Search NASA⌕ Search

SEARCH · Search NASA

Results for “robot arm”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Using Robotic Manipulators for Radioactive Waste Inspection - 20090

The global nuclear industry has a growing volume of nuclear waste which needs to be scanned, sorted according to its activity and material type, then processed into the correct waste packages for long term storage and disposal. It is vital that there is a detailed understanding of the waste inventory stored in long term waste containers, as knowledge of their contents could predict or prevent any adverse effects in storage. The numerous 'scan and sort' tables which are currently used at many different facilities around the world to sort waste into their correct containers are human operated and require very slow gamma scanning procedures combined with educated guesswork to manually sort the waste. This often leads to excessive conservatisms, with placement of lower activity wastes in higher activity containers, which in turn costs significantly more to store. In the United Kingdom it costs UK Pounds 46 k per cubic meter to store intermediate level waste compared to just UK Pound 2.9 k per cubic meter to store low level waste according to a 2008 Department of Energy and Climate Change report in the UK. A proposed solution to this problem, is the use of a robotic manipulator to automatically inspect the 'scan and sort table' in order to produce an accurate 3D model of the table's waste contents and attach an overlaid radiation map. The radiation map contains spectrometry data and can in consequence be used to distinguish and locate specific radioisotopes. The 3D model should be as accurate as possible in order to allow for a second robot arm with an attached gripper to grasp the objects and place them into their designated long-term storage container. Various scanning procedures are explored in this study including basic raster scanning, adaptive raster scanning and point sampling. The optimal solution will in practice be defined by the required application and activity level of the wastes being inspected. The results presented in this study indicate that it is possible to produce a centimeter accurate 3D model of a mixed assortment of components on a nuclear waste 'scan and sort' table. In addition, it was shown that the waste objects emitting radiation could be accurately identified and located, with an overlaid radiation map. This study is applicable across the nuclear waste management sector. Many of the ideas and concepts developed in this study are applicable in other decommissioning settings for example, dismantling of legacy gloveboxes or routine inspection of nuclear waste packages in storage. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Automated Strain Construction for Biosynthetic Pathway Screening in Yeast

Automation accelerates the Design-Build-Test-Learn (DBTL) cycle for synthetic biology; however, most strain construction pipelines lack robotic integration. Here, in this study, we present the workflow design and source code for a modular, integrated protocol that automates the Build step in Saccharomyces cerevisiae. We programmed the Hamilton Microlab VANTAGE to integrate off-deck hardware via its central robotic arm, enabling automated steps that increased throughput to 2,000 transformations per week. We developed a user interface with the Hamilton VENUS software to support on-demand parameter customization. As a proof of concept, we screened a gene library in an engineered yeast strain producing verazine, a key intermediate in the biosynthesis of steroidal alkaloids. Our pipeline rapidly identified pathway bottlenecks and genes that enhanced verazine production by 2.0- to 5-fold. This technical note provides resources for synthetic biologists designing yeast workflows for biofoundries to screen libraries for pathway discovery/optimization, combinatorial biosynthesis, and protein engineering.

automation↗

Automation for Electric Vehicle Battery Pack Disassembly

Battery‐electric vehicles (EVs) are growing exponentially. The demand for these batteries is expected to increase sevenfold by 2035. The EV batteries reach their end of life when the capacity fades to 70%–80% of new, with some being removed from the primary applications with even lower levels of degradation. These batteries can be used in less demanding applications. The disassembly process is currently manual, slow, unsafe, and expensive. Automation is needed to increase the throughput. EV battery packs feature various continually changing designs and form factors, which limit the usefulness of deterministically programmed robotic solutions. The conceptual robotic disassembly of EV batteries has attracted the attention of researchers. However, while many approaches have been proposed, practical implementations are lacking. Here, we review proposed concepts for EV battery disassembly and describe the selected approach, with elements of partial solutions validated in a laboratory setting, including the selection of commercial solutions, the development of custom end effectors, and methodologies for detection, localization, and classification of fasteners. The computer vision tasks employed an overhead 2D camera to detect the type of battery pack and approximate localization of fasteners, and a 3D camera mounted on the robotic arm for precise localization (position and tilt) and classification.

