Search NASASearch

SEARCH · Search NASA

Results for “resource assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

246 records · Page 3

Enhanced Recovery of Critical Minerals and Geological Hydrogen in The Mine of the Future

invited perspective article: The rapid demand for critical minerals (CMs) and hydrogen (H2) necessitates innovative solutions beyond conventional mining. This study explores enhanced mineral recovery (EMR) and geological hydrogen production (GeoH2) by leveraging the Earth’s subsurface as a reactive platform. Using ultramafic rocks and engineered fluids, the approach simultaneously mobilizes critical resources and produces H2 through natural processes like serpentinization. This paradigm offers a transformative pathway to secure essential materials and diversify energy resources, setting a foundation for the Terrestrial Mine of the Future

Yan, Keju

Scaling Demand Flexibility: Building on 30 Years of Energy Efficiency Success

With electricity consumption across the United States (US) and Canada anticipated to grow, energy efficiency program administrators have a key role to play in helping to ensure energy affordability and reliability in support of the broader economic systems utilities and grid support. Connected, demand side load balancing solutions, such as load shifting heating, ventilation and air conditioning (HVAC) systems and managed charging for electric vehicles (EVs), can dynamically manage energy, allowing for more volumetric electricity consumption without incurring the expense of upgraded transmission and distribution capabilities. When combined, or aggregated, many small loads can be managed to have meaningful impact on energy demand on the grid. Utilities and their partners have an opportunity to leverage decades of experience and the infrastructure needed to assess, design, implement, and measure programs to scale up the adoption of equipment with built-in load flexibility capabilities. Current efforts among a wide variety of electricity system service providers, utilities, standards agencies, regulators, national labs and private industry stakeholders aim to identify common standards, metrics, and methodologies for valuing grid services offered by demand side equipment. By combining those efforts with decades of proven energy efficiency resources, utilities are poised to effectuate a scaling up of equipment with energy management capabilities installed in homes and businesses across the US and Canada. This paper will provide an overview of how utilities are approaching this era of load growth and new peak demands across the United States and Canada. It will highlight the specific strategies that program administrators are employing to advance market transformation for grid-enabled products and devices that have the greatest potential to reduce energy use and increase load flexibility.

Grant, Peter

An Assessment of the Nevada Test Site for Low-Level Waste Management

This report presents a summary of description information, facilities, and operating practices at the Nevada Test Site. It is concluded that NTS is not only a feasible location for surface and near-surface storage of low-level wastes, but also a potential site for underground storage of higher level wastes.

052002* -- Nuclear Fuels-- Waste Disposal & Storag

Geospatial modeling of near subsurface temperatures of the contiguous United States for assessment of materials degradation

Abstract Understanding subsurface temperature variations is crucial for assessing material degradation in underground structures. This study maps subsurface temperatures across the contiguous United States for depths from 50 to 3500 m, comparing linear interpolation, gradient boosting (LightGBM), neural networks, and a novel hybrid approach combining linear interpolation with LightGBM. Results reveal heterogeneous temperature patterns both horizontally and vertically. The hybrid model performed best achieving a root mean square error of 2.61 °C at shallow depths (50–350 m). Model performance generally decreased with depth, highlighting challenges in deep temperature prediction. State-level analyses emphasized the importance of considering local geological factors. This study provides valuable insights for designing efficient underground facilities and infrastructure, underscoring the need for depth-specific and region-specific modeling approaches in subsurface temperature assessment.

Science & Technology - Other Topics

EXERGETIC: De-Risking Next-Generation Resilient Geothermal Hybrids via At-Scale Evaluation Using Virtual Emulation Digital Twin Environment for Efficient Operation

