Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiation source detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Time Series Evaluation of Radiation Portal Monitor Data for Point Source Detection

The time series of data from a Radiation Portal Monitor (RPM) system are evaluated for the presence of point sources by isolating the contribution of anomalous radiation. Energy-windowed background spectra taken from the RPM are compared with the observed spectra at each time step during a vehicle drive-through. The total signal is turned into a spectral distance index using this method. This provides a time series with reduced systematic fluctuations due to background attenuation by the vehicle, and allows for point source detection by time-series analyses. The anomalous time series is reanalyzed by using a wavelet filter function of similar size to the expected source profile. A number of real drive-through data sets taken at a U.S. port of entry are analyzed in this way. A set of isotopes are injected into the data set, and the resultant benign and injected data sets are analyzed with gross-counting, spectral-ratio, and time-based algorithms. Spectral and time methods together offer a significant increase to detection performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Backscatter x-ray development for space vehicle thermal protection systems

The Backscatter X-Ray (BSX) imaging technique is used for various single sided inspection purposes. Previously developed BSX techniques for spray-on-foam insulation (SOFI) have been used for detecting defects in Space Shuttle External Tank foam insulation. The developed BSX hardware and techniques are currently being enhanced to advance Non-Destructive Evaluation (NDE) methods for future space vehicle applications. Various Thermal Protection System (TPS) materials were inspected using the enhanced BSX imaging techniques, investigating the capability of the method to detect voids and other discontinuities at various locations within each material. Calibration standards were developed for the TPS materials in order to characterize and develop enhanced BSX inspection capabilities. The ability of the BSX technique to detect both manufactured and natural defects was also studied and compared to through-transmission x-ray techniques. The energy of the x-ray, source to object distance, angle of x-ray, focal spot size and x-ray detector configurations were parameters playing a significant role in the sensitivity of the BSX technique to image various materials and defects. The image processing of the results also showed significant increase in the sensitivity of the technique. The experimental results showed BSX to be a viable inspection technique for space vehicle TPS systems.

07 ISOTOPE AND RADIATION SOURCES↗

Nuisance Source Population Modeling for Radiation Detection System Analysis

A major challenge facing the prospective deployment of radiation detection systems for homeland security applications is the discrimination of radiological or nuclear 'threat sources' from radioactive, but benign, 'nuisance sources'. Common examples of such nuisance sources include naturally occurring radioactive material (NORM), medical patients who have received radioactive drugs for either diagnostics or treatment, and industrial sources. A sensitive detector that cannot distinguish between 'threat' and 'benign' classes will generate false positives which, if sufficiently frequent, will preclude it from being operationally deployed. In this report, we describe a first-principles physics-based modeling approach that is used to approximate the physical properties and corresponding gamma ray spectral signatures of real nuisance sources. Specific models are proposed for the three nuisance source classes - NORM, medical and industrial. The models can be validated against measured data - that is, energy spectra generated with the model can be compared to actual nuisance source data. We show by example how this is done for NORM and medical sources, using data sets obtained from spectroscopic detector deployments for cargo container screening and urban area traffic screening, respectively. In addition to capturing the range of radioactive signatures of individual nuisance sources, a nuisance source population model must generate sources with a frequency of occurrence consistent with that found in actual movement of goods and people. Measured radiation detection data can indicate these frequencies, but, at present, such data are available only for a very limited set of locations and time periods. In this report, we make more general estimates of frequencies for NORM and medical sources using a range of data sources such as shipping manifests and medical treatment statistics. We also identify potential data sources for industrial source frequencies, but leave the task of estimating these frequencies for future work. Modeling of nuisance source populations is only useful if it helps in understanding detector system performance in real operational environments. Examples of previous studies in which nuisance source models played a key role are briefly discussed. These include screening of in-bound urban traffic and monitoring of shipping containers in transit to U.S. ports.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Metrics and Methods for Radiation Detection Algorithm Characterization for Nuclear/Radiological Source Search

This report presents a series of recommendations for data to train and evaluate radiation detection algorithms and performance metrics to evaluate these algorithms. These recommendations were formed through a community consensus approach through the Detection Radiation Algorithms Group (DRAG), a multi-institution collaboration spanning eight Department of Energy laboratories and John Hopkins Applied Physics Laboratory. This report includes recommendations on background data variability, and metrics to quantify variability, sources and shielding configurations to include in data collection campaigns and detector response variability. In addition, this report describes several anomaly detection and identification algorithms and recommends metrics to report their performance. Finally, this report ends with a discussion on machine learning algorithms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Millimeter wave detection of nuclear radiation: An alternative detection mechanism

