Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Simulating Reflected Light Exoplanet Spectra of the Promising Direct Imaging Target, υ Andromedae d, with a New, Fast Sampling Method Using the Planetary Spectrum Generator

Simulations of exoplanet albedo profiles are key to planning and interpreting future direct imaging observations. In this paper we demonstrate the use of the Planetary Spectrum Generator (PSG) to produce simulations of reflected light exoplanet spectra. We use PSG to examine multiple issues relevant to all models of directly imaged exoplanet spectra and to produce sample spectra of the bright, nearby exoplanet υ Andromedae d (υ And d), a potential direct imaging target for next-generation facilities. We introduce a new, fast, and accurate subsampling technique that enables calculations of disk-integrated spectra one order of magnitude faster than Chebyshev–Gauss sampling for moderate- to high-resolution sampling. Using this method and a first-principles-derived atmosphere for υ And d, we simulate phase-dependent spectra for a variety of different potential atmospheric configurations. The simulated spectra for υ And d include versions with different haze and cloud properties. Based on our combined analysis of this planet’s orbital parameters, phase- and illumination-appropriate model spectra, and realistic instrument noise parameters, we find that υ And d is a potentially favorable direct imaging and spectroscopy target for the Coronagraph Instrument (CGI) on the Nancy Grace Roman Space Telescope. When a noise model corresponding to the Roman CGI SPC spectroscopy mode is included, PSG predicts the time required to reach a signal-to-noise ratio of 10 of the simulated spectra in both the central wavelength bin of the Roman CGI SPC spectroscopy mode (R = 50 spectrum) and of the Band 1 HLC imaging mode is approximately 400 and less than 40 hr, respectively. We also discuss potential pathways to extricating information about the planet and its atmosphere with future observations and find that Roman observations may be able to bound the interior temperature of the planet.

74 ATOMIC AND MOLECULAR PHYSICS↗

Rossi-alpha Uncertainty Quantification by Analytic, Bootstrap, and Sample Methods to Inform Fitting Best Practices

The prompt neutron period (the negative reciprocal of the prompt neutron decay constant) can be estimated using the Rossi-alpha technique that is predicated on fitting Rossi alpha histograms and of interest in nuclear criticality safety and nonproliferation. The histograms are traditionally fit with a one-exponential model; however, recent work has proposed a two-exponential model to account for reflector induced phenomenon. Until recently, the uncertainty quantification for either model was inadequate (inaccurate and demanded large measurement times). Measurement uncertainty quantification by sample and analytic methods was developed and validated in Ref. The purpose of this transaction is to (i) validate a new bootstrap method by comparing bin-by-bin error bar estimates and (ii) demonstrate how to choose bin widths and reset times to optimize precision and accuracy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simple grab sampling methods for the measurement of WL(Rn) and WL(Tn) concentrations

If one is air sampling for short -lived radon ( 222 Rn) progeny only, then it is the so-called working level concentration (WL) that is normally determined. Often, a so-called short-term grab air sample is utilized followed by gross α counting techniques. Care on the part of health physics personnel is required here, as is an uninterrupted work time.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

False negative rate and other performance measures of a sponge-wipe surface sampling method for low contaminant concentrations.

Recovery of spores from environmental surfaces is known to vary due to sampling methodology, techniques, spore size and characteristics, surface materials, and environmental conditions. A series of tests were performed to evaluate a new, validated sponge-wipe method. Specific factors evaluated were the effects of contaminant concentrations and surface materials on recovery efficiency (RE), false negative rate (FNR), limit of detection (LOD) - and the uncertainties of these quantities. Ceramic tile and stainless steel had the highest mean RE values (48.9 and 48.1%, respectively). Faux leather, vinyl tile, and painted wood had mean RE values of 30.3, 25.6, and 25.5, respectively, while plastic had the lowest mean RE (9.8%). Results show a roughly linear dependence of surface roughness on RE, where the smoothest surfaces have the highest mean RE values. REs were not influenced by the low spore concentrations tested (3 x 10{sup -3} to 1.86 CFU/cm{sup 2}). The FNR data were consistent with RE data, showing a trend of smoother surfaces resulting in higher REs and lower FNRs. Stainless steel generally had the lowest mean FNR (0.123) and plastic had the highest mean FNR (0.479). The LOD{sub 90} varied with surface material, from 0.015 CFU/cm{sup 2} on stainless steel up to 0.039 on plastic. Selecting sampling locations on the basis of surface roughness and using roughness to interpret spore recovery data can improve sampling. Further, FNR values, calculated as a function of concentration and surface material, can be used pre-sampling to calculate the numbers of samples for statistical sampling plans with desired performance, and post-sampling to calculate the confidence in characterization and clearance decisions.

