Theoretical study of the effect of ionospheric return currents on the electron temperature

A time-dependent, three-dimensional model of the high-altitude ionosphere is presently used to study the effects of field-aligned ionospheric return currents on auroral electron temperatures for different seasonal and solar cycle conditions, as well as for different upper boundary heat fluxes. The average, large scale, return current densities, which are a few microamps/sq m, are too small to affect auroral electron temperatures. The thermoelectric effect exhibits a pronounced solar cycle and seasonal dependence, and its heat transport corresponds to an upward flow of electron energy which can be either a source or sink of electron energy depending on altitude and geophysical conditions.

Schunk, R. W.↗

THE INTEGRATION OF PROCESS HEAT APPLICATIONS TO HIGH TEMPERATURE GAS REACTORS

A high temperature gas reactor, HTGR, can produce industrial process steam, high-temperature heat-transfer gases, and/or electricity. In conventional industrial processes, these products are generated by the combustion of fossil fuels such as coal and natural gas, resulting in significant emissions of greenhouse gases such as carbon dioxide. Heat or electricity produced in an HTGR could be used to supply process heat or electricity to conventional processes without generating any greenhouse gases. Process heat from a reactor needs to be transported by a gas to the industrial process. Two such gases were considered in this study: helium and steam. For this analysis, it was assumed that steam was delivered at 17 MPa and 540 C and helium was delivered at 7 MPa and at a variety of temperatures. The temperature of the gas returning from the industrial process and going to the HTGR must be within certain temperature ranges to maintain the correct reactor inlet temperature for a particular reactor outlet temperature. The returning gas may be below the reactor inlet temperature, ROT, but not above. The optimal return temperature produces the maximum process heat gas flow rate. For steam, the delivered pressure sets an optimal reactor outlet temperature based on the condensation temperature of the steam. ROTs greater than 769.7 C produce no additional advantage for the production of steam.

01 COAL, LIGNITE, AND PEAT↗

Power Hibernation for Low-Cost Solar Powered Lunar Missions

Because the surface of the Moon drops to cryogenic temperatures, no solar-powered lunar spacecraft have reliably operated beyond a single lunar day. Passive thermal control cannot keep a spacecraft sufficiently warm for the 354-hour lunar night, and active thermal control requires a dramatic increase in battery mass at the expense of payload mass. Extreme conditions seen on the lunar surface suggest a radioisotope solution is ideal, but mass, cost, and schedule are inconsistent with low-cost frequent flight intent of the commercial lunar payload services (CLPS) program. To solve the issue of lunar night survivability without radioisotope sources of power and heat, a lunar power hibernation approach is being developed at the Glenn Research Center, which exploits the ability of common 18650 Lithium-ion cells to passively survive cryogenic freeze-thaw cycles and recover without apparent performance degradation. A key aspect of this hibernation approach is the use of cryogenically operable electronics that safely manage the restoration of the battery thermal environment at lunar dawn. A spacecraft utilizing this strategy will operate into the lunar night on batteries until the state of charge or spacecraft temperature reaches a predetermined threshold. At this point, systems are shut down and the battery is isolated from the main bus to prevent charge or discharge during the freezing and thawing transitions. The system remains passive until lunar dawn, where temperatures can reach as low as 50 K. All electronics must be tolerant to these conditions. When the solar arrays are finally illuminated at lunar dawn, the main bus power electronics will initiate a “cold start” and begin regulating array power. The main bus electronics must be designed to operate at cryogenic temperatures. Array power is used to warm the battery and passive electronics back to operational temperatures. Once batteries are returned to normal temperatures, diagnostics and precharging is performed, as needed, and the battery is reconnected. The overall spacecraft system reboots and returns to nominal operations until lunar night returns. To assure that we can develop batteries suited for many hibernation freeze/thaw cycles, STMD Space Technology Research Grant Program (STRG) has selected two principal investigators that will thoroughly characterize of the Li-ion cell through the freeze-thaw process, investigate degradation mechanisms, and identify potential diagnostic techniques. STMD STRG is also funding an investigation of Gallium-Nitride semiconductors for cryogenic power applications. This work includes physics-informed modeling that considers cryogenic conductivity, carrier mobility, and quantum effects that govern semiconductor performance at cryogenic temperatures. These models can enable engineers to develop accurate cryogenic simulation models that assist in the design of power controls stable over the entire lunar surface temperature range. Meanwhile, Glenn is performing cryogenic testing of batteries and electronics, establishing design guidelines for power applications in extreme cold lunar environment, and potentially developing a hibernation technology demonstrator. The hibernation approach will enable low-cost lunar robotic missions to extend their operating lifetime to many months while minimizing development costs and impact on payload capacity. The need for cryogenically operable electronics is restricted to only main bus power and battery controls, as the majority of systems simply need to passively tolerate cryogenic temperatures. This allows developers to continue to exploit the cost savings of legacy and COTS hardware with minimum modification. For these reasons, lunar power hibernation is a viable near-term solution for lunar night survivability for solar powered commercial landers.