We present a nuclear radiation detection mechanism using millimeter waves as an alternative to conventional detection. It is based on the concept that nuclear radiation causes ionization of air and that if we place a dielectric material near the radiation source, it acts as a charge accumulator of the air ions. We have found that millimeter waves can interrogate the charge cloud on the dielectric material remotely. This concept was tested with a standoff millimeter wave system by monitoring the charge levels on a cardboard tube placed in an x-ray beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Range, resolution and power of THz systems for remote detection of concealed radioactive materials

This paper analyzes parameters required for realizing remote detection of a concealed source of ionizing radiation by observing the occurrence of breakdown in air by a focused wave beam. Production of free electrons and the free electron density in the absence/presence of additional sources of ionization are analyzed. The maximum electron density in the discharge and the time required for this density to return after the discharge back to its stationary level, are estimated. The optimal excess of the power density and the corresponding power level as the function of frequency are determined. It is shown that the optimal frequency of such systems ranges from 0.3 up to 0.8 THz. The paper also determines the range of such systems as the function of the source frequency and power and contains a brief analysis of available sources of microwave, millimeter-wave and THz radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inelastic partial {gamma}-ray cross sections of {sup 150}Sm+n reactions for E{sub n} = 1-15 MeV

The {sup 150}Sm(n,n'{gamma}) reaction was measured from E{sub n} = 1 to 15 MeV at the Los Alamos Neutron Science Cemter (LANSCE). The {gamma} rays were detected with the Compton-suppressed Germanium Array for Neutron Induced Excitations (GEANIE). Measured {gamma}-ray excitation functions were converted to partial {gamma}-ray cross sections, Twenty four individual {gamma}-rays up to E{sub x} = 1.8 MeV in {sup 150}Sm were measured. Results are compared with enhanced Hauser Feshbach model calculations: the spin distribution in the pre-equilibrium reaction is calculated with the quantum mechanical model of Feshbach, Kerman and Koonin. The particle transmission coefficients were calculated with two different global optical model potential parameter sets. We employed the coupled-channel optical model based on the soft rotor model and with spherical potential.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Omniscopes: Large area telescope arrays with only NlogN computational cost

We show that the class of antenna layouts for telescope arrays allowing cheap analysis hardware (with correlator cost scaling as NlogN rather than N{sup 2} with the number of antennas N) is encouragingly large, including not only previously discussed rectangular grids but also arbitrary hierarchies of such grids, with arbitrary rotations and shears at each level. We show that all correlations for such a 2D array with an n-level hierarchy can be efficiently computed via a fast Fourier transform in not two but 2n dimensions. This can allow major correlator cost reductions for science applications requiring exquisite sensitivity at widely separated angular scales, for example, 21 cm tomography (where short baselines are needed to probe the cosmological signal and long baselines are needed for point source removal), helping enable future 21 cm experiments with thousands or millions of cheap dipolelike antennas. Such hierarchical grids combine the angular resolution advantage of traditional array layouts with the cost advantage of a rectangular fast Fourier transform telescope. We also describe an algorithm for how a subclass of hierarchical arrays can efficiently use rotation synthesis to produce global sky maps with minimal noise and a well-characterized synthesized beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detectable gravitational radiation from stellar collapse

The problem of astrophysical sources of detectable gravitational radiation is considered from the stellar-evolution viewpoint. Calculations are presented which indicate that the final stages of evolution may well be dominated by rapidly rotating, collapsing cores which develop nonaxisymmetric configurations. Such events emit large amounts of gravitational radiation which should be detectable in the near future.

Endal, A. S.↗

Hypothesis tests for the detection of constant speed radiation moving sources

Radiation Portal Monitors are deployed in linear network to detect radiological material in motion. As a complement to single and multichannel detection algorithms, inefficient under too low signal to noise ratios, temporal correlation algorithms have been introduced. Test hypothesis methods based on empirically estimated mean and variance of the signals delivered by the different channels have shown significant gain in terms of a tradeoff between detection sensitivity and false alarm probability. This paper discloses the concept of a new hypothesis test for temporal correlation detection methods, taking advantage of the Poisson nature of the registered counting signals, and establishes a benchmark between this test and its empirical counterpart. The simulation study validates that in the four relevant configurations of a pedestrian source carrier under respectively high and low count rate radioactive background, and a vehicle source carrier under the same respectively high and low count rate radioactive background, the newly introduced hypothesis test ensures a significantly improved compromise between sensitivity and false alarm, while guaranteeing the stability of its optimization parameter regardless of signal to noise ratio variations between 2 to 0.8. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Edge-enhanced imaging obtained with very broad energy band x-rays

