Search NASA⌕ Search

SEARCH · Search NASA

Results for “reflectance calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Depth-Resolved Lithiated Gradients in Pristine and Laser-Ablated Anodes During Fast Charging

Laser ablating 3D electrode microstructures is a technique to improve Li-ion battery fast-charge performance. This technique has been theoretically proposed and electrochemically validated previously in the literature. The fundamental principle underlying laser ablation is that the ablated features reduce Li-ion transport pathways, improving access to the electrode active material near the current collector. This, in turn, promotes more homogeneous electrode utilization. The present study seeks to directly affirm the physics attributed to laser ablation using operando high-speed synchrotron X-ray diffraction. In this study, depth-resolved graphite lithiation gradients are measured operando during high-rate (15 min) charging. The depth-resolved lithiation dynamics of both ablated and non-ablated anodes are compared. The results highlight that the laser-ablated graphite electrode has notably more homogeneous utilization as compared to the non-ablated electrode. Additionally, the ablated electrode has a significant delay in reaching the maximum graphite lithiation at the separator, indicating less propensity for lithium plating. During low rate delithiation/discharge (2 hr), the two cells' lithiation gradients converge. Notably, a calibrated physics-based electrochemical model accurately reflects experimental findings, suggesting the potential to use pseudo-4D models not only to optimize laser ablation parameters in fast-charge capable electrodes but also to guide fast charging protocols that avoid lithium plating.

25 ENERGY STORAGE↗

ARM FY2026 Radar Plan

The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) User Facility maintains a suite of advanced atmospheric radar systems that serve as critical tools in ARM’s mission to provide continuous, high-quality observations for advancing the understanding and modeling of atmospheric processes. These radar systems enable detailed characterization of clouds, precipitation, and dynamic structures in the atmosphere, supporting a broad range of scientific applications. The number of deployed systems exceeds what current staffing levels can fully support for continuous 24/7/365 operation. As such, it is essential to have a clearly defined and community-informed plan that prioritizes radar operations and communicates ARM’s strategy for sustaining and evolving these observational assets. This FY2026 Radar Plan outlines ARM’s approach to managing its radar portfolio—balancing scientific impact, operational feasibility, and long-term sustainability. It reflects ARM’s continued commitment to delivering calibrated, well-documented radar data products that enable process-level studies and support the development and evaluation of weather and climate models. Through this plan, ARM aims to ensure transparency in decision-making, alignment with user needs, and support for innovative science across the facility’s fixed and mobile observatories. Given uncertainties around the Fiscal Year (FY) 2026 budget, this plan was developed to assume business as usual and will be updated as budgets and plans may change. It should be noted that, given the limited timeframe involved, this plan will be more succinct than previous plans.

47 OTHER INSTRUMENTATION↗

The throughput calibration of the VERITAS telescopes

Context. The response of imaging atmospheric Cherenkov telescopes to incident γ -ray-initiated showers in the atmosphere changes as the telescopes age due to exposure to light and weather. These aging processes affect the reconstructed energies of the events and γ -ray fluxes. Aims. This work discusses the implementation of signal calibration methods for the Very Energetic Radiation Imaging Telescope Array System (VERITAS) to account for changes in the optical throughput and detector performance over time. Methods. The total throughput of a Cherenkov telescope is the product of camera-dependent factors, such as the photomultiplier tube gains and their quantum efficiencies, and the mirror reflectivity and Winston cone response to incoming radiation. This document summarizes different methods to determine how the camera gains and mirror reflectivity have evolved over time and how we can calibrate this changing throughput in reconstruction pipelines for imaging atmospheric Cherenkov telescopes. The implementation is validated against seven years of observations with the VERITAS telescopes of the Crab Nebula, which is a reference object in very-high-energy astronomy. Results. Regular optical throughput monitoring and the corresponding signal calibrations are found to be critical for the reconstruction of extensive air shower images. The proposed implementation is applied as a correction to the signals of the photomultiplier tubes in the telescope simulation to produce fine-tuned instrument response functions. This method is shown to be effective for calibrating the acquired γ -ray data and for recovering the correct energy of the events and photon fluxes. At the same time, it keeps the computational effort of generating Monte Carlo simulations for instrument response functions affordably low.