Islam, Abu [Rochester Inst. of Technology, Rochest↗

The SuperCam Instrument Suite on the NASA Mars 2020 Rover: Body Unit and Combined System Tests

The SuperCam instrument suite provides the Mars 2020 rover, Perseverance, with a number of versatile remote-sensing techniques that can be used at long distance as well as within the robotic-arm workspace. These include laser-induced breakdown spectroscopy (LIBS), remote time-resolved Raman and luminescence spectroscopies, and visible and infrared (VISIR; separately referred to as VIS and IR) reflectance spectroscopy. A remote micro-imager (RMI) provides high-resolution color context imaging, and a microphone can be used as a stand-alone tool for environmental studies or to determine physical properties of rocks and soils from shock waves of laser-produced plasmas. SuperCam is built in three parts: The mast unit (MU), consisting of the laser, telescope, RMI, IR spectrometer, and associated electronics, is described in a companion paper. The on-board calibration targets are described in another companion paper. Here we describe SuperCam’s body unit (BU) and testing of the integrated instrument. The BU, mounted inside the rover body, receives light from the MU via a 5.8 m optical fiber. The light is split into three wavelength bands by a demultiplexer, and is routed via fiber bundles to three optical spectrometers, two of which (UV and violet; 245–340 and 385–465 nm) are crossed Czerny-Turner reflection spectrometers, nearly identical to their counterparts on ChemCam. The third is a high-efficiency transmission spectrometer containing an optical intensifier capable of gating exposures to 100 ns or longer, with variable delay times relative to the laser pulse. This spectrometer covers 535–853 nm ( $105\text{--}7070~\text{cm}^{-1}$ Raman shift relative to the 532 nm green laser beam) with $12~\text{cm}^{-1}$ full-width at half-maximum peak resolution in the Raman fingerprint region. The BU electronics boards interface with the rover and control the instrument, returning data to the rover. Thermal systems maintain a warm temperature during cruise to Mars to avoid contamination on the optics, and cool the detectors during operations on Mars.Results obtained with the integrated instrument demonstrate its capabilities for LIBS, for which a library of 332 standards was developed. Examples of Raman and VISIR spectroscopy are shown, demonstrating clear mineral identification with both techniques. Luminescence spectra demonstrate the utility of having both spectral and temporal dimensions. Finally, RMI and microphone tests on the rover demonstrate the capabilities of these subsystems as well.

47 OTHER INSTRUMENTATION↗

High-throughput measurements of CO 2 permeance and solubility in ionic liquid reveal a synergistic role of ionic interactions and void fractions

The factors that govern CO 2 solubility in ionic liquids (ILs) are of great interest for the development of new materials for CO 2 capture and utilization. The cationic functional group (i.e., imidazolium, pyrrolidinium, pyridinium, etc.), alkyl chain length of cation, degree of fluorination of anion, anion size, and the void fraction in IL are known to influence CO 2 solubility. However, a comprehensive explanation of how these factors collectively affect CO 2 solubility has not been developed yet. This knowledge gap is largely attributed to the lack of CO 2 solubility data for IL structures other than imidazolium based ILs. We report here an automated high-throughput (HT) setup for the measurement of CO 2 solubility in room-temperature ILs (RTILs) combining six different anions and nine different cations for a total of 19 different specific ranges of RTILs. The HT setup first dispenses up to 200 µL of RTILs in a 96-well microtiter plate and then utilizes a robotic arm to measure cyclic voltammogram (CV) in each well using maneuverable Ag electrodes. The Cottrell analysis of the CO 2 reduction CV peak provides a direct measurement of CO 2 permeance in RTILs, which yields Henry’s constant from the estimated diffusion coefficient of CO 2 . Henry’s constants thus obtained are in very good agreement with those reported earlier. The measured CO 2 permeance and Henry’s constant of all RTILs seem to follow a first-order dependence on void fraction and a second-order dependence on electrostatic interaction between anion and cation of IL, with some synergistic dependence on the product of a void fraction and electrostatic interaction, making them two important descriptors for the design of novel ILs.

CO2 Solubility↗

Robotic pendant drop: containerless liquid for μs-resolved, AI-executable XPCS

Abstract The dynamics and structure of mixed phases in a complex fluid can significantly impact its material properties, such as viscoelasticity. Small-angle X-ray Photon Correlation Spectroscopy (SA-XPCS) can probe the spontaneous spatial fluctuations of the mixed phases under various in situ environments over wide spatiotemporal ranges (10 −6 –10 3 s /10 −10 –10 −6 m). Tailored material design, however, requires searching through a massive number of sample compositions and experimental parameters, which is beyond the bandwidth of the current coherent X-ray beamline. Using 3.7-μs-resolved XPCS synchronized with the clock frequency at the Advanced Photon Source, we demonstrated the consistency between the Brownian dynamics of ~100 nm diameter colloidal silica nanoparticles measured from an enclosed pendant drop and a sealed capillary. The electronic pipette can also be mounted on a robotic arm to access different stock solutions and create complex fluids with highly-repeatable and precisely controlled composition profiles. This closed-loop, AI-executable protocol is applicable to light scattering techniques regardless of the light wavelength and optical coherence, and is a first step towards high-throughput, autonomous material discovery.

