Search NASA⌕ Search

SEARCH · Search NASA

Results for “room-temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Investigation of the Kramers-Kronig analysis - Revised optical constants of AgCl

White and Straley (1968) have reported room-temperature optical constants for AgCl that exhibit negative, unphysical dips at the band edge. Because Morrison (1961) also obtained such behavior for InAs, InSb, and GaAs, a study is made of the possible sources of this anomaly. An artifact of the experimental reflectance data near this energy is found to be responsible. No defect in the Kramers-Kronig transform or its use is implied, contrary to some suggestions. The corrected optical constants of AgCl were modified by about 10% up to 5 eV, whereas at higher energies they were barely affected. Thus Kramers-Kronig-deduced optical constants that exhibit unusual structure are not affected by this structure at other energies. The new AgCl results are presented, and assignments are briefly discussed.

Bauer, R. S.↗

Method of attaching insulation tiles

Felt pads attached underneath tiles add very little weight and retain flexibility at low temperatures. Very thin layer of room-temperature vulcanizing silicone adhesive is applied to tile. Then felt pad is attached to adhesive. Finally, tile-felt combination is attached to metal surface by means of similar adhesive layer.

Leger, L. J.↗

Reaction of sulfur dioxide with modified 440C, studied by Auger electron spectroscopy and depth profiling

Auger electron spectroscopy and sputtering were used to study the interaction of SO2 with modified 440C, which is a nominally 77-wt%-Fe, 14-wt%-Cr, and 4-wt%-Mo bearing steel with C, S, Si, Ni, V, P, and Mn making up the balance. The sample was polycrystalline. Three temperatures were used: room temperature, 500 C, and 600 C. The reaction time was varied from 30 minutes to 2 hours. A surface cleaned of oxides was the starting point for each reaction. For reactions at 500 C, the major constituents Cr, O, Fe, and S were present in the surface film. At 600 C, the principal constituents of the film were Cr, O, and S with no Fe present. Therefore, a transition in film composition occurred between 500 and 600 C. Oxides were the primary constituents of the films at both temperatures. Room-temperature reactions indicated that SO2 adsorbed dissociatively, with approximately equal quantities of S and O on the surface. For the same reaction time (1 hr) and pressure, a strong temperature dependence of film thickness was observed. The film formed at 600 C was approximately seven times thicker than that formed at 500 C.

Ferrante, J.↗

Evaluation of T-111 forced-convection loop tested with lithium at 1370 C

A T-111 alloy (Ta-8% W-2% Hf) forced-convection loop containing molten lithium was operated 3000 hr at a maximum temperature of 1370 C. Flow velocities up to 6.3 m/sec were used, and the results of this forced-convection loop are very similar to those observed in lower velocity thermal-convection loops of T-111 containing lithium. Weight changes were determined at 93 positions around the loop. The maximum dissolution rate occurred at the maximum wall temperature of the loop and was less than 1.3 microns/year. Mass transfer of hafnium, nitrogen, and, to a lesser extent, carbon occurred from the hotter to cooler regions. Exposed surfaces in the highest temperature region were found to be depleted in hafnium to a depth of 60 microns with no detectable change in tungsten content. There was some loss in room-temperature tensile strength for specimens exposed to lithium at 1370 C, attributable to depletion of hafnium and nitrogen and to attendant grain growth.

Devan, J. H.↗

Internal optical losses in very thin CW heterojunction laser diodes

Theoretical calculations are presented showing the relationship between the internal laser absorption and structural parameters appropriate for CW room-temperature lasers. These diodes have submicron-thick recombination regions, and very small spacings between the heat sink and the recombination region to minimize the thermal resistance. The optical loss is shown to be strongly dependent on the degree of radiation confinement to the active region. In particular, absorption in the surface GaAs layer providing the ohmic contact becomes very significant when the intermediate (AlGa)As layer is reduced below about 1 micron. It is further shown that excessive penetration into the GaAs regions gives rise to anomalies in the far-field radiation profiles in the direction perpendicular to the junction plane.

Butler, J. K.↗

Cyclic debonding of unidirectional composite bonded to aluminum sheet for constant-amplitude loading

Cyclic debonding rates were measured during constant-amplitude loading of specimens made of graphite/epoxy bonded to aluminum and S-glass/epoxy bonded to aluminum. Both room-temperature and elevated-temperature curing adhesives were used. Debonding was monitored with a photoelastic coating technique. The debonding rates were compared with three expressions for strain-energy release rate calculated in terms of the maximum stress, stress range, or a combination of the two. The debonding rates were influenced by both adherent thickness and the cyclic stress ratio. For a given value of maximum stress, lower stress ratios and thicker specimens produced faster debonding. Microscopic examination of the debonded surfaces showed different failure mechanisms both for identical adherends bonded with different adhesive and, indeed, even for different adherends bonded with identical adhesives. The expressions for strain-energy release rate correlated the data for different specimen thicknesses and stress ratios quite well for each material system, but the form of the best correlating expression varied among material systems. Empirical correlating expressions applicable to one material system may not be appropriate for another system.

