Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample sealing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Self-sealing container for protecting air sensitive samples

A self-sealing container, used for transferring one or more air sensitive samples between vacuum systems, includes a housing with a cavity that holds the sample(s), and a lid disposed on top of the housing. The lid is configured to interface with the housing to form a seal over the cavity when the lid is closed. At least two flexure systems, each coupled to the housing and the lid, are disposed on opposing sides of the housing. The flexure systems apply forces to the lid that move the lid horizontally and vertically above the housing, into an open position. A pneumatic actuator, movably coupled to the housing and the lid, that is actuated by a change in ambient pressure. When actuated, it applies forces that move the lid horizontally and vertically to the closed position, in opposition to and in excess of the forces applied by the flexure systems.

42 ENGINEERING↗

Sealing and External Sterilization of a Sample Container

A method of (1) sealing a sample of material acquired in a possibly b iologically contaminated ("dirty") environment into a hermetic conta iner, (2) sterilizing the outer surface of the container, then (3) d elivering the sealed container to a clean environment has been propos ed. The method now proposed was originally intended to be used to ret urn samples from Mars to Earth, but could also be used on Earth to t ransport material samples acquired in environments that contain biol ogical hazards and/or, in some cases, chemical hazards.

Bar-Cohen, Yoseph↗

Sealing Station Mechanisms for the Mars 2020 Rover Sample Caching Subsystem

The Sealing Station is composed of two mechanisms: the Gripper Mechanism, for orientation and support of the Sample Tube during the Hermetic Seal activation activity, as well as ejecting Sample Tubes out of the Rover, and the Ram Mechanism, which produces and applies a high force for seal activation. The Ram Mechanism is a compact high force linear actuator that uses a planetary roller screw (PRS) as the output linear stage, tapered roller bearings (TRB) to support the PRS at the high loads, a set of spur gears supported by cylinder roller bearings, and a brushless motor with a planetary gearhead and magnetic detent brake. This paper describes the role of these mechanisms in the Mars 2020 Rover mission as a part of the Sample Caching Subsystem (SCS) and Adaptive Caching Assembly (ACA) and their interactions with the Hermetic Seal and Sample Tube hardware. We report on development testing performed with the PRS that show it has capability of supporting cross-moment loads, something manufacturers of these components do not rate. Also discussed is the interaction of the passive holding torque from magnetic detent brakes and hardstop preload, setting of a very light preload in the TRB, and the complex linear dyno test equipment used, and how that testing could have been improved.

Grimes-York, Jesse↗

Sample Caching Subsystem

A paper describes the Sample Caching Subsystem (SCS), a method for storing planetary core and soil samples in a container that seals the samples away from the environment to protect the integrity of the samples and any organics they might contain. This process places samples in individual sleeves that are sealed within a container for use by either the current mission or by following missions. A sample container is stored with its sleeves partially inserted. When a sample is ready to be contained, a transfer arm rotates over and grasps a sleeve, pulls it out of the container from below, rotates over and inserts the sleeve into a funnel where it is passively locked into place and then released from the arm. An external sampling tool deposits the sample into the sleeve, which is aligned with the tool via passive compliance of the funnel. After the sampling tool leaves the funnel, the arm retrieves the sleeve and inserts it all the way into the sample container. This action engages the seal. Full containers can be left behind for pick-up by subsequent science missions, and container dimensions are compatible for placement in a Mars Ascent Vehicle for later return to Earth.

Backes, Paul G.↗

MSR Science Planning Group 2 (MSPG2): Science & Curation Considerations for Time Sensitive Measurements That Should be Performed in Containment

The Perseverance rover is currently collecting samples on the martian surface for potential return to Earth and planning is underway to develop facilities to study these samples. Perseverance will collect up to 38 samples that will be sealed in TiN tubes. As long as the tubes remain sealed the samples will be metastable. However, as soon as a tube is opened, or headspace gas is extracted these samples will begin to re-equilibrate with their new surroundings. The MSPG2 time-sensitive science sub-group attempted to quantify the rates at which alteration is likely to occur assuming the samples are opened and stored in a nitrogen atmosphere at room temperature. The group also recommended ~20 instruments for inclusion in a sample receiving facility to allow the time sensitive properties of these samples to be measured before they are irreversibly altered.