79 ASTRONOMY AND ASTROPHYSICS↗

Improved liquid lithium surfaces in the Lithium Tokamak Experiment-β

Advances in vacuum, surface, and lithium conditioning techniques throughout five years of continuous operations in LTX-β have produced mirror-like liquid lithium surfaces and demonstrated the feasibility of high-performance tokamak discharges fully surrounded by liquid metal without significant operational problems. Improvements in conditioning techniques and procedures, including many weeks of baking and accumulation of 70 g of Li, led to reduced residual gasses and clean Li surfaces - all while still maintaining enough operational flexibility for multiple in-vacuum diagnostic upgrades and calibrations. Coatings had a visibly clean appearance, with reflective liquid metal demonstrating good wetting and surface adhesion with films that were now macroscopically thick. Solidified Li showed large crystal grains, while surface science measurements observed reduced impurities in the lithium. Steadily improved plasma performance was achieved with liquid lithium, with discharges able to match solid Li in terms of evolution of I p and n e , including rapid density pumping indicating low recycling. There were indications of moderately increased Li impurity influx, though few significant disturbances by the large liquid surfaces on tokamak operations over hundreds of discharges. Liquid metal plasma facing components are a potential solution to the extreme heat and particle fluxes that could cause unacceptable damage to solid materials, while liquid lithium also has the potential for greatly increased confinement in the low-recycling regime. While many liquid metal approaches are possible, and numerous experiments have been conducted in test stands and small modules in fusion devices, LTX-β is the only tokamak operated while fully surrounded by liquid metal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Crystal response measurement of the x-ray transmission crystals used by the Imaging Spectroscopy Snout at the National Ignition Facility

The Imaging Spectroscopy Snout (ISS) used at the National Ignition Facility is able to simultaneously collect neutron pinhole images, 1D spatially resolved x-ray spectra, and time resolved x-ray pinhole images. To measure the x-ray spectra, the ISS can be equipped with up to four different transmission crystals, each offering different energy ranges from ∼7.5 to ∼12 keV and different resolutions. Characterizing and calibrating such instruments is of paramount importance in order to extract meaningful results from experiments. More specifically, we characterized different ISS transmission-type alpha-Quartz crystals by measuring their responses as a function of photon energy, from which we inferred the angle-integrated reflectivity for each crystal’s working reflections. These measurements were made at the Lawrence Livermore National Laboratory calibration station dedicated to the characterization of x-ray spectrometers. The sources used covered a wide x-ray range—from a few to 30 keV; the source diameter was ∼0.6 mm. The experimental results are discussed alongside theoretical calculations using the pyTTE model.

Dozieres, M. (ORCID:0000000286401459)↗

Nonlinear Photovoltaic Degradation Rates: Modeling and Comparison Against Conventional Methods

Although common practice for estimating photovoltaic (PV) degradation rate (RD) assumes a linear behavior, field data have shown that degradation rates are frequently nonlinear. This article presents a new methodology to detect and calculate nonlinear RD based on PV performance time-series from nine different systems over an eight-year period. Prior to performing the analysis and in order to adjust model parameters to reflect actual PV operation, synthetic datasets were utilized for calibration purposes. A change-point analysis is then applied to detect changes in the slopes of PV trends, which are extracted from constructed performance ratio (PR) time-series. Once the number and location of change points is found, the ordinary least squares method is applied to the different segments to compute the corresponding rates. The obtained results verified that the extracted trends from the PR time-series may not always be linear and therefore, “nonconventional” models need to be applied. All thin-film technologies demonstrated nonlinear behavior whereas nonlinearity detected in the crystalline silicon systems is thought to be due to a maintenance event. A comparative analysis between the new methodology and other conventional methods demonstrated levelized cost of energy differences of up to 6.14%, highlighting the importance of considering nonlinear degradation behavior