The DOE-GTO-funded project, award number 5.1.2.12, entitled "EXERGETIC - De-risking Next Generation Resilient Geothermal Hybrids via at-Scale Evaluation Using a Virtual Emulation Digital Twin Environment for Efficient Operation," advances the solution to these challenges by developing and validating a geothermal co-emulation environment implemented at the National Laboratory of the Rockies (NLR)'s Advanced Research on Integrated Energy Systems (ARIES) platform. This framework enables the de-risking of next-generation geothermal and geothermal hybrid systems through high-fidelity modeling, real-time digital emulation, advanced control strategies, and techno-economic assessment. The project focused on geothermal hybrid configurations that integrate geothermal power plants with concentrated solar power and underground thermal energy storage, enabling enhanced efficiency, flexibility, and grid support capabilities. The main goal of this project was the development of a geothermal digital co-emulation environment to demonstrate the technical and economic value of geothermal hybrid systems and their contribution to grid stability and flexibility. The EXERGETIC framework combined physics-based models, controls, and real assets at ARIES, including digital real-time simulators (DRTS), a 20-MW-scale controllable grid interface (CGI), and a 2-MW conventional generator. Detailed transient models were developed for the key subsystems of a hybrid geothermal plant, including parabolic trough solar collectors, reservoir thermal energy storage (RTES), and a binary Organic Rankine Cycle (ORC) power plant. The ORC model explicitly captured thermal inertia and off-design operation and integrated control strategies to dynamically respond to electric load profiles. The models were validated against published experimental and numerical studies, demonstrating strong agreement and confirming the accuracy and robustness of the modeling approach. The resulting digital twin represents geothermal-solar-storage systems at multiple scales (1 MW to 100 MW) and enables realistic emulation of grid-connected operation. The control architecture allows the geothermal resource to provide stable baseload generation, while solar and stored thermal energy supply flexible, dispatchable support during periods of high demand or variable grid conditions. A key contribution of the EXERGETIC project is the demonstration that geothermal hybrid systems can be designed to be active grid assets rather than passive baseload generators. Using the ARIES platform, the digital twin was evaluated under multiple grid scenarios, including load following, voltage support at the distribution level, and frequency response at the transmission level. Results show that hybrid geothermal systems can respond effectively to dynamic grid conditions, providing inertia-like behavior, primary frequency support, and voltage regulation through coordinated control. In addition to the performance and grid services capability analysis of geothermal and hybrid geothermal systems, the EXERGETIC project also focused on scalability and techno-economic analysis of geothermal hybrid plants. In particular, for the scalability analysis, machine-learning (ML)-based surrogate models were trained using data generated from the geothermal digital twin under different grid-connected scenarios and plant capacities. These ML models demonstrated strong interpolation and extrapolation capabilities across plant sizes, accurately reproducing both steady-state and transient responses with very low errors. Regarding the techno-economic analysis, plant performance results were integrated with cost models for hybrid geothermal systems, and the levelized cost of electricity (LCOE) was used as the main economic metric to evaluate system performance across a range of system capacities, solar shares, solar multiples, and storage durations. Results indicate that economies of scale significantly reduce geothermal LCOE as plant capacity increases, with large-scale systems (25-100 MW) achieving substantially lower costs than small plants. Hybridization with solar thermal energy and storage further improves economic performance by increasing capacity utilization and enabling flexible dispatch. In addition, thermal storage plays a critical role in reducing LCOE by maximizing geothermal, solar, and stored energy resources. In summary, the results from this project demonstrate that geothermal hybrid systems represent a promising alternative for increasing the energy conversion efficiency of geothermal technologies, contributing to the preservation of geothermal resources, and supporting the transition of geothermal plants from traditional baseload resources into flexible, resilient, and cost-competitive energy conversion technologies.

15 GEOTHERMAL ENERGY

Assessment of Molybdate Based Corrosion Inhibitor for use at the Savannah River Tank Farm Cooling Water System

The Savannah River Site (SRS) has relied on 51 underground storage tanks, many dating back to the 1950s, to store radioactive liquid waste generated from nuclear processing and radionuclide production. These tanks use carbon steel cooling coils, cooled by soft, acidic water, to dissipate the decayed heat produced by radioactive waste. For decades, following historical industry practices, chromate has been added to the cooling water (~450 ppm at pH 9-11) to effectively inhibit corrosion, ensuring cooling coil longevity. Inspections of failed coils reveal that chromate-treated surfaces are generally well-preserved.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Reliability Assessment of Solid-State Circuit Breakers (CRADA CRD-21-21469, Project 4 Final Report)

Growth in power requirements and the complexity of emerging distribution systems are creating the need for new solid-state products for many applications. The qualification requirements, testing standards and life-cycle management practices of solid-state devices used in protection applications is not established. The project will leverage newly developed accelerated testing capabilities design specifically for protection applications to generate large data sets that will enable advanced digital techniques for data analysis and embedded health monitoring.

