53 records · Page 3

Oxygen vacancies in niobium pentoxide as a source of two-level system losses in superconducting niobium

We identify a major source of quantum decoherence in three-dimensional superconducting radio-frequency (SRF) resonators and two-dimensional transmon qubits composed of oxidized niobium: oxygen vacancies in the niobium pentoxide, which drive two-level system (TLS) losses. By probing the effect of sequential in situ vacuum-baking treatments on the rf performance of bulk Nb SRF resonators and on the oxide structure of a representative Nb sample using TOF SIMS, we find a nonmonotonic evolution of cavity quality factor Q 0 , which correlates with the interplay of Nb 2 O 5 vacancy generation and oxide-thickness reduction. We localize this effect to the oxide itself and present the insignificant role of diffused interstitial oxygen in the underlying Nb by regrowing the oxide via wet oxidation, which reveals a mitigation of aggravated TLS losses. We hypothesize that such vacancies in the pentoxide serve as magnetic impurities and are a source of TLS-driven rf loss.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Oxygen Vacancies in Niobium Pentoxide as a Source of Two-Level System Losses in Superconducting Niobium

We identify a major source of quantum decoherence in three-dimensional superconducting radio-frequency (SRF) resonators and two-dimensional transmon qubits composed of oxidized niobium: oxygen vacancies in the niobium pentoxide, which drive two-level system (TLS) losses. By probing the effect of sequential in situ vacuum-baking treatments on the rf performance of bulk Nb SRF resonators and on the oxide structure of a representative Nb sample using TOF SIMS, we find a nonmonotonic evolution of cavity quality factor Q0, which correlates with the interplay of Nb2O5 vacancy generation and oxide-thickness reduction. We localize this effect to the oxide itself and present the insignificant role of diffused interstitial oxygen in the underlying Nb by regrowing the oxide via wet oxidation, which reveals a mitigation of aggravated TLS losses. We hypothesize that such vacancies in the pentoxide serve as magnetic impurities and are a source of TLS-driven rf loss.

Bafia, Daniel P. [Fermilab]↗

Robotic Systems integration for cleanroom SRF assembly at Fermilab

Superconducting Radio Frequency (SRF) cryomodule assembly is a critical process that demands the highest levels of contamination control in a cleanroom to ensure product quality and reliability. Within the cleanroom environment, human-driven activities remain the major source of uncontrolled particulate. Moreover, the precise manual alignment of components often exceeds expected timeframes, increasing the risk of particulate migration into the critical inner space of the SRF resonant cavity, and causing extended discomfort for workers. Automation comes as a natural solution to address these challenges. The goal of this activity is to set up and integrate a robotic system to support cavity coupler installation in the cleanroom environment. Initially, remote control of a 6-axis collaborative robot arm will be implemented as an introductory step towards automation in the cleanroom. Subsequently, the system will be further enhanced by integrating manipulation capabilities through an appropriate end-effector, and computer vision technology to enable accurate pose estimation. This comprehensive approach aims to achieve a fully automated and adaptable assembly process in the partially structured cleanroom environment, thereby enhancing efficiency and mitigating existing challenges for better product quality and workers safety.

42 ENGINEERING↗

Nb3Sn Coating of Twin Axis Cavity and Other Complex SRF Cavity Structures

In the field of Accelerator Science, for the low cost and increased quality factor, thin films coated niobium cavities are used in the modern SRF research. Within the potential substances, Nb3Sn has shown higher critical temperature than niobium. Here the tin vapor diffusion method is used as the preferred technique to coat niobium cavities. So far, only elliptical cavities have been coated with Nb3Sn and this technique has not yet been applied to cavities with complex geometries, which are also helpful in the accelerator science field. The Half-wave resonator could provide us data across frequencies of interest for particle accelerators world wide. Similarly the Twin axis cavity proposed for Energy Recovary Linac (ERL) applications could benefit from Nb3Sn coating. But with their advanced geometries, increased area, more number of ports and hard to reach areas, a different coating approach is needed to provide a uniform coating of Nb3Sn. We used twin axis cavity to optimize the coating technique and followed a low temperature annealing to further improvement of the thin film quality by low temperature annealing as a post coating method. With these we could expand the current coating system at JLab to coat complex cavity models

