Search NASA⌕ Search

SEARCH · Search NASA

Results for “reduce human contact”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Modifying a Commercial Centrifuge to Reduce Electromagnetic Interference and Evaluating Functionality of Ultrasound Equipment

The Project Management and Engineering Branch (SF4) supports the Human Health and Performance Directorate (HH&P) and is responsible for developing and supporting human systems hardware for the International Space Station (ISS). When a principal investigator's (PI) medical research project on the ISS is accepted, SF4 develops the necessary hardware and software to transport to the ISS. The two projects I primarily worked on were the centrifuge and ultrasound projects. Centrifuge: One concern with spacecraft such as the ISS is electromagnetic interference (EMI) from onboard equipment, typically from radio waves (frequencies of ~3 kHz to ~300 GHz), which can negatively affect nearby circuitry. Standard commercial centrifuges produce EMI above safety limits, so my task was to help reduce EMI production from this equipment. Two centrifuges were tested: one unmodified as a control and one modified. To reduce EMI below safety limits, one centrifuge was modified to become a Faraday shield, in which significant electrical contact was made between all regions of the centrifuge housing. This included removing non-conductive paint, applying conductive fabric to the lid and foam sealer, adding a 10,000 μF decoupling capacitor across the power supply, and adding copper adhesive-mount gaskets to the housing interior. EMI testing of both centrifuges was performed in the EMI/EMC Control Test and Measurement Facility. EMI for both centrifuges was below safety limits for frequencies between 10 MHz and 15 GHz (pass); however, between 14 kHz and 10 MHz, EMI for the unmodified centrifuge exceeded safety limits (fail) as expected. Alternatively, for the modified centrifuge with the Faraday shield, EMI was below the safely limit of 55 dBμV/m for electromagnetic frequencies between 14 kHz and 10 MHz. This result indicates our modifications were successful. The successful EMI test allowed us to communicate with the vendor what modifications they needed to make to their commercial unit to meet our specifications and to understand what needs to be done in lab to the new centrifuge. Our modifications will provide a standard for readying centrifuges for future missions. Once the new modified centrifuge arrives by the vendor, it will need to undergo EMI testing again for validation. The centrifuge is also in the process of compatibility testing with a custom stowage drawer, which is an ongoing project in SF4. Both of these items will be payloads on future missions to the ISS for various research purposes. Ultrasound: ISS currently has an onboard ultrasound (Ultrasound 2 system) for research and medical purposes. Every piece of medical flight hardware has an equivalent ground-unit so instrumentation can be routinely evaluated and transported to the ISS if necessary. The ground-unit ultrasound equipment must be evaluated every six months using a task performance sheet (TPS). A TPS is a document, written by the appropriate scientists and engineers, which describes how to run equipment and is written in such a way that astronauts with unspecialized training can follow the tasks. I was responsible for performing six TPSs on a combination of three ultrasounds and two video power converters (VPCs). Performing a TPS involves checking out and computationally documenting each piece of equipment removed from storage locations, setting up hardware and software, performing tasks to verify functionality, returning equipment, and logging items back into the computerized system. My work revealed all ground-unit ultrasounds were functioning properly. Because of proper function, a discrepancy report (DR) did not have to be opened. The TPS was then passed along to the Quality Engineering (QE) for review and ultimately given to Quality Assurance (QA). Other projects: In addition to my main projects, I participated in other tasks including troubleshooting an EEG headband, volunteering for an ultrasound training research study, and conformal coating printed circuit boards. My internship at SF4 has helped me understand how space systems hardware development for the ISS fits into NASA's mission and vision.

Greening, Gage J.↗

Haptic cues for orientation and postural control in sighted and blind individuals

Haptic cues from fingertip contact with a stable surface attenuate body sway in subjects even when the contact forces are too small to provide physical support of the body. We investigated how haptic cues derived from contact of a cane with a stationary surface at low force levels aids postural control in sighted and congenitally blind individuals. Five sighted (eyes closed) and five congenitally blind subjects maintained a tandem Romberg stance in five conditions: (1) no cane; (2,3) touch contact (< 2 N of applied force) while holding the cane in a vertical or slanted orientation; and (4,5) force contact (as much force as desired) in the vertical and slanted orientations. Touch contact of a cane at force levels below those necessary to provide significant physical stabilization was as effective as force contact in reducing postural sway in all subjects, compared to the no-cane condition. A slanted cane was far more effective in reducing postural sway than was a perpendicular cane. Cane use also decreased head displacement of sighted subjects far more than that of blind subjects. These results suggest that head movement control is linked to postural control through gaze stabilization reflexes in sighted subjects; such reflexes are absent in congenitally blind individuals and may account for their higher levels of head displacement.

