Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample delivery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Advanced manufacturing provides tailor-made solutions for crystallography with x-ray free-electron lasers

Serial crystallography at large facilities, such as x-ray free-electron lasers and synchrotrons, evolved as a powerful method for the high-resolution structural investigation of proteins that are critical for human health, thus advancing drug discovery and novel therapies. However, a critical barrier to successful serial crystallography experiments lies in the efficient handling of the protein microcrystals and solutions at microscales. Microfluidics are the obvious approach for any high-throughput, nano-to-microliter sample handling, that also requires design flexibility and rapid prototyping to deal with the variable shapes, sizes, and density of crystals. Here, we discuss recent advances in polymer 3D printing for microfluidics-based serial crystallography research and present a demonstration of emerging, large-scale, nano-3D printing approaches leading into the future of 3D sample environment and delivery device fabrication from liquid jet gas-dynamic virtual nozzles devices to fixed-target sample environment technology.

36 MATERIALS SCIENCE↗

Megahertz single-particle imaging at the European XFEL

The emergence of high repetition-rate X-ray free-electron lasers (XFELs) powered by superconducting accelerator technology enables the measurement of significantly more experimental data per day than was previously possible. The European XFEL is expected to provide 27,000 pulses per second, over two orders of magnitude more than any other XFEL. The increased pulse rate is a key enabling factor for single-particle X-ray diffractive imaging, which relies on averaging the weak diffraction signal from single biological particles. Taking full advantage of this new capability requires that all experimental steps, from sample preparation and delivery to the acquisition of diffraction patterns, are compatible with the increased pulse repetition rate. Here, we show that single-particle imaging can be performed using X-ray pulses at megahertz repetition rates. The results obtained pave the way towards exploiting high repetition-rate X-ray free-electron lasers for single-particle imaging at their full repetition rate.

36 MATERIALS SCIENCE↗

Development and modeling for a small-scale, rapidly heated high explosives initiation time (HEIT) experiment

Most small-scale assessments of explosive sensitivity, including the popular drop-weight impact test, convolute thermal and mechanical phenomena to the extent that it has been extremely challenging to decipher how an explosive ignites and propagates reactions. For instance, an impact generates heat through a range of dissipation mechanisms, which can in turn, depending on the reaction rates of the explosive, lead to chemical decomposition. To deconvolute the various contributions to the sub-shock initiation and propagation of explosive reactions, we describe the development and modeling of the High Explosives Initiation Time (HEIT) test - a new, small-scale, high-throughput experiment designed to rapidly heat milligram quantities of energetic materials confined within small diameter steel needles. Specifically, we have modeled and designed a 250 joule pulsed power system capable of rapidly delivering electrical current to the needles, resulting in rapid heat delivery to the sample. In conclusion, the energy deposition rate into the sample is controlled by different transmission line topologies. Modeling in COMSOL is performed to understand the energy required to heat up the explosive sample.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparing serial X-ray crystallography and microcrystal electron diffraction (MicroED) as methods for routine structure determination from small macromolecular crystals

Innovative new crystallographic methods are facilitating structural studies from ever smaller crystals of biological macromolecules. In particular, serial X-ray crystallography and microcrystal electron diffraction (MicroED) have emerged as useful methods for obtaining structural information from crystals on the nanometre to micrometre scale. Despite the utility of these methods, their implementation can often be difficult, as they present many challenges that are not encountered in traditional macromolecular crystallography experiments. Here, XFEL serial crystallography experiments and MicroED experiments using batch-grown microcrystals of the enzyme cyclophilin A are described. The results provide a roadmap for researchers hoping to design macromolecular microcrystallography experiments, and they highlight the strengths and weaknesses of the two methods. Specifically, we focus on how the different physical conditions imposed by the sample-preparation and delivery methods required for each type of experiment affect the crystal structure of the enzyme.