14 SOLAR ENERGY

Envelope-driven comfort risk in residential demand response

Residential demand response (DR) is a valuable resource for grid reliability, but remains challenging because the highly heterogeneous residential building stock leads to widely varying and hard-to-predict load and comfort responses during DR events. Although prior research has estimated the technical potential of DR-capable technologies for achieving energy demand savings, little is known about how they affect thermal comfort. In particular, it remains unclear how indoor thermal conditions due to DR depend on the thermal envelope characteristics of the housing stock. To address this gap, this study provides a systematic, location-specific assessment of indoor thermal performance during DR-events across the US housing stock using both typical DR weather data and detailed building metadata. We evaluate how envelope characteristics influence indoor temperatures during realistic simulated summer and winter DR events across 37 US locations, applying both temperature threshold and rate of temperature change criteria to estimate region-level probabilities of discomfort. Additionally, we show the impact of distinct weather patterns that intensify or abate thermal stress on comfort outcomes. Results show a near-universal overheating risk in summer DR events, where comfort outcomes are strongly influenced by rapid risk of comfort violations. In contrast, overall winter DR discomfort risk is lower, risk escalation is more gradual and shows greater sensitivity to event duration. These findings offer a data-driven quantification of comfort risk across diverse climates and building envelopes, demonstrating the need for region-specific DR scheduling and discomfort mitigation strategies tailored to local weather patterns and the performance of existing residential buildings.

Demand response

Initial Feasibility Assessment and Broader Strategy Development for Fiber Integration via Advanced Manufacturing

Structural health monitoring is critical for ensuring the operational safety and cost-competitiveness of the developing advanced reactor designs. The extreme operational envelopes of these advanced architectures, having operating temperatures ranging 400°C–1,000°C and heightened displacement damage doses, render conventional commercially available piezoelectric transducers and resistive strain gauges unviable. Optical fiber sensors present an attractive solution for advanced radiation-hardened instrumentation due to their high thermal stability and distributed sensing capabilities. However, their deployment in embedded applications can be hindered by the severe thermomechanical strain driven by the coefficient of thermal expansion mismatch between fused silica glass and structural metal alloys like stainless steel (e.g., SS316L).

36 MATERIALS SCIENCE

PV Durability at Scale: Assessing Bifacial and TOPCon Field Performance

Recent field performance results of TOPCon and PERC Bifacial modules are presented based on small-scale deployments at NLR, and a selection of 3rd-party residential data. Bifacial PERC degradation rates are a median of -1 % / yr with bifacial TOPCon modules at a similar rate of -1.1 %/yr over the first couple of years. Comparable PERC Monofacial modules have a degradation rate of -0.5%/yr. Some TOPCon modules exhibited an indoor dark metastability effect which requires recovery by light soaking or UV exposure prior to IV curve measurement. Further monitoring is needed to confirm the long-term stability of TOPCon modules.

14 SOLAR ENERGY

Comparative Assessment of Battery Carbon Footprint Calculation Frameworks to Support U.S. Battery Manufacturing

A “battery passport” is a digital record that provides comprehensive information about an individual battery across its life cycle. This concept has been introduced by Battery Regulation (EU) 2023/1542 [1], which applies to batteries for electric vehicles (EVs), industrial batteries with a capacities greater than 2 kWh, and batteries for light means of transport (LMT) greater than 2kWh sold in the European Union (EU) market – impacting manufacturers and exporters across multiple jurisdictions globally. Among its reporting mandates, a key feature of battery passports is the requirement for a carbon footprint (CF) calculation methodology supported by enhanced data granularity to enable traceable and verifiable CF results. While no other jurisdictions have yet adopted formal battery passport requirements like the EU’s, some are developing CF calculation methods to comply with the EU Battery Regulation or are creating CF-related regulations that could evolve in a similar direction, reflecting the growing importance of battery CF guidelines for manufacturers seeking to remain competitive in global markets.