NASA Discipline Neuroscience↗

Design of robot grippers for binder jet products handling

Dimension accuracy, damage minimization, and defect detection are essential in manufacturing processes, especially additive manufacturing. These types of challenges may arise either during the manufacture of a product or its use. The repeatability of the process is vital in additive manufacturing systems. However, human users may lose concentration and, thus, would be a great alternative as an assistant. Depending on the nature of work, a robot’s fingers might vary, for example, mechanical, electrical, vacuum, two-fingers, and three-fingers. In addition, the end effector plays a vital role in picking up an object in the advanced manufacturing process. However, inbuilt robotic fingers may not be appropriate in different production environments. In this research presented here considering metal binder jet additive manufacturing, the two-finger end- effectors are proposed design, analysis, and experiment to pick up an object after completing the production process from a specific location. The final designs were further printed by using a 3D metal printer and installed in the existing robotic systems. These new designs are used successfully to hold the object from the specific location by reducing the contact force that was not possible with the previously installed end effector's finger. In addition, a numerical study was conducted in order to compare the flowability of the geometric shape of finger's free areas.

42 ENGINEERING↗

Haptic stabilization of posture: changes in arm proprioception and cutaneous feedback for different arm orientations

Postural sway during quiet stance is attenuated by actively maintained contact of the index finger with a stationary surface, even if the level of applied force (<1 N) cannot provide mechanical stabilization. In this situation, changes in force level at the fingertip lead changes in center of foot pressure by approximately 250 ms. These and related findings indicate that stimulation of the fingertip combined with proprioceptive information about the hand and arm can serve as an active sensor of body position relative to the point of contact. A geometric analysis of the relationship between hand and torso displacement during body sway led to the prediction that arm and hand proprioceptive and finger somatosensory information about body sway would be maximized with finger contact in the plane of body sway. Therefore, the most postural stabilization should be possible with such contact. To test this analysis, subjects touched a laterally versus anteriorly placed surface while in each of two stances: the heel-to-toe tandem Romberg stance that reduces medial-lateral stability and the heel-to-heel, toes-outward, knees-bent, "duck stance" that reduces fore-aft stability. Postural sway was always least with finger contact in the unstable plane: for the tandem stance, lateral fingertip contact was significantly more effective than frontal contact, and, for the duck stance, frontal contact was more effective than lateral fingertip contact. Force changes at the fingertip led changes in center of pressure of the feet by approximately 250 ms for both fingertip contact locations for both test stances. These results support the geometric analysis, which showed that 1) arm joint angles change by the largest amount when fingertip contact is maintained in the plane of greatest sway, and 2) the somatosensory cues at the fingertip provide both direction and amplitude information about sway when the finger is contacting a surface in the unstable plane.

Non-NASA Center↗

New Approach Methodology for Assessing Inhalation Risks of a Contact Respiratory Cytotoxicant: Computational Fluid Dynamics-Based Aerosol Dosimetry Modeling for Cross-Species and In Vitro Comparisons

Regulatory agencies are considering alternative approaches to assessing inhalation toxicity that utilizes in vitro studies with human cells and in silico modeling in lieu of additional animal studies. In support of this goal, computational fluid-particle dynamics models were developed to estimate site-specific deposition of inhaled aerosols containing the fungicide, chlorothalonil, in the rat and human for comparisons to prior rat inhalation studies and new human in vitro studies. Under bioassay conditions, the deposition was predicted to be greatest at the front of the rat nose followed by the anterior transitional epithelium and larynx corresponding to regions most sensitive to local contact irritation and cytotoxicity. For humans, simulations of aerosol deposition covering potential occupational or residential exposures (1–50 µm diameter) were conducted using nasal and oral breathing. Aerosols in the 1–5 µm range readily penetrated the deep region of the human lung following both oral and nasal breathing. Under actual use conditions (aerosol formulations >10 µm), the majority of deposited doses were in the upper conducting airways. Beyond the nose or mouth, the greatest deposition in the pharynx, larynx, trachea, and bronchi was predicted for aerosols in the 10–20 µm size range. Only small amounts of aerosols >20 µm penetrated past the pharyngeal region. Using the ICRP clearance model, local retained tissue dose metrics including maximal concentrations and areas under the curve were calculated for each airway region following repeated occupational exposures. These results are directly comparable with benchmark doses from in vitro toxicity studies in human cells leading to estimated human equivalent concentrations that reduce the reliance on animals for risk assessments.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Activation and proliferation of lymphocytes and other mammalian cells in microgravity

