An analysis of data related to the minimum temperatures for valid testing in cryogenic wind tunnels using nitrogen as the test gas

The minimum operating temperature which avoids adverse low temperature effects, such as condensation, has been determined at a free stream Mach number of 0.85 for flow over a 0.137 meter airfoil mounted at zero incidence in the Langley 1/3 meter transonic cryogenic tunnel. The onset of low temperature effects is established by comparing the pressure coefficient measured at a given orifice for a particular temperature with those measured at temperatures sufficiently above where low temperature effects might be expected to occur. The pressure distributions over the airfoil are presented in tabular form. In addition, the comparisons of the pressure coefficient as a function of total temperature are presented graphically for chord locations of 0, 25, 50, and 75 percent. Over the 1.2 to 4.5 atmosphere total pressure range investigated, low temperature effects are not detected until total temperatures are 2 K, or more, below free stream saturation temperatures.

Hall, R. M.↗

Onset of condensation effects in cryogenic wind tunnels

The onset of condensation effects in cryogenic wind tunnels which limits their minimum operating temperatures is examined. If this onset of effects occurs below saturation temperature, then the tunnels may be operated at the lower temperatures and additional benefits to cryogenic tunnel operation resulting in increased Reynolds number capability and reduced operating costs. Both homogeneous and heterogeneous nucleation processes are discussed as they pertain to continuous flow cryogenic wind tunnels. Examples from condensation experiments in the 0.3 m Transonic Cryogenic Tunnel are also reviewed.

Hall, R. M.↗

Numerical studies of the effects of jet-induced mixing on liquid-vapor interface condensation

Numerical solutions of jet-induced mixing in a partially full cryogenic tank are presented. An axisymmetric laminar jet is discharged from the central part of the tank bottom toward the liquid-vapor interface. Liquid is withdrawn at the same volume flow rate from the outer part of the tank. The jet is at a temperature lower than the interface, which is maintained at a certain saturation temperature. The interface is assumed to be flat and shear-free and the condensation-induced velocity is assumed to be negligibly small compared with radial interface velocity. Finite-difference method is used to solve the nondimensional form of steady state continuity, momentum, and energy equations. Calculations are conducted for jet Reynolds numbers ranging from 150 to 600 and Prandtl numbers ranging from 0.85 to 2.65. The effects of above stated parameters on the condensation Nusselt and Stanton numbers which characterize the steady-state interface condensation process are investigated. Detailed analysis to gain a better understanding of the fundamentals of fluid mixing and interface condensation is performed.

Lin, Chin-Shun↗

Numerical studies of the effects of jet-induced mixing on liquid-vapor interface condensation

Numerical solutions of jet-induced mixing in a partially full cryogenic tank are presented. An axisymmetric laminar jet is discharged from the central part of the tank bottom toward the liquid-vapor interface. Liquid is withdrawn at the same volume flow rate from the outer part of the tank. The jet is at a temperature lower than the interface, which is maintained at a certain saturation temperature. The interface is assumed to be flat and shear-free and the condensation-induced velocity is assumed to be negligibly small compared with radial interface velocity. Finite-difference method is used to solve the nondimensional form of steady state continuity, momentum, and energy equations. Calculations are conducted for jet Reynolds numbers ranging from 150 to 600 and Prandtl numbers ranging from 0.85 to 2.65. The effects of above stated parameters on the condensation Nusselt and Stanton numbers which characterize the steady-state interface condensation process are investigated. Detailed analysis to gain a better understanding of the fundamentals of fluid mixing and interface condensation is performed.

Lin, Chin-Shun↗

Vapor condensation at the free surface of an axisymmetric liquid mixed by a laminar jet

This paper presents numerical solutions of jet-induced mixing in a partially full cryogenic tank. An axisymmetric laminar jet is discharged from the central part of the tank bottom toward the liquid-vapor interface. Liquid is withdrawn at the same volume flow rate from the outer part of the tank. The jet is at a temperature lower than the interface, which is maintained at a certain saturation temperature. The interface is assumed to be flat and shear free and the condensation-induced velocity is assumed to be negligibly small compared with radial interface velocity. Finite-difference method is used to slove the nondimensional form of steady-state continuity, momentum, and energy equations. Calculations are conducted for jet Reynolds numbers ranging from 150 to 600 and Prandtl numbers ranging from 0.85 to 2.65. The effects of previously stated parameters on the condensation Nusselt and Stanton numbers that characterize the steady-state interface condensation process are investigated. Detailed analysis is performed to gain a better understanding of the fundamentals of fluid mixing and interface condensation.