36 MATERIALS SCIENCE↗

Does one need to polish electrodes in an eight pattern? Automation provides the answer

Automation of electrochemical measurements can accelerate the discovery of new electroactive materials. One of the hurdles to automated electrochemical measurement is the pretreatment of electrodes because mechanical polishing is usually conducted manually. Here we investigate the automation of electrochemical measurements using a robotic arm. We demonstrate automated mechanical polishing using a station with a moving polishing pad and evaluate the effect of different polishing patterns. Our automatic method improved the corroded electrodes, and we found the effect of pattern was not significant, which diverges from the current common belief amongst practitioners that a figure eight pattern is best for pretreatment. This research is a step toward automating electrochemistry experiments without human intervention.

Yoshikawa, Naruki [University of Toronto, ON (Cana↗

Robotic sample changers for macromolecular X-ray crystallography and biological small-angle X-ray scattering at the National Synchrotron Light Source II

In this work, we present two robotic sample changers integrated into the experimental stations for the macromolecular crystallography (MX) beamlines AMX and FMX, and the biological small-angle scattering (bioSAXS) beamline LiX. They enable fully automated unattended data collection and remote access to the beamlines. The system designs incorporate high-throughput, versatility, high-capacity, resource sharing and robustness. All systems are centered around a six-axis industrial robotic arm coupled with a force torque sensor and in-house end effectors (grippers). They have the same software architecture and the facility standard EPICS-based BEAST alarm system. The MX system is compatible with SPINE bases and Unipucks. It comprises a liquid nitrogen dewar holding 384 samples (24 Unipucks) and a stay-cold gripper, and utilizes machine vision software to track the sample during operations and to calculate the final mount position on the goniometer. The bioSAXS system has an in-house engineered sample storage unit that can hold up to 360 samples (20 sample holders) which keeps samples at a user-set temperature (277 K to 300 K). The MX systems were deployed in early 2017 and the bioSAXS system in early 2019.

36 MATERIALS SCIENCE↗

A Demonstration of Intelligent Container Surveillance Using Stationary and Mobile Camera Platforms

Surveillance of nuclear material storage containers is required to ensure that the container safety boundary is maintained during the service life of the container. As many of these container types are the first and only containment barrier to release protecting the worker, public, and environment, it is imperative to develop robust surveillance tools to characterize container degradation. Machine learning (ML) techniques have matured quickly in the past decade and are slowly becoming a routine application in data analysis. While more popular architectures have been developed with different applications in mind, these can be easily translated to container surveillance requirements. In this study, we developed a ML model based on the Detectron2 framework to identify slip lid containers and common exterior container defects, primarily dents. Commercial-off-the-shelf cameras are combined into a stationary camera array or are mounted to a robotic arm to provide more mobility for positioning needs. Results from the model evaluations on the images indicate that the stationary camera arrays outperform the accuracy of the mobile camera systems for both individual camera and composite image detections. Overall, however, the detection accuracies of the systems fell short of 50% and were less than satisfactory. Future efforts to improve the system involve focusing on a single camera deployable solution that combines a controllable light source that eliminates one of the biggest environmental factors that influence ML model detection performance. Additional training set collection is planned to build a more robust model that enables accurate detection from a wider range of imaging conditions.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Development of Automated Material Handling System with Alternate Gripper Designs for the Purpose of Increased Performance & Worker Safety

Savannah River National Laboratory’s (SRNL) Surplus Plutonium Disposition (SPD) Program leads the development and transition of automated unit operations for the processing of Plutonium oxide. A mixing can is opened, filled with material, mixed, set inside of a die can, and finally punched into compressed material. Replication of the process is constructed in A-area, where the mixing can weighs 1.6 kg (3.5 lbs.) and the compressed material weighs 4 kg (8.8 lbs.). Due to the constant process of Plutonium disposition, the fatigue on workers and worker dose accumulates quickly over time. SPD aims to automate this process by using a robotic arm to replace the hands-on worker. Automation will: Reduce worker radiation dose; Increase process throughout; Reduce costs for the disposition of Plutonium oxide.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of Automation Technologies for Glovebox Processing, Part 2