The experimental findings reviewed in this chapter support the following conclusions: Proliferation. Human T-lymphocytes, associated with monocytes as accessory cells, show dramatic changes in the centrifuge, in the clinostat and in space. In free-floating cells the mitogenic response is depressed by 90% in microgravity, whereas in cells attached to a substratum activation is enhanced by 100% compared to 1-G ground and inflight controls. The duration of phase G1 of the mitotic cycle of HeLa cells is reduced in hypergravity, resulting in an increased proliferation rate. Other systems like Friend cells and WI38 human embryonic lung cells do not show significant changes. Genetic expression and signal transduction. T-lymphocytes and monocytes show important changes in the expression of cytokines like interleukin-1, interleukin-2, interferon-gamma and tumor necrosis factor. The data from space experiments in Spacelab, Space Shuttle mid-deck, and Biokosmos have helped to clarify certain aspects of the mechanism of T-cell activation. Epidermoid A431 cells show changes in the genetic expression of the proto-oncogenes c-fos and c-jun in the clinostat and in sounding rockets. Membrane function, in particular the binding of ligates as first messengers of a signal, is not changed in most of the cell systems in microgravity. Morphology and Mortility. Free cells, lymphocytes in particular, are able to move and form aggregates in microgravity, indicating that cell-cell contacts and cell communications do take place in microgravity. Dramatic morphological and ultrastructural changes are not detected in cells cultured in microgravity. Important experiments with single mammalian cells, including immune cells, were carried out recently in three Spacelab flights, (SL-J, D-2, and IML-2 in 1992, 1993, and 1994, respectively). The results of the D-2 mission have been published in ref. 75; those of the IML-2 mission in ref. 76. Finally, many cell biology experiments in space have suffered in the past from a lack of adequate controls (like 1-G centrifuges) and of proper experimental conditions (like well-controlled temperature). In this respect the availability of Biorack, outfitted with proper incubators with 1-G control centrifuge as well as a glovebox with a microscope, is a great advantage. It is also desirable that cell biology experiments in space are accompanied or even preceded by a program of ground-based investigations in the fast rotating clinostat and in the centrifuge, and that preparatory experiments be done in parabolic flights and sounding rockets, whenever possible. Proper publication of the results of space experiments is another important need. A great number of data have been published in proceedings and reports that are not available to the broad scientific community. To guarantee the credibility and the international recognition of space biology it is important that the results be published in international, peer reviewed journals.

manned↗

Investigating Laser Beam Welding as an In-Space Joining Technique via Thermal Vacuum and Microgravity and Vacuum Experiments

