Search NASA⌕ Search

SEARCH · Search NASA

Results for “resolution quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

MPAS - Ocean Simulation Quality for Variable-Resolution North American Coastal Meshes

Climate model components utilizing unstructured meshes enable variableresolution, regionally enhanced simulations within global domains. Here we investigate the relationship between mesh quality and simulation statistics using the JIGSAW unstructured meshing library and the Model for Prediction Across ScalesOcean (MPASOcean) with a focus on Gulf Stream dynamics. In the base configuration, the refined region employs 8 km cells that extend 400 km from the coast of North America. This coastal refined region is embedded within a lowresolution global domain, with cell size varying latitudinally between 30 and 60 km. The resolution transition region between the refined region and background mesh is 600 km wide. Three sensitivity tests are conducted: 1) the quality of meshes is intentionally degraded so that horizontal cells are progressively more distorted; 2) the transition region from high to low resolution is steepened; and 3) resolution of the coastal refinement region is varied from 30 km to 8 km. Overall, the ocean simulations are shown to be robust to mesh resolution and quality alterations. Meshes that are substantially degraded still produce realistic currents, with Southern Ocean transports within 0.4% and Gulf Stream transports within 12% of highquality mesh results. The narrowest transition case of 100 km did not produce any spurious effects. Refined regions with high resolution produce eddy kinetic energy and sea surface height variability that are similar to the highresolution reference simulation. These results provide heuristics for the design criteria of variableresolution climate model domains.

Hoch, Kristin E.↗

Momentum resolution in inverse photoemission

We present a method to determine the electron beam divergence, and thus the momentum resolution, of an inverse-photoemission setup directly from a series of spectra measured on Cu(111). Simulating these spectra with different beam divergences shows a distinct influence of the divergence on the appearance of the Shockley surface state. Upon crossing the Fermi level, its rise in intensity can be directly linked with the beam divergence. A comparison of measurement and simulation enables us to quantify the momentum resolution independent of surface quality, energy resolution, and experimental geometry. With spin resolution, a single spectrum taken around the Fermi momentum of a spin-split surface state, e.g., on Au(111), is sufficient to derive the momentum resolution of an inverse-photoemission setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of a line-pair resolution phantom for comprehensive quality assurance of electronic portal imaging devices based on fundamental imaging metrics

Image guided radiation therapy solutions based on megavoltage computed tomography (MVCT) involve the extension of electronic portal imaging devices (EPIDs) from their traditional role of weekly localization imaging and planar dose mapping to volumetric imaging for 3D setup and dose verification. To sustain the potential advantages of MVCT, EPIDs are required to provide improved levels of portal image quality. Therefore, it is vital that the performance of EPIDs in clinical use is maintained at an optimal level through regular and rigorous quality assurance (QA). Traditionally, portal imaging QA has been carried out by imaging calibrated line-pair and contrast resolution phantoms and obtaining arbitrarily defined QA indices that are usually dependent on imaging conditions and merely indicate relative trends in imaging performance. They are not adequately sensitive to all aspects of image quality unlike fundamental imaging metrics such as the modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) that are widely used to characterize detector performance in radiographic imaging and would be ideal for QA purposes. However, due to the difficulty of performing conventional MTF measurements, they have not been used for routine clinical QA. The authors present a simple and quick QA methodology based on obtaining the MTF, NPS, and DQE of a megavoltage imager by imaging standard open fields and a bar-pattern QA phantom containing 2 mm thick tungsten line-pair bar resolution targets. Our bar-pattern based MTF measurement features a novel zero-frequency normalization scheme that eliminates normalization errors typically associated with traditional bar-pattern measurements at megavoltage x-ray energies. The bar-pattern QA phantom and open-field images are used in conjunction with an automated image analysis algorithm that quickly computes the MTF, NPS, and DQE of an EPID system. Our approach combines the fundamental advantages of linear systems metrics such as robustness, sensitivity across the full spatial frequency range of interest, and normalization to imaging conditions (magnification, system gain settings, and exposure), with the simplicity, ease, and speed of traditional phantom imaging. The algorithm was analyzed for accuracy and sensitivity by comparing with a commercial portal imaging QA method (PIPSPRO, Standard Imaging, Middleton, WI) on both first-generation lens-coupled and modern a-Si flat-panel based clinical EPID systems. The bar-pattern based QA measurements were found to be far more sensitive to even small levels of degradation in spatial resolution and noise. The bar-pattern based QA methodology offers a comprehensive image quality assessment tool suitable for both commissioning and routine EPID QA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thematic Mapper image quality - Registration, noise, and resolution