36 MATERIALS SCIENCE↗

Testing of a 15 kA Superconducting Transformer

Here, the manufacturing of superconducting magnets for High Energy Physics (HEP) and Fusion Energy Sciences (FES) applications requires high-current conductors to generate stronger magnetic fields without increasing the inductance of the magnet. Increased inductance is undesirable due to the associated AC losses, which reduce the temperature margin; and the quench protection also becomes complicated. Testing high-current conductors with a direct current (DC) room temperature power supply is unfeasible for two primary reasons: 1) the limited capacity to supply large currents, and 2) the significant heat load losses at the current leads. A superconducting transformer offers a solution to both challenges. A 50-kA superconducting transformer is planned for manufacturing and commissioning at Brookhaven National Laboratory as part of its user facility upgrade. This transformer will facilitate the testing of superconducting cables, conductors, joints, and insert coils under high magnetic field conditions (10 T) and with currents up to 50-kA. To evaluate the manufacturing process and validate the theoretical models, the magnet division has developed and tested a 15-kA prototype transformer. A control loop has been implemented to ensure precise current delivery to the sample. This paper presents the coil design, manufacturing, and experimental results from the cold tests.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Method and apparatus for in situ synthesis of SiC, SiC ceramic matrix composites, and SiC metal matrix composites during additive manufacturing

Methods and apparatuses for in situ synthesis of SiC, CMCs, and MMCs are disclosed, comprising: providing an apparatus having: an electromagnetic energy source; an autofocusing scanner; a powder system for SiC and one or more powders; a powder delivery system; a shielding gas comprising argon and/or nitrogen; and a computer coupled to and configured to control the energy source, scanner, powder system, and powder delivery system to deposit layers of the sample; programming the computer with specifications of the sample; using the computer to control electromagnetic radiation, mixing ratio, and powder deposition parameters based on the specifications of the sample; and using the autofocusing scanner to focus and scan the electromagnetic radiation onto the sample while the powders are concurrently deposited by the powder delivery system onto the sample to create a melting pool to deposit one or more layers onto the sample. Other embodiments are described and claimed.

Liu, Jian↗

A Platform for Atomic Fabrication and In Situ Synthesis in a Scanning Transmission Electron Microscope

Here, the engineering of quantum materials requires the development of tools able to address various synthesis and characterization challenges. These include the establishment and refinement of growth methods, material manipulation, and defect engineering. Atomic-scale modification will be a key enabling factor for engineering quantum materials where desired phenomena are critically determined by atomic structures. Successful use of scanning transmission electron microscopes (STEMs) for atomic scale material manipulation has opened the door for a transformed view of what can be accomplished using electron-beam-based strategies. However, serious obstacles exist on the pathway from possibility to practical reality. One such obstacle is the in situ delivery of atomized material in the STEM to the region of interest for further fabrication processes. Here, progress on this front is presented with a view toward performing synthesis (deposition and growth) processes in a scanning transmission electron microscope in combination with top-down control over the reaction region. An in situ thermal deposition platform is presented, tested, and deposition and growth processes are demonstrated. In particular, it is shown that isolated Sn atoms can be evaporated from a filament and caught on the nearby sample, demonstrating atomized material delivery. This platform is envisioned to facilitate real-time atomic resolution imaging of growth processes and open new pathways toward atomic fabrication.

36 MATERIALS SCIENCE↗

Design and Commissioning of a Deuterium-Tritium Gas Delivery System for Muon Catalyzed Fusion in a Diamond Anvil Cell

