Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A Comparative Study of Single-pulse and Double-pulse Laser-Induced Breakdown Spectroscopy with Uranium-containing Samples

Laser-induced breakdown spectroscopy (LIBS) holds potential advantages in special nuclear material (SNM) sensing and nuclear forensics which require rapid analysis, minimal sample preparation and stand-off distance capability. SNM, such as U, however, result in crowded emission spectra with LIBS, and characteristic emission lines are challenging to discern. It is well-known that double-pulse LIBS (DPLIBS) improves the signal intensity for analytes over conventional single-pulse LIBS (SPLIBS). This study investigates U signal in a glass matrix using DPLIBS and compares to signal features obtained using SPLIBS. DPLIBS involves sequential firing of 1.06 µm Nd:YAG pre-pulse and 10.6 µm TEA CO2 heating pulse in near collinear geometry. Optimization of experimental parameters including inter-pulse delay and energy follows identification of characteristic lines and signals for bulk analyte Ca and minor constituent analyte U for both DPLIBS and SPLIBS. Spatial and temporal coupling of the two pulses in the proposed DPLIBS technique yields improvements in analytical merits with negligible further damage to the sample compared to SPLIBS. Subsequently, the study discusses optimum plasma emission conditions of U lines and relative figures of merit in both SPLIBS and DPLIBS. Investigation into plasma characteristics also addresses plausible mechanisms related to observed U analyte signal variation between SPLIBS and DPLIBS.

Skrodzki, P. J.↗

Plug-and-Play Priors for Bright Field Electron Tomography and Sparse Interpolation

Many material and biological samples in scientific imaging are characterized by nonlocal repeating structures. These are studied using scanning electron microscopy and electron tomography. Sparse sampling of individual pixels in a two-dimensional image acquisition geometry, or sparse sampling of projection images with large tilt increments in a tomography experiment, can enable high speed data acquisition and minimize sample damage caused by the electron beam. In this paper, we present an algorithm for electron tomographic reconstruction and sparse image interpolation that exploits the nonlocal redundancy in images. We adapt a framework, termed plug-and-play priors, to solve these imaging problems in a regularized inversion setting. The power of the plug-and-play approach is that it allows a wide array of modern denoising algorithms to be used as a “prior model” for tomography and image interpolation. We also present sufficient mathematical conditions that ensure convergence of the plug-and-play approach, and we use these insights to design a new nonlocal means denoising algorithm. Finally, we demonstrate that the algorithm produces higher quality reconstructions on both simulated and real electron microscope data, along with improved convergence properties compared to other methods.

47 OTHER INSTRUMENTATION↗

Direct Analysis of Organic Compounds in Liquid Using a Miniature Photoionization Ion Trap Mass Spectrometer with Pulsed Carrier-Gas Capillary Inlet

A miniature ion trap mass spectrometer with capillary direct sampling and vacuum ultraviolet photoionization source was developed to conduct trace analysis of organic compounds in liquids. Self-aspiration sampling is available where the samples are drawn into the vacuum chamber through a capillary with an extremely low flow rate (less than 1 μL/min), which minimizes sample consumption in each analysis to tens of micrograms. A pulsed gas-assisted inlet was designed and optimized to promote sample transmission in the tube and facilitate the cooling of ions, thereby improving instrument sensitivity. A limit of detection of 2 ppb could be achieved for 2,4-dimethylaniline in a methanol solution. The sampling system described in the present study is specifically suitable for a miniature photoionization ion trap mass spectrometer that can perform rapid and online analysis for liquid samples. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray photon-in/photon-out methods for chemical imaging

Most interesting materials in nature are heterogeneous, so it is useful to have analytical techniques with spatial resolution sufficient to resolve these heterogeneities.This article presents the basics of X-ray photon-in/photon-out chemical imaging. This family of methods allows one to derive images reflectingthe chemical state of a given element in a complex sample, at micron or deep sub-micron scale. X-ray chemical imaging is relatively non-destructiveand element-selective, and requires minimal sample preparation. The article presents the basic concepts and some considerations of data takingand data analysis, along with some examples.