The Landsat-4 satellite has two new imaging radiometers, including the redesigned Multispectral Scanner (MSS) and the Thematic Mapper (TM). The present investigation is concerned with an assessment of TM image quality on the basis of a study of band-to-band registration, periodic noise, and spatial resolution. In the TM images analyzed, the band-to-band registration accuracy of the instrument is very good. A few imperfections were found. Once a stable misregistration is removed, the TM should also meet its registration specifications between focal planes. Spatial resolution analyses in terms of MTF were performed in comparison modes. The forward and backward scans were shown to have virtually identical MTFs.

Wrigley, R. C.↗

U.S. Government Open Internet Access to Sub-meter Satellite Data

The National Geospatial-Intelligence Agency (NGA) has contracted United States commercial remote sensing companies GeoEye and Digital Globe to provide very high resolution commercial quality satellite imagery to federal/state government agencies and those projects/people who support government interests. Under NextView contract terms, those engaged in official government programs/projects can gain online access to NGA's vast global archive. Additionally, data from vendor's archives of IKONOS-2 (IK-2), OrbView-3 (OB-3), GeoEye-1 (GE-1), QuickBird-1 (QB-1), WorldView-1 (WV-1), and WorldView-2 (WV-2), sensors can also be requested under these agreements. We report here the current extent of this archive, how to gain access, and the applications of these data by Earth science investigators to improve discoverability and community use of these data. Satellite commercial quality imagery (CQI) at very high resolution (< 1 m) (here after referred to as CQI) over the past decade has become an important data source to U.S. federal, state, and local governments for many different purposes. The rapid growth of free global CQI data has been slow to disseminate to NASA Earth Science community and programs such as the Land-Cover Land-Use Change (LCLUC) program which sees potential benefit from unprecedented access. This article evolved from a workshop held on February 23rd, 2012 between representatives from NGA, NASA, and NASA LCLUC Scientists discussion on how to extend this resource to a broader license approved community. Many investigators are unaware of NGA's archive availability or find it difficult to access CQI data from NGA. Results of studies, both quality and breadth, could be improved with CQI data by combining them with other moderate to coarse resolution passive optical Earth observation remote sensing satellites, or with RADAR or LiDAR instruments to better understand Earth system dynamics at the scale of human activities. We provide the evolution of this effort, a guide for qualified user access, and describe current to potential use of these data in earth science.

Neigh, Christopher S. R>↗

Sensor-Equipped Unmanned Surface Vehicle for High-Resolution Mapping of Water Quality in Low- to Mid-Order Streams

Longitudinal profiling of water quality via the deployment of sensors from watercraft has advanced the understanding of spatial patterns in large rivers and lakes; however, a similar approach in low- to mid-order streams is lacking. To fill this gap, we developed an unmanned surface vehicle (USV)-water quality measurement platform (the “AquaBOT”). The components of the AquaBOT included a nitrate sensor, multiparameter sonde (temperature, conductivity, turbidity, dissolved oxygen, chlorophyll), quantum sensor, and global positioning system (GPS) mounted to a small pontoon-style USV. The AquaBOT was tested in four streams and rivers in Iowa and Tennessee. All measured water quality parameters varied longitudinally, and greater ranges were generally observed along the low-order, agriculturally influenced streams in Iowa. Nitrate, in particular, was spatially heterogeneous. For example, during one run in early June, concentrations ranged from 10.5 to 12.5 mg N L –1 along a 2.3 km reach and hotspots were observed directly downstream of some tile drains. The spatial resolution of AquaBOT data collected in June was 10× higher than grab sampling data, and measurements were collected in less time and at a comparable cost. Here, the AquaBOT can complement existing measurement approaches and will lead to advancements in understanding the processes driving water quality along the stream-to-river continuum.