Zhang, Jingyi [Argonne National Laboratory (ANL),

Preliminary Assessment for the Electric Load Shifting Potential of Integrating Thermal Energy Storage with Heat Pumps in Residential Buildings in Texas of United States

The widespread adoption of electric-driven heat pumps for heating and cooling is expected to significantly increase electric demand. Cooling electric demand will result in an increase in peak hours electric loads, placing additional strain on the grid during peak hours. This challenge, combined with the current rapidly increasing demand from data centers, exacerbates the electric demand duck curve problem. Integrating thermal energy storage (TES) with heat pump can shift electric use for heating and cooling from peak to off-peak hours of the electric grid, which can help flatten the daily electric demand profile of a building. This paper presents a novel design that integrates heat pump with TES (HP-TES), which uses phase change materials (PCM). Heat pump charges TES by melting or freezing PCM during off-peak hours when there is no thermal demand from the building. TES is then discharged (i.e., by freezing or melting PCM) during peak hours to provide a more favorable heat source or heat sink for the heat pump to meet the thermal demand of the building with lower electricity use than conventional air-source heat pumps. Computer simulations were developed to predict the performance of HP-TES applied to a typical single-family house in the US. The building-level simulation results were scaled up to preliminarily assess the aggregated impacts of deploying HP-TES across all single-family houses in Texas of the United States, including reduction of peak demand of the electric grid.

Anees, Fady [ORNL]

Development of Post-Consumer Textile Waste Degradation Protocol and Related Downstream Transformations: Cooperative Research and Development (Final Report)

Tereform, Inc. (Tereform) is developing molecular deconstruction processes to transform waste materials into chemical building blocks. During the CRADA, Tereform deconstructed real-world post-consumer substrates into chemical monomers, validated their performance on laboratory scales, demonstrated feasibility of the degradation products in downstream transformations, and successfully scaled the reaction to kilogram-scale. These results were used to develop and refine technoeconomic analysis and lifecycle assessments to evaluate the economic feasibility and environmental impacts of the process.

36 MATERIALS SCIENCE

Rapid Assessment of Sulfate Resistance in Mortar and Concrete

Extensive research has been conducted on the sulfate attack of concrete structures; however, the need to adopt the use of more sustainable materials is driving a need for a quicker test method to assess sulfate resistance. This work presents accelerated methods that can reduce the time required for assessing the sulfate resistance of mixtures by 70%. Class F fly ash has historically been used in concrete mixtures to improve sulfate resistance. However, environmental considerations and the evolving energy industry have decreased its availability, requiring the identification of economically viable and environmentally friendly alternatives to fly ash. Another challenge in addressing sulfate attack durability issues in concrete is that the standard sulfate attack test (ASTM C1012) is time-consuming and designed for only standard mortars (not concrete mixtures). To expedite the testing process, accelerated testing methods for both mortar and concrete mixtures were adopted from previous work to further the development of the accelerated tests and to assess the feasibility of testing the sulfate resistance of mortar and concrete mixtures rapidly. This study also established criteria for interpreting sulfate resistance for each of the test methods used in this work. A total of 14 mortar mixtures and four concrete mixtures using two types of Portland cement (Type I and Type I/II) and various supplementary cementitious materials (SCMs) were evaluated in this study. The accelerated testing methods significantly reduced the evaluation time from 12 months to 21 days for mortar mixtures and from 6 months to 56 days for concrete mixtures. The proposed interpretation method for mortar accelerated test results showed acceptable consistency with the ACI 318-19 interpretations for ASTM C1012 results. The interpretation methods proposed for the two concrete sulfate attack tests demonstrated excellent consistency with the ASTM C1012 results from mortar mixtures with the same cementitious materials combinations. Metakaolin was shown to improve sulfate resistance for both mortar and concrete mixtures, while silica fume and natural pozzolan had a limited impact. Using 15% metakaolin in mortar or concrete mixtures with Type I/II cement provided the best sulfate resistance.

Chemistry