Topics • Surplus Plutonium Disposition (SPD) Overview • Robotic Arm Development for Glovebox Operations • Automatic Sphincter Loading System (ASLS) Update Surplus Plutonium Disposition (SPD) Overview • Application Background • Development Scope • Improvement Goals • Limitations

Krementz, Daniel↗

Modular Autonomous Experimentation for Biological Applications

The Modular Autonomous Research System (MARS) was created to address a key challenge in scientific discovery: experiments are often slow, require significant manual labor, and generate data that is not easily integrated across different tools. This limits how quickly scientists can explore new materials, processes, and chemical reactions. Our motivation was to design a system that makes research faster, more reliable, and adaptable by combining automation with artificial intelligence. By doing so, we aimed to reduce human error, accelerate discovery, and allow researchers to quickly test many possibilities that would otherwise take months or years. Our approach was to build a flexible platform that connects laboratory robots, measurement instruments, and a central data system, all guided by artificial intelligence. MARS integrates liquid handling robots, robotic arms, and plate readers with an intelligent decision-making system that chooses the most informative experiments to run next. This creates a closed loop where experiments are performed automatically, the data is analyzed in real time, and new conditions are immediately tested. Through this work, we demonstrated that MARS can carry out multiple experiments with little or no human intervention, adapt to different scientific problems, and handle uncertain or noisy measurements in a robust way. The results show that modular and intelligent automation can significantly accelerate the pace of discovery, providing a model for future self-driving laboratories. This approach addresses the growing scientific need for adaptable, data-driven research platforms that can keep up with the complexity and scale of modern science.

59 BASIC BIOLOGICAL SCIENCES↗

Modular Autonomous Experimentation for Biological Applications (Full Report)

The Modular Autonomous Research System (MARS) was developed to address the pressing need for faster, more reliable, and more adaptable scientific discovery. Traditional experimentation is limited by manual labor, long cycle times, and fragmented data streams, which constrain the ability to explore complex chemical and materials design spaces. To overcome these limitations, we created an integrated, modular platform that combines laboratory robotics, diverse measurement instruments, and a central data infrastructure with artificial intelligence–driven decision-making. The system links liquid handling robots, robotic arms, and optical plate readers into a closed loop where experiments are executed automatically, data is analyzed in real time, and subsequent experimental conditions are adaptively chosen to maximize information gain. Over the course of the project, MARS was validated on two primary test cases—spectroscopic metal–ligand binding assays and peptide-directed mineralization—which highlighted the system’s ability to handle uncertainty and variability in experimental measurements. To further demonstrate modularity and extensibility, we also established additional testbeds in electrochemistry for catalyst discovery and electrolyte formulation for advanced batteries. The results show that MARS can reliably conduct autonomous campaigns with minimal human intervention, adapt to distinct scientific domains, and provide a scalable model for future self-driving laboratories. This work establishes new capabilities for modular, uncertainty-aware automation and directly supports the need for advanced, data-driven research platforms capable of accelerating discovery across a wide range of scientific and national security missions.

59 BASIC BIOLOGICAL SCIENCES↗

Automated Systems for Solvent Extraction

An automated solvent extraction system for the eventual handling of radioactive materials has been designed and procured for rapid, efficient and safe liquid-liquid extraction processes. This system will be configured to carry out liquid-liquid separations from beginning to end, automating tedious and time-consuming tasks such as organic/aqueous phase prep, pH checks, phase separation, and metal ion analysis. The system features advanced liquid handling capabilities, a robotic arm for precise sample transfer, and sophisticated analytical tools including UV-VIS spectrophotometry for real-time monitoring. Additionally, it incorporates automated capping of vials, vortex mixing, and centrifugation to ensure thorough mixing and phase separation. This report provides an overview of the system and general capabilities as well as initial efforts to develop an automated workflow for liquid-liquid separations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Robotic Systems integration for cleanroom SRF assembly at Fermilab

Superconducting Radio Frequency (SRF) cryomodule assembly is a critical process that demands the highest levels of contamination control in a cleanroom to ensure product quality and reliability. Within the cleanroom environment, human-driven activities remain the major source of uncontrolled particulate. Moreover, the precise manual alignment of components often exceeds expected timeframes, increasing the risk of particulate migration into the critical inner space of the SRF resonant cavity, and causing extended discomfort for workers. Automation comes as a natural solution to address these challenges. The goal of this activity is to set up and integrate a robotic system to support cavity coupler installation in the cleanroom environment. Initially, remote control of a 6-axis collaborative robot arm will be implemented as an introductory step towards automation in the cleanroom. Subsequently, the system will be further enhanced by integrating manipulation capabilities through an appropriate end-effector, and computer vision technology to enable accurate pose estimation. This comprehensive approach aims to achieve a fully automated and adaptable assembly process in the partially structured cleanroom environment, thereby enhancing efficiency and mitigating existing challenges for better product quality and workers safety.