Lin, Chin-Shun↗

Methods of Controlling the Loop Heat Pipe Operating Temperature

The operating temperature of a loop heat pipe (LHP) is governed by the saturation temperature of its compensation chamber (CC); the latter is in turn determined by the balance among the heat leak from the evaporator to the CC, the amount of subcooling carried by the liquid returning to the CC, and the amount of heat exchanged between the CC and ambient. The LHP operating temperature can be controlled at a desired set point by actively controlling the CC temperature. The most common method is to cold bias the CC and use electric heater power to maintain the CC set point temperature. The required electric heater power can be large when the condenser sink is very cold. Several methods have been developed to reduce the control heater power, including coupling block, heat exchanger and separate subcooler, variable conductance heat pipe, by-pass valve with pressure regulator, secondary evaporator, and thermoelectric converter. The paper discusses the operating principles, advantages and disadvantages of each method.

Ku, Jentung↗

Analysis of Water Recovery Rate from the Heat Melt Compactor

Human space missions generate trash with a substantial amount of plastic (20% or greater by mass). The trash also contains water trapped in food residue and paper products and other trash items. The Heat Melt Compactor (HMC) under development by NASA Ames Research Center (ARC) compresses the waste, dries it to recover water and melts the plastic to encapsulate the compressed trash. The resulting waste disk or puck represents an approximately ten-fold reduction in the volume of the initial trash loaded into the HMC. In the current design concept being pursued, the trash is compressed by a piston after it is loaded into the trash chamber. The piston face, the side walls of the waste processing chamber and the end surface in contact with the waste can be heated to evaporate the water and to melt the plastic. Water is recovered by the HMC in two phases. The first is a pre-process compaction without heat or with the heaters initially turned on but before the waste heats up. Tests have shown that during this step some liquid water may be expelled from the chamber. This water is believed to be free water (i.e., not bound with or absorbed in other waste constituents) that is present in the trash. This phase is herein termed Phase A of the water recovery process. During HMC operations, it is desired that liquid water recovery in Phase A be eliminated or minimized so that water-vapor processing equipment (e.g., condensers) downstream of the HMC are not fouled by liquid water and its constituents (i.e., suspended or dissolved matter) exiting the HMC. The primary water recovery process takes place next where the trash is further compacted while the heated surfaces reach their set temperatures for this step. This step will be referred to herein as Phase B of the water recovery process. During this step the waste chamber may be exposed to different selected pressures such as ambient, low pressure (e.g., 0.2 atm), or vacuum. The objective for this step is to remove both bound and any remaining free water in the trash by evaporation. The temperature settings of the heated surfaces are usually kept above the saturation temperature of water but below the melting temperature of the plastic in the waste during this step to avoid any encapsulation of wet trash which would reduce the amount of recovered water by blocking the vapor escape. In this paper, we analyze the water recovery rate during Phase B where the trash is heated and water leaves the waste chamber as vapor, for operation of the HMC in reduced gravity. We pursue a quasi-one-dimensional model with and without sidewall heating to determine the water recovery rate and the trash drying time. The influences of the trash thermal properties, the amount of water loading, and the distribution of the water in the trash on the water recovery rates are determined.