09 BIOMASS FUELS↗

A single-sample method for normalizing and combining full-resolution copy numbers from multiple platforms, labs and analysis methods

Motivation: The rapid expansion of whole-genome copy number (CN) studies brings a demand for increased precision and resolution of CN estimates. Recent studies have obtained CN estimates from more than one platform for the same set of samples, and it is natural to want to combine the different estimates in order to meet this demand. Estimates from different platforms show different degrees of attenuation of the true CN changes. Similar differences can be observed in CNs from the same platform run in different labs, or in the same lab, with different analytical methods. This is the reason why it is not straightforward to combine CN estimates from different sources (platforms, labs and analysis methods). Results: We propose a single-sample multi source normalization that brings full-resolution CN estimates to the same scale across sources. The normalized CNs are such that for any underlying CN level, their mean level is the same regardless of the source, which make them better suited for being combined across sources, e.g. existing segmentation methods may be used to identify aberrant regions. We use microarray-based CN estimates from ‘The Cancer Genome Atlas’ (TCGA) project to illustrate and validate the method. We show that the normalized and combined data better separate two CN states at a given resolution. We conclude that it is possible to combine CNs from multiple sources such that the resolution becomes effectively larger, and when multiple platforms are combined, they also enhance the genome coverage by complementing each other in different regions. Availability: A bounded-memory implementation is available in aroma.cn.

59 BASIC BIOLOGICAL SCIENCES↗

Monte Carlo burnup code acceleration with the correlated sampling method. Preliminary test on an UOX cell with TRIPOLI-4{sup R}

For several years, Monte Carlo burnup/depletion codes have appeared, which couple a Monte Carlo code to simulate the neutron transport to a deterministic method that computes the medium depletion due to the neutron flux. Solving Boltzmann and Bateman equations in such a way allows to track fine 3 dimensional effects and to get rid of multi-group hypotheses done by deterministic solvers. The counterpart is the prohibitive calculation time due to the time-expensive Monte Carlo solver called at each time step. Therefore, great improvements in term of calculation time could be expected if one could get rid of Monte Carlo transport sequences. For example, it may seem interesting to run an initial Monte Carlo simulation only once, for the first time/burnup step, and then to use the concentration perturbation capability of the Monte Carlo code to replace the other time/burnup steps (the different burnup steps are seen like perturbations of the concentrations of the initial burnup step). This paper presents some advantages and limitations of this technique and preliminary results in terms of speed up and figure of merit. Finally, we will detail different possible calculation scheme based on that method. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Implementation and testing of the on-the-fly thermal scattering Monte Carlo sampling method for graphite and light water in MCNP6

Here, a proper treatment of thermal neutron scattering requires accounting for chemical binding through a scattering law S(α,β,T). Monte Carlo codes sample the secondary neutron energy and angle after a thermal scattering event from probability tables generated from S(α,β,T) tables at discrete temperatures, requiring a large amount of data for multiscale and multiphysics problems with detailed temperature gradients. We have previously developed a method to handle this temperature dependence on-the-fly during the Monte Carlo random walk using polynomial expansions in 1/T to directly sample the secondary energy and angle. In this paper, the on-the-fly method is implemented into MCNP6 and tested in both graphite-moderated and light water-moderated systems. The on-the-fly method is compared with the thermal ACE libraries that come standard with MCNP6, yielding good agreement with integral reactor quantities like k-eigenvalue and differential quantities like single-scatter secondary energy and angle distributions. The simulation runtimes are comparable between the two methods (on the order of 5–15% difference for the problems tested) and the on-the-fly fit coefficients only require 5–15 MB of total data storage.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Derivation and verification of the direct-sampling method for simulating Monte Carlo flight paths in tetrahedral meshes with linear finite-element cross sections

This paper provides a derivation of a direct-sampling approach for modeling continuously varying cross sections in tetrahedral-mesh-based Monte Carlo codes. Specifically, cross sections are spatially approximated using linear nodal finite elements. A linearization strategy is provided for non-linearly varying cross sections. The method is verified against seven analytical pure-absorber test problems. These test problems also highlight the benefit of using linear finite elements over element-wise-constant cross sections.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A comb-sampling method for enhanced mass analysis in linear electrostatic ion traps