47 OTHER INSTRUMENTATION↗

Phase contrast tomography of the mouse cochlea at microfocus x-ray sources

We present phase contrast x-ray tomography of functional soft tissue within the bony cochlear capsule of mice, carried out at laboratory microfocus sources with well-matched source, detector, geometry, and reconstruction algorithms at spatial resolutions down to 2 μm. Contrast, data quality and resolution enable the visualization of thin membranes and nerve fibers as well as automated segmentation of surrounding bone. By complementing synchrotron radiation imaging techniques, a broad range of biomedical applications becomes possible as demonstrated for optogenetic cochlear implant research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A High-Quality Workflow for Multi-Resolution Scientific Data Reduction and Visualization

Multi-resolution methods such as Adaptive Mesh Refinement (AMR) can enhance storage efficiency for HPC applications generating vast volumes of data. However, their applicability is limited and cannot be universally deployed across all applications. Furthermore, integrating lossy compression with multi-resolution techniques to further boost storage efficiency encounters significant barriers. To this end, we introduce an innovative workflow that facilitates high-quality multi-resolution data compression for both uniform and AMR simulations. Initially, to extend the usability of multi-resolution techniques, our workflow employs a compression-oriented Region of Interest (ROI) extraction method, transforming uniform data into a multi-resolution format. Subsequently, to bridge the gap between multi-resolution techniques and lossy compressors, we optimize three distinct compressors, ensuring their optimal performance on multi-resolution data. These optimizations can improve the compression ratio of SOTA approaches by up to 3.3× under the same data quality loss. Lastly, we incorporate an advanced uncertainty visualization method into our workflow to understand the potential impacts of lossy compression. Experimental evaluation demonstrates that our workflow achieves significant compression quality improvements.

Wang, Daoce↗

High Resolution Aerosol Data from MODIS Satellite for Urban Air Quality Studies

The Moderate Resolution Imaging Spectroradiometer (MODIS) provides daily global coverage, but the 10 km resolution of its aerosol optical depth (AOD) product is not suitable for studying spatial variability of aerosols in urban areas. Recently, a new Multi-Angle Implementation of Atmospheric Correction (MAIAC) algorithm was developed for MODIS which provides AOD at 1 km resolution. Using MAIAC data, the relationship between MAIAC AOD and PM(sub 2.5) as measured by the 27 EPA ground monitoring stations was investigated. These results were also compared to conventional MODIS 10 km AOD retrievals (MOD04) for the same days and locations. The coefficients of determination for MOD04 and for MAIAC are R(exp 2) =0.45 and 0.50 respectively, suggested that AOD is a reasonably good proxy for PM(sub 2.5) ground concentrations. Finally, we studied the relationship between PM(sub 2.5) and AOD at the intra-urban scale (10 km) in Boston. The fine resolution results indicated spatial variability in particle concentration at a sub-10 kilometer scale. A local analysis for the Boston area showed that the AOD-PM(sub 2.5) relationship does not depend on relative humidity and air temperatures below approximately 7 C. The correlation improves for temperatures above 7 - 16 C. We found no dependence on the boundary layer height except when the former was in the range 250-500 m. Finally, we apply a mixed effects model approach to MAIAC aerosol optical depth (AOD) retrievals from MODIS to predict PM(sub 2.5) concentrations within the greater Boston area. With this approach we can control for the inherent day-to-day variability in the AOD-PM(sub 2.5) relationship, which depends on time-varying parameters such as particle optical properties, vertical and diurnal concentration profiles and ground surface reflectance. Our results show that the model-predicted PM(sub 2.5) mass concentrations are highly correlated with the actual observations (out-of-sample R(exp 2) of 0.86). Therefore, adjustment for the daily variability in the AOD-PM(sub 2.5) relationship provides a means for obtaining spatially-resolved PM(sub 2.5) concentrations.