We report the design, commissioning, and operation of deuterium-deuterium (DD) and deuterium-tritium (DT) gas delivery systems developed to load a diamond anvil cell (DAC) beam target for muon-catalyzed fusion (muCF). The DAC approach enables DT fuel to be compressed to GPa pressures at more than twice the liquid density and heated from cryogenic temperatures through 500 K, opening access to a substantially expanded parameter range for muCF kinetics and yield measurements. In this approach, DT is cryo-condensed to a liquid in a minichamber and then compressed in the DAC using a helium-driven pneumatic membrane, achieving high pressures in a millimeter-scale DT sample volume. A DD gas delivery system was designed and used to validate the experimental apparatus, measure the gas quantities needed for filling, develop operational experience, and collect kinetics and yield data with DD targets. The DT gas delivery system adds tritium-specific capabilities for inventory minimization, secondary containment, and activity monitoring. The DT system integrates depleted uranium storage beds and a liquid helium cryogenic condenser used for pressure building and cryopumping. High-purity delivery is provided by a rapid-response palladium permeator. The system is housed in a helium-atmosphere glovebox held at negative pressure with continuous cleanup. We present the process and instrumentation design, a failure modes and effects analysis (FMEA), and data from the experiment's in situ Raman spectrometer, which provides direct confirmation of target loading and composition through the optically clear diamond anvils. The 2024 and 2025 DT campaigns achieved repeatable target fills and operation with no measurable tritium releases to the stack, demonstrating safe, high-purity DT loading at novel density-temperature conditions for muCF studies.

Koukina, Elena [Acceleron Fusion]↗

Formal methods approach to the charging facility location problem for battery electric vehicles

Battery electric vehicles (BEVs) are becoming more prevalent as improvements in battery technology and energy management continue to be made. As the number of electric vehicles grows, the demand for fast-charging stations is expected to increase dramatically. Thus, building new charging station infrastructure efficiently will be key to reducing upfront costs while meeting consumer demands. In this work, we propose a method for choosing a set of charging station locations that are optimized based on a set of given common vehicle demand points. As part of this solution, we also offer a novel abstraction of the road network on which energy-efficient paths that account for charge-time delays may be found. The current algorithm chooses the optimal charging locations for a single agent which has a route objective specified using temporal logic. To demonstrate the proposed method, the running example shows how a charging station could be chosen for an electric delivery vehicle. Simulations were run on sample road networks with a given set of demand points to service and potential charging station locations to compare. The method is shown to successfully rank potential charging stations in terms of their expected average charging time cost.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Tests of a High Temperature Sample Conditioner for the Waste Treatment Plant LV-S2, LV S3, HV S3A and HV-S3B Exhaust Systems

Tests were performed to evaluate a sample conditioning unit for stack monitoring at Hanford Tank Waste Treatment and Immobilization Plant (WTP) exhaust stacks with elevated air temperatures. The LV-S2, LV-S3, HV-S3A and HV-S3B exhaust stacks are expected to have elevated air temperature and dew point. At these emission points, exhaust temperatures are too high to deliver the air sample directly to the required stack monitoring equipment. As a result, a sample conditioning system is considered to cool and dry the air prior to its delivery to the stack monitoring system. The method proposed for the sample conditioning is a dilution system that will introduce cooler, dry air to the air sample stream. This method of sample conditioning is meant to reduce the sample temperature while avoiding condensation of moisture in the sample stream. An additional constraint is that the ANSI/HPS N13.1-1999 standard states that at least 50% of the 10 µm aerodynamic diameter (AD) particles present in the stack free stream must be delivered to the sample collector. In other words, depositional loss of particles should be limited to 50% in the sampling, transport, and conditioning systems. Based on estimates of particle penetration through the LV-S3 sampling system, the diluter should perform with about 80% penetration or better to ensure that the total sampling system passes the 50% or greater penetration criterion.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Establishing the Quality Assurance programme for the strip sensor production of the ATLAS tracker upgrade including irradiation with neutrons, photons and protons to HL-LHC fluences

The successful pre-production delivery of strip sensors for the new Inner Tracker (ITk) for the upgraded ATLAS detector at the High Luminosity LHC (HL-LHC) at CERN was completed and based on their performance full production has commenced. The overall delivery period is anticipated to last 4 years to complete the approximately 22000 sensors required for the ITk. For Quality Assurance (QA), a number of test structures designed by the collaboration, along with a large area diode and miniature version of the main sensor, are produced in every wafer by the foundry Hamamatsu Photonics K.K (HPK). As well as Quality Control (QC) checks on every main sensor, samples of the QA pieces from each delivery batch are tested both before and after irradiation with results after exposure to neutrons, gammas or protons to fluences and doses corresponding to those anticipated after operation at the HL-LHC to roughly 1.5 times the ultimate integrated luminosity of 4000 fb -1 . In this paper the procedures are presented and the studies carried out to establish that the seven ITk QA Strip Sensor irradiation and test sites meet all the requirements to support this very extensive programme throughout the strip sensor production phase for the ITk project.