In-space joining technologies are crucial for stimulating an in-space economy and for enabling sustained space exploration by in-space manufacturing and repair of metallic structures. Compared to brazing or soldering, in-space welding (ISW) can provide highly hermetic, strong, and complex joints, potentially without introducing additional material. However, the influence of extreme temperatures, reduced pressure, and reduced gravity on ISW is not yet fully elucidated. Several efforts at NASA are investigating laser beam welding (LBW) as a joining and repair method in both thermal vacuum (TVAC) and combined vacuum & reduced gravity environments. NASA Marshall Space Flight Center (MSFC) shepherded several ISW projects in its past, including the 1973 electron beam welding on Skylab, the 1989 low-power LBW on parabolic flights, and the unflown 1990s-era In-Space Welding Experiment. Recent parabolic flights and 3 degree-of-freedom ground testing build upon this heritage. A collaboration with the Ohio State University using NASA Langley Research Center (LaRC) hardware retrofitted for LBW achieved the first high-powered laser welds under vacuum and low gravity and developed a workforce capable developing such experimental hardware. A ground testing campaign at the MSFC Flat Floor simulated fit-up and welding representative of ISW in 3 degrees of freedom to emulate microgravity effects on inertial systems. One ongoing effort is a NASA Early Career Initiative project – Lunar Assembly and Servicing by Autonomous Robotics (LASAR). Ruggedized LBW components were developed by an external partner for use in TVAC. A TVAC-rated robotic arm was procured by MSFC and used in the first known robotic laser weld where all components save the laser generator were under vacuum. NASA Johnson Space Center (JSC) is advancing supervised autonomy of ISW. NASA LaRC continues to adapt their unique snowflake joint geometry, suitable for connecting segments in trusses and other structures, to LBW. Upcoming TVAC campaigns will focus on testing extreme temperatures, proving out autonomous operations, and demonstrating weld repair. Weld inspection will occur via a non-contact nondestructive evaluation (NDE) technique – electromagnetic acoustic transduction (EMAT). Another ongoing effort based at MSFC is the DISCMAN -- DIsk-Shaped Configurable and Modular vAcuum uNit – which seeks to development a compact, modular payload that can provide a vacuum environment while in a reduced gravity condition. This payload could support multiple in-space manufacturing developmental efforts, with the first demonstration technology being LBW. Currently, the design is targeting operations in the pressurized volume of a space station, but the payload could readily be adapted to other flight platforms such as parabolic or even suborbital vehicles. LASAR elucidates the effects of temperature and vacuum on LBW while DISCMAN probes those of vacuum and gravity. Through these complementary efforts, NASA is addressing the primary challenges of ISW across the space environment while simultaneously developing and maturing technologies including robotic systems and inspection methodologies for future practical implementation on the Moon and beyond. This approach is timely, as upcoming missions requiring sustained human presence in space will depend on reliable ISW capabilities to create robust metallic joints currently unproven in the space environment and to perform repairs in situ .

hypogravity↗

Adaptive changes in sexual behavior in the high–risk population in response to human monkeypox transmission in Canada can help control the outbreak: Insights from a two–group, two–route epidemic model

Monkeypox, a zoonotic disease, is emerging as a potential sexually transmitted infection/disease, with underlying transmission mechanisms still unclear. We devised a risk-structured, compartmental model, incorporating sexual behavior dynamics. We compared different strategies targeting the high-risk population: a scenario of control policies geared toward the use of condoms and/or sexual abstinence (robust control strategy) with risk compensation behavior change, and a scenario of control strategies with behavior change in response to the doubling rate (adaptive control strategy). Monkeypox's basic reproduction number is 1.464, 0.0066, and 1.461 in the high-risk, low-risk, and total populations, respectively, with the high-risk group being the major driver of monkeypox spread. Policies imposing condom use or sexual abstinence need to achieve a 35% minimum compliance rate to stop further transmission, while a combination of both can curb the spread with 10% compliance to abstinence and 25% to condom use. With risk compensation, the only option is to impose sexual abstinence by at least 35%. Adaptive control is more effective than robust control where the daily sexual contact number is reduced proportionally and remains constant thereafter, shortening the time to epidemic peak, lowering its size, facilitating disease attenuation, and playing a key role in controlling the current outbreak.

60 APPLIED LIFE SCIENCES↗

Development and Evaluation of Titanium Spacesuit Bearings

The Z-2 Prototype Planetary Extravehicular Space Suit Assembly is a continuation of NASA's Z-series of spacesuits, designed with the intent of meeting a wide variety of exploration mission objectives, including human exploration of the Martian surface. Incorporating titanium bearings into the Z-series space suit architecture allows us to reduce mass by an estimated 23 lbs per suit system compared to the previously used stainless steel bearing race designs, without compromising suit functionality. There are two obstacles to overcome when using titanium for a bearing race- 1) titanium is flammable when exposed to the oxygen wetted environment inside the space suit and 2) titanium's poor wear properties are often challenging to overcome in tribology applications. In order to evaluate the ignitability of a titanium space suit bearing, a series of tests were conducted at White Sands Test Facility (WSTF) that introduced the bearings to an extreme test profile, with multiple failures imbedded into the test bearings. The testing showed no signs of ignition in the most extreme test cases; however, substantial wear of the bearing races was observed. In order to design a bearing that can last an entire exploration mission (approx. 3 years), design parameters for maximum contact stress need to be identified. To identify these design parameters, bearing test rigs were developed that allow for the quick evaluation of various bearing ball loads, ball diameters, lubricants, and surface treatments. This test data will allow designers to minimize the titanium bearing mass for a specific material and lubricant combination and design around a cycle life requirement for an exploration mission. This paper reviews the current research and testing that has been performed on titanium bearing races to evaluate the use of such materials in an enriched oxygen environment and to optimize the bearing assembly mass and tribological properties to accommodate for the high bearing cycle life for an exploration mission.