remote sensing↗

Ligand placement based on prior structures: the guided ligand-replacement method

A new module, Guided Ligand Replacement (GLR), has been developed in Phenix to increase the ease and success rate of ligand placement when prior protein-ligand complexes are available. The process of iterative structure-based drug design involves the X-ray crystal structure determination of upwards of 100 ligands with the same general scaffold (i.e. chemotype) complexed with very similar, if not identical, protein targets. In conjunction with insights from computational models and assays, this collection of crystal structures is analyzed to improve potency, to achieve better selectivity and to reduce liabilities such as absorption, distribution, metabolism, excretion and toxicology. Current methods for modeling ligands into electron-density maps typically do not utilize information on how similar ligands bound in related structures. Even if the electron density is of sufficient quality and resolution to allow de novo placement, the process can take considerable time as the size, complexity and torsional degrees of freedom of the ligands increase. A new module, Guided Ligand Replacement (GLR), was developed in Phenix to increase the ease and success rate of ligand placement when prior protein–ligand complexes are available. At the heart of GLR is an algorithm based on graph theory that associates atoms in the target ligand with analogous atoms in the reference ligand. Based on this correspondence, a set of coordinates is generated for the target ligand. GLR is especially useful in two situations: (i) modeling a series of large, flexible, complicated or macrocyclic ligands in successive structures and (ii) modeling ligands as part of a refinement pipeline that can automatically select a reference structure. Even in those cases for which no reference structure is available, if there are multiple copies of the bound ligand per asymmetric unit GLR offers an efficient way to complete the model after the first ligand has been placed. In all of these applications, GLR leverages prior knowledge from earlier structures to facilitate ligand placement in the current structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-F-T-429: Craniospinal Irradiation by VMAT Technique: Impact of FFF Beam and High Resolution MLC On Plan Quality

Purpose: Objective of this study was to evaluate the impact of using flattening filter free (FFF) beam with 0.5 cm multileaf collimator (MLC) leaves over conventional flattened beam with 1 cm leaf width MLC on the treatment plan quality in cranio-spinal irradiation (CSI). Methods: For five medulloblastoma cases (3 males and 2 females), who were previously treated by volumetric modulated arc therapy (VMAT) technique using conventional flattened beam shaped by 1 cm width MLC leaves, four test plans were generated and compared against the delivered plan. These retrospective plans consisted of four different combinations of flattened and FFF beams from Elekta’s Agility treatment head with 0.5 cm width MLC leaves. Sparing of organs at risks (OAR) in terms of dose to 5%, 50%, 75% and 90% volumes, mean and maximum dose were evaluated. Results: All plans satisfied the planning objective of covering 95% of PTV by at least 95% of prescription dose. Marginal variation of dose spillage was observed between different VMAT plans at very low dose range (1–5 Gy). Variation in dose statistics for PTVs and OARs were within 1% or 1 Gy. Amongst the five plans, the plan with flattened beam with 1 cm MLC had the highest number of MUs, 2.13 times higher than the plan with Agility MLC with FFF beam that had the least number of MUs. No statistically significant difference (p≥0.05) was observed between the reference plan and the retrospectively generated plans in terms of PTV coverage, cold spot, hot spot and organ at risk doses. Conclusion: In the treatment of CSI cases by VMAT technique, FFF beams and/or finer width MLC did not exhibit advantage over the flattened beams or wider MLC in terms of plan quality except for reduction in MUs.

60 APPLIED LIFE SCIENCES↗

Supporting Global Air Quality Management Needs With A Flexible Data Fusion Tool for Estimation and Forecasting in Google Earth Engine

High spatial and temporal resolution air quality estimation and forecasting can be enhanced by combining global data sources, like chemical transport models and satellite remote sensing, with local information from regulatory and low-cost air quality monitors. Successful integration of data from these diverse sources is complicated by many factors, however, including differences in spatial and temporal resolution, data availability and latency issues, varying data quality, and large computational and data storage requirements. This presentation will provide an overview of a NASA-funded effort to develop the foundation for future operationalization of air quality forecasting for world-wide end-users and integration into their air quality management decision processes, which will be achieved in future phases of this multi-year project. We will summarize our progress in developing a data fusion system using the Google Earth Engine platform which can integrate model, satellite, and surface-level monitoring datasets to enhance estimation and forecasting of air-quality-relevant pollutants at sub-daily and sub-city scales. The tool is being developed in close cooperation with several city- and regional-level air quality managers in the USA and around the world. Our end-goal is to provide these air quality managers with the information they need to assess and anticipate the impacts of poor air quality, track changes in air quality due to ongoing mitigation efforts and land use changes, and identify ways to improve their air quality monitoring strategies. This presentation will focus on recent advances achieved through the project, including integration of multiple air quality datasets in a prototype data fusion system in Google Earth Engine, the quantification of uncertainties associated with our data fusion approach, and the development of user interfaces and visualization tools to convey air quality information in a way which best meets end-user needs.