We demonstrate both theoretically and experimentally that edge-enhancement effects are produced when objects, in contact with the x-ray detector, are imaged by using very broad x-ray spectra. Radiographs of thin Al objects have been obtained with a table-top synchrotron source which generates x-rays in the energy range from a few kilo-electron-volts up to 6 MeV. Edge-enhancement effects arise from the combination of x-ray absorption (kilo-electron-volt part of the spectrum) and secondary particle emission (mega-electron-volt part of the spectrum) within the sample. The exact contribution of absorption and emission profiles in the edge-enhanced images has been calculated via Monte Carlo simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NEAR-INFRARED PROPERTIES OF THE X-RAY-EMITTING YOUNG STELLAR OBJECTS IN THE CARINA NEBULA

The Great Nebula in Carina (NGC 3372) is the best target to study in detail the process of violent massive star formation and the resulting feedback effects of cloud dispersal and triggered star formation. While the population of massive stars is rather well studied, the associated low-mass stellar population was largely unknown up to now. The near-infrared study in this paper builds on the results of the Chandra Carina Complex Project, that detected 14,368 X-ray sources in the 1.4 deg{sup 2} survey region, an automatic source classification study that classified 10,714 of these X-ray sources as very likely young stars in Carina, and an analysis of the clustering properties of the X-ray-selected Carina members. In order to determine physical properties of the X-ray-selected stars, most of which were previously unstudied, we used HAWK-I at the ESO Very Large Telescope to conduct a very deep near-IR survey with subarcsecond angular resolution, covering an area of about 1280 arcmin{sup 2}. The HAWK-I images reveal more than 600,000 individual infrared sources, whereby objects as faint as J {approx} 23, H {approx} 22, and K{sub s} {approx} 21 are detected at signal-to-noise ratio (S/N) {>=}3. While less than half of the Chandra X-ray sources have counterparts in the Two Micron All Sky Survey catalog, the {approx}5 mag deeper HAWK-I data reveal infrared counterparts to 6636 (=88.8%) of the 7472 Chandra X-ray sources in the HAWK-I field. We analyze near-infrared color-color and color-magnitude diagrams to derive information about the extinctions, infrared excesses (as tracers for circumstellar disks), ages, and masses of the X-ray-selected objects. The near-infrared properties agree well with the results of the automatic X-ray source classification, showing that the remaining contamination in the X-ray-selected sample of Carina members is very low ({approx}<7%). The shape of the K-band luminosity function of the X-ray-selected Carina members agrees well with that derived for the Orion Nebula Cluster, suggesting that, down to the X-ray detection limit around 0.5-1 M{sub sun}, the shape of the initial mass function (IMF) in Carina is consistent with that in Orion (and thus the field IMF). The fraction of stars with near-infrared excesses is rather small, {approx}<10%, but shows considerable variations between individual parts of the complex. The distribution of extinctions for the diskless stars ranges from {approx}1.6 mag to {approx}6.2 mag (central 80th percentile), clearly showing a considerable range of differential extinction between individual stars in the complex.

79 ASTRONOMY AND ASTROPHYSICS↗

Device and method for locating a radiation emitting source via angular dependence using a single detection crystal

A device for sensing, locating, and characterizing a radiation emitting source, including: a detection crystal having dimensions great enough such that regional differences in radiation response are generated in the detection crystal by radiation impinging on one or more surfaces of the detection crystal; and a plurality of detectors one or more of coupled to and disposed on a plurality of surfaces of the detection crystal operable for detecting the regional differences in radiation response generated in the detection crystal by the radiation impinging on the one or more surfaces of the detection crystal.

36 MATERIALS SCIENCE↗

A PAN-CARINA YOUNG STELLAR OBJECT CATALOG: INTERMEDIATE-MASS YOUNG STELLAR OBJECTS IN THE CARINA NEBULA IDENTIFIED VIA MID-INFRARED EXCESS EMISSION

We present a catalog of 1439 young stellar objects (YSOs) spanning the 1.42 deg{sup 2} field surveyed by the Chandra Carina Complex Project (CCCP), which includes the major ionizing clusters and the most active sites of ongoing star formation within the Great Nebula in Carina. Candidate YSOs were identified via infrared (IR) excess emission from dusty circumstellar disks and envelopes, using data from the Spitzer Space Telescope (the Vela-Carina survey) and the Two-Micron All Sky Survey. We model the 1-24 {mu}m IR spectral energy distributions of the YSOs to constrain physical properties. Our Pan-Carina YSO Catalog (PCYC) is dominated by intermediate-mass (2 M{sub sun} < m {approx}< 10 M{sub sun}) objects with disks, including Herbig Ae/Be stars and their less evolved progenitors. The PCYC provides a valuable complementary data set to the CCCP X-ray source catalogs, identifying 1029 YSOs in Carina with no X-ray detection. We also catalog 410 YSOs with X-ray counterparts, including 62 candidate protostars. Candidate protostars with X-ray detections tend to be more evolved than those without. In most cases, X-ray emission apparently originating from intermediate-mass, disk-dominated YSOs is consistent with the presence of low-mass companions, but we also find that X-ray emission correlates with cooler stellar photospheres and higher disk masses. We suggest that intermediate-mass YSOs produce X-rays during their early pre-main-sequence evolution, perhaps driven by magnetic dynamo activity during the convective atmosphere phase, but this emission dies off as the stars approach the main sequence. Extrapolating over the stellar initial mass function scaled to the PCYC population, we predict a total population of >2 x 10{sup 4} YSOs and a present-day star formation rate (SFR) of >0.008 M{sub sun} yr{sup -1}. The global SFR in the Carina Nebula, averaged over the past {approx}5 Myr, has been approximately constant.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulations of X-Ray Telescopes for eROSITA and IXO

