Search NASA⌕ Search

SEARCH · Search NASA

Results for “safety testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Performance and Safety Tests on Samsung 18650 Li-ion Cells: Two Cell Designs

In order to meet the applications for space shuttle in future, two types of Samsung cells, with capacity 1800 mAh and 2000 mAh, have been investigated. The studies focused on: (1) Performance tests: completed 250 cycles at various combinations of charge/discharge C rates and discharge capacity measurements at various temperatures; and (2) Safety tests: overcharge and overdischarge, heat abuse, short circuit, internal and external short, and vibration, vacuum, and drop tests

Deng, Yi↗

Electron probe microanalysis of irradiated and 1600 deg. C safety-tested AGR-1 Triso fuel particles with low and high retained {sup 110M}Ag - 18570

Advanced Gas Reactor (AGR)-1 fuel Compact 4-3-3 achieved 18.63% FIMA and was exposed to a safety test at 1600 deg. C. Two particles, AGR1-433-003 and AGR1-433-007, with measured-to-calculated {sup 110m}Ag inventories of <22% and 100%, respectively, were selected for electron microprobe analysis to determine whether the distribution or abundance of fission products differed proximally and distally from the deformed kernel in AGR1-433-003 and how this compared to fission product distribution in AGR1-433-007. On the deformed side of AGR1-433-003, xenon, cesium, iodine, europium, strontium, and tellurium concentrations in the kernel buffer interface near the protruded kernel were up to six times higher than on the opposite, non-deformed side. At the silicon carbide (SiC)-inner pyrolytic carbon (IPyC) interface proximal to the deformed kernel, palladium and silver concentrations were 1.2 and 0.04 wt% respectively. On the SiC-IPyC interface distal from the kernel deformation, those elements measured 0.4 and 0.01 wt%, respectively. Palladium and silver concentrations at the SiC-IPyC interface of AGR1-433-007 were 2.05 and 0.05 wt.%, respectively. Rare earth element concentrations at the SiC-IPyC interface of AGR1-433-007 were ten times higher than at the SiC-IPyC interfaces measured in AGR1-433-003. Palladium permeated the SiC layer of AGR1-433-007 and the SiC layer of the non-deformed side of AGR1-433-003. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Reserve Li/SOC12 Battery Safety Testing

A reserve Lithium/Thionyl Chloride Battery concept is developed and undergoing feasibility testing in terms of performance, safety and abusive conditions. The feasibility of employing a battery of this type to replace thermal batteries in certain applications is demonstrated. Excellent performance of a Li/SOCl2 reserve battery is obtained across the temperature range from 0 C to +44 C. Performance improvement over the thermal battery usage is greater by a factor of 3 when discharge time and energy density are compared. Performance over an expanded temperature range is also possible. Safety and abusive testing is accomplished successfully on a series of five units. Further performance improvements can be achieved with regard to battery weight and volume reductions.

Dils, C. T.↗

Enhancing Flight Test Safety with Real-Time Early Warning Techniques

Contemporary approaches to aerospace vehicle system monitoring rely heavily on thresholds that represent a compromise between providing warning early enough to avert a mishap while simultaneously minimizing false alarms. While this reliance on thresholds has been in place for decades and has permeated both cockpits and control rooms, we often find it insufficient when retrospectively analyzing data from an accident. To modernize and enhance flight test safety, we introduce new methods of monitoring for anomalous patterns of interaction rather than for thresholds exceedance. For systems with a well characterized baseline we show how the Inductive Monitoring System (IMS), utilized by NASA in the aftermath of the Columbia accident, might be implemented in real-time to provide earlier warning than currently employed techniques. For systems without such a baseline, we introduce new developments in statistical methods relating to critical slowing down, first applied in medicine and physics, which show promise for adaptation to flight test. Finally, the familiar resource constrained environment leads to a reliance on increased instrumentation that is challenging the limits of the current "one-sensor, one-indicator" threshold paradigm. Existing methods thus fail to accurately reflect the true complexity of a vehicle rich with interdependent interacting systems. We highlight these concepts in a brief summary of the 2001 Air Transat Flight 236 deadstick landing in the Azores. We then suggest control room and cockpit modifications to better display the information gleaned using these novel monitoring methods.

