Search NASA⌕ Search

SEARCH · Search NASA

Results for “rapid adjustments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

An Experimental Evaluation of Generalized Predictive Control for Tiltrotor Aeroelastic Stability Augmentation in Airplane Mode of Flight

The results of a joint NASA/Army/Bell Helicopter Textron wind-tunnel test to assess the potential of Generalized Predictive Control (GPC) for actively controlling the swashplate of tiltrotor aircraft to enhance aeroelastic stability in the airplane mode of flight are presented. GPC is an adaptive time-domain predictive control method that uses a linear difference equation to describe the input-output relationship of the system and to design the controller. The test was conducted in the Langley Transonic Dynamics Tunnel using an unpowered 1/5-scale semispan aeroelastic model of the V-22 that was modified to incorporate a GPC-based multi-input multi-output control algorithm to individually control each of the three swashplate actuators. Wing responses were used for feedback. The GPC-based control system was highly effective in increasing the stability of the critical wing mode for all of the conditions tested, without measurable degradation of the damping in the other modes. The algorithm was also robust with respect to its performance in adjusting to rapid changes in both the rotor speed and the tunnel airspeed.

Kvaternik, Raymond G.↗

Sympathetic responses to Valsalva's manoeuvre following bed rest

The purpose of this study was to examine whether 14 days of head-down tilt bed rest (HDBR) alters autonomic regulation during Valsalva's manoeuvre (VM) and if this would predict blood pressure control during a 60 degrees head-up tilt (HUT) test. To examine autonomic control of blood pressure, we measured the changes in systolic (delta SBP) and diastolic (delta DBP) blood pressure between baseline and the early straining (Phase IIE) period of VM (20 sec straining to 40 mmHg; N = 7) in conjunction with changes in muscle sympathetic nerve activity (MSNA; microneurography) burst frequency (B/min) and total activity (% delta) from baseline over the 20-sec straining period. MSNA data were successfully recorded from 6 of the 7 individuals. The averaged responses from three repeated VMs performed in the supine position were compared between the pre- and post-HDBR tests. Compared with the pre-HDBR test, a greater reduction in SBP, DBP, and MAP was observed during Phase IIE following HDBR, p < 0.05. The increase in MSNA burst frequency during straining was augmented in the post- compared with the pre-HDBR test, p < 0.0001, as was the Phase IV blood pressure overshoot, p < 0.05. Although all subjects completed the 20-min pre-HDBR tilt test without evidence of hypotension or orthostatic intolerance, the post-HDBR test was stopped early in 5 of the 7 subjects due to systolic hypotension. The responses during the VM suggest that acute autonomic adjustments to rapid blood pressure changes are preserved after bed rest. Furthermore, MSNA and blood pressure responses during VM did not predict blood pressure control during orthostasis following HDBR.

NASA Discipline Musculoskeletal↗

Automatic Alignment of Displacement-Measuring Interferometer

A control system strives to maintain the correct alignment of a laser beam in an interferometer dedicated to measuring the displacement or distance between two fiducial corner-cube reflectors. The correct alignment of the laser beam is parallel to the line between the corner points of the corner-cube reflectors: Any deviation from parallelism changes the length of the optical path between the reflectors, thereby introducing a displacement or distance measurement error. On the basis of the geometrical optics of corner-cube reflectors, the length of the optical path can be shown to be L = L(sub 0)cos theta, where L(sub 0) is the distance between the corner points and theta is the misalignment angle. Therefore, the measurement error is given by DeltaL = L(sub 0)(cos theta - 1). In the usual case in which the misalignment is small, this error can be approximated as DeltaL approximately equal to -L(sub 0)theta sup 2/2. The control system (see figure) is implemented partly in hardware and partly in software. The control system includes three piezoelectric actuators for rapid, fine adjustment of the direction of the laser beam. The voltages applied to the piezoelectric actuators include components designed to scan the beam in a circular pattern so that the beam traces out a narrow cone (60 microradians wide in the initial application) about the direction in which it is nominally aimed. This scan is performed at a frequency (2.5 Hz in the initial application) well below the resonance frequency of any vibration of the interferometer. The laser beam makes a round trip to both corner-cube reflectors and then interferes with the launched beam. The interference is detected on a photodiode. The length of the optical path is measured by a heterodyne technique: A 100- kHz frequency shift between the launched beam and a reference beam imposes, on the detected signal, an interferometric phase shift proportional to the length of the optical path. A phase meter comprising analog filters and specialized digital circuitry converts the phase shift to an indication of displacement, generating a digital signal proportional to the path length.