Space power↗

Temporal trends and transport within and around the Antarctic polar vortex during the formation of the 1987 Antarctic ozone hole

During AAOE in 1987 an ER-2 high altitude aircraft made twelve flights out of Punta Arenas, Chile (53 S, 71 W) into the Antarctic polar vortex. The aircraft was fitted with fast response instruments for in situ measurements of many trace species including O3, ClO, BrO, NO sub y, NO, H2O, and N2O. Grab samples of long-lived tracers were also taken and a scanning microwave radiometer measured temperatures above and below the aircraft. Temperature, pressure, and wind measurements were also made on the flight tracks. Most of these flights were flown to 72 S, at a constant potential temperature, followed by a dip to a lower altitude and again assuming a sometimes different potential temperature for the return leg. The potential temperature chosen was 425 K (17 to 18 km) on 12 of the flight legs, and 5 of the flight legs were flown at 450 K (18 to 19 km). The remaining 7 legs of the 12 flights were not flown on constant potential temperature surfaces. Tracer data have been analyzed for temporal trends. Data from the ascents out of Punta Arenas, the constant potential temperature flight legs, and the dips within the vortex are used to compare tracer values inside and outside the vortex, both with respect to constant potential temperature and constant N2O. The time trend during the one-month period of August 23 through September 22, 1987, shows that ozone decreased by 50 percent or more at altitudes form 15 to 19 km. This trend is evident whether analyzed with respect to constant potential temperature or constant N2O. The trend analysis for ozone outside the vortex shows no downward trend during this period. The analysis for N2O at a constant potential temperature indicates no significant trend either inside or outside the vortex; however, a decrease in N2O with an increase in latitude is evident.