Heat Melt Compactor↗

The Life and Times of Supervolcanoes: Inferences from Long Valley Caldera

Cataclysmic eruptions of silicic magma from "supervolcanoes" are among the most awe-inspiring natural phenomena found in the geologic record, in terms of size, power, and potential hazard. Based on the repose intervals between eruptions of this magnitude, the magmas responsible for them could accumulate gradually in the shallow crust over time scales that may be in excess of a million years (Smith, 1979; Spera and Crisp, 1981; Shaw, 1985). Pre-eruption magma residence time scales can also be inferred from the age difference between eruption (i.e., using 40Ar/39Ar dating to determine the time when hot erupted material cools to below its Ar closure temperature, 200 to 600 degC) and early pre-eruption crystallization (i.e., zircon saturation temperatures; Reid et al., 1997). I will discuss observations from Long Valley a Quaternary volcanic center in California. Long Valley is a voluminous, dominantly silicic caldera system. Based on extensive dating of accessory minerals (e.g., U-Th-Pb dating of zircon and allanite) along with geochemical and isotopic data we find that silicic magmas begin to crystallize 10's to 100's of thousands of years prior to their eruption and that rhyolites record episodes of punctuated and independent evolution rather than the periodic tapping of a long-lived magma. The more punctuated versus more gradual magma accumulation rates required by the absolute and model ages, respectively, imply important differences in the mass and heat fluxes associated with the generation, differentiation, and storage of voluminous rhyolites and emphasize the need to reconcile the magmatic age differences.

Simon, Justin↗

BOILING HEAT TRANSFER TO LIQUID HYDROGEN AND NITROGEN IN FORCED FLOW

Boiling heat transfer to liquid hydrogen and nitrogen was investigated experimentally. Results are presented from a study of bulk boiling inside a cylindrical tube under vertically upward forced-flow conditions. A 0.555-inch-inside-diameter and 16 (1/8)-inch-long electrically heated stainless-steel tube was used. The range of variables studied for hydrogen were mass velocity of 2850 to 17,000 pounds per hour per square foot, local heat flux of 3600 to 40,000 Btu per hour per square foot, inlet pressure of 30 to 74 pounds per square inch absolute, and inlet subcooling of 0° to 9° R. Nitrogen test conditions were mass velocity of 15,000 to 56,000 pounds per hour per square foot, local heat flux of 2300 to 40,000 Btu per hour per square foot, inlet pressure of 47 to 56 pounds per square inch absolute, and inlet sub cooling of 1° to 6° R. The axial distribution of the tube-wall temperatures is presented. A transition in the type of boiling heat transfer was obtained. The critical heat flux corresponding to this transition was determined over a range of flow and heating rates and local qualities. At specific combinations of flow and transition location, a range of critical-heat-flux values was obtained and maximum values were determined. The maximum critical heat flux increased with increasing fluid-flow rate and decreased with increasing length of tube before transition. Similar variations of the maximum critical heat flux have been reported for water. The tube-inner-wall temperatures upstream of transition were essentially uniform and were only slightly greater than the fluid saturation temperature. The Wall-temperature profiles downstream of transition generally resembled those obtained in film-boiling studies and appeared to be strongly dependent upon local quality at the point of transition. Maximum wall temperatures of 9000 and 18000 R were obtained with hydrogen and nitrogen, respectively. Fluctuations of pressure, flow rate, and temperature occurred during some of the boiling tests. Under some conditions, maximum critical-heat-flux values were attained during steady-state operation with fluctuations. In other cases the fluctuations became uncontrolled, and critical-flux values less than the maximum values were obtained upon restabilization of the test conditions. No measurable pressure drop across the test section was obtained at any condition.