Roderick, G. L.↗

SUMMA hot-ion plasma heating research at NASA Lewis Research Center

The SUMMA superconducting magnetic mirror facility and the associated hot-ion plasma research were described. SUMMA is characterized by intense magnetic fields and a large-diameter working bore (41 cm diameter) with room-temperature access. The goal of the plasma research program is to produce steady-state plasmas of fusion reactor densities and temperatures (but not confinement times). The program includes electrode development to produce a hot, dense, large-volume, steady-state plasma and diagnostics development to document the plasma properties. SUMMA and its hot-ion plasma are ideally suited to develop advanced plasma diagnostics methods. Two such methods whose requirements are well matched to SUMMA are: (1) heavy ion beam probing to measure plasma space potential; and (2) submillimeter wavelength laser Thomson scattering to measure local ion temperature.

Reinmann, J. J.↗

Researches on interactions of satellite-speed helium atoms with aluminum and quartz surfaces

Three major areas were experimentally studied: (1) energy transfer in collisions of satellite-speed (700 m/sec) helium atoms with a cleaned satellite-type aluminum surface was investigated using the molecular-beam technique. Spatial and energy distributions of reflected helium atoms were measured and analyzed, (2) The gross accommodation coefficient for a satellite-speed (7000 m/sec) helium beam entering a 2-inch-diameter aluminum spherical cavity was determined by measuring the exit velocity distribution of the leaving helium atoms using a metastable time-of-flight method. Results indicate that the 7000-m/sec satellite-speed helium atoms entering the cavity gain full accommodation with the room-temperature inner surface of the sphere through a large number of collisions before leaving the spherical cavity; and (3) the feasibility of producing a satellite-speed atomic hydrogen beam by arc-heating, for use in studies of interactions of satellite-surfaces with hydrogen atoms under laboratory conditions, was investigated. It was found that a stable arc-heated molecular hydrogen beam can be obtained using the arc-heater, and that a partially dissociated hydrogen beam can be produced. Photographs of laboratory equipment are shown.

Liu, S. M.↗

SUMMA hot-ion plasma heating research at NASA Lewis Research Center

This report describes the SUMMA superconducting magnetic mirror facility at the NASA Lewis Research Center and the hot-ion plasma research conducted therein. SUMMA is characterized by intense magnetic fields (designed for 8.6 T at the mirrors) and a large-diameter working bore (41 cm diameter) with room-temperature access. The goal of the plasma research program is to produce steady-state plasmas of fusion reactor densities and temperatures (but not confinement times). The program includes electrode development to produce a hot, dense, large-volume, steady-state plasma and diagnostics development to document the plasma properties. SUMMA and its hot-ion plasma are ideally suited to develop advanced plasma diagnostics methods. Two such methods whose requirements are well matched to SUMMA are: (1) heavy ion beam probing to measure plasma space potential, and (2) submillimeter wavelength laser Thomson scattering to measure local ion temperature. Two NASA University Grants were established to identify major requirements for developing these two diagnostic techniques in SUMMA.

Reinmann, J. J.↗

Scattering of high-velocity He and Ar beams by methane, silane, and germane

Fast He and Ar beams have been scattered by room-temperature CH4, SiH4, and GeH4 to obtain average atom-molecule potentials for He-CH4, He-SiH4, He-GeH4, Ar-CH4, and Ar-GeH4. Somewhat unexpectedly, the potential for He-GeH4 was intermediate between He-CH4 and He-SiH4; this apparent discrepancy, however, correlates with the bond polarities. The potential for Ar-CH4 can be satisfactorily predicted from that for He-CH4 by means of simple potential models and combination rules. The analogous prediction for Ar-GeH4 is unsatisfactory; reasons for the discrepancy are discussed.

Amdur, I.↗

Absorption of CO laser radiation by NO

The paper describes absorption calculations and measurements at selected infrared CO laser wavelengths which are nearly coincident with absorption lines in the fundamental vibration-rotation band of NO near 5.3 microns. Initial work was directed towards establishing the optimal CO laser-NO absorption line coincidence for high temperature applications. Measurements of the absorption coefficient at this optimal laser wavelength were carried out, first using a room-temperature absorption cell for high-temperature calculations and then using a shock tube, for the temperature range 630-4000 K, to validate the high temperature calculations.

Hanson, R. K.↗

Crack growth in Ti-8Al-1Mo-1V with real-time and accelerated flight-by-flight loading

Crack growth in Ti-8Al-1Mo-1V was measured and calculated for real-time and accelerated simulations of supersonic airplane loading and heating. Crack-growth rates calculated on the assumption that an entire flight could be represented by a single cycle predicted the experimental rates poorly. Calculated crack-growth rates were slower than the experimental rates for all tests with flight-by-flight loading. For room-temperature accelerated tests, the calculated rates agreed well with the experimental rates; but the calculations became progressively less accurate for progressively more complex test conditions (tests that included elevated temperature). Calculations of crack growth using the crack-closure concept can probably be improved through study of crack-opening stresses using finite-element models that account for variable-amplitude loading, residual stresses, and temperature effects. The calculations of crack growth could also be improved through detailed studies of material properties and interactions among stress, temperature, and time as appropriate for the real-time operating conditions of a supersonic transport airplane.