Proffitt, M. H.↗

The Effect of Temperature on the Preservation of Volatile-Rich Lunar Samples

Introduction. The Moon’s south pole is a high-priority target for human exploration and scientific study. This interest is, in part, due to the presence of Permanently Shadowed Regions (PSRs), which could contain high concentrations of unique volatiles at cryogenic temperatures [1]. Returned samples from PSRs may include a unique combination of rocks, regolith, and volatile species, providing unprecedented insights into the history of the Solar System and the potential for resource utilization on the Moon. However, because PSR samples are cryogenic up-on collection, lunar polar sample return will eventually require cold stowage for the journey from the Moon to Earth. Without cold stowage, PSR sample return will likely result in phase changes and chemical reactions within the volatile component of the sample, which would negatively impact the resulting scientific studies of those samples. This abstract summarizes the initial results from an ongoing characterization of analog PSR samples at a range of temperatures, with the goal of defining the temperatures needed for a flight cold stowage freezer. Background. Based on remote sensing observations of the Moon [2], south polar PSRs range in temperature from ~120K for small and/or shallow PSRs to ~20K at the most extreme locations in large, deep PSRs. A range of volatiles have been hypothesized to exist at the surface or subsurface of the lunar poles [3-5 and others]. This hypothesis was verified when the LCROSS mission impacted the <50-K PSR in the crater Cabeus, detecting a range of volatiles from water to low condensation temperature species such as H2S and methane [6]. Species such as H2S and ammonia (also detected by LCROSS) are also highly reactive, and increase the likelihood of chemical reactions at elevated (non-cryogenic) temperatures. At the Johnson Space Center’s Planetary Exploration and Astromaterials Research Laboratory (JSC-PEARL), we have developed a volatile-bearing lunar simulant that incorporates several of the species detected by LCROSS [Table 1] mixed cryogenically with the USGS Lunar Highlands Type (LHT) regolith simulant. The new volatile-regolith simulant will be used to assess the degree of sample alteration at room temperature, -20°C, -80°C, and -196°C (liquid nitro-gen), over a two-week period. Room temperature samples represent those likely to be returned during initial missions without cold stowage, -20°C provides an analog to Apollo cold curated samples, -80°C is the temperature of multiple flight payload freezers (e.g., MELFI), and -196°C is analogous to lunar PSRs. Two weeks is an approximation of the time between sample collection and Earth return for initial Artemis missions. Over this period of time, sample head-space gases will be analyzed using a Universal Gas Analyzer (UGA, a type of mass spectrometer) coupled with a Baratron pressure sensor. After testing, the regolith component of the simulant will be purged of volatiles and preserved for future electron beam and/or FTIR analysis. Experimental Procedure. Volatile-regolith simulants will be produced as an initial homogenous batch; this batch will then be distributed into aliquots (gas chromatography/GC vials or cryo vials), ensuring that each sample has the same starting composition and conditions [Fig. 1]. In addition to the “full” simulant shown in Table 1, less complex simulant compositions will be used as baseline and control samples [Table 2]. Aliquots will be produced in triplicate for each simulant composition, storage temperature, and date of sampling. Headspace gases in all Day 0 samples will be analyzed by the UGA immediately. Cold storage samples for future analytical days will be placed in freezers appropriate to their target temperatures (-20°C, -80°C, -196°C). For ambient-temperature samples, regolith and regolith-water samples will be stored in a fume hood, while the full simulant will be stored in a sealed Parr vessel for safety; no other simulants (RWCM/ RWCM+) will be stored at ambient temperature for this test. Samples will be analyzed by UGA in this manner on each Analysis Day outlined in Table 2. Analytical Data. The UGA measures the partial pressures in a single sample aliquot over a set mass range of 0-105 atomic mass units (AMU) [Figure 2]; this set range was selected to slightly exceed the mass of the highest-mass expected reaction product (H2SO4). The Baratron complements the UGA by measuring the total pressure in the headspace of a sample vial. Coupled together, the quantitative abundances of gases will be monitored throughout the test. UGA analyses of the triplicate samples for each storage temperature, day, and simulant composition will be averaged, and standard deviations for each will be calculated. The compositions of starting species (shown in Table 1) will be characterized as a function of time, and the presence of any new compounds (reaction products) will be monitored as well. Total pressures will be recorded for each sample analysis, and any samples that show signs of leakage (e.g., a significant reduction in pressure or simulant volatiles) will be discarded. Anticipated Results. Testing is planned to begin in January 2022. The resulting data will allow compositional and phase changes in the volatile component of the simulants to be determined. Both the reduction in initial compounds and the addition of reaction products are expected to be observed. In addition, the relative efficacy of the different temperatures at pre-serving the initial composition of the simulants will be quantified. Finally, the regolith component of each sample will be argon-purged and stored in a controlled environment for future laboratory analysis. Compositional and morphological changes in the regolith are expected for samples above 0°C. This test will be repeated three times over the course of 2022. Understanding the effect of temperature on both the volatile and regolith components of analog lunar materials will allow requirements for a cold stowage freezer to be developed. The implementation of cold stowage for lunar polar missions will maximize the preservation of returned samples, enabling ground-breaking lunar and Solar System volatiles science for decades to come.

J L Mitchell↗

Heat flux instrumentation for HYFLITE thermal protection system

Tasks performed in this project were defined in a September 9, 1994 meeting of representatives of Vatell, NASA Lewis and Virginia Tech. The overall objective agreed upon in the meeting was 'to demonstrate the viability of thin film techniques for heat flux and temperature sensing in HYSTEP thermal protection systems'. We decided to attempt a combination of NASA's and Vatell's best heat flux sensor technology in a sensor which would be tested in the Vortek facility at Lewis early in 1995. The NASA concept for thermocouple measurement of surface temperature was adopted, and Vatell methods for fabrication of sensors on small diameter substrates of aluminum nitride were used to produce a sensor. This sensor was then encapsulated in a NARloy-Z housing. Various improvements to the Vatell substrate design were explored without success. The basic NASA and Vatell sensor layouts were analyzed by finite element modeling, in an attempt to better understand the effects of material properties, dimensions and thermal differential element location on sensor symmetry, bandwidth and sensitivity. This analysis showed that, as long as the thermal resistivity of the thermal differential element material is much larger (10X) than that of the substrate material, the simplest arrangement of layer is best. During calibration of the sensor produced in this project, undesirable side-effects of combining the heat flux and temperature sensor return leads were observed. The sensor did not cleanly separate the heat flux and temperature signals, as sensors with four leads have consistently done before. Task 7 and 8 discussed in the meeting will be performed with a continuation of funding in 1995. The following is a discussion of each of the tasks performed as outlined in the statement of work dated september 26, 1994. Task 1A was added to cover further investigation into the NASA sensor concept.