14 SOLAR ENERGY↗

High-resolution x-ray spectrometer for x-ray absorption fine structure spectroscopy

Two extended x-ray absorption fine structure flat crystal x-ray spectrometers (EFX’s) were designed and built for high-resolution x-ray spectroscopy over a large energy range with flexible, on-shot energy dispersion calibration capabilities. The EFX uses a flat silicon [111] crystal in the reflection geometry as the energy dispersive optic covering the energy range of 6.3–11.4 keV and achieving a spectral resolution of 4.5 eV with a source size of 50 μm at 7.2 keV. A shot-to-shot configurable calibration filter pack and Bayesian inference routine were used to constrain the energy dispersion relation to within ±3 eV. The EFX was primarily designed for x-ray absorption fine structure (XAFS) spectroscopy and provides significant improvement to the Laboratory for Laser Energetics’ OMEGA-60 XAFS experimental platform. The EFX is capable of performing extended XAFS measurements of multiple absorption edges simultaneously on metal alloys and x-ray absorption near-edge spectroscopy to measure the electron structure of compressed 3d transition metals.

47 OTHER INSTRUMENTATION↗

Agentic traffic intelligence: Augmented human-in-the-loop scenario generation for microscopic traffic simulation

Traditional microscopic traffic simulation generation often relies on static datasets and manual design, limiting its ability to simulate complex conditions easily. This paper presents a novel framework, Agentic Traffic Intelligence, which combines human approval large language models (LLMs), the Real-Twin tool, and multi-agent systems to perform realistic microscopic traffic simulation scenario generation. The proposed framework incorporates human-in-the-loop (HIL) control, retrieval-augmented generation (RAG), and multi-agent control mechanisms. HIL mechanisms are used to guide multiple LLMs focused on attributes for microscopic simulation generation and to improve the interpretability and transparency of LLM execution for users. RAG enhances context extraction by dynamically integrating external knowledge sources for traffic scenario generation foundations. A multi-agent architecture with supervisory control coordinates the interaction of simulation components, including traffic simulators, control logic, and calibration tools. This enables the synthesis of simulation-ready scenarios that reflect dynamic demand profiles and behavior controls. Furthermore, the framework fuses multisource traffic data with unstructured context and supports iterative refinement through interactive user feedback. Validated through microscopic simulation using Simulation of Urban Mobility, the generated scenarios demonstrate high-fidelity network generation with inflow and turn movement and behavioral calibration, offering a robust and efficient tool for stress-testing and optimizing urban mobility systems.

Hierarchical multi-agent control↗

CHESS 2025: Spectrometer orthorectified at-sensor radiance from NEON AOP imaging spectroscopy surveys