Rhodes, Richard↗

Applications of Nickelate perovskites for neuromorphic computing from electronic structure and Machine Learning

While the limit of Moore's law is presently being reached with current microelectronic technologies, we need to develop new paradigms that overcome this limitation. In that respect, neuromorphic computing is a concept that emulates the neural behavior and response of the human brain, and it has been recognized as a promising alternative approach. In this research project, we will perform multi-fidelity scale bridging to explore the potential use of materials with metal to insulator transition for neuromorphic applications. In particular, rare earth nickelates are promising for such purposes, as the transition in these materials is quite sensitive to a broad set of different external stimuli. Our multi-fidelity approach will bridge the high-fidelity electronic structure calculations with classical potentials. We will bridge dynamical mean field theory with a classical atomistic representation via a deep learning force field. The neural network is trained with energies, charges, and forces obtained by accurate electronic structure theories based on Dynamical Mean Field Theory. The configurational space is generated from known crystal phases, ab initio molecular dynamics with exchange-correlation functionals corrected with the Hubbard model, disordered phases with different concentrations of oxygen vacancies, and nonsymmetrical positions and induced strain by grain interfaces or contact with a substrate. Strategies to train the model with a reduced number of training examples are obtained from active learning methods, and new structures for improving the learning process are generated by using machine learning autoencoders. This classical potential will be validated through a diversity of electronic structure methods and represents an important step to combine the flexibility and accuracy of first-principles with the speed of classical potentials. The generated multi-fidelity surrogate model will be used to understand the role of strain, oxygen vacancies, proton doping, the variation of the crystal phase, substrate effects, vibrational effects as the octahedral rotation, grain boundaries and defect effects on the response of a Metal to Insulator Transition (MIT) in correlated materials. Long time and large-scale simulations will help understand the role of different stimuli to control the hysteresis of the MIT, as it has been experimentally suggested. Selected configurations will be analyzed with higher-level theories to provide an accurate electronic description and to study how the orbitals and charges are rearranged under different conditions.

36 MATERIALS SCIENCE↗

Long-term (6-wk) hindlimb suspension inhibits spermatogenesis in adult male rats

The International Space Station will allow extended habitation in space and long-term exposure to microgravity (microG). A concern is the impact of long-term microG exposure on the ability of species to reproduce. The model often used to simulate microG is rat hindlimb suspension (HLS), where the hindlimbs are elevated above the cage floor with a tail harness. Experiments described here are the first to examine the effect of long-term HLS on testicular function in adult male rats. Free-roaming (controls), animals with only the tail harnessed but hindlimbs in contact with the cage floor (TO), and HLS animals were tested for 6 wk. Cryptorchidism was prevented in TO and HLS animals by partial constriction of the inguinal canal with sutures. All parameters were compared at the end of the 6-wk experiment. Testicular weights and spermatogenesis were significantly reduced by HLS, such that no spermatogenic cells beyond round spermatids were present and epididymides were devoid of mature sperm. In many tubules, loss of all germ cells, except a few spermatogonia, resulting in histopathology similar to the Sertoli cell, was observed. Spermatogenesis appeared unaffected in control and TO animals. Sertoli and Leydig cell appearance, testosterone, luteinizing hormone, and follicle-stimulating hormone levels, and epididymal and seminal vesicle weight were unchanged by HLS. Cortisone was not elevated by HLS; thus stress may not be a factor. These results demonstrate that spermatogenesis is severely inhibited by long-term HLS, whereas testicular androgen production is not. These results have significant implications regarding serious effects of long-term exposure to microG on the reproductive capability of scrotal mammals, including humans.