Diller, T. E.↗

Magnetism of Ho 1-x Tb x Al₂ alloys: Critical dependence of a first-order transition on Tb concentration

HoAl₂ exhibits a first-order spin reorientation transition at 20 K, which is manifested as a sharp peak in the heat capacity. When Ho is partially replaced by only 5% of Tb, the sharp heat-capacity peak in Ho 1-x Tb x Al₂ (x = 0.05) disappears, and then reappears again for x ≥ 0.07. For x = 0.05, the anomaly corresponding to the spin reorientation transition is barely seen in the heat capacity, but as x exceeds 0.07 the weak anomaly transforms to a sharp peak. The spin reorientation transition temperature increases to 29 K for x = 0.05, and as x increases further the transition shifts to lower temperature and returns to ~20 K for x = 0.25. The transition is no longer observed when x exceeds 0.60. Temperature-dependent x-ray powder-diffraction data confirm the first-order nature of the spin reorientation transition for the alloy with x = 0.40, and indicate that the compound retains the room-temperature cubic structure within the sensitivity of the technique. Experimental observations are discussed considering the easy magnetization directions of HoAl₂ and TbAl₂.

Khan, Mahmud↗

The effect of electron temperature and impact ionization on Martian return AOTV flowfields

Various electron impact ionization models in conjunction with a quasi-equilibrium electron temperature model have been investigated and applied to the stagnation region of a hypothetical 2.3 m nose radius Martian return AOTV. For the conditions considered, U = 12 km/sec at 80 km, both multi-temperature inviscid and viscous results indicate that a two-step ionization impact model predicts ionization distances in agreement with experimental data, that nonequilibrium chemistry and radiation effects are important throughout the stagnation zone, and that the quasi-equilibrium electron temperature model is reasonable. Also, using a non-grey emission-absorption radiation step model, it is shown that nonequilibrium causes a reduction in radiative heating from that predicted for equilibrium conditions and that compared to an adiabatic wall a cool wall (1650 deg K) results in a 28 to 45 percent reduction in radiative heating due to absorption near the wall.

Carlson, Leland A.↗

Field Performance of Inverter-Driven Heat Pumps in Cold Climates

CARB observed a wide range of operating efficiencies and outputs from site to site. Maximum capacities were found to be generally in line with manufacturer's claims as outdoor temperatures fell to -10°F. The reasons for the wide range in heating performance likely include: low indoor air flow rates, poor placement of outdoor units, relatively high return air temperatures, thermostat set back, integration with existing heating systems, and occupants limiting indoor fan speed. Even with lower efficiencies than published in other studies, most of the heat pumps here still provide heat at lower cost than oil, propane, or certainly electric resistance systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Further information on structure of the atmosphere of Venus derived from the Vega Venus balloon and lander mission

Continued analysis of the pressure and temperature data returned by the two Vega mission balloons has revealed an apparently significant difference in mean atmospheric static stability between the two data sets. Furthermore, the stability is time dependent within each data set. The 6.5 K temperature contrast between the two balloons remains, and appears to have a counterpart in the contrast between two of the Pioneer Venus probes at these levels, which has been attributed to planetary scale waves. Comparisons of the Vega 2 lander data with those of the Pioneer Venus Large Probe shows relatively close agreement in the state properties and in the atmospheric static stability profiles as well.