This dataset provides Level 1 (L1) orthorectified at-sensor radiance derived from measurements collected by the Imaging Spectrometer-1 (NIS-1) onboard the NEON (National Ecological Observatory Network) Airborne Observation Platform (AOP) for the 2025 Colorado Headwaters Ecological Spectroscopy Study (CHESS). NIS-1 captures light reflected from the Earth’s surface in 426 discrete wavelength bands as raw digital numbers (DNs; Level 0). These data are then calibrated to physical units (uW/cm²·sr·nm) following the processing steps described in the NEON Imaging Spectrometer Level 1B Calibrated Radiance Algorithm Theoretical Basis Document (ATBD; Gallery 2022). The data delivered here are the primary inputs for the surface reflectance product in “Custom surface reflectance, shade masks, and equivalent water thickness maps for the Colorado Headwaters Ecological Spectroscopy Study” (Carroll et al. 2026). For intertemporal comparison, the radiance data here are most directly relatable to the v2 radiance data in “NEON AOP Imaging Spectroscopy Survey of Upper East River Colorado Watersheds: Raw-Space Radiance and Observational Variable Dataset” (Goulden et al. 2018), to which the same processing methodology was applied. Together, the radiance and reflectance data enable users to exploit the unique reflection signatures of different surface objects for land cover classification, foliar trait mapping, plant vigor assessment, water content estimation, trace-element identification, and other scientific applications. The data were acquired over three study domains in the Upper Gunnison river basin: the upper East River watershed (CRBU); Almont Triangle and Taylor Canyon (ALMO); and Upper Taylor River watershed (UPTA) between 2025-06-13 and 2025-07-15. Within each domain, data are delivered by flightline as orthorectified and calibrated hyperspectral rasters in Hierarchical Data Format version 5 (HDF5) format, with radiance values provided in uW/cm²·sr·nm on a fixed, uniform Universal Transverse Mercator (UTM) grid at 1 meter spatial resolution. The radiance rasters include all 426 NIS-1 spectral bands, along with associated quality-assurance (QA) and diagnostic and ancillary layers needed for atmospheric correction workflows. Orthorectified radiance is produced from pushbroom spectrometer observations by applying NEON’s radiometric calibration (including bad pixel masking, dark subtract, dark pedestal shift correction, electronic panel ghost correction, grating ghost correction, deblur correction and flat-fielding) and spectral calibration (using spectral response function band centers and full-width at half-maximum intensity), followed by geolocation and regridding to the fixed grid. CHESS Project Description: The Colorado Headwaters Ecological Spectroscopy Study (CHESS) comprised a multi-week airborne remote sensing and field observation campaign in the Upper Gunnison Basin, Colorado, conducted in June and July of 2025. Airborne remote sensing was conducted by the National Ecological Observatory Network Airborne Observation Platform (NEON AOP), concurrent with a field campaign run by the Rocky Mountain Biological Laboratory (RMBL), the Lawrence Berkeley National Laboratory (LBNL) and SLAC National Accelerator Laboratory Watershed Function Science Focus Area (SFA), and NASA-JPL (Jet Propulsion Laboratory) Earth Surface Mineral Dust Source Investigation (EMIT) program. Between June 10 and July 18, 2025, the NEON AOP flight team collected high-resolution aerial imaging spectroscopy and Light Detection and Ranging (LiDAR) data over three domains: the Upper East River (CRBU), Almont Triangle (ALMO), and the Upper Taylor Basin (UPTA). In coordination with the flights, a field campaign acquired ground-truth observations, including observations of vegetation composition, foliar traits, forest demography, and subsurface properties in 18 core sampling areas within the domains. Additional surface water observations were taken at over 380 point locations. All CHESS campaign datasets can be found within the CHESS ESS-DIVE data portal: https://data.ess-dive.lbl.gov/portals/chess. Funding Acknowledgement: Field and remote-sensing data acquisition was performed under a grant from the National Aeronautics and Space Administration (80NSSC24K1005). This work was also supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

2018 NEON and 2025 CHESS Campaigns↗

Snow ALbedo eVOlution (SALVO) Campaign Spectral Albedo and Related Measurements from April - June, 2024 in Utqiagivk, AK

A field-portable spectroradiometer, referred to herein as an ‘ASD’, was used to make spatially-distributed spectral albedo (350 – 2500 nm) measurements on tundra and sea ice surfaces. The ASD detector is carried in a backpack and controlled via a computer mounted on the front of the operator (see Figure 1). The ASD measures the spectral irradiance from a fiber optic cable that is routed from the backpack to a custom, gooseneck cosine collector mounted on the end of a 1-m long boom (Grenfell and Perovich, 2008). The boom was held at hip height (approximately 1 m) and had an integrated bubble level for levelling. To make an albedo measurement, first the operator collect an incident (down-welling) irradiance, followed by a reflected (up-welling) measurement. The time between incident and reflected measurements was typically between 11 and 26 seconds (interquartile range). For each measurement, 10 spectra are averaged together. Albedo is calculated as the ratio of the reflected to incident measurement, which obviates the need for absolute radiometric calibration. Albedo measurements were taken parallel to the 200-m albedo lines at 5-m increments (41 measurements) ~1 m south of the line. While the ASD operator was making measurements, an assistant kept notes on the scan number associated with each measurement, the surface type (see below), and collected photos of each measurement (see companion oblique photos data archive). Measurements were made within 3 hours of solar noon.