Aaron B Regberg↗

Use of Guided Acoustic Waves to Assess the Effects of Thermal-Mechanical Cycling on Composite Stiffness

The introduction of new, advanced composite materials into aviation systems requires it thorough understanding of the long-term effects of combined thermal and mechanical loading. As part of a study to evaluate the effects of thermal-mechanical cycling, it guided acoustic (Lamb) wave measurement system was used to measure the bending and out-of-plane stiffness coefficients of composite laminates undergoing thermal-mechanical loading. The system uses a pulse/receive technique that excites an antisymmetric Lamb mode and measures the time-of-flight over a wide frequency range. Given the material density and plate thickness, the bending and out-of-plane shear stiffnesses are calculated from a reconstruction of the velocity dispersion curve. A series of 16 and 32-ply composite laminates were subjected to it thermal-mechanical loading profile in load frames equipped with special environmental chambers. The composite systems studied were it graphite fiber reinforced amorphous thermoplastic polyimide and it graphite fiber reinforced bismaleimide thermoset. The samples were exposed to both high and low temperature extremes its well as high and low strain profiles. The bending and out-of-plane stiffnesses for composite sample that have undergone over 6,000 cycles of thermal-mechanical loading are reported. The Lamb wave generated elastic stiffness results have shown decreases of up to 20% at 4,936 loading cycles for the graphite/thermoplastic samples and up to 64% at 4,706 loading cycles for the graphite/thermoset samples.

Seale, Michael D.↗

Modelling and Laboratory Testing of Particle Resuspension and Transport for the Assessment of Terrestrial-Borne Biological Contamination of the Samples on the Mars 2020 Mission

The Mars 2020 mission will land a rover on the surface of Mars that will acquire, encapsulate, and cache scientifically selected samples of martian material for possible return to Earth by a future mission. The samples will be individually encapsulated and sealed in sample tubes. Each sample, and therefore each sample tube, must be kept clean of viable organisms with a terrestrial origin, which may adhere to the rover on their own and/or on other non-biological particles. Therefore, contrary to previous missions to the Red Planet, Mars 2020 is subject to new and more stringent biological, organic and inorganic contamination requirements. This paper reports on the analyses and testing performed to assess the various vectors that can lead to the terrestrial-borne contamination of the samples, focusing on those that are predicted to be the larger contributors. Specifically, the contamination of the sample tubes is expected to be very small prior to the commencement of the mission’s science phase since these tubes are protected by so-called Fluid Mechanical Particle Barriers. Once on the surface of Mars however the sample tubes will be removed from their FMPBs and be subject to contamination from the rover. Of specific interest is the vector by which winds dislodge some particles from the surface of the rover and transport them to the surrounding soil. Naturally, such assessments require multi-disciplinary analyses involving at minimum the physics of particle adhesion and resuspension from surfaces, fluid mechanics and aerosols. Here we provide an overview of these models. We also report on particle resuspension experiments we have performed at the Jet Propulsion Laboratory to both guide and validate the aforementioned physics models.

Steltzner, Adam↗

Initial Petrographic Analysis of Apollo 17 73002 Continuous Core Thin Sections Using QEMSCAN Mapping Techniques

In 1972, the Apollo 17 mission landed in the Taurus-Littrow Valley located in the southeastern edge of Mare Serenitatis [1].During EVA 2at Station 3,a double drive tube was used to collect a sealed core sample (73001/2)of the upper~70cm of the lunar regolith[2-4].The core was taken from the surface of the light mantle deposit, found at the base of the South Massif [3]. For nearly 50 years, the sealed core samples have remained unopened. This study is part of the Apollo Next Generation Sample Analysis (ANGSA) initiative to analyze the continuous thin sections from the Apollo 17 drive tubes opened in 2019[5-7].