47 OTHER INSTRUMENTATION↗

Following O and OH in He/O 2 and He/H 2 O gas mixtures—from the gas phase through the liquid phase to modifications on a biological sample

Abstract Applied cold atmospheric plasma allows for the controlled delivery of reactive oxygen and nitrogen species tailored for specific applications. Through the manipulation of the plasma parameters, feed gases, and careful consideration of the environment surrounding the treatment target, selective chemistries that preferentially influence the target can be produced and delivered. To demonstrate this, the COST reference microscale atmospheric pressure plasma jet is used to study the generation and transport of O and ⋅ OH from the gas phase through the liquid to the biological model target cysteine. Relative and absolute species densities of ⋅ OH and O are measured in the gas phase through laser induced fluorescence (LIF) and two-photon absorption LIF respectively. The transport of these species is followed into the liquid phase by hydrogen peroxide quantification and visualized by a fluorescence assay. Modifications to the model biological sample cysteine exposed to ⋅ OH and H 2 O 2 dominated chemistry (He/H 2 O (0.25%)) and O dominated chemistry (He/O 2 (0.6%)) is measured by FTIR spectroscopy. The origin of these species that modify cysteine is considered through the use of heavy water (H 2 18 O) and mass spectrometry. It is found that the reaction pathways differ significantly for He/O 2 and He/H 2 O. Hydrogen peroxide is formed mainly in the liquid phase in the presence of a substrate for He/O 2 whereas for He/H 2 O it forms in the gas phase. The liquid chemistry resulting from the He/O 2 admixture mainly targets the sulfur moiety of cysteine for oxidation up to irreversible oxidation states, while He/H 2 O treatment leads preferentially to reversible oxidation products. The more O or OH/H 2 O 2 dominated chemistry produced by the two gas admixtures studied offers the possibility to select species for target modification.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization of laser-induced breakdown spectroscopy for liquid sodium analysis

Next-generation nuclear power reactors based on liquid sodium coolant are in development to improve efficiency and safety. Fast breeder reactors could potentially achieve considerably higher fuel burn-up while producing less nuclear waste compared with current commercial technology. Monitoring of impurities in these types of reactors is important in order to prevent blockage of the cooling system or hazardous reactions due to the high reactivity of sodium with water. In this work, laser-induced breakdown spectroscopy is performed on a liquid sodium sample using a custom-built immersion probe system. The probe provides direct line of sight to the sample vessel in argon atmosphere for laser delivery and signal collection. Signatures of sodium, and impurities such as potassium and oxygen have been obtained. The probe height and immersion have a strong influence on the signal level and stability. Argon flow rates of 2 to 5 liters per minute produce no substantial change in signal, suggesting a steady laminar flowing regime. A high signal-to-noise ratio for impurity elements confirms the suitability of this technique for reliable impurity detection and monitoring in the reactor environment.

Gardette, V. [University of Michigan, Ann Arbor, M↗

Partner with a Third-Party Delivery Service or Not? A Prediction-and-Decision Tool for Restaurants Facing Takeout Demand Surges During a Pandemic