NASA Discipline Cell Biology↗

Spacesuit Fit and Mobility Assessments by Digital Human Modeling

Spacesuit Fit and Mobility Assessments by Digital Human Modeling K. Han Kim (Leidos, Inc.) Elizabeth A. Benson (KBR, Inc.) Sudhakar L. Rajulu (NASA Johnson Space Center) Spacesuits are required to accommodate safe operations for astronauts across gender and a wide variety of body shapes and sizes. This goal has been of particular importance given the increasing diversity of NASA crewmembers for upcoming Missions. While testing with design prototypes is a critical step for spacesuit development, iterative mockup design, fabrication, and human subject tests can be extremely costly and time consuming. Moreover, testing with a limited subject pool has often raised questions for validity, as test subjects need to represent the entire astronaut population, not only of the past or current, but also the future. This study is aimed at demonstrating how digital human modeling (DHM) tools have been built and directly supported NASA spacesuit developments. With DHM, the computer aided design (CAD) model of a spacesuit was integrated with human body models. Two use scenarios are presented in this paper, namely fit and mobility. For fit assessments, the suit-to-body contact and compression patterns were estimated using 3D human body scan models virtually wearing a spacesuit model. A statistical fit classifier was made from the contact patterns and applied against a large database of body scans (N=2,500). With this technique, the NASA reference design spacesuit Exploration EVA Mobility Unit (xEMU)was verified to accommodate 90% of the astronaut-like population, with the critical dimensions covering 1stto 99thpercentiles of the target body measurements. A similar technique assessed XEMU mobility. The maximum reach envelopes were considered, within which the work objects and critical hardware interfaces should be located for safe and ergonomic operations. While the reach envelope geometry varies significantly with the suit wearer’s body size and strength, the existing test data did not include the subjects critically required to define suit mobility requirements, such as very small females or large males. Using the xEMU virtual model kinematically simulated and permuted for a hypothetical wearer, however, the existing data were statistically transformed and scaled. This method enabled for a parametric estimation of the reach envelopes from the 1stpercentile female or 99thpercentile male. The outcome was successfully incorporated for requirement developments. With the new DHM tools, human integration of the spacesuit was structurally simulated and predictively assessed, which would have been otherwise impossible. Also, the needs for iterative mockup and subject tests were significantly reduced, which resulted in time and cost saving. Additional work is in progress to integrate additional vehicles, tools, and hardware with DHM framework.

K Han Kim↗

Revitalization of Space-Related Human Factors, Environmental and Habitability Data

The NASA Chief Health and Medical Officer (CHMO) recently directed that the agency establish crew health standards to aid in the development of requirements for future vehicles and habitats. Response to this direction includes development of a new NASA habitability and human factors standard and an accompanying design handbook. The new standard contains high-level, over-arching principles to assure its applicability and usability across all NASA development programs. The handbook will provide detailed design requirements and suggestions that will meet the standards. The information contained in NASA-STD-3000 will be updated and included in the new design handbook. In this approach, each new program will derive detailed program-specific requirements from the new standard using the handbook as a design guide and resource. With the completion of the standard, the focus of this year s effort is the development of the new handbook: Human Integration Design Handbook (HIDH). This is an opportunity for the space flight human factors and habitability community to consolidate up-to-date data for use by NASA programs and designers as well as outside researchers and policy makers looking for the next research focus. The goal of the handbook is to help NASA design and build human space flight systems which accommodate the capabilities and limitations of the crew so as to provide an environment where the crew can live and work effectively, safely, and comfortably. Handbook contents will address that primary goal, addressing unique aspects of space flight and habitation, including reduced gravity conditions, time lags, EVA systems and day/night cycles, not addressed in other standards or handbooks. The handbook will be divided into topics similar to NASA-STD-3000 (anthropometrics, architecture, workstations, etc.) and each topic area will contain elements for designers, human factors practitioners, program managers, operators, and researchers. The handbook will include the following elements: (1) Design considerations include a clear and concise summary of what is important to designers in space vehicle / habitat design, design information to translate Earth-base knowledge to the space environment, space issues and the data necessary to address those issues, and a consistent set of terminology. (2) Updates to Lessons Learned and example solutions from Shuttle and Station program experience will provide historical examples to help prevent repeating mistakes or reinvention of the wheel. (3) Requirements will aid in the translation of standards into program specific requirements. The scope of included requirements will define the pool that each program needs to consider and tailor for their specific program. (4) Requirements rationale will help understanding of the importance of these considerations. The HIDH development team at JSC is finalizing the format of the new handbook, prioritizing topic areas for expansion and update, and contacting subject matter experts within the scientific community to assist with this effort. Plans are also being made to continue handbook expansion and maintenance to assure it remains a valuable resource for human factors and human space flight programs.