Carl Malings↗

Supporting Global Air Quality Management Needs With A Flexible Data Fusion Tool for Estimation and Forecasting in Google Earth Engine

High spatial and temporal resolution air quality estimation and forecasting can be enhanced by combining global data sources, like chemical transport models and satellite remote sensing, with local information from regulatory and low-cost air quality monitors. Successful integration of data from these diverse sources is complicated by many factors, however, including differences in spatial and temporal resolution, data availability and latency issues, varying data quality, and large computational and data storage requirements. This presentation will provide an overview of a NASA-funded effort to develop the foundation for future operationalization of air quality forecasting for world-wide end-users and integration into their air quality management decision processes, which will be achieved in future phases of this multi-year project. We will summarize our progress in developing a data fusion system using the Google Earth Engine platform which can integrate model, satellite, and surface-level monitoring datasets to enhance estimation and forecasting of air-quality-relevant pollutants at sub-daily and sub-city scales. The tool is being developed in close cooperation with several city- and regional-level air quality managers in the USA and around the world. Our end-goal is to provide these air quality managers with the information they need to assess and anticipate the impacts of poor air quality, track changes in air quality due to ongoing mitigation efforts and land use changes, and identify ways to improve their air quality monitoring strategies. This presentation will focus on recent advances achieved through the project, including integration of multiple air quality datasets in a prototype data fusion system in Google Earth Engine, the quantification of uncertainties associated with our data fusion approach, and the development of user interfaces and visualization tools to convey air quality information in a way which best meets end-user needs.

Carl Malings↗

ML Classifier Fusion for Three Data Streams with Quality Inversely Proportional to Time Resolution

We consider a monitoring scenario of phenomenon using three different streams of measurements whose quality is proportional to their constant inter-arrival times. Each measurement of a stream needs to be binary-classified to reflect the state of interest of the phenomenon. A set of classifiers is separately trained and fused for each stream at its time resolution using measurements collected under known states. We present a machine learning method to fuse the outputs of these fusers to provide a final classification at the finest time resolution. We show that this fused-fusers method provides decisions with likely superior classification probability compared to the best individual classifiers and fused-classifiers. We derive generalization equations that guarantee a superior classification probability of fused-fusers with a confidence probability specified by the classifiers’ generalization equations. We apply these results to study a practical problem of classifying Pu/Np target dissolution events at a radiochemical processing facility using gamma spectral measurements of effluent flows.

Rao, Nageswara↗

Molecular Surface Sampling and Chemical Imaging using Proximal Probe Thermal Desorption/Secondary Ionization Mass Spectrometry

Proximal probe thermal desorption/secondary ionization mass spectrometry was studied and applied to molecular surface sampling and chemical imaging using printed patterns on photopaper as test substrates. With the use of a circular cross section proximal probe with a tip diameter of 50 m and fixed temperature (350 C), the influence of probe-to-surface distance, lane scan spacing, and surface scan speed on signal quality and spatial resolution were studied and optimized. As a compromise between signal amplitude, signal reproducibility, and data acquisition time, a surface scan speed of 100 m/s, probe-to-paper surface distance of 5 m, and lane spacing of 10 m were used for imaging. Under those conditions the proximal probe thermal desorption/secondary ionization mass spectrometry method was able to achieve a spatial resolution of about 50 m as determined by the ability to distinguish surface patterns of known dimensions that were printed on the paper substrate. It is expected that spatial resolution and chemical image quality could be further improved by using probes of smaller cross section size and by incorporating a means to maintain a fixed optimal probe-to-surface distance real time, continuously adapting to the changing topography of the surface during a lane scan.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detecting breast microcalcifications using super-resolution and wave-equation ultrasound imaging: a numerical phantom study