Amidst the COVID-19 pandemic, restaurants become more reliant on no-contact pick-up or delivery ways for serving customers. As a result, they need to make tactical planning decisions such as whether to partner with online platforms, to form their own delivery team, or both. In this paper, we develop an integrated prediction-decision model to analyze the profit of combining the two approaches and to decide the needed number of drivers under stochastic demand. We first use the susceptible-infected-recovered (SIR) model to forecast future infected cases in a given region and then construct an autoregressive-moving-average (ARMA) regression model to predict food-ordering demand. Using predicted demand samples, we formulate a stochastic integer program to optimize food delivery plans. We conduct numerical studies using COVID-19 data and food-ordering demand data collected from local restaurants in Nuevo Leon, Mexico, from April to October 2020, to show results for helping restaurants build contingency plans under rapid market changes. Our method can be used under unexpected demand surges, various infection/vaccination status, and demand patterns. Here, our results show that a restaurant can benefit from partnering with third-party delivery platforms when (i) the subscription fee is low, (ii) customers can flexibly decide whether to order from platforms or from restaurants directly, (iii) customers require more efficient delivery, (iv) average delivery distance is long, or (v) demand variance is high.

97 MATHEMATICS AND COMPUTING↗

Changes in SSL Device Efficiency and Optical Performance Under Accelerated Aging Conditions