LIQUID HYDROGEN↗

Summary of LO2/Ethanol OMS/RCS Technology and Advanced Development 99-2744

NASA is pursuing non-toxic propellant technologies applicable to RLV and Space Shuttle orbital maneuvering system (OMS) and reaction control system (RCS). The primary objectives of making advancements in an OMS/RCS system are improved safety, reliability, and reduced operations and maintenance cost, while meeting basic operational and performance requirements. An OMS/RCS has a high degree of direct interaction with the vehicle and crew and requires subsystem and components that are compatible with integration into the vehicle with regard to external mold-line, power, and thermal control. In July 1997, a Phase I effort for the technology and advanced development of an upgrade of the space shuttle was conducted to define the system architecture, propellant tank, feed system, RCS thrusters, and OMS engine. Phase I of the project ran from July 1997 to October 1998. Phase II is currently being planned for the development and test of full-scale prototype of the system in 1999 and 2000. The choice of pressure-fed liquid oxygen (LO2) and ethanol is the result of numerous trade studies conducted from 1980 to 1996. Liquid oxygen and ethanol are clean burning, high-density propellants that provide a high degree of commonality with other spacecraft subsystems including life support, power, and thermal control, and with future human exploration and development of space missions. The key to this pressure-fed system is the use of subcooled liquid oxygen at 350 psia. In this approach, there is 80 degrees R of subcooling, which means that boil-off will not occur until the temperature has risen 80 R. The sub-cooling results naturally from loading propellants at 163 R, which is the saturation temperature at 14.7 psia, and then pressurizing to 350 psia on the launch pad. Thermal insulation and conditioning techniques are then used to limit the LO2 temperature to 185 R maximum, and maintain the sub-cooling. The other key is the wide temperature range of ethanol, -173 F to +300 F, which can provide heat to gasify liquid oxygen or provide a good coolant.

Curtis, Leslie A.↗

Operation of helium sub-atmospheric multistage cryogenic centrifugal compressor trains: Part 1 – Steady state modeling and speed ratio selection

Helium cryogenic systems which can provide cooling below the normal boiling point of helium (approximately 4.2 K) are often required by superconducting radio-frequency niobium resonators utilized in modern high-energy particle accelerators. Achieving temperatures below 4.2 K generally involves operating a cryogenic vessel with liquid helium under sub-atmospheric conditions, thereby lowering the saturation pressure and corresponding saturation temperature. Over the last several decades, multi-stage cryogenic centrifugal compressor trains (CC’s) have been operated efficiently and reliably within large-scale cryogenic systems to continuously evacuate helium vapor generated by a device within the vessel, maintaining sub-atmospheric conditions in the vessel while pressurizing the return vapor to above atmospheric conditions. Traditionally, these CC systems have been operated using empirically derived control philosophies and insight gathered from previous operational experience. Recent efforts at the Facility for Rare Isotope Beams (FRIB) have been aimed at the development of a theoretical basis to characterize the operation of multi-stage cryogenic centrifugal compressor train and utilizing predictive model results to generate control parameters. The objective of this research was identifying operational points which adequately balance cryogenic system efficiency, stability, and overall ease of operation. Furthermore, this manuscript provides an overview of the predictive model development, characterization of the FRIB cryogenic centrifugal compressors and implementation of the predicted performance results during steady-state system operation.

Compressor train control↗

Numerical investigation of the thermal stratification in cryogenic tanks subjected to wall heat flux

The flow pattern and thermal stratification of a cryogenic cylindrical tank are numerically studied. The tank sidewall is subjected to either a uniform heat-flux or two discrete levels of uniform heat-flux at the upper and lower halves of the tank wall. The tank bottom is kept at a constant temperature controlled by the heat exchanger of a thermodynamic vent system. The tank pressure is also assumed constant resulting in a constant saturation temperature at the interface which is higher than the tank bottom temperature. The effects of vapor motion and vapor superheat on the mass and heat transfer processes at the interface are assumed negligible such that the calculations of liquid region can be decoupled from the vapor region. Dimensionless steady-state conservation equations are solved by a finite-difference method. The effects of modified Rayleigh number, Prandtl number, tank aspect ratio, wall heat-flux parameter, and wall heat-flux distribution on the liquid velocity and temperature fields are investigated. Also, their effects on the rate of heat transfer through the interface and the tank bottom are examined.