47 OTHER INSTRUMENTATION↗

Atmospheric Solids Analysis Probe Mass Spectrometry: A New Approach for Airborne Particle Analysis

Secondary organic aerosols (SOA) formed in the atmosphere from the condensation of semivolatile oxidation products are a significant component of airborne particles which have deleterious effects on health, visibility, and climate. In this study, atmospheric solids analysis probe mass spectrometry (ASAP-MS) is applied for the first time to the identification of organics in particles from laboratory systems as well as from ambient air. SOA were generated in the laboratory from the ozonolysis of r-pinene and isoprene, as well as from NO3 oxidation of r-pinene, and ambient air was sampled at forested and suburban sites. Particles were collected by impaction on ZnSe disks, analyzed by Fourier transform-infrared spectroscopy (FT-IR) and then transferred to an ASAP-MS probe for further analysis. ASAP-MS data for the laboratory-generated samples show peaks from wellknown products of these reactions, and higher molecular weight oligomers are present in both laboratory and ambient samples. Oligomeric products are shown to be present in the NO3 reaction products for the first time. A major advantage of this technique is that minimal sample preparation is required, and complementary information from nondestructive techniques such as FT-IR can be obtained on the same samples. In addition, a dedicated instrument is not required for particle analysis. This work establishes that ASAP-MS will be useful for identification of organic components of SOA in a variety of field and laboratory studies.

Environmental Molecular Sciences Laboratory↗

Computing the partition function, ensemble averages, and density of states for lattice spin systems by sampling the mean

An algorithm to approximately calculate the partition function (and subsequently ensemble averages) and density of states of lattice spin systems through non-Monte-Carlo random sampling is developed. This algorithm (called the sampling-the-mean algorithm) can be applied to models where the up or down spins at lattice nodes interact to change the spin states of other lattice nodes, especially non-Ising-like models with long-range interactions such as the biological model considered here. Because it is based on the Central Limit Theorem of probability, the sampling-the-mean algorithm also gives estimates of the error in the partition function, ensemble averages, and density of states. Easily implemented parallelization strategies and error minimizing sampling strategies are discussed. The sampling-the-mean method works especially well for relatively small systems, systems with a density of energy states that contains sharp spikes or oscillations, or systems with little a priori knowledge of the density of states.

97 MATHEMATICS AND COMPUTING↗

Selenium Metabolism in Cancer Cells: The Combined Application of XAS and XFM Techniques to the Problem of Selenium Speciation in Biological Systems

Determining the speciation of selenium in vivo is crucial to understanding the biological activity of this essential element, which is a popular dietary supplement due to its anti-cancer properties. Hyphenated techniques that combine separation and detection methods are traditionally and effectively used in selenium speciation analysis, but require extensive sample preparation that may affect speciation. Synchrotron-based X-ray absorption and fluorescence techniques offer an alternative approach to selenium speciation analysis that requires minimal sample preparation. We present a brief summary of some key HPLC-ICP-MS and ESI-MS/MS studies of the speciation of selenium in cells and rat tissues. We review the results of a top-down approach to selenium speciation in human lung cancer cells that aims to link the speciation and distribution of selenium to its biological activity using a combination of X-ray absorption spectroscopy (XAS) and X-ray fluorescence microscopy (XFM). The results of this approach highlight the distinct fates of selenomethionine, methylselenocysteine and selenite in terms of their speciation and distribution within cells: organic selenium metabolites were widely distributed throughout the cells, whereas inorganic selenium metabolites were compartmentalized and associated with copper. New data from the XFM mapping of electrophoretically-separated cell lysates show the distribution of selenium in the proteins of selenomethionine-treated cells. Future applications of this top-down approach are discussed.