Russo, Dane↗

Contrasting the characteristics of atmospheric pressure plasma jets operated with single and double dielectric material: physicochemical characteristics and application to bacterial killing

Abstract This study reports an experimental comparison of two types of atmospheric pressure plasma jets in terms of their fundamental plasma characteristics and efficacy in bacterial sterilization. The plasma jets are fabricated by inserting a high voltage electrode inside a one-end closed (double DBD plasma jet) or both ends open (single DBD plasma jet) quartz tubes which are further enclosed inside a second quartz tube containing a ground electrode. Both plasma jets are operated in contact with water surface by using a unipolar pulsed DC power supply with helium as the working gas. Results from electrical and time-resolved imaging show that the single DBD configuration induces 3–4 times higher accumulation of charges onto the water surface with significantly faster propagation of plasma bullets. These results are accompanied by the higher discharge intensity as well as stronger emissions from short-lived reactive species which were analyzed through optical emission spectroscopy at the plasma-water interface. The rotational temperature for the single DBD configuration was observed to be higher making it unsafe for direct treatments of sensitive biological targets. These characteristics of the single DBD configuration result in the production of more than two times higher concentration of H 2 O 2 in plasma activated water. Shielding of the HV electrode reduces the plasma potential which in turn reduces the electric field & electron energy at the plasma-water interface. The reduced electric field for the double DBD configuration was lower by ≈463 Td than the single DBD configuration. The bactericidal efficacy of the two configurations of the plasma jets were tested against Escherichia coli , a well studied Gram-negative bacterium that can be commensal and pathogenic in human body. Our results demonstrate that although single DBD plasma jet result in stronger antibacterial effects, the double DBD configuration could be safer.

Physics↗

Development and Evaluation of Titanium Space Suit Bearings

The Z-2 Prototype Planetary Extravehicular Space Suit Assembly is a continuation of NASA's Z series of spacesuits, designed with the intent of meeting a wide variety of exploration mission objectives, including human exploration of the Martian surface. Incorporating titanium bearings into the Z series space suit architecture allows us to reduce mass by an estimated 23 pounds per suit system compared to the previously used stainless steel bearing designs without compromising suit functionality. There are two obstacles to overcome when using titanium for a bearing race: 1) titanium is flammable when exposed to the oxygen wetted environment inside the space suit and 2) titanium's poor wear properties are often challenging to overcome in tribology applications. In order to evaluate the ignitability of a titanium space suit bearing, a series of tests were conducted at White Sands Test Facility that introduced the bearings to an extreme test profile, with multiple failures imbedded into the test bearings. The testing showed no signs of ignition in the most extreme test cases; however, substantial wear of the bearing races was observed. In order to design a bearing that can last an entire exploration mission (approximately 2 years), bearing test rigs were developed that allow for the quick evaluation of various bearing ball loads, ball diameters, lubricants, and surface treatments. This test data will allow designers to minimize the titanium bearing mass for a specific material and lubricant combination around a maximum contact stress that will allow the bearing to survive the life of an exploration mission. This paper reviews the current research and testing that has been performed on titanium bearing races to evaluate the use of such materials in an enriched oxygen environment and to optimize the bearing assembly mass and tribological properties to accommodate for the high bearing cycle life for an exploration mission.

Rhodes, Richard↗

In-Situ Electrochemical Generation and Utilization of Hydrogen Peroxide for Disinfection

Disinfection needs to meet personal hygiene requirements at the International Space Station (ISS) is currently accomplished through the use of pre-packaged, disposable, wetted wipes, which represent an appreciable carry-along mass and disposal burden. However, as human missions travel further into the solar system the availability of resources to resupply will be diminished. Therefore, next-generation system should use onboard utilities to create on demand disinfectants, thereby reducing the dependence on earth-based supplies and further eliminating storage and disposal problems. Accordingly, we are developing an in-situ approach to electrochemically generate hydrogen peroxide disinfecting solution utilizing onboard life support supplies (Air/Water) to neutralize surface microorganisms present in closed living systems. As discussed within our 2019 and 2021 ICES papers (ICES-2019-38 and ICES-2021-273), we have continued to improve our TRL by scaling the electrochemical generation production process and validating the system in a zero-gravity parabolic loop flight test. In this paper we will demonstrate a system that can achieve over 1 L of >2 w/w% peroxide per day with DI water and air feeds. The hydrogen peroxide solutions generated were sent to NASA for microbial control property characterization. Overall, the electrochemical peroxide generation system offers a more economical and practical alternative, with the disinfectant being generated on demand and in-situ (using available life support materials of Air/Water); and applied to reusable cloths. The specific application of interest to this program is crew contact surfaces in space vehicles, but this technology could be utilized for waste water disinfection, heat exchanger biofouling remediation, and laundry applications. The peroxide generation system will also be able to address Earth-based needs in various settings such as field hospitals, restaurants, military, warehouses, movie theatres, among many others.