Javorsek, Daniel, II↗

Safety Testing of AGR-5/6/7 Compacts 2-2-2 and 2-2-4

Compacts 2-2-2 and 2-2-4 from the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program’s final irradiation campaign (AGR-5/6/7) were each separately subjected to a thermal soak at 1600°C for 300 h under flowing helium to simulated conditions experienced during a postulated high-temperature gas-cooled reactor (HTGR) depressurization conduction cooldown event. The safety testing of the fuel compacts’ performance under accident conditions was conducted in the Oak Ridge National Laboratory (ORNL) Core Conduction Cooldown Test Facility (CCCTF), which utilizes a stand-alone hot cell at the Irradiated Fuels Examination Laboratory (IFEL). The CCCTF heats fuel to temperatures up to 1900°C in a non-oxidizing environment while continuously monitoring the sweep gas for radioactive 85 Kr to detect release levels associated with hermetic failure of the tristructural-isotropic (TRISO) coating surrounding each fuel kernel. In addition, certain metallic radionuclides that escape the fuel compact are collected on deposition cups that are periodically exchanged with a new cup to obtain information on the overall retention behavior of the TRISO coating layers. Because cesium can diffuse through intact pyrocarbon layers, abnormal degradation of the silicon carbide (SiC) layer in the absence of holistic TRISO coating failure is indicated by release of 134 Cs at levels equivalent to an individual particle inventory in the absence of significant 85 Kr release (Hunn et al. 2014). Additional description of the CCCTF system is provided in Appendix A.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Redistribution of radionuclides in irradiated AGR-1 UCO TRISO fuel after 1800 °C safety testing

Release of radionuclides from intact tristructural-isotropic (TRISO) coated particle fuel at normal and accident conditions is a primary metric of fuel performance. The distribution of fission products and actinides in the TRISO layers of individual particles provides insight on radionuclide transport and release behavior and was determined using scanning electron microscopy analysis. Particles were isolated from an irradiated fuel compact (AGR-1 Compact 4-4-2) and analyzed as-irradiated or after individual particle safety-testing at 1800 °C for 650 h. Particles were selected for comparison based on their remaining 110mAg fission product inventory. These comparisons corroborated the observation that the 110m Ag inventory is a marker for relative irradiation temperature based on observed radionuclide distribution in the SiC layer. The comparison also indicated that the in-pile behavior influences the fission product and actinide species interactions with the TRISO layers during high temperature exposure after irradiation. The analysis confirms both palladium and uranium diffusion, as well as other species, are active in the UCO TRISO fuel system at 1800 °C and that palladium transport is active at lower temperatures relative to uranium. While diffusion across the SiC layer was observed, the intact nature of the SiC layer after the 1800 °C, 650-h exposure indicates the SiC layer maintained its functionality as a fission product barrier by mitigating release of radionuclides at beyond accident margin temperatures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Safety Test on Loose Particles from Irradiated Compact 4-4-2

Post-irradiation examination (PIE) is being carried out on coated particle fuel compacts from the first Advanced Gas Reactor (AGR) Fuel Development and Qualification irradiation experiment (AGR-1). The Oak Ridge National Laboratory (ORNL) Core Conduction Cooldown Test Facility (CCCTF) has been used to evaluate the effect of elevated temperature on the fuel microstructure and fission product retention by heating compacts to maximum temperatures of 1600, 1700, or 1800°C for typically 300 hours, where 1600°C is the expected maximum temperature during a high-temperature gas-cooled reactor (HTGR) depressurization conduction cooldown event, while 1700 and 1800°C explore the performance margin. After completing eleven standard safety tests, a different type of experiment was conducted [INL/PLN4650], where, rather than heating an entire as-irradiated fuel compact, loose particles were tested after deconsolidation of a compact and separation of the particles from the compact matrix.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FFTF Passive Safety Test Data for Benchmarks for New LMR Designs

