal behavior of each individual FPGA in the cluster. We then propose two thermal management strategies guided by our thermal model. First, we mitigate thermal variation and hotspots across the cluster by proactive thermal-aware task placement. Under the tested system and benchmarks, we achieve up to 26.4° C and on average 13.3° C system temperature reduction with no performance penalty. Second, we utilize this thermal model to guide HLS parameter tuning at the task design stage to achieve improved thermal response after deployment.

97 MATHEMATICS AND COMPUTING↗