Tiskumara, Jayendrika↗

MULTI-TECHNIQUE CHARACTERIZATION OF SUPERCONDUCTING MATERIALS FOR PARTICLE ACCELERATOR APPLICATIONS

We investigated the performance limitations of superconducting radio-frequency (SRF) cavities and materials using multiple experimental techniques. In particular, this study focuses on understanding the surface properties of nitrogen-doped Nb cavities and super?conducting thin films with higher Tc such as Nb3Sn. The main goal of this work is to use different techniques to better understand each aspect of the complex loss mechanism in superconductors to further improve the already highly efficient SRF cavities. Nitrogen doping applied to a Nb SRF cavity significantly improves the quality factor Q0 compared to a conventional Nb cavity, at an expense of reduced maximum accelerating gradient. The early quench mechanism was analyzed by using temperature maps before and during the quenching. The temperature maps revealed insignificant heating before the quench, and we concluded that nitrogen doping reduces critical magnetic fields in local regions, leading to premature quenching. To understand the origin of the increasing Q0 with the rf field, the density of states (DOS) of cold spots from nitrogen-doped and standard cavities were measured and analyzed using scanning tunneling microscopy. The results suggested that nitrogen doping reduces the spatial inhomogeneity of superconducting properties and shrinks the metallic suboxide layers, which tunes the DOS in such a way as to produce the field-induced reduction in the surface resistance. To characterize SRF thin films, an experimental setup for measuring a coplanar waveguide (CPW) resonator was developed and tested. A surface impedance measurement of the Nb film showed good agreement with the BCS calculation. The preliminary results from measurements of Nb3Sn and NbTiN films are also presented here. The nonlinear Meissner effect was investigated in Nb3Sn film CPW resonators by mea?suring the resonant frequency as a function of a parallel magnetic field. Contrary to a conventional quadratic dependence of the penetration depth ?(B) on the applied magnetic field B, as expected in s-wave superconductors, nearly a linear increase of ?(B) with B was observed. It was concluded that this behavior of ?(B) is due to weakly linked grain bound?aries on the polycrystalline Nb3Sn films, which can mimic the NLME expected in a clean d-wave superconductor.

Makita, Junki↗

Niobium to Titanium Electron Beam Welding for SRF Cavities

Titanium and niobium are the main materials used for the fabrication of Superconducting Radio Frequency (SRF) cavities. These two metals are usually joined , using various welding techniques, using a third material in between. This contribution focuses on the development of an innovative electron beam welding technique capable of producing a strong bond between these two different materials. Several samples are produced and tested to assess the mechanical strength at room and cryogenic temperature as well as the composition of the resulting welded joint. Also, the first units of the Single Spoke Resonator type 2 (SSR2) cavities for the Proton Improvement Plan-II (PIP-II [1]) have been fabricated joining directly various grades of titanium to niobium and results gathered through the fabrication will be reported.

43 PARTICLE ACCELERATORS↗

Ferrite-Free Circulator for Precise Measurements of SRF Cavities with High Q-Factor

In this work, we suggest and investigate new magnetless circulators based on three resonators connected in a loop and parametrically modulated in time with mutual phase lag. The first design consists of three Fano resonators with a spectrally asymmetric response, in contrast to schemes based on the Lorentz resonators explored thus far. The second design includes three Fano-Lorentz resonators, i.e., it also possesses spatial asymmetry. We demonstrate that the asymmetric approach provides strong and reversible isolation for the practically feasible modulation amplitude and rate. The results of our work are promising for precise measurements of superconducting radio frequency cavities with high Q-factor.

43 PARTICLE ACCELERATORS↗

An OVERVIEW of MICROPHONICS in CEBAF and CURRENT MODERATION TECHNIQUES

Superconducting RF (SRF) structures are susceptible to frequency detuning from external vibrations and modal mechanical resonances in the structure. These small disturbances, known as microphonics, require additional RF power in CW accelerating structures since the frequency is constantly shifting. In the Jefferson Lab CEBAF accelerator, time and frequency data of this frequency shift have been recorded for many years, allowing a retrospective analysis of different microphonics-mitigation techniques. Some of these techniques are specific to the design of each CEBAF cryomodule, for example implementing BNNT damping material on the cavity string. Other techniques are universal such as affixing vacuum lines and reinforcing waveguide structures.