Liquid Metal Reactors (LMRs) continue to be considered as an attractive concept for advanced reactor design. Software packages such as SASSYS are being used to im-prove new LMR designs and operating characteristics. Significant cost and safety im-provements can be realized in advanced liquid metal reactor designs by emphasizing inherent or passive safety through crediting the beneficial reactivity feedbacks associ-ated with core and structural movement. This passive safety approach was adopted for the Fast Flux Test Facility (FFTF), and an experimental program was conducted to characterize the structural reactivity feedback. The FFTF passive safety testing pro-gram was developed to examine how specific design elements influenced dynamic re-activity feedback in response to a reactivity input and to demonstrate the scalability of reactivity feedback results to reactors of current interest. The U.S. Department of En-ergy, Office of Nuclear Energy Advanced Reactor Technology program is in the pro-cess of preserving, protecting, securing, and placing in electronic format information and data from the FFTF, including the core configurations and data collected during the passive safety tests. Benchmarks based on empirical data gathered during operation of the Fast Flux Test Facility (FFTF) as well as design documents and post-irradiation examination will aid in the validation of these software packages and the models and calculations they produce. Evaluation of these actual test data could provide insight to improve analytical methods which may be used to support future licensing applications for LMRs

Wootan, David W.↗

Fire Safety Tests for Spherical Resorcinol Formaldehyde Resin: Data Summary Report

A draft safety evaluation of the scenario for spherical resorcinol-formaldehyde (SRF) resin fire inside the ion exchange column was performed by the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Fire Safety organization. The result of this draft evaluation suggested a potential change of the fire safety classification for the Cesium Ion Exchange Process System (CXP) emergency elution vessels, equipment, and piping, which may be overly bounding based on the fire performance data from the manufacturer of the ion exchange resin selected for use at the WTP. To resolve this question, the fire properties of the SRF resin were measured by Southwest Research Institute (SwRI), following the American Society for Testing and Materials (ASTM) standard procedures, through a subcontract managed by Pacific Northwest National Laboratory (PNNL). For some tests, the ASTM standard procedures were not entirely appropriate or practical for the SRF resin material, so the procedures were modified and deviations from the ASTM standard procedures were noted. This report summarizes the results of fire safety tests performed and reported by SwRI. The efforts by PNNL were limited to summarizing the test results provided by SwRI into one consolidated data report. All as-received SwRI reports are attached to this report in the Appendix. Where applicable, the precision and bias of each test method, as given by each ASTM standard procedure, are included and compared with the SwRI test results of the SRF resin.

cesium ion exchange↗

SMALL-SCALE SAFETY TEST REPORT FOR RDX (SECOND CALIBRATION)

RDX was provided by Indian Head and was dried at 60 C for 16 hours, cooled and kept in a desiccator before use. Please note that the impact testing was done on both pellets and loose powder which resulted in different data. The impact sensitivity on pressed pellets was 34 cm that is greater than that on loose powder, as expected. The impact test data on the loose powder was similar to what Indian Head and LANL got. Remarkable consistent results were observed for test results of loose powder RDX. The average impact sensitivyt (DH{sub 50}) was 21.8 cm and the average friction sensitivity (F{sub 50}) for loose powder was 24.9 kg, respectively. DSC charts showed that peak temperatures and onset temperatures for all 3 runs of RDX samples were almost identical. All electrostatic spark sensitivity was 0/10 at 1.0 J with a 510-ohm resistor in the discharge circuit.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A BRIEF DESCRIPTION OF THE SMALL-SCALE SAFETY TESTING SYSTEMS AT LAWRENCE LIVERMORE NATIONAL LABORATORY

