Search NASA⌕ Search

SEARCH · Search NASA

Results for “runaway”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The Runaway Greenhouse Effect on Earth and other Planets

Water vapor is an efficient absorber of outgoing longwave infrared radiation on Earth and is the primary greenhouse gas. Since evaporation increases with increasing sea surface temperature, and the increase in water vapor further increases greenhouse warming, there is a positive feedback. The runaway greenhouse effect occurs if this feedback continues unchecked until all the water has left the surface and enters the atmosphere. For Mars and the Earth the runaway greenhouse was halted when water vapor became saturated with respect to ice or liquid water respectively. However, Venus is considered to be an example of a planet where the runaway greenhouse effect did occur, and it has been speculated that if the solar luminosity were to increase above a certain limit, it would also occur on the Earth. Satellite data acquired during the Earth Radiation Budget Experiment (ERBE) under clear sky conditions shows that as the sea surface temperature (SST) increases, the rate of outgoing infrared radiation at the top of the atmosphere also increases, as expected. Over the pacific warm pool where the SST exceeds 300 K the outgoing radiation emitted to space actually decreases with increasing SST, leading to a potentially unstable system. This behavior is a signature of the runaway greenhouse effect on Earth. However, the SST never exceeds 303K, thus the system has a natural cap which stops the runaway. According to Stefan-Boltzmann's law the amount of heat energy radiated by the Earth's surface is proportional to (T(sup 4)). However, if the planet has a substantial atmosphere, it can absorb all infrared radiation from the lower surface before the radiation penetrates into outer space. Thus, an instrument in space looking at the planet does not detect radiation from the surface. The radiation it sees comes from some level higher up. For the earth#s atmosphere the effective temperature (T(sub e)) has a value of 255 K corresponding to the middle troposphere, above most of the water vapor and clouds. "Additional information is contained in the original extended abstract."

Rabbette, Maura↗

Prevention of lithium-ion battery thermal runaway using polymer-substrate current collectors

Isolating electronically conducting material from internal short circuits is a promising way to prevent the onset of thermal runaway within lithium-ion cells. Here, a metal-coated polymer current collector, which is designed to disconnect internal short circuits by withdrawing from the heating region, is tested in 18650 cells. In addition to having lower mass and manufacturing costs, cells with metal-coated polymer current collectors demonstrate a reduced risk of thermal runaway during nail penetration. High-speed synchrotron X-ray radiography of 18650 cells during nail-penetration testing, in tandem with pre- and post-mortem X-ray computed tomography, provides insights into the function of the current collectors. The results are compared with those of 18650 cells with standard commercial aluminum and copper current collectors. Cells with aluminum-coated polymer current collectors demonstrated 100% success in thermal runaway prevention during nail penetration, retaining a cell voltage >4.00 V, while standard cells consistently experienced thermal runaway.

25 ENERGY STORAGE↗

Sidewall Breach During Lithium-Ion Battery Thermal Runaway Triggered by Cell-to-Cell Propagation Visualized Using High-Speed X-Ray Imaging

With the rapid deployment of Li-ion batteries (LiBs) in a range of applications, it is crucial to ensure their safe operation. Therefore, it is necessary to investigate the rapid thermal runaway failure that LiBs can undergo if improperly operated or subjected to abuse scenarios so that hazardous events can be avoided or mitigated. Sidewall breaches or ruptures of LiBs during thermal runaway are considered the most hazardous failure scenario, resulting in hot abrasive flare from the casing of the cell that can impinge on neighbouring cells and lead to the propagation of thermal runaway throughout a battery pack. Yet, the process leading up to the sidewall breach is not well understood due to the extreme difficulty in visualizing such a failure in commercially relevant cells. With the application of a newly developed chamber for remote-controlled abuse testing of batteries coupled with simultaneous X-ray imaging, we demonstrate here for the first time an in-situ visualization of a sidewall breach. By further applying spatiotemporal mapping techniques, the internal thermal runaway events leading up to the sidewall breach can be analyzed in detail. Subsequently, the speed of the electrode layer delamination could be calculated to a speed of 0.6 m/s. These new insights bring more clarity regarding this phenomenon, that in turn can help battery designers improve battery safety.