Powers, Tom↗

3D superconducting radio-frequency resonators for quantum computing

Superconducting radiofrequency (SRF) technology is being used not only in discovery science programs and basic research but also for several applications that benefit society more directly. The advantage of superconducting resonators over those made of normal-conducting metal is their ability to store electromagnetic energy with much lower dissipation. The high quality factor and longer dissipation time provided by these superconducting resonators can deliver superior performance. Currently, the quantum processing architecture uses resonators and interconnecting circuits operating in the microwave regime with superconducting strip-line technology and low noise electronic devices for switching and communication. The performance of these devices can be enhanced by embedding them in 3D SRF cavity resonators to prolong the coherence time, which improves the utility of the device by reducing error rates and allowing more manipulations (calculations) before the quantum state decays. In this presentation, I will review the current technology and progress towards the three dimensional SRF cavities to enhance the coherence time.

Dhakal, Pashupati↗

Superconducting Radio Frequency Resonators for Quantum Computing: A Short Review

Superconducting radiofrequency (SRF) technology is being used not only in discovery science programs and basic research but also for several applications that benefit society more directly. The advantage of superconducting resonators over those made of normal-conducting metal is their ability to store electromagnetic energy with much lower dissipation. The high-quality factor and longer dissipation time provided by these superconducting resonators can deliver superior performance. Currently, the quantum processing architecture uses resonators and interconnecting circuits operating in the microwave regime with superconducting strip-line technology and low noise electronic devices for switching and communication. The performance of these devices can be enhanced by embedding them in 3D SRF cavity resonators to prolong the coherence time, which improves the utility of the device by reducing error rates and allowing more manipulations (calculations) before the quantum state decays. Here, we present a short review of current microwave technology used in quantum computers and progress towards the 3D resonators to enhance thecoherence time.

Dhakal, Pashupati↗

Application of the ASME Boiler and Pressure Vessel Code in the Design of SRF Cavities at Fermilab

Jacketed Superconducting Radio Frequency (SRF) cavities structurally comprise of an inner niobium vessel surrounded by a liquid helium containment vessels. The pressure of the helium bath and/or its volume might be such that a jacketed SRF cavity shall be considered a system of pressure vessels. Thus, methods described in the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (BPVC) should be used to analyze the structural soundness of jacketed SRF cavities. This paper will report the use of the set of rules developed at Fermilab for the design of SRF cavities, such as jacketed 1.3 GHz cavities for LCLS-II HE and jacketed Single Spoke Resonator type~2 (SSR2) for PIP-II, to ensure a similar level of safety as prescribed by the ASME BPVC.

43 PARTICLE ACCELERATORS↗

IMPACT OF MEDIUM TEMPERATURE HEAT TREATMENT ON FLUX TRAPPING SENSITIVITY IN SRF CAVITIES

The effect of mid-T heat treatment on flux trapping sensitivity was measured on several 1.3 GHz single cell cavities subjected to medium temperature vacuum annealing at temperature of 150 - 400 ?C for a duration of 3 hours. The cavity was cooldown with residual magnetic field ?0 and ?20 mG in Dewar with cooldown condition of full flux trapped. The quality factor as a function of accelerating gradient was measured. The results show the correlation between the treatment temperature, quality factor, and sensitivity to flux trapping. Sensitivity increases with increasing heat treatment temperatures within the range of (200 - 325 ?C/3h).Moreover, variations in the effective penetration depth ofthe magnetic field and the density of quasi-particles can occur,influencing alterations in the cavity?s electromagneticresponse and resonance frequency.

Dhakal, P.↗

Investigating the Anomalous Frequency Variations Near $T_c$ of Nb SRF Cavities

We report recent studies on the anomalous frequency variations of 1.3 GHz Nb SRF cavities near the transition temperature Tc and use them to investigate the underlying physics of state-of-the-art surface treatments. One such feature, a dip in frequency, correlates directly with the quality factor at 16 MV/m and the anti-Q slope that arise in cavities with dilute concentrations of N interstitial in the RF layer achieved via N-doping and mid temperature baking. For N interstitial, we find that the dip magnitude and Tc follow exponential relationships with the electronic mean free path. We present the first observation of the frequency dip near Tc in a cavity baked at 200 C in-situ for 11 hours, which is concurrent with the anti-Q slope, and may be driven by oxygen diffused from the native oxide, thus suggesting the possibility of ‘‘O-doping.’’ We also investigate the conductivities of two cavities that display different resonant frequency behaviors near Tc and suggest that the anti-Q slope and frequency dip phenomena may occur in the presence of interstitial N or possibly O that inhibit the formation of proximity coupled Nb nano-hydrides.