Lighting application efficiency (LAE) describes the efficient delivery of light from the light source to the lighted task and is viewed as a new frontier—increasing energy savings with solid-state lighting (SSL) technologies. The framework for LAE that is proposed by the U.S. Department of Energy (DOE) consists of four major elements: light source efficiency, optical delivery efficiency, spectral efficiency, and intensity effectiveness. This report focuses on a sampling of the available SSL products that can be broadly defined as having modified spectral output because the method of spectra modification has a significant impact on light source efficiency and long-term optical delivery and spectral efficiencies. This report focused on the changes in light source, optical delivery, and spectral efficiencies that occur during aging of SSL devices. An accelerated stress test (AST) regiment was developed for the devices under test (DUTs) examined in this report to provide insights into how the performance of SSL devices change with aging. The AST protocols demonstrate that the SSL products discussed in this report often reduce light source efficiency to achieve different spectral characteristics. In addition, aging of the optical components (e.g., lenses, solder masks) in SSL devices can produce increased light absorption, which negatively impacts optical delivery efficiency and light source efficiency. The modified spectral outputs of the selected SSL products discussed in this report come in a variety of form factors and achieve enhanced optical performance by using a variety of methods. All of the products examined in this study use mid-power light-emitting diodes (MP-LEDs), although the number, configuration, phosphor content, and light-emitting diode (LED) pump of the MP-LEDs differ. Product MS-1 is a 60-watt (W) replacement A19 lamp with a hermetically sealed glass globe, which contains an embedded optical filter to absorb green and yellow emissions, thereby creating a “sunlike” modified spectrum. Product MS-2 is a 60-W replacement A19 lamp with 30 MP-LEDs, and it uses a violet LED pump, along with green and red phosphor emissions, to produce a “healthy” spectrum. This spectrum omits blue emissions in an effort to reduce melanopic lux. Product MS-3 is an LED module consisting of 21 MP-LEDs that use a violet LED pump, along with blue, green, and red phosphors, to produce a “sunlike” spectrum. Products MS-4 and MS-5 are both 6-inch (in) downlights that use a manual switching mechanism so that users can select application-specific correlated color temperatures before installation. Products MS-4 and MS-5 both contain two LED primaries (2,700 Kelvin [K] and 5,000 K) for spectral tuning. Product MS-4 contains 12 MP-LEDs for each LED primary, and Product MS-5 contains 10 MP-LEDs for each LED primary. This report summarizes the overall findings from up to 8,000 hours (hrs) of AST on the lamp DUTs (Products MS-1 and MS-2); up to 5,000 hrs of AST on the LED light engine DUTs (Product MS-3); and up to 7,000 hrs of AST on the downlight DUTs (Products MS-4 and MS-5). The AST procedures used in this study included a room temperature operational life (RTOL) test, an operational life test conducted at 45 degrees Celsius (°C; 45OL) test, an operational life test conducted at 75°C (75OL), a wet high-temperature operational life test performed at 65°C and 90% relative humidity (6590), and a wet high-temperature operational life test performed at 75°C and 75% relative humidity (7575). The AST procedures used for Products MS-1 and MS-2 were RTOL, 45OL, and 6590. The AST procedures used for Products MS-3, MS-4, and MS-5 were RTOL, 75OL, and 7575. During the ASTs described herein, separate populations of each product (three DUTs in each population for Products MS-1, MS-2, MS-4, and MS-5; four DUTs in each population for Product MS-3) were subjected to power cycling of 1 hr on and 1 hr off. The key findings from this study include the following. Enhanced optical performance came at the cost of reduced light source efficiency for the lamps and light engines examined in this study. The optical filter used to produce a “sunlike” spectrum for Product MS-1 reduced light source efficiency by 26%, from 113 lumens per watt (lm/W) to 85 lm/W. Products MS-2 and MS-3 that used a violet-pumped LED to achieve “healthy” and “sunlike” enhanced optical performance, respectively, suffered the largest reduction in initial light source efficiency (49 lm/W for Product MS-2 and 68 lm/W for Products MS-3) perhaps because of the use of violet LED as the optical pump. Product MS-2 also had the poorest color fidelity because of undersaturation of blues and oversaturation of greens and yellows. Chromaticity maintenance of the products in this study was generally good, with parametric failure only occurring for one product at one AST condition (i.e., Product MS-3 at 7575). The chromaticity shift for Product MS-3 in 7575 test conditions resulted from reduced emissions of the broad green and red phosphors used to mimic sunlight in the 500–750 nanometer (nm) range. As a result of these phosphor emission losses, chromaticity shifted toward the more stable violet-pumped LED and blue phosphor. Although chromaticity maintenance was acceptable for most products tested, different chromaticity shift mechanisms were observed for temperature and humidity tests compared with temperature alone for Products MS-1, MS-2, and MS-3. For Product MS-1, a relative increase in green emissions was observed with humidity, which may indicate humidity-accelerated degradation of the optical filter at green wavelengths (optical delivery efficiency reduction) or degradation of the emitters in the red region (spectral efficiency reduction). The violet-pumped products (i.e., MS-2 and MS-3) exhibited different chromaticity shift behavior in the temperature-humidity environments, with Product MS-2 shifting generally yellow because of photo-induced oxidation of the plastic globe (i.e., a reduction of optical delivery efficiency) and Product MS-3 shifting toward violet and blue emitters because of faster loss of emission from green and red phosphors (i.e., a reduction in spectral efficiency). Because of an initial drop in power consumption, the light source efficiency of downlights (Products MS-4 and MS-5) increased at RTOL throughout the test duration. The light source efficiency initially increased during 75OL until a decay in luminous flux maintenance (LFM) dominated light source efficiency, whereas the light source efficiency decreased for the entire 7575 test duration. It was found that increasing the ambient environment of an SSL device from 25°C to 75°C decreases the LFM by 2.7 to 5.5, depending on design of the SSL device. Adding humidity to the system (75OL to 7575) was found to decrease LFM by another factor of approximately 3.0. A common location of failure was identified for the downlights (Products MS-4 and MS-5) operated in the 7575 environment. This failure abruptly occurred between 3,000 to 5,000 hrs of testing on the film capacitor of the electromagnetic interference (EMI) filter near the diode bridge for 11 of the 12 downlights. It is likely that this failure was caused by a combination of the high electrical voltage across the capacitor, the location of the capacitor near the heat sources (e.g., transformers, diode bridges, power resistors), and the high stress environment of 7575. Longer test times are needed to fully understand the LFM, luminous efficacy changes, and chromaticity shifts for some of the products. Because of the high reliability, light source efficiency, and spectral tuning capabilities of LEDs, the expectations of LAE for SSL products are greatly increased over traditional lighting products. The data gathered in this report begin to provide an understanding of the tradeoffs that current SSL products undergo when optimizing the different efficiency elements of LAE. As discussed in this report, the findings from the tests conducted show that the optimization of spectral efficiency can come at the cost of initial light source efficiency. Furthermore, the introduction of violet LEDs can promote long-term optical delivery efficiency degradation, and the introduction of optical filters or new phosphors can lead to unwanted spectral efficiency changes because the ratio of phosphor emitters changes with aging. The data presented in this report also identified a common failure location in 6-in downlights. The results regarding long-term behavior of the modified spectra devices studied provide valuable information about changes to the light source, spectral, and optical delivery efficiencies as the devices age. This information can be used to improve future SSL designs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A holistic approach to the optimization of neutron beam transport at the LANSCE facility