42 ENGINEERING↗

A Modular Accelerator Robotics Framework for AD Robotics

Accelerator tunnels, such as the ones at Fermilab, remain highly radioactive after beam shutoff due to induced radiation from the beam. This residual radiation creates a hazardous environment for manual inspection and repair of beamline components. To minimize worker radiation dose and reduce beam downtime, the AD Robotics Initiative previously built a fleet of low-cost custom mobile robots. However, the custom Python sockets server-client architecture lacked standardization, causing development delays and complicating the integration of new sensors and actuators. Here, we developed a modular system using ROS2 and Docker to standardize the teleoperation and control interfaces. This system was validated by implementing a teleoperation controller with real-time, low-latency, and high-definition video feedback. The aim of this framework is for a new feature or even a robot to be integrated into the system simply by documenting the hardware configuration. Current integration of LiDAR, Odometry, and Depth Cameras provides the foundation for Simultaneous Localization and Mapping (SLAM) tasks. Finally, future work involves integration into the accelerator control system and the attachment of a 6 degree-of-freedom robotic arm for telemanipulation.

Rayyan Khan, M. [Fermilab; Rensselaer Poly.; Unlis↗

Local Thermomechanical Processing for Improving Formability of High Strength Aluminum Sheets

Limited room temperature formability hinders the wide-spread use of high strength aluminum alloys in structural body-in-white parts. Stamping or extrusion at warm temperatures or from softer tempers are the current solutions. In this work, our approach is to start with age-hardened sheets from 7xxx and 6xxx family of alloys and improve their formability using local thermomechanical processing only in the regions demanding highest ductility in the forming processes. We achieved local formability improvements with friction stir processing and introduce another process named roller-bending as a concept and showed its feasibility through finite element simulations. Initial results from FSP indicated significant deformation in the processed zones with minimal sheet distortion. FSP also resulted in dynamically recrystallized, fine grained (d < 5 µm) microstructures in the processed regions with textures significantly different from the base material. This resulted in formability improvements of > 30% in 7085-T76 and > 50% in 6111-T6 alloys as measured by minimum bend radius (r/t) ratios established with V-bending tests performed at 90° and 180° bend angles. Based on the encouraging initial results, we envision applicability of these processes in both pre- and post-stamping stages through integration of the process tools as end-effectors to robotic arms.

Nasim, Wahaz↗

Large-scale continuous carbon/glass fiber additive-compression molded composites

Additive Manufacturing (AM) or 3-D printing has advanced from small-scale desktop printers to large-scale printers. Most of the present large-scale printers utilize feedstock materials in the form of pellets to create composite structures. To create structurally robust composite parts, reinforcements in the form of short fibers (carbon or glass) are often used to impart mechanical properties to the printed parts. However, poor mechanical properties in Z-direction and high porosity of pellets-based printed composites compared to composite manufactured using traditional methods are serious concerns. The authors report a combined approach in the present work, where fiber reinforced composites are printed with a high-throughput continuous fiber deposition method followed by a secondary compression molding process. A specially designed end-effector mounted on a robotic arm is used to print composite preforms. Continuous comingled fibers (Thermofiber 12K CF-PA12, Thermofiber 12K S2-PA12, and Hybrid Thermofiber 12K CF-PA12+PEEK PA6) embedded in the thermoplastic nylon matrix are printed to create composite preform plaques. The printed preforms were further compression molded (CM) using a hydraulic hot-press to create highly consolidated composite parts. The mechanical properties of the continuous fiber composites produced by this combined approach are improved significantly due to the highly aligned continuous fibers and reduced porosity. Flexural strength, flexural modulus, and tensile modulus of AM-CM Thermofiber 12K CF-PA12 UD sample were 615.37 MPa, 75.65 GPa, and 122.23 GPa, respectively.

Kumar, Vipin↗