60 APPLIED LIFE SCIENCES↗

Understanding the limitations and potential of micro tensile testing of tungsten and needs for crystal plasticity modelling

Tungsten is the leading plasma facing material candidate due to its exceptional properties. Understanding the response to neutron irradiation is crucial for the lifetime evaluation of tungsten. The limited space in nuclear reactors and the high levels of radioactivity of the specimens after irradiation are significant barriers to accurately measuring the mechanical properties after neutron irradiation. Testing of micro tensile specimens is one approach to reduce the total amount of irradiated material needed for a set of mechanical testing experiments. However, micro samples are not necessarily measuring the bulk material properties, as size effects produce higher measured mechanical properties than is observed in engineering size counterparts. Determining the minimal sample size for reliable bulk property measurement, combined with modeling efforts, is essential. We conducted room temperature tensile tests on tungsten micro tensile specimens fabricated with focused ion beam, plasma focused ion beam and femto-second laser ablation system to dimension of 2×2×7?µm³, 7×7×18?µm³, and 80×100×233?µm³ (width×thickness×gauge-length), respectively. Elevated tensile testing was performed up to 475°C on 5×5×18?µm³ specimens fabricated with focused ion beam. The smallest specimens exhibited a high degree of ductility and strength, whereas the largest specimens demonstrated behavior akin to bulk tungsten. To investigate the effects introduced by the micro specimen fabrication processes and to obtain the necessary bulk dislocation density for the crystal plasticity model, we employed X-ray diffraction depth profiling. This measurement was performed using different X-ray sources with varying penetration depths. Finally, the potential and limitations of micro mechanical tests for tungsten will be discussed.

36 - MATERIALS SCIENCE↗

Multispecies Biofilms Transform Selenium Oxyanions into Elemental Selenium Particles: Studies Using Combined Synchrotron X-ray Fluorescence Imaging and Scanning Transmission X-ray Microscopy

Selenium (Se) is an element of growing environmental concern, because low aqueous concentrations can lead to biomagnification through the aquatic food web. Biofilms, naturally occurring microbial consortia, play numerous important roles in the environment, especially in biogeochemical cycling of toxic elements in aquatic systems. The complexity of naturally forming multispecies biofilms presents challenges for characterization because conventional microscopic techniques require chemical and physical modifications of the sample. Here, multispecies biofilms biotransforming selenium oxyanions were characterized using X-ray fluorescence imaging (XFI) and scanning transmission X-ray microscopy (STXM). These complementary synchrotron techniques required minimal sample preparation and were applied correlatively to the same biofilm areas. Sub-micrometer XFI showed distributions of Se and endogenous metals, while Se K-edge X-ray absorption spectroscopy indicated the presence of elemental Se (Se0). Nanoscale carbon K-edge STXM revealed the distributions of microbial cells, extracellular polymeric substances (EPS), and lipids using the protein, saccharide, and lipid signatures, respectively, together with highly localized Se0 using the Se LIII edge. Transmission electron microscopy showed the electron-dense particle diameter to be 50–700 nm, suggesting Se0 nanoparticles. The intimate association of Se0 particles with protein and polysaccharide biofilm components has implications for the bioavailability of selenium in the environment.

Yang, Soo In↗

Centrifugal Microfluidic Platform for Rapid, Multiplexed Detection of TB and HIV Biomarkers in Whole Blood Samples

Infection with Mycobacterium Tuberculosis represents a significant threat to people with immune disorders, such as HIV-positive individuals, and can result in significant health complications or death if not diagnosed and treated early. We present a centrifugal microfluidic platform for multiplexed detection of tuberculosis and HIV biomarkers in human whole blood with minimal sample preparation and a sample-to-answer time of 30 minutes. This multiplexed assay was developed for the detection of two M.tuberculosis secreted proteins, whose secretion represents an active and ongoing infection, as well as detection of HIV p24 protein and human anti-p24 antibodies. The limit of detection for this multiplex assay is in the pg/mL range for both HIV and M.tuberculosis proteins, making this assay potentially useful in the clinical diagnosis of both HIV and Tuberculosis proteins indicative of active infection. Antigen detection for the HIV assay sensitivity was 89%, the specificity 85%. Serological detection had 100% sensitivity and specificity for the limited sample pool. The centrifugal microfluidic platform presented here offers the potential for a portable, fast and inexpensive multiplexed diagnostic device that can be used in resource-limited settings for diagnosis of TB and HIV.