Halverson, Peter↗

Rayleigh Scattering Measurements Using a Tunable Liquid Crystal Fabry-Perot Interferometer

Spectroscopic Rayleigh scattering is an established flow diagnostic that has the ability to provide simultaneous density, velocity, and temperature measurements. The Fabry-Perot interferometer or etalon is a commonly employed instrument for resolving the spectrum of molecular Rayleigh scattered light for the purpose of evaluating these flow properties. This paper investigates the use of a tunable liquid crystal (LC) Fabry-Perot etalon in Rayleigh scattering experiments at NASA Glenn Research Center. The LC etalon provides a robust interferometry system that can be tuned rapidly by adjusting the voltage applied to the liquid crystal interface. Tuning the interferometer is often necessary to control the physical locations of the concentric interference fringes when Rayleigh light is imaged through the LC etalon. The LC etalon diagnostic system was tested in a 1-cm diameter nozzle flow in two different scattering configurations to evaluate its usefulness for Rayleigh measurements compared to a traditional non-tunable fused silica Fabry-Perot etalon.

Mielke-Fagan, Amy F.↗

Black Carbon and Precipitation: an Energetics Perspective

Black carbon aerosols (BC) influence precipitation through a range of processes. The climate response to the presence of BC is however highly dependent on its vertical distribution. Here, we analyze the changes in the energy budget and precipitation impacts of adding a layer of BC at a range of altitudes in two independent global climate models. The models are run with atmosphere‐only and slab ocean model setup to analyze both fast and slow responses, respectively. Globally, precipitation changes are tightly coupled to the energy budget. We decompose the precipitation change into contributions from absorption of solar radiation, atmospheric longwave radiative cooling, and sensible heat flux at the surface. We find that for atmosphere‐only simulations, BC rapidly suppress precipitation, independent of altitude, mainly because of strong atmospheric absorption. This reduction is offset by increased atmospheric radiative longwave cooling and reduced sensible heat flux at the surface, but not of sufficient magnitude to prevent reduced precipitation. On longer timescales, when the surface temperature is allowed to respond, we find that the precipitation increase associated with surface warming can compensate for the initial reduction, particularly for BC in the lower atmosphere. Even though the underlying processes are strikingly similar in the two models, the resulting change in precipitation and temperature by BC differ quite substantially.

black carbon aerosols↗

NO2 Anomalies - Economy Attribution and Rapid Climate Response

Using principal component (PC) analysis of 16 years of monthly series of NO2 from OMI/Aura, we show that it is the third PC (PC3) from the full hierarchy of principal modes that is best coupled with the economic indicators. This coupling is positive, i.e. PC3 and economic indicators manifest positive covariance. However, the economic variability can explain only 40%of the information in PC3. Furthermore, this mode by itself explains only 3% of the total deseasonalized NO2 variability. We thus conclude that, while having an unambiguous impact, the economy can be awarded at best third order of importance in driving the deseasonalized NO2 series, i.e. after seasonal variability is removed from the series. Once we identified PC3 as the NO2 mode that is coupled with economic variability, we use this mode as an indicator and look for rapid climate adjustments to that part of NO2 variability that we are confident is coupled with the economic variability. We focus on observational data from the Atmospheric Infrared Sounder (AIRS) on board of NASA Aqua satellite, decompose series of surface skin temperature and clear-sky outgoing longwave radiances (OLR) into principal components, and identify potential impacts of NO2 PC3 on these climate variables.

NO2↗

Modelling Greenland Outlet Glaciers

The objective of this project was to develop simple yet realistic models of Greenland outlet glaciers to better understand ongoing changes and to identify possible causes for these changes. Several approaches can be taken to evaluate the interaction between climate forcing and ice dynamics, and the consequent ice-sheet response, which may involve changes in flow style. To evaluate the icesheet response to mass-balance forcing, Van der Veen (Journal of Geophysical Research, in press) makes the assumption that this response can be considered a perturbation on the reference state and may be evaluated separately from how this reference state evolves over time. Mass-balance forcing has an immediate effect on the ice sheet. Initially, the rate of thickness change as compared to the reference state equals the perturbation in snowfall or ablation. If the forcing persists, the ice sheet responds dynamically, adjusting the rate at which ice is evacuated from the interior to the margins, to achieve a new equilibrium. For large ice sheets, this dynamic adjustment may last for thousands of years, with the magnitude of change decreasing steadily over time as a new equilibrium is approached. This response can be described using kinematic wave theory. This theory, modified to pertain to Greenland drainage basins, was used to evaluate possible ice-sheet responses to perturbations in surface mass balance. The reference state is defined based on measurements along the central flowline of Petermann Glacier in north-west Greenland, and perturbations on this state considered. The advantage of this approach is that the particulars of the dynamical flow regime need not be explicitly known but are incorporated through the parameterization of the reference ice flux or longitudinal velocity profile. The results of the kinematic wave model indicate that significant rates of thickness change can occur immediately after the prescribed change in surface mass balance but adjustments in flow rapidly diminish these rates to a few cm/yr at most. The time scale for adjustment is of the order of a thousand years or so.