Seiff, A.↗

Field Test of Boiler Primary Loop Temperature Controller

Beyond these initial system efficiency upgrades are an emerging class of Advanced Load Monitoring (ALM) aftermarket controllers that dynamically respond to the boiler load, with claims of 10% to 30% of fuel savings over a heating season. For hydronic boilers specifically, these devices perform load monitoring, with continuous measurement of supply and in some cases return water temperatures. Energy savings from these ALM controllers are derived from dynamic management of the boiler differential, where a microprocessor with memory of past boiler cycles prevents the boiler from firing for a period of time, to limit cycling losses and inefficient operation during perceived low load conditions. These differ from OTR controllers, which vary boiler setpoint temperatures with ambient conditions while maintaining a fixed differential. PARR installed and monitored the performance of one type of ALM controller, the M2G from Greffen Systems, at multifamily sites in the city of Chicago and its suburb Cary, IL, both with existing OTR control. Results show that energy savings depend on the degree to which boilers are over-sized for their load, represented by cycling rates. Also savings vary over the heating season with cycling rates, with greater savings observed in shoulder months. Over the monitoring period, over-sized boilers at one site showed reductions in cycling and energy consumption in line with prior laboratory studies, while less over-sized boilers at another site showed muted savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Test of Boiler Primary Loop Temperature Controller

Beyond these initial system efficiency upgrades are an emerging class of Advanced Load Monitoring (ALM) aftermarket controllers that dynamically respond to the boiler load, with claims of 10% to 30% of fuel savings over a heating season. For hydronic boilers specifically, these devices perform load monitoring, with continuous measurement of supply and, in some cases, return water temperatures. Energy savings from these ALM controllers are derived from dynamic management of the boiler differential, where a microprocessor with memory of past boiler cycles prevents the boiler from firing for a period of time, to limit cycling losses and inefficient operation during perceived low load conditions. These differ from OTR controllers, which vary boiler setpoint temperatures with ambient conditions while maintaining a fixed differential.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Extraordinary March 2022 East Antarctica “Heat” Wave. Part I: Observations and Meteorological Drivers

Abstract Between 15 and 19 March 2022, East Antarctica experienced an exceptional heat wave with widespread 30°–40°C temperature anomalies across the ice sheet. This record-shattering event saw numerous monthly temperature records being broken including a new all-time temperature record of −9.4°C on 18 March at Concordia Station despite March typically being a transition month to the Antarctic coreless winter. The driver for these temperature extremes was an intense atmospheric river advecting subtropical/midlatitude heat and moisture deep into the Antarctic interior. The scope of the temperature records spurred a large, diverse collaborative effort to study the heat wave’s meteorological drivers, impacts, and historical climate context. Here we focus on describing those temperature records along with the intricate meteorological drivers that led to the most intense atmospheric river observed over East Antarctica. These efforts describe the Rossby wave activity forced from intense tropical convection over the Indian Ocean. This led to an atmospheric river and warm conveyor belt intensification near the coastline, which reinforced atmospheric blocking deep into East Antarctica. The resulting moisture flux and upper-level warm-air advection eroded the typical surface temperature inversions over the ice sheet. At the peak of the heat wave, an area of 3.3 million km 2 in East Antarctica exceeded previous March monthly temperature records. Despite a temperature anomaly return time of about 100 years, a closer recurrence of such an event is possible under future climate projections. In Part II we describe the various impacts this extreme event had on the East Antarctic cryosphere. Significance Statement In March 2022, a heat wave and atmospheric river caused some of the highest temperature anomalies ever observed globally and captured the attention of the Antarctic science community. Using our diverse collective expertise, we explored the causes of the event and have placed it within a historical climate context. One key takeaway is that Antarctic climate extremes are highly sensitive to perturbations in the midlatitudes and subtropics. This heat wave redefined our expectations of the Antarctic climate. Despite the rare chance of occurrence based on past climate, a future temperature extreme event of similar magnitude is possible, especially given anthropogenic climate change.