In this paper an algorithm for extracting spectral information from signals containing a series of narrow periodic impulses is presented. Such signals can typically be acquired by pickup detectors from the image-charge of ion bunches oscillating in a linear electrostatic ion trap, where frequency analysis provides a scheme for high-resolution mass spectrometry. To provide an improved technique for such frequency analysis, we introduce the CHIMERA algorithm (Comb-sampling for High-resolution IMpulse-train frequency ExtRAaction). This algorithm utilizes a comb function to generate frequency coefficients, rather than using sinusoids via a Fourier transform, since the comb provides a superior match to the data. This new technique is developed theoretically, applied to synthetic data, and then used to perform high resolution mass spectrometry on real data from an ion trap. If the ions are generated at a localized point in time and space, and the data is simultaneously acquired with multiple pickup rings, the method is shown to be a significant improvement on Fourier analysis. The mass spectra generated typically have an order of magnitude higher resolution compared with that obtained from fundamental Fourier frequencies, and are absent of large contributions from harmonic frequency components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radioisotope Analysis of Wastewater from Livermore Site Retention Tanks by Gel Laboratory Gross Alpha, Gross Beta and Tritium Sampling Method

Lawrence Livermore National Laboratory discharged approximately 4.4% of the City of Livermore’s total wastewater in 2022 (LLNL’s Annual Site Environmental Report, Chapter 5, 2022). This volume includes wastewater from Sandia National Laboratories (SNL) and some process wastewater from Site 300. Due to the high volume and constituents of the discharge, LLNL works alongside the City of Livermore under permit #1250, requiring wastewater generated to be monitored and sampled in accordance with permit limits. Process wastewater, from buildings with the highest risk to sewer, is collected by wastewater retention tanks throughout the Livermore Site and sampled prior to discharge. Domestic wastewater directly discharges to sanitary sewer. To maintain permit requirements and ensure proper wastewater discharge practices, an internal wastewater audit was conducted during the summer of 2023. Current wastewater practices, regulatory knowledge and risk management across various Livermore Site buildings were evaluated. Workspaces connected to a wastewater retention tank and sanitary sewer drains were major focus areas. Data collected from walk-throughs prompted further evaluation as many practices were reported to be done based on historical usage. A table of concerns was created to showcase reasons for auditing and proceeding action. An analysis of current and historical retention tank usage throughout LLNL Livermore Site buildings with radioisotope results over a 5-year period from 2019 to 2024, was done to assess building trends and any significant changes throughout the 5-year period. Analytes evaluated were Gross Alpha, Gross Beta and Tritium (GABT) of eleven buildings at the Livermore Site, posing the highest risk to sanitary sewer for radioisotopes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Study of runaway electrons using the conditional average sampling method in the Damavand tokamak

Some experiments for studying the runaway electron (RE) effects have been performed using the poloidal magnetic probes system installed around the plasma column in the Damavand tokamak. In these experiments, the so-called runaway-dominated discharges were considered in which the main part of the plasma current is carried by REs. The induced magnetic effects on the poloidal pickup coils signals are observed simultaneously with the Parail–Pogutse instability moments for REs and hard X-ray bursts. The output signals of all diagnostic systems enter the data acquisition system with 2 Msample/(s channel) sampling rate. The temporal evolution of the diagnostic signals is analyzed by the conditional average sampling (CAS) technique. The CASed profiles indicate RE collisions with the high-field-side plasma facing components at the instability moments. The investigation has been carried out for two discharge modes—low-toroidal-field (LTF) and high-toroidal-field (HTF) ones—related to both up and down limits of the toroidal magnetic field in the Damavand tokamak and their comparison has shown that the RE confinement is better in HTF discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stopping Power of Different Ions in Si Measured with a Bulk Sample Method and Bayesian Inference Data Analysis

The accuracy of ion beam analysis experiments depends critically on the stopping power values available. While for H and He ions accuracies normally better than 5% are achieved by usual interpolative schemes such as SRIM, for heavier ions the accuracy is worse. One of the main reasons is that the experimental data bases are very sparse, even for important materials such as Si. New measurements are therefore needed. Measurement of stopping power is often made with transmission in thin films, with the usual problems of film thickness homogeneity. We have previously developed an alternative method based on measuring bulk spectra, and fitting the yield by treating the stopping power as a fit parameter in a Bayesian inference Markov chain Monte Carlo procedure included in the standard IBA code NDF. We report on improvements of the method and on its application to the determination of the stopping power of {sup 7}Li in Si. To validate the method, we also apply it to the stopping of {sup 4}He in Si, which is known with 2% accuracy.

36 MATERIALS SCIENCE↗