vanderVeen, Cornelis↗

Stratospheric NO and NO2 Abundances from ATMOS Solar-Occultation Measurements

Using results from a time-dependent photochemical model to calculate the diurnal variation of NO and NO2, we have corrected Atmospheric Trace MOlecule Spectroscopy (ATMOS) solar-occultation retrievals of the NO and NO2 abundances at 90' solar zenith angle. Neglecting to adjust for the rapid variation of these gases across the terminator results in potential errors in retrieved profiles of approximately 20% for NO2 and greater than 100% for NC at altitudes below 25 km. Sensitivity analysis indicates that knowledge of the local 03 and temperature profiles, rather than zonal mean or climatological conditions of these quantities, is required to obtain reliable retrievals of NO and NO2 in the lower stratosphere. Extremely inaccurate 03 or temperature values at 20 km can result in 50% errors in retrieved NO or NO2. Mixing ratios of NO in the mid-latitude, lower stratosphere measured by ATMOS during the November 1994 ATLAS-3 mission compare favorably with in situ ER-2 observations, providing strong corroboration of the reliability of the adjusted space-borne measurements.

Newchurch, M. J.↗

Influence of central set on anticipatory and triggered grip-force adjustments

The effects of predictability of load magnitude on anticipatory and triggered grip-force adjustments were studied as nine normal subjects used a precision grip to lift, hold, and replace an instrumented test object. Experience with a predictable stimulus has been shown to enhance magnitude scaling of triggered postural responses to different amplitudes of perturbations. However, this phenomenon, known as a central-set effect, has not been tested systematically for grip-force responses in the hand. In our study, predictability was manipulated by applying load perturbations of different magnitudes to the test object under conditions in which the upcoming load magnitude was presented repeatedly or under conditions in which the load magnitudes were presented randomly, each with two different pre-load grip conditions (unconstrained and constrained). In constrained conditions, initial grip forces were maintained near the minimum level necessary to prevent pre-loaded object slippage, while in unconstrained conditions, no initial grip force restrictions were imposed. The effect of predictable (blocked) and unpredictable (random) load presentations on scaling of anticipatory and triggered grip responses was tested by comparing the slopes of linear regressions between the imposed load and grip response magnitude. Anticipatory and triggered grip force responses were scaled to load magnitude in all conditions. However, regardless of pre-load grip force constraint, the gains (slopes) of grip responses relative to load magnitudes were greater when the magnitude of the upcoming load was predictable than when the load increase was unpredictable. In addition, a central-set effect was evidenced by the fewer number of drop trials in the predictable relative to unpredictable load conditions. Pre-load grip forces showed the greatest set effects. However, grip responses showed larger set effects, based on prediction, when pre-load grip force was constrained to lower levels. These results suggest that anticipatory processes pertaining to load magnitude permit the response gain of both voluntary and triggered rapid grip force adjustments to be set, at least partially, prior to perturbation onset. Comparison of anticipatory set effects for reactive torque and lower extremity EMG postural responses triggered by surface translation perturbations suggests a more general rule governing anticipatory processes.

Non-NASA Center↗

Global Biogeochemistry: an Overview

The dynamic biogeochemical equilibria among the major pools of carbon, nitrogen, sulfur, and phosphorus represented by terrestrial biomes, the world's oceans, and the troposphere are disturbed. Since even the most rapid processes of adjustments among the reservoirs take decades, new equilibria are far from established. These human-induced perturbations and the system's subsequent responses constitute an on-going biogeochemical experiment at the global level. Current and new information must be combined in a way that allows testing of various hypotheses about the workings of global biogeochemical systems. This enables assessment of current knowledge and evaluation of the gaps.

Moore, B., III↗

Stride-Cycle Influences on Goal-Directed Head Movements Made During Walking

Horizontal head movements were studied in six subjects as they made rapid horizontal gaze adjustments while walking. The aim of the present research was to determine if gait-cycle events alter the head movement response to a visual target acquisition task. Gaze shifts of approximately 40deg were elicited by a step change in the position of a visual target from a central location to a second location in the left or right horizontal periphery. The timing of the target position change was constrained to occur at 25,50,75 and 100% of the stride cycle. The trials were randomly presented as the subjects walked on a treadmill at their preferred speed (range: 1.25 to 1.48 m/s, mean: 1.39 +/- 0.09 m/s ) . Analyses focused on the movement onset latencies of the head and eyes and on the peak velocity and saccade amplitude of the head movement response. A comparison of the group means indicated that the head movement onset lagged the eye onset (262 ms versus 252 ms). The head and eye movement onset latencies were not affected by either the direction of the target change nor the point in the gait cycle during which the target relocation occurred. However, the presence of an interaction between the gait cycle events and the direction of the visual target shift indicates that the peak head saccade velocity and head saccade amplitude are affected by the natural head oscillations that occur while walking.