battery safety↗

Study of argon expulsion from the post-disruption runaway electron plateau following low-Z massive gas injection in DIII-D

Herein, a 1D radial diffusion model is developed to study the observed rapid expulsion of argon from the runaway electron plateau in the DIII-D tokamak following secondary massive low-Z (D 2 or He) gas injection. The expulsion of argon is found to be caused by further cooling of the background plasma due to the added neutrals, accompanied by recombination of argon ions and greatly increased outward radial transport rate of argon (now dominantly in neutral form) out of the runaway electron beam. After argon expulsion, power loss out of the runaway electron plateau is found to be dominated by neutral transport to the wall (rather than by radiation); this result resolves the power balance discrepancy highlighted in previous work on argon expulsion out of the runaway electron plateau.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wall heating by subcritical energetic electrons generated by the runaway electron avalanche source *

Abstract Subcritical energetic electrons (SEEs) produced by the runaway electron (RE) avalanche source at energies below the runaway threshold are found to be the primary contributor to surface heating of plasma-facing components (PFCs) during final loss events. This finding is supported by theoretical analysis, computational modeling with the Kinetic Orbit Runaway electrons Code (KORC), and qualitative agreement with DIII-D experimental observations. The avalanche source generates significantly more secondary electrons below the runaway threshold, which thermalize rapidly when well-confined. However, during a final loss event, the RE beam impacts the first wall, and SEEs are deconfined before they can thermalize. Additionally, because the energy deposition length decreases faster than energy, the deposited energy density, and thus the maximum PFC surface temperature change, is larger for SEEs than REs. KORC simulations employ an analytic first wall to model particle deconfinement onto a non-axisymmetric wall composed of individual tiles. PFC surface heating is calculated using a 1D model extended to include an energy-dependent deposition length scale. Simulations of DIII-D qualitatively agree with infrared (IR) imaging only when SEEs from the avalanche source are included. These results demonstrate that SEEs are the dominant contributor to PFC surface heating and indicate that the avalanche source plays a critical role in the PFC damage caused during final loss events. The prominence of SEEs also has important implications for interpreting IR imaging, one of the primary diagnostics for RE-wall interaction diagnosis, despite REs dominating the energy and current density. This result improves predictions of wall damage due to post-disruption REs to estimate material lifetime and design RE mitigation systems for ITER and future reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Predicting Maximum Thermal Response in a Li-ion Cell as a Thermal Runaway Predictor for a UAV Fight

As the energy storage devices continue to "pack" more energy in a small space, any damage, battery component failure, manufacturing defect, or electrically abusing the battery can lead to catastrophic thermal runaway events. A catastrophic thermal event in a cell leads to high temperature, in some instances to spewing of battery materials due to gas development from side reactions initiated due to high internal temperatures. Moreover, a thermal runaway can propagate from a single "failed" cell to a whole battery pack, resulting in a more serious event. The commercial and automotive sectors need to mitigate thermal runaway events. An electric aircraft (or air taxi) has no alternative in the event of a failure, so preventing such events is paramount. Currently, battery prognostics algorithms only predict the state-of-charge (SOC) and end-of-life (EOL) of a Li-ion battery in a UAV (unmanned air vehicle), but do not predict the maximum temperature during a flight or the likelihood of thermal runaway. Our current work focuses on adding the thermal model (based on Birkl's OCV model, in Ref. [1]) to the existing hybrid electrochemical model (single-particle model with lumped parameters as in Ref. [2]) to determine end-of-discharge, end-of-life, and maximum temperature during discharge.