Wille, Jonathan D.↗

Direct Liquid Cooling for Electronic Equipment

This report documents a demonstration of an electronic-equipment cooling system in the engineering prototype development stage that can be applied in data centers. The technology provides cooling by bringing a water-based cooling fluid into direct contact with high-heat-generating electronic components. This direct cooling system improves overall data center energy efficiency in three ways: 1) High-heat-generating electronic components are more efficiently cooled directly using water, capturing a large portion of the total electronic equipment heat generated. This captured heat reduces the load on the less-efficient air-based data center room cooling systems. The combination contributes to the overall savings. 2) The power consumption of the electronic equipment internal fans is significantly reduced when equipped with this cooling system. 3) The temperature of the cooling water supplied to the direct cooling system can be much higher than that commonly provided by facility chilled water loops, and therefore can be produced with lower cooling infrastructure energy consumption and possibly compressor-free cooling. Providing opportunities for heat reuse is an additional benefit of this technology. The cooling system can be controlled to produce high return water temperatures while providing adequate component cooling. The demonstration was conducted in a data center located at Lawrence Berkeley National Laboratory in Berkeley, California. Thirty-eight servers equipped with the liquid cooling system and instrumented for energy measurements were placed in a single rack. Two unmodified servers of the same configuration, located in an adjacent rack, were used to provide a baseline. The demonstration characterized the fraction of heat removed by the direct cooling technology, quantified the energy savings for a number of cooling infrastructure scenarios, and provided information that could be used to investigate heat reuse opportunities. Thermal measurement data were used with data center energy use modeling software to estimate overall site energy use. These estimates show that an overall data center energy savings of approximately 20 percent can be expected if a center is retrofitted as specified in the models used. Increasing the portion of heat captured by this technology is an area suggested for further development.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of an Additively Manufactured Subscale Secondary Sealed Container for the NASA FROSTE Project

This presentation details the development of an additively manufactured (AM) subscale test article for the secondary sealed container (SSC) as part of the NASA FROSTE project. FROSTE is focused on the collection of regolith samples from shadowed regions of the Moon and the preservation of those samples at cryogenic temperatures for return to Earth. Our team was integrated into the FROSTE program to leverage innovative design approaches and additive manufacturing capabilities in support of a scalable development strategy, where the subscale configuration serves as the development path toward a full-scale SSC. Scalmalloy was selected as the primary material for all AM components due to its favorable strength-to-weight ratio, thermal conductivity, and demonstrated performance in aerospace applications. Its aluminum-based composition supports robust mechanical behavior at cryogenic temperatures while enabling efficient heat transfer and control of thermal gradients within the containment system. The SSC architecture consists of an outer container assembly that houses a phase change material (PCM) tank, which in turn contains primary containers holding the regolith. Thermal management relies on controlled conductive and radiative heat transfer, including a thermal connection assembly that interfaces the PCM tank to an external cryocooler via a thermal strap, and IMLI surrounding the PCM tank to inhibit radiative heat transfer. The outer container assembly incorporates sealing interfaces, thermal connection ports, and I/O feedthroughs, with PTFE spring seals used at critical interfaces to maintain containment integrity. The PCM tank is manufactured as a single monolithic Scalmalloy component and incorporates an integral lattice structure to minimize thermal gradients, internal channels for thermocouple routing, and interface features for thermal connection assembly integration. The tank is centrally suspended within the outer container using support rings, with G10 insulating components employed to inhibit thermal leaks. This work describes the design methodology, AM approach, and key considerations used to inform the design.

regolith↗

Water Phase Change Heat Exchanger System Level Analysis for Low Lunar Orbit

In low Lunar orbit (LLO) the thermal environment is cyclic - extremely cold in the eclipse and as warm as room temperature near the subsolar point. Phase change material heat exchangers (PCHXs) are the best option for long term missions in these environments. The Orion spacecraft will use a n-pentadecane wax PCHX for its envisioned mission to LLO. Using water as a PCM material is attractive because its higher heat of fusion and greater density result in a lighter, more compact PCHX. To assess the use of a water PCHX for a human spacecraft in a circular LLO, a system level analysis was performed for the Orion spacecraft. Three cases were evaluated: 1) A one-to-one replacement of the wax PCHX on the internal thermal control loop with a water PCHX (including the appropriate control modifications), 2) reducing the radiator return setpoint temperature below Orion's value to enhance PCHX freezing, and 3) placing the water PCM on the external loop. The model showed that the water PCHX could not be used as a drop-in replacement for the wax PCHX. It did not freeze fully during the eclipse owing to its low freezing point. To obtain equivalent performance, 40% more radiator area than the Orion baseline was required. The study shows that, although water PCHXs are attractive at a component level, system level effects mean that they are not the best choice for LLO.