ASD Spectroradiometer↗

Toward inverse backscatter absorption gas imaging: imaging a dry gas plume with ambient H 2 O absorption

This paper introduces inverse backscatter absorption gas imaging (iBAGI), a transparent gas imaging technique based on absorption spectroscopy of gases naturally present in ambient air being displaced by transparent gases. We demonstrate reconstruction of a 2-D image of a dry gas plume by measuring light of a raster-scanned diode laser tuned to an absorption line of atmospheric H 2 O. We quantify the performance depending on the distance to the backdrop and show that the key transmission metric is independent of absorption path length. We conclude with an outlook toward calibration-free, single-ended iBAGI using scattering from low-reflectivity backdrops.

Klug, Joseph C.↗

Model Gap Quantification and Evaluation

In the real world, model gaps always exist because models cannot perfectly match the objective physical plants. Model gaps reflect the integrity of models, which is vital for model validation and calibration. This letter proposes a novel approach for model gap quantification and evaluation. First, a comprehensive metric is developed to quantify dynamic model gaps. Next, the model gaps are evaluated from a panoramic view of the probability distribution of the comprehensive metric for multiple scenarios. Finally, we demonstrate the proposed quantification and evaluation approach through synchronous machine models.

Wang, Shaobu↗

X-ray sources for in situ wavelength calibration of x-ray imaging crystal spectrometers

X-ray sources for a range of wavelengths are being considered for in situ calibration of X-ray Imaging Crystal Spectrometers (XICSs) and for monitoring line shifts due to changes in the crystal temperature, which can vary during experimental operation over a day [A. Ince-Cushman et al., Rev. Sci. Instrum. 79, 10E302 (2008), L. Delgado-Aparicio et al., Plasma Phys. Control. Fusion 55, 125011 (2013)]. Such crystal temperature dependent shifts, if not accounted for, could be erroneously interpreted as Doppler shifts leading to errors in plasma flow-velocity measurements. The x-ray sources encompass characteristic x-ray lines falling within the wavelength range of 0.9–4.0 Å, relevant for the XICSs on present and future fusion devices. Several technological challenges associated with the development of x-ray sources for in situ calibration are identified and are being addressed in the design of multiple x-ray tubes, which will be installed inside the spectrometer housing of the XICS for the JT-60SA tokamak. These x-ray sources will be especially useful for in situ calibration between plasma discharges. Here, in this paper, laboratory experiments are described that were conducted with a Cu x-ray source, a heated quartz (102) crystal, and a pixelated Pilatus detector to measure the temperature dependent shifts of the Cu Kα 1 and Kα 2 lines at 1.5405 and 1.5443 Å, respectively, and to evaluate the 2d-lattice constant for the Bragg reflecting crystal planes as a function of temperature, which, in the case of in situ wavelength calibration, would have to be used for numerical analysis of the x-ray spectra from the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using probabilistic solar power forecasts to inform flexible ramp product procurement for the California ISO