Thermal runaway↗

Dataset of mechanically induced thermal runaway measurement and severity level on Li-ion batteries

The deployment of Li-ion batteries covers a wide range of energy storage applications, from mobile phones, e-bikes, electric vehicles (EV) and stationary energy storage systems. However, safety issue such as thermal runaway is always one of the most important concerns to prevent Li-ion batteries from further market penetration. A standardized single-side indentation test protocol was developed to mechanically induce an internal short-circuit. The cell voltage, compressive load, indenter stroke, and temperature at the indentation point are measured in time series. The test data of each cell, along with cell parameters such as dimensions, mass, chemistry, state of charge (SOC), capacity, are integrated together to calculate a thermal runaway severity score from 0 to100. Complete data collection process including the original measured record, test method, severity score calculation scheme is presented in this article. The thermal runaway severity analysis and the more than 100 tested Li-ion battery records provide a good data source for further comparison and ranking of thermal runaway risks.

25 ENERGY STORAGE↗

Unlocking the self-supported thermal runaway of high-energy lithium-ion batteries

Layered Ni-rich LiNi x Mn y Co 1-x-y O 2 (NMC) materials are the most promising cathode materials for Li-ion batteries due to their favorable energy densities. However, the low thermal stability typically caused by detrimental oxygen release leads to significant safety concerns. Determining the pathways of oxygen evolution reaction is essential, as the ideal safety countermeasure is to break the reaction chain of thermal runaway. In this study, we demonstrate that two endogenous pathways of oxygen involved in strong exothermic reactions lead the NMC811|graphite pouch cell to an uncontrollable state, and we quantify the individual contribution of the pathways to thermal runaway. Approximately 41% of thermal-induced oxygen reacts aggressively with ethylene carbonate (EC) at the cathode/electrolyte interface with 16% heat generation, accelerating the self-heating rate and thereby further triggering thermal runaway. The residual oxygen that survives the reaction with carbonate spreads to the lithiated anode with major heat generation (65%), bringing the battery to the maximum destructive temperature during thermal runaway. By confirming the significant roles of EC and anode, a deeper understanding on battery fire was achieved. Finally, the revealed mechanism can help guide studies on stopping the two reaction pathways, allowing for the safer use of high-energy lithium-ion batteries in the future.

25 ENERGY STORAGE↗

Thermal runaway mechanism of lithium-ion battery with LiNi 0.8 Mn 0.1 Co 0.1 O 2 cathode materials

Battery safety is critical to the application of lithium-ion batteries, especially for high energy density battery applied in electric vehicles. In this paper, the thermal runaway mechanism of LiNi 0.8 Co 0.1 Mn 0.1 O 2 based lithium-ion battery is illustrated. And the reaction between cathode and flammable electrolyte is proved as the trigger of the thermal runaway accident. In detail, with differential scanning calorimeter tests for battery components, the material combination contributing to thermal runaway was decoupled. Characterization with synchrotron X-ray diffraction and transmission electron microscopy with in-situ heating proved that the vigorous exothermic reaction is initiated by the liberated oxygen species. The pulse of highly active oxygen species reacted quickly with the electrolyte, accompanied with tremendous heat release, which accelerated the phase transformation of charged cathode. Also, the mechanism is verified by a confirmatory experiment when the highly active oxygen species were trapped by anion receptor, the phase transformation of the charged cathode was inhibited. Clarifying the thermal runaway mechanism of LiNi 0.8 Co 0.1 Mn 0.1 based lithium-ion battery may light the way to battery chemistries of both high energy density and high safety.

25 ENERGY STORAGE↗

Quantitative Analysis and Prediction of Thermal Runaway Metrics of High-Nickel Oxide Cathodes by Machine Learning Models

The pursuit of higher energy density in lithium-ion batteries has made high-nickel (Ni) layered oxides leading cathode candidates for next-generation electric vehicles. However, their poor thermal stability, particularly at Ni contents ≥ 90%, increases the risk of cathode-initiated thermal runaway. Furthermore, we present a data-driven framework combining linear and nonlinear machine learning models to predict key thermal runaway descriptors from a high-throughput differential scanning calorimetry database. With cathode composition and state of charge (SOC) as input features, the ensemble model accurately predicts peak temperature, heat release, and peak heat flow. SHAP analysis identifies Ni content and SOC as the dominant factors controlling thermal runaway temperature, while SOC primarily governs heat release and peak heat flow. Al, Mg, and Mn improve thermal stability by strengthening metal–oxygen bonding and delaying structural transformation, whereas B mainly reduces heat release through surface passivation. Validation with a new cathode composition confirms accurate prediction of SOC-dependent thermal runaway behavior and critical SOC.