Ultrasound image resolution and quality need to be significantly improved for breast microcalcification detection. Super-resolution imaging with the factorization method has recently been developed as a promising tool to break through the resolution limit of conventional imaging. In addition, wave-equation reflection imaging has become an effective method to reduce image speckles by properly handling ultrasound scattering/diffraction from breast heterogeneities during image reconstruction. We explore the capabilities of a novel super-resolution ultrasound imaging method and a wave-equation reflection imaging scheme for detecting breast microcalcifications. Super-resolution imaging uses the singular value decomposition and a factorization scheme to achieve an image resolution that is not possible for conventional ultrasound imaging. Wave-equation reflection imaging employs a solution to the acoustic-wave equation in heterogeneous media to backpropagate ultrasound scattering/diffraction waves to scatters and form images of heterogeneities. We construct numerical breast phantoms using in vivo breast images, and use a finite-difference wave-equation scheme to generate ultrasound data scattered from inclusions that mimic microcalcifications. We demonstrate that microcalcifications can be detected at full spatial resolution using the super-resolution ultrasound imaging and wave-equation reflection imaging methods.

59 BASIC BIOLOGICAL SCIENCES↗

International Collaboration Framework for the Calculation of Performance Loss Rates: Data Quality, Benchmarks, and Trends

Within the IEA PVPS Task 13, a group of experts representing several leading R&D centres, universities and industry companies, is developing a framework for the calculation of Performance Loss Rates (PLR) on a large number of commercial and research PV power plants and related weather data coming from various climatic zones. Various methodologies are applied for the calculation of PLR which are benchmarked in terms of uncertainties and 'true' values. The aim of the international collaboration is to show how to calculate the PLR on high quality (high time resolution, reliable data, irradiance, yield, etc.) and on low quality data (low time resolution, only energy data available). Various algorithms and models, along with different time averaging and filtering criteria, can be applied for the calculation of PLR each of which can have an impact on the results. The approach considers three pathways to ensure broad collaboration and increase the statistical relevance of the study: i) use of shared methodologies on shared time series, ii) use of confidential methodologies on shared time series, iii) use of shared methodologies on confidential time series. The data is used for benchmarking activities and to define which methodologies clusters around a 'true value' of PLR. The combination of metrics (PR or power based) and methodologies are benchmarked in terms of deviation from the average value and in terms of standard deviation. The combination of temperature corrected PR with the use of Year on Year (YOY) or Seasonal Trend decomposition using Loess (STL) performs well for all systems; other methodologies seems to be more depending on the filtering applied. Another set of data is represented by the IEA PVPS Task 13 'PV performance database' which includes more than 120 PV plants from different climates. The applied methodologies were STL and the YoY approach. STL results in an averaged PLR over all systems of -0.78%/a while YoY yields -0.63%/a. STL is better suited if the time series data are of higher resolution and high-quality weather data are available. One important outcome of this study is the setting of a framework for the contribution to a clear and structured quality classification for PV time series data and a guideline for PLR calculations in dependency of the data categorization.

14 SOLAR ENERGY↗

Improved Satellite Retrievals of NO2 and SO2 over the Canadian Oil Sands and Comparisons with Surface Measurements

Satellite remote sensing is increasingly being used to monitor air quality over localized sources such as the Canadian oil sands. Following an initial study, significantly low biases have been identified in current NO2 and SO2 retrieval products from the Ozone Monitoring Instrument (OMI) satellite sensor over this location resulting from a combination of its rapid development and small spatial scale. Air mass factors (AMFs) used to convert line-of-sight "slant" columns to vertical columns were re-calculated for this region based on updated and higher resolution input information including absorber profiles from a regional-scale (15 km × 15 km resolution) air quality model, higher spatial and temporal resolution surface reflectivity, and an improved treatment of snow. The overall impact of these new Environment Canada (EC) AMFs led to substantial increases in the peak NO2 and SO2 average vertical column density (VCD), occurring over an area of intensive surface mining, by factors of 2 and 1.4, respectively, relative to estimates made with previous AMFs. Comparisons are made with long-term averages of NO2 and SO2 (2005-2011) from in situ surface monitors by using the air quality model to map the OMI VCDs to surface concentrations. This new OMI-EC product is able to capture the spatial distribution of the in situ instruments (slopes of 0.65 to 1.0, correlation coefficients of greater than 0.9). The concentration absolute values from surface network observations were in reasonable agreement, with OMI-EC NO2 and SO2 biased low by roughly 30%. Several complications were addressed including correction for the interference effect in the surface NO2 instruments and smoothing and clear-sky biases in the OMI measurements. Overall these results highlight the importance of using input information that accounts for the spatial and temporal variability of the location of interest when performing retrievals.

surface concentration↗