43 PARTICLE ACCELERATORS↗

Signatures of enhanced superconducting properties in niobium cavities

Superconducting radio-frequency (SRF) niobium cavities are critical for modern particle accelerators, as well as for advancing superconducting quantum systems and enabling ultrasensitive searches for new physics. In this work, we report a systematic observation of an anomalous frequency dip in Nb cavities, which occurs at temperatures just below the critical temperature (𝑇𝑐 ), indicative of enhanced superconducting properties at 𝑇 ≪ 𝑇 𝑐 . The magnitude of this dip is strongly correlated with the rf surface resistance, impurity distribution near the surface, and 𝑇𝑐 . Additionally, we report measurements of the coherence peak in the ac conductivity of two Nb SRF cavities processed using distinct methods. By comparing recent theories developed to model this experimental data, we show that the frequency-dip feature, larger coherence peak height, and reduction in the temperature-dependent surface resistance with rf current occur at minimal but finite levels of disorder.

43 PARTICLE ACCELERATORS↗

Prevention of Dual-Mode Excitation in 9-Cell Cavities for LCLSII-HE

Dual-Mode Excitation, also referred to as mode-mixing, is a superposition of two fundamental pi modes in an SRF cavity. In 9-cell TESLA cavities used for the LCLSII-HE project, the two modes that are commonly excited are the pi mode (1300.2 MHz), and the 7/9 pi mode (1297.8 MHz). During vertical cavity qualification testing, only the pi mode is driven by the RF system. However, at high gradients, emitted power at the frequency of the 7/9 pi mode grows despite the RF system only powering the pi mode. When this happens, the RF power measurement system is unable to differentiate between the superimposed modes, and any data taken is invalid. The previous method of dealing with mode-mixing was to turn off power to the cavity, let both modes decay fully, then restore power. Because of the time-sensitive nature of this testing, this leads to underestimates of Q0 or any radiant field emission present in the cavity. The novel RF control solution prevents the 7/9 pi mode from being excited while not interfering with measurements of the fundamental pi mode. A second RF control system is connected to the cavity which drives the 7/9 pi mode. The loop phase for driving the 7/9 pi mode in self excited loop mode is determined then shifted by 180 degrees, thus providing a negative feedback to the undesired mode. Because this off-resonance power can be very small, on the order of milliwatts, it does not interfere with the high-power measurements of the fundamental pi mode. At Jefferson Lab, we are now able to test a cavity for the LCLSII-HE project with no problems from mode-mixing, which allows for CW processing of high-gradient multipacting and field emission.

Owen, Peter↗

Axion pulsarscope

Electromagnetic fields surrounding pulsars may source coherent ultralight axion signals at the known rotational frequencies of the neutron stars, which can be detected by laboratory experiments (e.g., pulsarscopes). As a promising case study, we model axion emission from the well-studied Crab pulsar, which would yield a prominent signal at 𝑓 ≈ 29.6 Hz regardless of whether the axion contributes to the dark matter abundance. We estimate the relevant sensitivity of future axion dark matter detection experiments such as DMRadio-GUT, Dark SRF, and CASPEr, assuming different magnetosphere models to bracket the uncertainty in astrophysical modeling. For example, depending on final experimental parameters, the Dark SRF experiment could probe axions with any mass 𝑚 𝑎 ≪ 10 −13 eV down to 𝑔 𝑎⁢𝛾⁢𝛾 ∼3 × 10 −13 GeV −1 with one year of data and assuming the vacuum magnetosphere model. These projected sensitivities may be degraded depending on the extent to which the magnetosphere is screened by charge-filled plasma. The promise of pulsar-sourced axions as a clean target for direct detection experiments motivates dedicated simulations of axion production in pulsar magnetospheres.

axions↗

Accelerator commissioning and rare isotope identification at the Facility for Rare Isotope Beams

In 2008, Michigan State University was selected to establish the Facility for Rare Isotope Beams (FRIB). Construction of the FRIB accelerator was completed in January 2022. Phased accelerator commissioning with heavy ion beams started in 2017 with the normal-conducting ion source and radio-frequency quadrupole. In April 2021, the full FRIB driver linear accelerator (linac) was commissioned, with heavy ion beams accelerated to energies above 200 MeV/nucleon by 324 superconducting radiofrequency (SRF) resonators operating at 2 K and 4 K with liquid-helium cooling. Further, in preparation for high-power operation, a liquid lithium charge stripper was commissioned with heavy ion beams up to uranium-238, followed by the simultaneous acceleration of multiple-charge-state heavy ion beams to energies above 200 MeV/nucleon. In December 2021, selenium-84 was produced with the FRIB target using a krypton-86 primary beam, demonstrating FRIB’s capability for scientific discovery.