25 ENERGY STORAGE↗

Compressional Alfvén eigenmodes excited by runaway electrons

Compressional Alfvén eigenmodes (CAEs) driven by energetic ions have been observed in magnetic fusion experiments. In this paper, we show that the modes can also be driven by runaway electrons formed in post-disruption plasma, which may explain kinetic instabilities observed in DIII-D disruption experiments with massive gas injection. The spatial structure is calculated, as are the frequencies which are in agreement with experimental observations. Using a runaway electron distribution function obtained from a kinetic simulation, the mode growth rates are calculated and found to exceed the collisional damping rate when the runaway electron density exceeds a threshold value. The excitation of CAEs poses a new possible approach to mitigate seed runaway electrons during the current quench and surpassing the avalanche.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Understanding Li-Ion Cell Internal Short Circuit and Thermal Runaway through Small, Slow and In Situ Sensing Nail Penetration

Here we report a small, slow and in situ sensing (3S) nail penetration test method to understand Li-ion cell internal short circuit (ISC) and thermal runaway. The method not only keeps conventional nail penetration's advantage of simple implementation, but also enhances its relevance to field failures and enables detailed in situ diagnosis. It was applied to 3-Ah pouch cells and revealed insights that could not be captured by conventional methods. Most interestingly, multiple in situ temperature peaks were observed during a period of over 100 s before thermal runaway. These initial peaks exceeded safety limit but the temperature rapidly decreased after each peak instead of causing immediate thermal runaway. Further investigation suggested that the initial temperature peaks occurred when nail tip reached aluminum foil current collector to form a low resistance ISC between anode and aluminum foil. The rapid temperature decrease after each peak can be attributed to sudden drop of ISC current, which can be further attributed to rupture of aluminum foil and increase of contact resistance. The findings show that 3S nail penetration test can separate processes of ISC from thermal runaway and provide details of ISC at the level of individual electrode and current collector.

25 ENERGY STORAGE↗

Dynamics of runaway tails with time-dependent sub-Dreicer dc fields in magnetized plasmas

The evolution of runaway tails driven by sub-Dreicer time-dependent dc fields in a magnetized plasma are studied numerically using a quasi-linear code based on the Ritz-Galerkin method and finite elements. It is found that the runaway tail maintained a negative slope during the dc field increase. Depending on the values of the dc electric field at t = 0 and the electron gyrofrequency to the plasma frequency ratio the runaway tail became unstable to the anomalous Doppler resonance or remained stable before the saturation of the dc field at some maximum value. The systems that remained stable during this stage became unstable to the anomalous Doppler or the Cerenkov resonances when the dc field was kept at the saturation level or decreased. Once the instability is triggered, the runaway tail is isotropized.

Moghaddam-Taaheri, E.↗

Mitigating Thermal Runaway Risk in Lithium Ion Batteries

The JSC/NESC team has successfully demonstrated Thermal Runaway (TR) risk reduction in a lithium ion battery for human space flight by developing and implementing verifiable design features which interrupt energy transfer between adjacent electrochemical cells. Conventional lithium ion (li-Ion) batteries can fail catastrophically as a result of a single cell going into thermal runaway. Thermal runaway results when an internal component fails to separate electrode materials leading to localized heating and complete combustion of the lithium ion cell. Previously, the greatest control to minimize the probability of cell failure was individual cell screening. Combining thermal runaway propagation mitigation design features with a comprehensive screening program reduces both the probability, and the severity, of a single cell failure.