QEMSCAN↗

Numerical Modelling of Sublimation Losses During Sample Handling Within the Light WAVE Lunar Water Prospecting Instrument

NASA’s focus of exploring the Moon’s south pole under the Artemis program has placed new emphasis on characterizing the quantity and distribution of water ice and other volatiles present within the Moon’s permanently shadowed regions (PSRs), first measured during the 2009 LCROSS mission. NASA’s VIPER rover is the first of a series of prospecting missions to characterize this water ice resource. NASA’s Johnson Space Center (JSC) has developed the Light Water Analysis and Volatiles Extraction (Light WAVE) instrument shown in Figure 1 for a follow-on prospecting mission, designed to be a rover payload for water ice prospecting at various depths and locations within PSRs. A key source of error for lunar water prospecting instruments, including Light WAVE, is the loss of water in an icy regolith sample to the lunar vacuum via sublimation due to heating above its ice-stable temperature. This abstract and conference presentation discuss a sublimation model for Light WAVE’s sample crucible using COMSOL Multiphysics to assess the sublimation losses that would occur between sample collection from an external drill and sealing the sample within Light WAVE’s boiler.

Lunar Polar Water↗

TRAC Time Tags of individual particle samples collected for microscopy analysis at RMBL [AMF2] from June 2023 to August 2023

The dataset presents the time tags of individual particle samples collected on microscopy substrates during the Surface Atmosphere Integrated Field Laboratory (SAIL) campaign in Gothic, CO. A Time Resolved Aerosol Collector was deployed at the Rocky Mountain Biological Laboratory, 200 m north of AMF2 to collect ambient particles. The instrument inlet was placed 5 m above ground level. Particles are deposited on 400 mesh copper carbon-B film TEM grids (Ted Pella 01814-F). Samples are sealed and currently stored at Purdue University. A subset of the samples can be shared. Please contact dataset authors for more information. The dataset reports the sample start times in UTC and MST along with the sample ID, used to guide its location and retrieval from the storage plate. TRAC sampling started on June 17, 2023, and ended on July 31, 2023.

54 ENVIRONMENTAL SCIENCES↗

Assessing the Oxygen Permeability of Candidate Asteroid Sample Containers With Optochemical Sensors

The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center currently curates 500 mg (10%) of carbonaceous asteroid Ryugu regolith collected by the Japan Aerospace and Exploration Agency’s Hayabusa II spacecraft and returned to Earth in 2021. In September 2023, NASA’s OSIRIS-REx spacecraft returned at least 70 grams of regolith collected from the surface of Carbonaceous Asteroid Bennu. These new astromaterials collections are stored and handled in gloveboxes and desiccators that are continuously purged with ultrapure nitrogen in order to minimize contamination and alteration of extraterrestrial samples from terrestrial environments, e.g., reaction with terrestrial oxygen and water. Ito et al. have previously reported on the development of containers to transport samples between facilities in inert, sealed environments; Hayabusa2 samples allocated to investigators by JAXA’s Extraterrestrial Sample Curation Center (ESCuC) are shipped in these Facility-to-Facility Transfer Containers (FFTCs). NASA curation has also been investigating sealed containers for storage, transportation, and allocation of Bennu and Ryugu regolith in sealed anoxic environments. In order to assess the ability of candidate sample containers to maintain nitrogen environments, we have utilized optochemical sensors to measure trace oxygen levels within sealed volumes.