60 APPLIED LIFE SCIENCES↗

Adaptable SEC‐SAXS data collection for higher quality structure analysis in solution

Abstract The two major challenges in synchrotron size‐exclusion chromatography coupled in‐line with small‐angle x‐ray scattering (SEC‐SAXS) experiments are the overlapping peaks in the elution profile and the fouling of radiation‐damaged materials on the walls of the sample cell. In recent years, many post‐experimental analyses techniques have been developed and applied to extract scattering profiles from these problematic SEC‐SAXS data. Here, we present three modes of data collection at the BioSAXS Beamline 4–2 of the Stanford Synchrotron Radiation Lightsource (SSRL BL4‐2). The first mode, the High‐Resolution mode, enables SEC‐SAXS data collection with excellent sample separation and virtually no additional peak broadening from the UHPLC UV detector to the x‐ray position by taking advantage of the low system dispersion of the UHPLC. The small bed volume of the analytical SEC column minimizes sample dilution in the column and facilitates data collection at higher sample concentrations with excellent sample economy equal to or even less than that of the conventional equilibrium SAXS method. Radiation damage problems during SEC‐SAXS data collection are evaded by additional cleaning of the sample cell after buffer data collection and avoidance of unnecessary exposures through the use of the x‐ray shutter control options, allowing sample data collection with a clean sample cell. Therefore, accurate background subtraction can be performed at a level equivalent to the conventional equilibrium SAXS method without requiring baseline correction, thereby leading to more reliable downstream structural analysis and quicker access to new science. The two other data collection modes, the High‐Throughput mode and the Co‐Flow mode, add agility to the planning and execution of experiments to efficiently achieve the user's scientific objectives at the SSRL BL4‐2.

Matsui, Tsutomu↗

In Vitro Evolution and Computational Approaches to Predict, Prevent and Control Future Pandemics

The natural tendency of virus to mutate and the under-sampling of the environment makes it difficult to become aware of the emergence of new viral strains with pandemic potential. Being able to predict what mutations make a virus more infective might allow to spot such strains with minimal sampling and potentially allow to predict/prevent the next pandemic. The team attempted to mimic natural viral mutations and recombination through computational and experimental methods producing a variety of mutants of a SARS-COV-2 protein (receptor binding domain, RBD, of spike protein) responsible for viral entry in mammalian cells. The library of mutants was then interrogated for ability and lack-there-of to interact with the host cell receptor ushering viral entry, Angiotensin-converting enzyme 2 (ACE2). The negative and positive data set is intended to “teach the rules” of virus-host receptor interaction. Additionally, the positive clones were used to screen a set of antibody mutants designed to widen the breadth of viral mutants recognition, to demonstrate that this kind of libraries could also be a tool to produce antibody therapeutics impervious to viral mutation, even before a pandemic strain is discovered.

59 BASIC BIOLOGICAL SCIENCES↗

High-Throughput Characterization and Optimization of Polyamide Hydrolase Activity Using Open Port Sampling Interface Mass Spectrometry

Enzymatic biodegradation of polymers, such as polyamides (PA), has the potential to cost-effectively reduce plastic waste, but enhancements in degradation efficiency are needed. Engineering enzymes through directed evolution is one pathway toward identification of critical domains needed for improving activity. However, screening such enzymatic libraries (100s-to-1000s of samples) is time-consuming. Here we demonstrate the use of robotic autosampler (PAL) and immediate drop on demand technology (I.DOT) liquid handling systems coupled with open-port sampling interface-mass spectrometry (OPSI-MS) to screen for PA6 and PA66 hydrolysis by 6-aminohexanoate-oligomer endo-hydrolase (nylon hydrolase, NylC) in a high-throughput (8–20 s/sample) manner. The OPSI-MS technique required minimal sample preparation and was amenable to 96-well plate formats for automated processing. Enzymatic hydrolysis of PA characteristically produced soluble linear oligomer products that could be identified by OPSI-MS. Incubation temperatures and times were optimized for PA6 (65 °C, 24 h) and PA66 (75 °C, 24 h) over 108 experiments. In addition, the I.DOT/OPSI-MS quantified production of PA6 linear dimer (8.3 ± 1.6 μg/mL) and PA66 linear monomer (13.5 ± 1.5 μg/mL) by NylC with a lower limit of detection of 0.029 and 0.032 μg/mL, respectively. For PA6 and PA66, linear oligomer production corresponded to 0.096 ± 0.018% and 0.204 ± 0.028% conversion of dry pellet mass, respectively. The developed methodology is expected to be utilized to assess enzymatic hydrolysis of engineered enzyme libraries, comprising hundreds to thousands of individual samples.