Small-scale sensitivity testing is important for determining material response to various stimuli including impact, friction, and static spark. These tests, briefly described below, provide parameters for safety in handling. ERL Type 12 drop hammer equipment at LLNL, shown in Figure 1, was used to determine the impact sensitivity. The equipment includes a 2.5-kg drop weight, a striker (upper anvil, 2.5 kg for solid samples and 1.0 kg for liquid samples), a bottom anvil, a microphone sensor, and a peakmeter. For each drop, sample (35 mg for solid or 45 microliter for liquid) is placed on the bottom anvil surface and impacted by the drop weight from different heights. Signs of reactions upon impact are observed and recorded. These signs include noises, flashes or sparks, smoke, pressure, gas emissions, temperature rise due to exothermic reaction, color change of the sample, and changes to the anvil surface (noted by inspection). For solid samples, a 'GO' was defined as a microphone sensor (for noise detection) response of {ge} 1.3 V as measured by a peakmeter. The higher the DH{sub 50} values, the lower the impact sensitivity. The method used to calculate DH{sub 50} values is the 'up and down' or Bruceton method. PETN and RDX have impact sensitivities of 15 and 35 cm, respectively. TATB has impact sensitivity more than 177 cm. For liquid samples, a 'GO' was determined by the noise levels as measured by the peakmeter, appearance of flashes, temperature rise of the anvil, and visual inspection of the anvil surface. Two liquid samples TMETN and FEFO have impact sensitivities of 14 and 32 cm, respectively. Figure 2 shows a 'GO' event observed during the impact sensitivity test; flashes appeared as the drop weight impacted the sample. A BAM friction sensitivity test machine, as shown in Figure 3, was used to determine the frictional sensitivity. The system uses a fixed porcelain pin and a movable porcelain plate that executes a reciprocating motion. Weight affixed to a torsion arm allows for a variation in applied force between 0.5 kg to 36.0 kg. The relative measure of the frictional sensitivity of a material is based upon the smallest load (kg) at which reaction occurs for a 1-in-10 series of attempts. The lower the load values, the higher the frictional sensitivity. PETN has a frictional sensitivity of 6.4 kg. The static spark machine at LLNL is used to evaluate the electrostatic discharge hazards (human ESD) associated with the handling of explosives. The machine was custom-built almost 30 years ago and consists of a capacitor bank (up to 20,000 pF), a voltage meter, and a discharge circuit, as shown in Figure 4. An adjustable resistor up to 510 ohms (chosen to simulate human body) is wired to the discharge circuit. A 5-mg sample is placed in a Teflon washer sealed to a steel disc and covered with a Mylar tape. High static voltage (up to 10 kv) is applied and discharged to the sample. Evidence of reaction is judged from the condition of Mylar tape, smokes, and color change of the sample. Voltage, capacitance, and resistance can be adjusted to achieve the desired static energy. The results obtained are expressed as a zero in 10 or one-in-ten at a specific voltage and joules. One reaction in ten trials at {le} 0.25 joules is considered spark-sensitive. Primary explosives show reaction at 0.1 joule.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Safety testing of AGR-2 UO 2 compacts 3-3-2 and 3-4-2

Post-irradiation examination (PIE) is in progress on tristructural-isotropic (TRISO) coated-particle fuel compacts from the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program second irradiation experiment (AGR-2) [Collin 2014]. The AGR-2 PIE will build upon new information and understanding acquired throughout the recently-concluded six-year AGR-1 PIE campaign [Demkowicz et al. 2015] and establish a database for the different AGR-2 fuel designs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improvements in safety testing of lithium cells

A systematic approach was developed for evaluating the basic safety parameters of high power lithium soluble cathode cells. This approach consists of performing a series of tests on each cell model during the design, prototype and production phases. Abusive testing is performed in a facility where maximum protection is given to test personnel.