hydrogen peroxide↗

Air, surface, and wastewater surveillance of SARS-CoV-2; a multimodal evaluation of COVID-19 detection in a built environment

Environmental surveillance of infectious organisms holds tremendous promise to reduce human-to-human transmission in indoor spaces through early detection. In this study we determined the applicability and limitations of wastewater, indoor high-touch surfaces, in-room air, and rooftop exhaust air sampling methods for detecting SARS-CoV-2 in a real world building occupied by residents recently diagnosed with COVID-19. We concurrently examined the results of three 24-hour environmental surveillance techniques, indoor surface sampling, exhaust air sampling and wastewater surveillance, to the known daily census fluctuations in a COVID-19 isolation dormitory. Additionally, we assessed the ability of aerosol samplers placed in the large volume lobby to detect SARS-CoV-2 multiple times per day. Our research reveals an increase in the number of individuals confirmed positive with COVID-19 as well as their estimated human viral load to be associated with statistically significant increases in viral loads detected in rooftop exhaust aerosol samples (p = 0.0413), wastewater samples (p = 0.0323,), and indoor high-touch surfaces (p < 0.001)). We also report that the viral load detected in lobby aerosol samples was statistically higher in samples collected during presence of occupants whose COVID-19 diagnostic tests were confirmed positive via qPCR compared to periods when the lobby was occupied by either contact-traced (suspected positive) individuals or during unoccupied periods (p = 0.0314 and <2e–16). We conclude that each daily (24h) surveillance method, rooftop exhaust air, indoor high-touch surfaces, and wastewater, provide useful detection signals for building owner/operator(s). Furthermore, we demonstrate that exhaust air sampling can provide spatially resolved signals based upon ventilation exhaust zones. Additionally, we find that indoor lobby air sampling can provide temporally resolved signals useful during short duration sampling periods (e.g., 2-4 hours) even with intermittent occupancy by occupants diagnosed with COVID-19.

60 APPLIED LIFE SCIENCES↗

Structural analysis of carbohydrate binding by the macrophage mannose receptor CD206

The human mannose receptor expressed on macrophages and hepatic endothelial cells scavenges released lysosomal enzymes, glycopeptide fragments of collagen, and pathogenic microorganisms and thus reduces damage following tissue injury. The receptor binds mannose, fucose, or N-acetylglucosamine (GlcNAc) residues on these targets. C-type carbohydrate recognition domain 4 (CRD4) of the receptor contains the site for Ca 2+ -dependent interaction with sugars. To investigate the details of CRD4 binding, glycan array screening was used to identify oligosaccharide ligands. The strongest signals were for glycans that contain either Manα1-2Man constituents or fucosein various linkages. The mechanisms of binding to monosaccharides and oligosaccharide substructures present in many of these ligands were examined in multiple crystal structures of CRD4. Binding of mannose residues to CRD4 results primarily from interaction of the equatorial 3- and 4-OH groups with a conserved principal Ca 2+ common to almost all sugar-binding C-type CRDs. In the Manα1-2Man complex, supplementary interactions with the reducing mannose residue explain the enhanced affinity for this disaccharide. Bound GlcNAc also interacts with the principal Ca 2+ through equatorial 3- and 4-OH groups, whereas fucose residues can bind in several orientations, through either the 2- and 3-OH groups or the 3- and 4-OH groups. Secondary contacts with additional sugars in fucose-containing oligosaccharides, such as the Lewis-a trisaccharide, provide enhanced affinity for these glycans. These results explain many of the biologically important interactions of the mannose receptor with both mammalian glycoproteins and microbes such as yeast and suggest additional classes of ligands that have not been previously identified

59 BASIC BIOLOGICAL SCIENCES↗