47 OTHER INSTRUMENTATION↗

Membrane insertion for the detection of lipopolysaccharides: Exploring the dynamics of amphiphile-in-lipid assays

Shiga toxin-producing Escherichia coli is an important cause of foodborne illness, with cases attributable to beef, fresh produce and other sources. Many serotypes of the pathogen cause disease, and differentiating one serotype from another requires specific identification of the O antigen located on the lipopolysaccharide (LPS) molecule. The amphiphilic structure of LPS poses a challenge when using classical detection methods, which do not take into account its lipoglycan biochemistry. Typically, detection of LPS requires heat or chemical treatment of samples and relies on bioactivity assays for the conserved lipid A portion of the molecule. Our goal was to develop assays to facilitate the direct and discriminative detection of the entire LPS molecule and its O antigen in complex matrices using minimal sample processing. To perform serogroup identification of LPS, we used a method called membrane insertion on a waveguide biosensor, and tested three serogroups of LPS. The membrane insertion technique allows for the hydrophobic association of LPS with a lipid bilayer, where the exposed O antigen can be targeted for specific detection. Samples of beef lysate were spiked with LPS to perform O antigen specific detection of LPS from E. coli O157. To validate assay performance, we evaluated the biophysical interactions of LPS with lipid bilayers both in- and outside of a flow cell using fluorescence microscopy and fluorescently doped lipids. Our results indicate that membrane insertion allows for the qualitative and reliable identification of amphiphilic LPS in complex samples like beef homogenates. In addition, we also demonstrated that LPS-induced hole formation does not occur under the conditions of the membrane insertion assays. Together, these findings describe for the first time the serogroup-specific detection of amphiphilic LPS in complex samples using a membrane insertion assay, and highlight the importance of LPS molecular conformations in detection architectures.

59 BASIC BIOLOGICAL SCIENCES↗

Imaging the presence of silane coatings in concrete with micro X-ray fluorescence

Silane is a commonly used surface treatment to reduce fluid entry into the concrete matrix. This work uses micro X-ray fluorescence (μXRF) to image the presence of silane coatings in field samples and the changes made to the paste chemistry. There are many advantages that μXRF has over other imaging techniques due to the large spot size and the high energy levels. Because of this, μXRF can rapidly investigate large areas and requires minimal sample preparation. Quantitative measurements are made to show that there is a reduction in the amount of sulfur and an increase in potassium in the hydrophobic regions formed by silane coatings. These measurements provide important insights into modifications made to the concrete matrix when silane sealers are used. The mechanisms for the observed chemistry changes are discussed and a simple field or laboratory test method is presented that uses a dye to detect silane coatings.

36 MATERIALS SCIENCE↗

2D/3D cryo x-ray fluorescence imaging at the bionanoprobe at the advanced photon source

Trace elements, particularly metals, play very important roles in biological systems. Synchrotron-based hard X-ray fluorescence microscopy offers the most suitable capabilities to quantitatively study trace metals in thick biological samples, such as whole cells and tissues. In this manuscript, we have demonstrated X-ray fluorescence imaging of frozen-hydrated whole cells using the recent developed Bionanoprobe (BNP). The BNP provides spatial resolution down to 30 nm and cryogenic capabilities. Frozen-hydrated biological cells have been directly examined on a sub-cellular level at liquid nitrogen temperatures with minimal sample preparation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of a suitable molar absorption coefficient (ε) for lignin analysis of fibrous plants using the CASA method