Stinebring, R. C.↗

Large-Scale Spacecraft Fire Safety Tests

An international collaborative program is underway to address open issues in spacecraft fire safety. Because of limited access to long-term low-gravity conditions and the small volume generally allotted for these experiments, there have been relatively few experiments that directly study spacecraft fire safety under low-gravity conditions. Furthermore, none of these experiments have studied sample sizes and environment conditions typical of those expected in a spacecraft fire. The major constraint has been the size of the sample, with prior experiments limited to samples of the order of 10 cm in length and width or smaller. This lack of experimental data forces spacecraft designers to base their designs and safety precautions on 1-g understanding of flame spread, fire detection, and suppression. However, low-gravity combustion research has demonstrated substantial differences in flame behavior in low-gravity. This, combined with the differences caused by the confined spacecraft environment, necessitates practical scale spacecraft fire safety research to mitigate risks for future space missions. To address this issue, a large-scale spacecraft fire experiment is under development by NASA and an international team of investigators. This poster presents the objectives, status, and concept of this collaborative international project (Saffire). The project plan is to conduct fire safety experiments on three sequential flights of an unmanned ISS re-supply spacecraft (the Orbital Cygnus vehicle) after they have completed their delivery of cargo to the ISS and have begun their return journeys to earth. On two flights (Saffire-1 and Saffire-3), the experiment will consist of a flame spread test involving a meter-scale sample ignited in the pressurized volume of the spacecraft and allowed to burn to completion while measurements are made. On one of the flights (Saffire-2), 9 smaller (5 x 30 cm) samples will be tested to evaluate NASAs material flammability screening tests. The first flight (Saffire-1) is scheduled for July 2015 with the other two following at six-month intervals. A computer modeling effort will complement the experimental effort. Although the experiment will need to meet rigorous safety requirements to ensure the carrier vehicle does not sustain damage, the absence of a crew removes the need for strict containment of combustion products. This will facilitate the first examination of fire behavior on a scale that is relevant to spacecraft fire safety and will provide unique data for fire model validation.

Combustion↗

High-temperature safety testing of irradiated AGR-1 Triso fuel - 18595

Three irradiated AGR-1 UCO TRISO fuel compacts were tested using a time-varying temperature profile with a peak temperature of 1695 deg. C, simulating a conduction cooldown event in a gas-cooled reactor. Of the approximately 12,378 fuel particles in this test, less than a single particle s inventory of Cs, Eu, Kr or Sr was released during the test, indicating that all TRISO layers in all particles remained intact. The transient nature of the test did not stress the fuel beyond what has been observed in isothermal tests within the same temperature range. It is anticipated that tests of this nature will be repeated using fuel from subsequent irradiations (e.g. AGR-2, which has both UCO and UO{sub 2} fuel compacts, and AGR-5/6/7, which has only UCO fuel). (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

HIGH BURNUP FUEL-COOLANT INTERACTION ANALYSIS SUPPORTING FUEL SAFETY TESTING AT IDAHO NATIONAL LABORATORY

In the near future, experiments on HBu fuel under loss-of-coolant accident (LOCA) and reactivity-initiated accident (RIA) conditions will be performed within the Transient Reactor Test Facility (TREAT) at Idaho National Laboratory (INL). These experiments will be performed using the Transient Water Irradiation System for TREAT (TWIST) experiment vehicle. To support these experiments, analysis of fuel-coolant interaction (FCI) energetics is underway. This paper discusses FCIs in the context of light water reactor (LWR) safety, differentiating between the severe accident focus of commercial reactors and experimental RIA test programs where FCIs have occurred. However, it is highlighted that as the nuclear industry aims for increased burnup limits, the FCI events observed in RIA test programs may become relevant to commercial LWR safety analysis. The paper then presents developments to the UW-FCI computer program to enable simulation of FCIs initiated by solid fuel particles dispersing into the coolant during RIAs.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Very high temperature measurements: Applications to nuclear reactor safety tests; Mesures des tres hautes temperatures: Applications a des essais de surete des reacteurs nucleaires

This PhD dissertation focuses on the improvement of very high temperature thermometry (1100 deg. C to 2480 deg. C), with special emphasis on the application to the field of nuclear reactor safety and severe accident research. Two main projects were undertaken to achieve this objective: - The development, testing and transposition of high-temperature fixed point (HTFP) metal-carbon eutectic cells, from metrology laboratory precision (±0.001 deg. C) to applied research with a reasonable degradation of uncertainties (±3-5 deg. C). - The corrosion study and metallurgical characterization of Type-C thermocouple (service temp. 2300 deg. C) prospective sheath material was undertaken to extend the survivability of TCs used for molten metallic/oxide corium thermometry (below 2000 deg. C)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