An advanced neutron beam collimation system has been developed as part of an effort to optimize neutron beam transport at the Weapons Neutron Research (WNR) Facility, located within the Los Alamos Neutron Science Center (LANSCE). The goal of this work was to develop and demonstrate techniques to tailor neutron delivery in order to provide maximum available flux on sample with a specific beam profile, while simultaneously reducing unwanted background. A holistic approach was taken, upgrading the facility spallation target, facility metrology infrastructure, and flight path shutter insert to support the implementation of this advanced collimation system. Here, modern instruments and software were employed to conduct facility surveys, characterization of as-built geometry of critical components, 3D ray tracing and neutron transport calculations. Beam images and flux measurements were acquired after installation to evaluate the performance of the collimation system and to demonstrate consistent agreement with MCNP simulations which showed an 87% increase of flux on sample while providing suppression of background neutron impingement on the sample frame by 10 3 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integration and Demonstration of Monitoring, Modeling, and Prediction of DV-1 Amendment Performance at the Bench Scale: DV-1 Amendment Demonstration

During fiscal years 2024 and 2025, the U.S. Department of Energy’s Hanford Field Office commissioned Pacific Northwest National Laboratory to conduct applied research aimed at reducing the cost, time, and uncertainty associated with in situ treatment of vadose zone contaminants at the Hanford Site. This report outlines the integration of three key research efforts into a meso-scale demonstration designed to advance field-scale solutions that aim to (1) optimize the delivery of chemical amendments to contaminated soils, (2) reduce uncertainty in amendment delivery performance assessment using advanced monitoring techniques, and (3) provide real-time insights into when and where amendment-induced precipitation reactions occur in the subsurface. To achieve these objectives, the tank-scale (~ 1 cubic meter) Geophysical Imaging of Flow and Transport (GIFT) system was developed. GIFT enables experimental testing of amendment delivery while incorporating automated multi-modal monitoring approaches, including pressure measurements, direct fluid sampling, and remote time-lapse geophysical imaging. The data generated from these monitoring techniques will serve as inputs for a generative artificial-intelligence-driven digital twin – a numerical simulation model designed to honor observed data while quantifying uncertainty in simulation accuracy. Using this simulator, researchers will refine an amendment injection strategy to maximize delivery efficiency within a low-permeability soil zone. Monitoring data will be interpreted through simulated outputs to enhance understanding of the injection process. The efficacy of this integrated approach will be evaluated through direct sampling at the conclusion of the experiment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Hanford 200 West Area Tank Farms (241-S/241-SX-/241-U tank farms) Physical Properties Data for Use in Development of West Area Tank Treatment (WATT) Processing

With the recent acceptance of West Area Tank Treatment disposition alternative for 200 West Area tanks at the Hanford Site by the State of Washington and the U.S. Department of Energy, a review was initiated to identify the physical properties data available in the literature for the Hanford 241-S, 241-SX, and 241-U tank farms. The literature reviewed indicated that there is a relatively small set of useful data on physical properties of 200 West Area tanks, and the data that do exist are biased around a narrow range of tank samples. Much of the testing between the 1990s and mid-2010s was intended to support either enhanced sludge washing or feed delivery to the Pretreatment Facility at the Hanford Waste Treatment and Immobilization Plant. As such, some physical properties of 200 West Area samples were measured under conditions that are no longer relevant. Because of the distinctly different nature of many past processes at the 200 West Area compared to the 200 East Area, insight from waste testing in the 200 East Area waste should be used with caution, as there may be significantly different qualities in the physical properties data between these two areas (both in situ and as measured in laboratory analyses). Based on this assessment, there is a need to collect additional physical property data to support planning for 200 West Area retrievals.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