C J Snead↗

High temperature (1200 C) ceramic-to-metal seal development

Two phases have been completed, of a program whose ultimate objective is the development of an alkali metal resistant, thermal shock resistant, leak-tight, and neutron radiation resistant ceramic-to-metal seal capable of operation at 1200 C for three to five years. The first phase involved the screening of platinum-base, vanadium-base and vanadium-niobium base brazes for the joining of Cb-1Zr or T-111 alloys to high purity alumina. The second phase involved studies of the performance of sealed capsule samples during 5000-hour aging tests at 800, 1000, and 1200 C in high vacuum. Sealed capsules which were made using pure vanadium braze, and were brazed at 1850 C for one minute, survived 64 thermal cycles to 1200 C at the heating/cooling rate of 100 C/minute. Vanadium braze samples survived 5000-hour aging tests at 800, 1000, and 1200 C. One thermally cycled sample survived a subsequent 5000-hour aging period at 1000 C, but another, at 1200 C, did not survive. It was concluded that a pure vanadium braze used to bond high purity alumina to Cb-1Zr alloy is the best of the systems studied, but that additional studies must be performed to establish its service temperature limitations for the desired three to five years' service.

Mckisson, R. L.↗

A systematic approach to resolve high impedance of multifunctional energy storage composites

Previous work has proposed and characterized the structural and electrical performance of Multifunctional Energy Storage Composite (MESC) structures: structural elements with embedded lithium-ion batteries which were developed by the Structures and Composite Laboratory (SACL) at Stanford University. This work conducts a comprehensive parametric study over the design variables in the manufacturing process to determine the root cause of increased DC impedance compared to commercial pouch cell batteries. Several MESC samples were assembled under various controlled environmental temperatures and pressures. The samples underwent Hybrid Peak Pulse Characterization (HPPC) to approximate the DC impedance as a function of state of charge (SOC). Failure limits of the battery with respect to assembly temperature and pressure were tested, and an MESC manufacturing simulation model was constructed in Abaqus to validate the manufacturing limits. Samples assembled without enough temperature or pressure failed due to a lack of structural integrity or hermetic seal. Conversely, samples which underwent elevated temperatures and pressures resulted in high DC impedance due to nonuniform electrolyte wetting. This work resolves the primary concern of MESC by achieving comparable DC impedance to commercial pouch cells of the same chemistry and testing procedure.

25 ENERGY STORAGE↗

OSIRIS-REx Curation: The First Year with Bennu Samples on Earth

The OSIRIS-REx (Origins, Spectral Interpretation, Resource Identification, and Security – Regolith Explorer) sample return capsule landed on the Utah Test and Training Range (UTTR) on September 24, 2023. Preparations for the curation of the sample from asteroid Bennu inside of this capsule spanned more than a decade. On the morning of landing, the sample return capsule was brought to a temporary cleanroom at UTTR for initial de-integration and connection of the sample canister to a nitrogen gas purge to protect the sample from modification by the terrestrial atmosphere. In the week following landing, the sample canister was flown to Houston while on nitrogen purge, transferred to a nitrogen atmosphere glovebox at NASA Johnson Space Center in which the canister lid was removed revealing small amounts of sample on the inside of the canister lid and avionics deck, some of this sample was allocated rapidly to the mission sample analysis team as “quick look” samples. Next, the Touch-and-Go sample acquisition mechanism (TAGSAM) head was disassembled inside of a specially designed glovebox. A challenge arose during one of the last stages of disassembly when two fasteners resisted being loosened. The curation team was able to remove 70.3 grams of asteroid sample from the TAGSAM head with those fasteners in-place and began initial sample processing which supported long-term curation of hermetically sealed and frozen samples, transfer of some samples to remote storage, and allocation of aggregate samples to the mission sample analysis team. Meanwhile, curation engineers developed a tool to remove the stubborn fasteners without contaminating the remaining sample, enabling the remaining bulk sample to be transferred to long-term storage trays in January 2024. With this second part of the bulk sample, the returned bulk asteroid sample reached 121.6 grams. During disassembly and prior to sealing the bulk sample trays into long-term storage containers, archival photographs were collected. Select particles are gradually being XCT scanned while inside of containers that hold a nitrogen atmosphere. The initial OSIRIS-REx sample catalog was released in spring 2024 with an update in fall 2024. The curation team will be busy working to allocate samples to scientists around the world for the foreseeable future.