Peters, Brian T.↗

Stratospheric NO and NO(sub 2) Abundances from ATMOS Solar-Occultation Measurements

Using results from a time-dependent photochemical model to calculate the diurnal variation of NO and NO(sub 2), we have corrected Atmospheric Trace Molecule Spectroscopy (ATMOS) solar-occultation retrievals of the NO and NO(sub 2) abundances at 90 solar zenith angle. Neglecting to adjust for the rapid variation of these gases across the terminator results in potential errors in retrieved profiles of approx. 20 percent for NO(sub 2) and greater than 100 percent for NO at altitudes below 25 KM.

NO NO2 ATMOS↗

Forced unsteady deceleration of a turbulent boundary layer from a temporal perspective

The behavior of a turbulent boundary layer which has been subjected to a local ramp-like deceleration in the external velocity field, which leads to forced separation, has been studied experimentally. The data of this study are re-interpreted in light of more recent findings concerning the temporal nature of boundary layer turbulence in the presence of forced unsteady shear. In particular, the robustness of the near-wall turbulent motions to organized deformation is recognized. Their resilence during unsteady shearing action promotes continued efficient turbulent mixing and rapid redistribution of turbulent kinetic energy during forced transients. In aerodynamic problems, the rapid nature of the adjustment of the turbulence field to a new temporal boundary condition necessitates equally rapid remedial measures to be taken if means of control/prevention of forced unsteady separation are to be deployed to maximum effect. This requirement suggests exploration of the use of simple, real-time statistical forecasting techniques, based upon time-series analysis of easily-measurable features of the flow, to help assure timely deployment of mechanisms of boundary-layer control. This paper focuses upon the nature of turbulence in boundary layers undergoing forced deceleration which would lead to separation. A preliminary form of a forecasting model is presented and evaluated. Using observations of the previous two large eddies passing a detector, it forecasts the behavior of the future large eddy rather well.

Brereton, G. J.↗

Design for a Rapid Automatic Sync Acquisition System

System provides rapid command sync acquisition between widely separated transmitter-receivers. It is based on a rapid, automatic range-adjustment approach rather than the time-consuming cycle slipping or stepping techniques of conventional phase-locked loops.

Anderson, T. O.↗

Medical vest broadens treatment capability

Universal sized vest, with specially tailored pockets designed to hold medical supplies, provides first aid/first care medical teams with broadened on-site capability. Vest is made of nylon, tough fibrous materials, and polyvinyl chloride. Design facilitates rapid donning, doffing, and adjustment.

Johnson, G. S.↗

Development and validation of an advanced low-order panel method

A low-order potential-flow panel code, PMARC, for modeling complex three-dimensional geometries, is currently being developed at NASA Ames Research Center. The PMARC code was derived from a code named VSAERO that was developed for Ames Research Center by Analytical Methods, Inc. In addition to modeling potential flow over three-dimensional geometries, the present version of PMARC includes several advanced features such as an internal flow model, a simple jet wake model, and a time-stepping wake model. Data management within the code was optimized by the use of adjustable size arrays for rapidly changing the size capability of the code, reorganization of the output file and adopting a new plot file format. Preliminary versions of a geometry preprocessor and a geometry/aerodynamic data postprocessor are also available for use with PMARC. Several test cases are discussed to highlight the capabilities of the internal flow model, the jet wake model, and the time-stepping wake model.

Ashby, Dale L.↗

Design Concept for a Rapid Automatic Sync Acquisition System

A design has been conceived for a system intended to provide rapid command sync acquisition between widely separated transmitter-receivers, such as between a spacecraft telemetry transmitter, and a ground-based receiver. Use of the system in commercial satellite communications would facilitate rapid sync acquisition between stations and regaining of data lock after interruption or equipment failure. The system is based on a rapid, automatic range-adjustment approach rather than the time-consuming cycle slipping or stepping techniques of conventional phase-locked loops.

Anderson, T. O.↗

Expansion Valve With Temperature-Sensitive Flow Regulation

Joule-Thomson expansion valve designed so particles or condensed contaminants in vapor flowing through unlikely to clog orifice. In addition, new valve automatically adjusts flow of vapor. Allows high initial flow for rapid cooling, but gradually reduces flow as operating temperature reached. Flow adjusts manually when necessary. Developed for expansion of high-pressure vapors to condense them into low-pressure cryogenic liquids. Used to conserve helium coolant in superconducting system by condensing vapor boiling from liquid-helium bath.

Walker, Graham↗