Imig, L. A.↗

Preliminary Investigation of the Effect of Surface Treatment on the Strength of a Titanium Carbide - 30 Percent Nickel Base Cermet

Specimens of a nickel-bonded titanium carbide cermet were given the following surface treatments: (1) grinding, (2) lapping, (3) blast cleaning, (4) acid roughening, (5) oxidizing, and (6) oxidizing and refinishing. Room-temperature modulus-of-rupture and impact strength varied with the different surface treatments. Considerable strength losses resulted from the following treatments: (1) oxidation at 1600 F for 100 hours, (2) acid roughening, and (3) severe grinding with 60-grit silicon carbide abrasive. The strength loss after oxidation was partially recovered by grit blasting or diamond grinding.

MATERIALS, PROPERTIES - FLEXURE↗

Experimental Study of Heat Transfer to Small Cylinders in a Subsonic, High-temperature Gas Stream

A Nusselt-Reynolds number relation for cylindrical thermocouple wires in crossflow was obtained from the experimental determination of time constants. Tests were conducted in exhaust gas over a temperature range of 2000 to 3400 R, a Mach number range of 0.3 to 0.8, and a static-pressure range from 2/3 to 1-1/3 atmospheres, yielding a Reynolds number range of 450 to 3000. The correlation obtained is Nu=(0.428 plus or minus 0.003) times the square root of Re* with average deviations of a single observation of 8.5 percent. This relation is the same as one previously reported for room-temperature conditions.

GASES, PROPERTIES↗

Effect of Surface Finish on Fatigue Properties at Elevated Temperatures I : Low-carbon N-155 with Grain Size of A.S.T.M. 1

Effect of three surface finishes of roughness 4 to 5, 20 to 25, and 70 to 80 micro inches rms on fatigue properties were determined for low-carbon N-155 alloy of grain size A.S.T.M. 1 at temperatures of 80 , 1000, 1350, and 1500 F. The fatigue properties for the various finishes differed appreciably at room temperature; however, after short periods at 1000 F and for all periods investigated at temperatures above 1000 F, the specimen finishes had the same fatigue strength. It was concluded that the primary cause of the difference in room-temperature strength was due to compressive stresses set up in the surface and that at elevated temperatures these compressive stresses were relieved by annealing. Apparently, roughness alone did not significantly affect fatigue strength.

Ferguson, Robert R↗

Experimental investigation of coolant-flow characteristics of a sintered porous turbine blade

Local cooling-air flow rates through the walls of a sintered porous-metal turbine blade were measured at room temperature for a range of pressure drops. In order to check the validity of the correlation procedure, this procedure was used to correlate air-flow rates thorough two porous disks at temperatures up to 600 degrees F.245:00:Experimental investigation of coolant Data indicate the method permits room-temperature flow data to be used for heat-transfer work at elevated temperatures with reasonable accurach. Cooling-air flow distribution around the periphery of the test blade is presented for two internal cooling air pressures with the blade in a 1000 degrees Fahrenheit gas stream at a cascade-inlet Mach number of 0.45.

Bartoo, Edward R↗

Oxidation-resistance Mechanism and Other Properties of Molybdenum Disilicide

The outstanding oxidation resistance of molybdenum disilicide at 2400 F and above was found to depend on the formation of a protective siliceous coating which a-cristobalie has been identified. Molybdenum disilicide is not inherently resistant to oxidation and in powdered form burns at low temperatures.Melting and casting experiments have demonstrated the decomposition of the material at the melting point. The room-temperature modulus of elasticity has been determined and electric-resistivity data are given to 2000 F.

MATERIALS, PROPERTIES-CORROSION RESISTANCE↗

Compressive Strength of Stainless-Steel Sandwiches at Elevated Temperatures

Experimental results are presented from crippling tests of stainless-steel sandwich specimens in the temperature range from 80 F to 1,200 F. The specimens included resistance-welded 17-7 PH stainless-steel sandwiches with single-corrugated cores, type 301 stainless-steel sandwiches with double-corrugated cores, and brazed 17-7 PH stainless-steel sandwiches with honeycomb cores. The experimental strengths are compared with predicted buckling and crippling strengths. The crippling strengths were predicted from the calculated maximum strength of the individual plate elements of the sandwiches and from a correlation procedure which gives the elevated-temperature crippling strength when the experimental room-temperature crippling strengths are known. Photographs of some of the tested specimens are included to show the modes of failure.

Mathauser, Eldon E.↗