How can independent system operators (ISOs) take advantage of probabilistic solar forecasts to lower generation costs and improve reliability of power systems? We discuss one three-step approach for doing so, focusing on how such forecasts might help the California Independent System Operator (CAISO) prepare unexpected net load ramps, where net load equals gross demand minus wind and solar production. First, we enhance an existing solar forecasting system to provide well-calibrated hours-ahead probabilistic forecasts. We then relate the degree of uncertainty reflected in the forecasted prediction intervals (independent variables) to error distributions for net load ramp forecasts for the CAISO real-time market (dependent variable) using machine learning and quantile regression. Projected ramp forecast errors conditioned on solar uncertainty are translated into flexible ramp requirements that therefore reflect real-time meteorological and solar conditions, improving on typical ISO procedures. Detailed descriptions are provided on the quantile regression and kth-nearest neighbor categorization methods for accomplishing that translation. Finally, a multiple time-scale look-ahead market simulation model is applied to a 118-bus IEEE Reliability Test System, modified to represent the CAISO generation mix and demand distributions. The model runs quantify how solar-conditioned ramp requirements can, first, decrease operating costs by reducing requirements compared to often conservative unconditional methods and, second, decrease generation scarcity events and consequently improve reliability by increasing flexibility requirements at times when unconditional forecast-based requirements understate actual ramp uncertainty. Solar-conditioned ramp requirements are found to reduce generation operating costs by about 2% for the test system (which would be equivalent to over $\$100$ million per year for a CAISO-size system).

14 SOLAR ENERGY↗

Standard Operating Procedure for Optimal Deployment of Meteorological Instrumentation Within the Solar Radiation Research Laboratory: 2024 Edition

The objective of the National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) is to collect and use high-quality solar radiation data sets for research leading to the widespread adoption of solar technologies. To appropriately populate and track the diverse array of instruments at the NREL-SRRL, NREL has established a Standard Operating Procedure (SOP) for optimal instrument deployment within the SRRL for both the Baseline Measurement System (BMS) and the Research Measurement System (RMS). Using best practices methodologies, the NREL-SRRL maintains a varied and extensive array of solar monitoring equipment to test, evaluate, and characterize the solar sensors used by federal and international agencies as well as the solar industry to determine the solar resource. The SOP provides the industry with guidance for solar resource assessment and is used for procedures in the long-term continuous monitoring of legacy instruments alongside state-of-the-art instruments. Based on the SOP, instruments are annually evaluated for continued deployment. Instruments that do not meet the SOP criteria are decommissioned, and new instruments that meet the criteria are deployed. Streamlining and optimizing the use of this facility ensures that the lab continues to be a world-leading solar calibration and measurement facility. This 2024 edition includes updates to the appendices to reflect the instrument changes from one year to another.

14 SOLAR ENERGY↗

An Adaptive Reference Scheme to Extend the Functional Range of Optical Backscatter Reflectometry in Extreme Environments

Optical frequency domain reflectometry (OFDR) measurements are performed by recording the interference pattern of light backscattered by density fluctuations or Bragg gratings along the length of an optical fiber. Changes in local temperature or strain in the fiber cause shifts in the backscattered light spectrum, which can be calibrated to the applied temperature or strain. Comparing the backscattered optical spectra from each reflection site with a reference (unstrained) spectrum allows for quantification of local spectral shifts. While mature OFDR-based technologies can provide high-precision spatially distributed measurements over kilometer lengths, the post-processing approaches used to recover spectral shifts from raw optical intensity data can limit the use of OFDR in harsh environments. This paper presents a novel approach to post-processing OFDR data which extends the usability of optical fibers exposed to harsh environments. This approach is the first to use the spectral shift quality, calculated for two OFDR measurements, to identify an appropriate reference scan from which the spectral shift can be determined. Here, three experimental data sets are used to test the algorithm: (1) an optical fiber heated to >950°C, (2) an aluminum-embedded optical fiber under strain from differential thermal expansion, and (3) an optical fiber exposed to a total neutron flux of 2×10 13 n/cm 2 /s over 40 hours in a nuclear test reactor. Results show that using a metric of quality to select an appropriate reference measurement extends the functional range of OFDR strain and temperature sensors. Furthermore, this algorithm can be applied to existing OFDR data.

47 OTHER INSTRUMENTATION↗