Curation↗

Microgravity Disturbance Characterization of the Quench Module Insert (QMI) Phase Change Device (PCD)

The Materials Science Research Facility (MSRF) is a multi-user, multi-purpose facility for materials science research. One experiment within the MSRF will be the Quench Module Insert (QMI), a high-temperature furnace with unique capabilities for processing different classes of materials. The primary functions of the QMI furnace are to melt, directionally solidify, and quench metallic samples, providing data to aid in understanding the effects of the microgravity environment on the characteristics of these processed metals. The QMI houses sealed individual sample ampoules containing material to be processed. Quenching of the samples in the QMI furnace is accomplished by releasing low-melting-point metallic shoes into contact with the outside of the sample ampoule, dissipating heat and cooling the sample inside. The impact from this method of quench will induce sample vibrations which could be large enough to adversely affect sample quality. Utilizing breadboard hardware, the sample quench sequence, releasing the shoes, was conducted. Data was collected from accelerometers located on the breadboard sample cartridge, indicating the maximum acceleration achieved by the sample. The primary objective of the test described in this presentation was to determine the acceleration imparted on the sample by the shoe contact. From this information, the science community can better assess whether this method of quench will allow them to obtain the data they need.

Gattis, Christy↗

A dilatometer for volume-temperature determinations of liquids.

An instrument is described for the continuous volume measurement of small (3.7 ml) samples of liquids as a function of temperature. The sample is sealed in a stainless steel bellows chamber. Volume changes are measured with a linear variable differential transformer while temperature is measured by means of a thermistor and associated circuitry. Volume changes can be determined to better than .1 microliter ml over a temperature range of 10-60 C. The maximum sample volume change is 7%.

Rothman, J. E.↗

Processes to Open the Container and the Sample Catcher of the Hayabusa Returned Capsule in the Planetary Material Sample Curation Facility of JAXA

Japanese spacecraft Hayabusa, which returned from near-Earth-asteroid Itokawa, successfully returned its reentry capsule to the Earth, the Woomera Prohibited Area in Australia in Jun 13th, 2010, as detailed in another paper [1]. The capsule introduced into the Planetary Material Sample Curation Facility in the Sagamihara campus of JAXA in the early morning of June 18th. Hereafter, we describe a series of processes for the returned capsule and the container to recover gas and materials in there. A transportation box of the recovered capsule was cleaned up on its outer surface beforehand and introduced into the class 10,000 clean room of the facility. Then, the capsule was extracted from the box and its plastic bag was opened and checked and photographed the outer surface of the capsule. The capsule was composed of the container, a backside ablator, a side ablator, an electronic box and a supporting frame. The container consists of an outer lid, an inner lid, a frame for latches, a container and a sample catcher, which is composed of room A and B and a rotational cylinder. After the first check, the capsule was packed in a plastic bag with N2 again, and transferred to the Chofu campus in JAXA, where the X-ray CT instrument is situated. The first X-ray CT analysis was performed on the whole returned capsule for confirming the conditions of latches and O-ring seal of the container. The analysis showed that the latches of the container should have worked normally, and that the double Orings of the container seemed to be sealed its sample catcher with no problem. After the first X-ray CT, the capsule was sent back to Sagamihara and introduced in the clean room to exclude the electronic box and the side ablator from the container by hand tools. Then the container with the backside ablator was set firmly to special jigs to fix the lid of container tightly to the container and set to a milling machine. The backside ablator was drilled by the machine to expose heads of bolts, which combined the ablator to the outer lid of the container, and after the drilling had been finished, all the bolts were unscrewed and the backside ablator was removed from the container. Then, the container was sent to the Chofu X-ray facility again to examine in detail by a micro X-ray CT instrument in order to reconfirm that the condition of the latches of the lid of container was normal and that its double O-ring seemed to have been sealed after the last X-ray CT analysis.

Fujimura, A.↗