In this study, the benchmarking and applicability of the CASA method for the analysis of fibrous plants, such as flax, hemp, and jute, is evaluated. Lignin is a phenolic biopolymer present in plant cell walls and is composed of three primary monomeric units, designated G, S, and H. Various factors, such as the genetic variability, influence the relative proportions of these units in plant samples. Recently, the cysteine-assisted sulfuric acid (CASA) method has been introduced as a rapid method for the quantification of lignin in wood samples. The aim of this study is to establish a suitable molar absorption coefficient (ε, L·g –1 ·cm –1 ) to adapt the CASA method for use with annual plant fibers. This investigation was motivated by the technical advantages of the CASA method, including higher throughput, lower reaction temperatures, and ecological benefits due to the absence of carcinogenic, mutagenic, or reprotoxic (CMR) substances and the need for minimal sample quantities. In this method, lignin solubilization is facilitated by cysteine, which is an amino acid that enhances the reaction kinetics, using a one-hour incubation period. However, as with any spectrophotometric technique, the CASA method depends on a molar absorption coefficient (ε) that varies according to the ratio of the aromatic units within the polymer. To evaluate the suitability of CASA for quantifying lignin in economically significant plant fibers, we investigate the impact of the unit ratios on the accuracy of ε. The results are compared with those of two widely recognized lignin analytical methods: the Klason method, which is a gravimetric reference method, and the acetyl bromide soluble lignin method, which is the most commonly used spectrophotometric approach. The final ε obtained in this study reveals a relative difference in lignin content ranging from –8 % to +9 % based on a comparison between the CASA and Klason methods across different industrial hemp varieties. As a result, using known G:S ratios in annual fibrous plants, ε can be estimated from our results.

59 BASIC BIOLOGICAL SCIENCES↗

The Integrated Impact of Diet on Human Immune Response, the Gut Microbiota, and Nutritional Status During Adaptation to Spaceflight

Long-duration spaceflight impacts human physiology, including well documented immune system dysregulation. Diet, the microbiome, and immune system function are interlinked, but diet is the only one of these factors that we have the ability to easily, and significantly, alter on Earth or during flight. As we better understand dietary impacts on physiology, we may then improve the spaceflight diet to improve crew health and potentially reduce spaceflight-associated physiological decrements. Increasing the consumption of fruits and vegetables and bioactive compounds (e.g., omega-3 fatty acids, lycopene, flavonoids) and therefore enhancing overall nutritional intake from the nominal shelf-stable, fully-processed, space food system is expected to serve as a countermeasure to detrimental impacts to human physiology, including dysregulation in immunological profiles, the taxonomic profile of the gut microbiota, and nutritional status during spaceflight. In this study, first we sought to determine the effect of the nominal shelf-stable spaceflight diet compared to an "enhanced" shelf-stable spaceflight diet on human biochemistry, immunology, and the microbiome in a ground-based, simulated space mission. The ground analog portion of this study was conducted in the NASA Human Exploration Research Analog (HERA) Campaign 4 missions, which consisted of four 45-day missions with closed chamber confinement and realistic mission simulation to study effects on crew health and performance. As reported previously, analyses indicate beneficial associations between diet and markers of nutritional status, stress, the microbiome, and cognitive performance. Intake and beneficial associations varied by subject. This data will be used as a ground-based control for spaceflight, where the spaceflight environment (e.g., radiation, microgravity) will have additional impacts and the potential to evaluate effects of the diet will be greater. The second phase of this study is to occur on the International Space Station, where it is currently being implemented. The test plan is similar to that used in the HERA missions. The enhanced diet is intended to provide 25% of the crews’ diet with foods rich in omega-3 fatty acids, lycopene, and flavonoids, along with more fruits and vegetables in general (the other 75% of the diet will be obtained from standard and crew preference items available on the ISS). Biological samples (blood, urine, stool, and saliva) are being collected from participants at selected time points before, during, and after the mission. Data collection also includes dietary intake recording and body mass measurement. Currently, 6 of 9 planned astronauts have completed data collection. Analysis of immune markers, latent herpes virus reactivation, the taxonomic and metatranscriptomic profile of the gut microbiome, and nutritional status biomarkers and biochemical metabolites will occur in batch to minimize sample handling variations. Mixed models statistical analyses will be used, incorporating random effects to account for repeated measures within individuals to assess the impact of diet on physiological outcomes. We expect this study to provide evidence of beneficial impact of this enhanced diet on crew health and adaptation to spaceflight. These data will aid in evidence-based mass-risk trades for food system design and development of targeted dietary interventions for future exploration-class space missions.

Grace L. Douglas↗