We report on the development of a generic X-ray instrument simulator to be used in simulations of future X-ray missions. Based on a Monte Carlo approach the code generates photon events for sources in an X-ray source catalogue such as the ROSAT all sky survey or the XMM-Newton slew surveys and then models the imaging and detection process based on the available calibration files (e.g., point spread functions for the imaging). The output of the program are event lists, which can be analysed using standard software such as xselect. Due to its modular concept the simulation software can be easily adapted to different concepts of imaging detectors.As examples for the potential use of the simulation we present our studies for eROSITA and show results of simulations of the detector performance for the High Time Resolution Spectrometer and the Wide Field Imager on the International X-ray Observatory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data Fusion for a Vision-Radiological System for Source Tracking and Discovery

A multidisciplinary approach to allow the tracking of the movement of radioactive sources by fusing data from multiple radiological and visual sensors is under development. The goal is to improve the ability to detect, locate, track and identify nuclear/radiological threats. The key concept is that such widely available visual and depth sensors can impact radiological detection, since the intensity fall-off in the count rate can be correlated to movement in three dimensions. To enable this, we pose an important question; what is the right combination of sensing modalities and vision algorithms that can best compliment a radiological sensor, for the purpose of detection and tracking of radioactive material? Similarly what is the best radiation detection methods and unfolding algorithms suited for data fusion with tracking data? Data fusion of multi-sensor data for radiation detection have seen some interesting developments lately. Significant examples include intelligent radiation sensor systems (IRSS), which are based on larger numbers of distributed similar or identical radiation sensors coupled with position data for network capable to detect and locate radiation source. Other developments are gamma-ray imaging systems based on Compton scatter in segmented detector arrays. Similar developments using coded apertures or scatter cameras for neutrons have recently occurred. The main limitation of such systems is not so much in their capability but rather in their complexity and cost which is prohibitive for large scale deployment. Presented here is a fusion system based on simple, low-cost computer vision and radiological sensors for tracking of multiple objects and identifying potential radiological materials being transported or shipped. The main focus of this work is the development on two separate calibration algorithms for characterizing the fused sensor system. The deviation from a simple inverse square-root fall-off of radiation intensity is explored and accounted for. In particular, the computer vision system enables a map of distance-dependence of the sources being tracked. Infrared, laser or stereoscopic vision sensors are all options for computer-vision implementation depending on interior vs exterior deployment, resolution desired and other factors. Similarly the radiation sensors will be focused on gamma-ray or neutron detection due to the long travel length and ability to penetrate even moderate shielding. There is a significant difference between the vision sensors and radiation sensors in the way the 'source' or signals are generated. A vision sensor needs an external light-source to illuminate the object and then detects the re-emitted illumination (or lack thereof). However, for a radiation detector, the radioactive material is the source itself. The only exception to this is the field of active interrogations where radiation is beamed into a material to entice new/additional radiation emission beyond what the material would emit spontaneously. The aspect of the nuclear material being the source itself means that all other objects in the environment are 'illuminated' or irradiated by the source. Most radiation will readily penetrate regular material, scatter in new directions or be absorbed. Thus if a radiation source is located near a larger object that object will in turn scatter some radiation that was initially emitted in a direction other than the direction of the radiation detector, this can add to the count rate that is observed. The effect of these scatter is a deviation from the traditional distance dependence of the radiation signal and is a key challenge that needs a combined system calibration solution and algorithms. Thus both an algebraic approach as well as a statistical approach have been developed and independently evaluated to investigate the sensitivity to this deviation from the simplified radiation fall-off as a function of distance. The resulting calibrated system algorithms are used and demonstrated in various laboratory scenarios, and later in realistic tracking scenarios. The selection and testing of radiological and computer-vision sensors for the additional specific scenarios will be the subject of ongoing and future work. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