Darcy, Eric↗

Enhancing Battery Safety with Fractional Thermal Runaway Calorimetry

Effective thermal management systems, designed to handle the impacts of thermal runaway (TR) and to prevent cell-to-cell propagation, are key to safe operation of lithium-ion (Li-ion) battery assemblies. Critical factors for optimising these systems include the total energy released during a single cell TR event and the fraction of the total energy that is released through the cell casing versus through the ejecta material. A unique fractional thermal runaway calorimeter (FTRC), designed to characterise said critical factors, was utilised to examine the TR behaviour of Li-ion cells). Delegates will be provided with an in-depth discussion on what fractional thermal runaway calorimetry is and how it benefits the development of safe and optimised battery assemblies that protect against thermal runaway. Delegates will see calorimetry data associated with a variety of Li-ion cells. Data presented is relevant to any industry that utilises high-energy Li-ion cells in closed environments and has a need to focus on safety.

Walker, William↗

Simulation of DIII-D disruption with argon pellet injection and runaway electron beam

Abstract The next generation of large tokamaks, including ITER, will be equipped with a disruption mitigation system (DMS) that can be activated if a disruption is deemed to be imminent. Introducing impurities by pellet (large or shattered) or massive gas injection has been shown to be an effective mitigation mechanism on many tokamaks. The goal of the mitigation is to lessen the thermal and electromagnetic loads from the disruption without generating enough high-energy (runaway) electrons to damage the device. Variations of this mitigation process with impurity injection are presently being tested on many experiments. We have modeled one such impurity injection experiment on DIII-D using the M3D-C1 nonlinear 3D extended MHD code (Jardin et al 2012 Comput. Sci. Discovery 6 014002), The model includes an argon large pellet injection and ablation model, impurity ionization, recombination, and radiation, and runaway electron formation and subsequent evolution, including both Dreicer and avalanche sources. We obtain reasonable agreement with the experimental results for the timescale of the thermal and current quench and for the magnitude of the runaway electron plateau formed during the mitigation. This is the first 3D full MHD simulation with pellets and REs to simulate the disruption process and it also provides a partial validation of the M3D-C1 DMS model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of Trigger Method on Fire Propagation during the Thermal Runaway Process in Li-ion Batteries

Lithium-ion batteries are prone to fire hazards due to the possibility of thermal runaway propagation. During battery product development and subsequent safety tests for design validation and safety certification, the thermal runaway onset is triggered by various test methods such as nail penetration, thermal ramp, or external short circuit. This failure initiation method affects the amount of heat contributions and the composition of gas generations. This study compares two such trigger methods, external heating and using a thermally-activated internal short circuit device (ISCD). The effects of the trigger method on total heat generation are experimentally investigated within 18650 cylindrical cells at single cell level as well as at multiple cell configuration level. The severity of failure was observed to be worse for cells with ISCDs at single cell level, whereas quite the opposite results were observed at multiple cell configuration level. A preliminary numerical analysis was performed to better understand the battery safety performance with respect to thermal runaway trigger methods and heat transfer conditions.

25 ENERGY STORAGE↗

Modeling cell venting and gas-phase reactions in 18650 lithium ion batteries during thermal runaway

A numerical model is developed to study cell venting, internal pressure, and gas-phase dynamics behavior of 18650 Li-ion cells undergoing thermal runaway. A k-e Reynolds-Averaged Navier-Stokes (RANS) model is adopted to describe the turbulent flow out of the cells, while the fluid dynamics inside the cells is described by Darcy-Forchheimer's equation. Thermal abuse reactions and gas generation kinetics are described by a single-step lumped reaction model. Then, a series of computational fluid dynamics (CFD) simulations are conducted on a single 18650 cell at various states-of-charge (100%, 50%, 25%) to study detailed flow and thermal behavior as a function of quantity of gas generated during cell venting. Venting events are categorized into two stages: i) breaching of the cell container and ii) thermal runaway reactions. It is found that the cell response is dominated by the second stage since most of the gases are generated during thermal runaway. Also, the propensity for propagation is highly affected by state-of-charge (SOC). Cells at higher SOCs produce more heat and gas during the venting event, owing to higher mass and concentrations of reacting gases, and consequently reach higher internal cell pressures which increase the risk of side-wall breaching.