Lin, Chin-Shun↗

Numerical investigation of the thermal stratification in cryogenic tanks subjected to wall heat flux

The flow pattern and thermal stratification of a cryogenic cylindrical tank are numerically studied. The tank sidewall is subjected to either a uniform heat-flux or two discrete levels of uniform heat-flux at the upper and lower halves of the tank wall. The tank bottom is kept at a constant temperature controlled by the heat exchanger of a thermodynamic vent system. The tank pressure is also assumed constant resulting in a constant saturation temperature at the interface which is higher than the tank bottom temperature. The effects of vapor motion and vapor superheat on the mass and heat transfer processes at the interface are assumed negligible such that the calculations of liquid region can be decoupled from the vapor region. Dimensionless steady-state conservation equations are solved by a finite-difference method. The effects of modified Rayleigh number, Prandtl number, tank aspect ratio, wall heat-flux parameter, and wall heat-flux distribution on the liquid velocity and temperature fields are investigated. Also, their effects on the rate of heat transfer through the interface and the tank bottom are examined.

Lin, Chin-Shun↗

Determination of the Accommodation Coefficient Using Vapor/gas Bubble Dynamics in an Acoustic Field

Nonequilibrium liquid/vapor phase transformations can occur in superheated or subcooled liquids in fast processes such as in evaporation in a vacuum. The rate at which such a phase transformation occurs depends on the "condensation" or "accommodation" coefficient, Beta, which is a property of the interface. Existing measurement techniques for Beta are complex and expensive. The development of a relatively inexpensive and reliable technique for measurement of Beta for a wide range of substances and temperatures is of great practical importance. The dynamics of a bubble in an acoustic field strongly depends on the value of Beta. It is known that near the saturation temperature, small vapor bubbles grow under the action of an acoustic field due to "rectified heat transfer." This finding can be used as the basis for an effective measurement technique of Beta. We developed a theory of vapor bubble behavior in an isotropic acoustic wave and in a plane standing acoustic wave. A numerical code was developed which enables simulation of a variety of experimental situations and accurately takes into account slowly evolving temperature. A parametric study showed that the measurement of Beta can be made over a broad range of frequencies and bubble sizes. We found several interesting regimes and conditions which can be efficiently used for measurements of Beta. Measurements of Beta can be performed in both reduced and normal gravity environments.

Gumerov, Nail A.↗

Analysis of the Pressure Rise in a Partially Filled Liquid Tank in Microgravity with Low Wall Heat Flux and Simultaneous Boiling and Condensation

Experiments performed with Freon 113 in the space shuttle have shown that in a pro- cess of very slow heating, high liquid superheats can be sustained for a long period in microgravity. In a closed system explosive vaporization of superheated liquid resulted in pressure spikes of varying magnitudes. In this paper, we analyze the pressure rise in a partially lled closed tank in which a large vapor bubble (i.e., ullage) is initially present, and the liquid is subjected to a low wall heat ux. The liquid layer adjacent to the wall becomes superheated until the temperature for nucleation of the bubbles (or the incipience of boiling) is achieved. In the absence of the gravity-induced convection large quantities of superheated liquid can accumulate over time near the heated surface. Once the incipience temperature is attained, explosive boiling occurs and the vapor bubbles that are produced on the heater surface tend to quickly raise the tank pressure. The liquid-vapor saturation temperature increases as well. These two e ects tend to induce condensation of the large ullage bubble that is initially present, and tends to mitigate the tank pressure rise. As a result, the tank pressure is predicted to rise sharply, attain a maximum, and subsequently decay slowly. The predicted pressure rise is compared with experimental results obtained in the microgravity environments of the space shuttle for Freon 113. The analysis is appli- cable, in general to heating of liquid in closed containers in microgravity and to cryogenic fuel tanks, in particular where small heat leaks into the tank are unavoidable.

Hasan, Mohammad M.↗

Cryogenic Transfer Line Chilldown

The transient behavior of a small scale cryogenic transfer line was investigated during chilldown to cryogenic temperatures. The vacuum-jacketed apparatus consisted of a vertical tube followed by a near horizontal tube. The apparatus was equipped with view ports in the near horizontal section to allow visual observation of the flow patterns. Wall temperatures were measured at various locations along the length of the transfer line. Each test was conducted at a constant liquid volumetric flowrate at the transfer line inlet until saturation temperatures were obtained throughout the system.

VanDresar, Neil T.↗

Vapor-modulated heat pipe for improved temperature control

Dryout induced by vapor throttling makes control of equipment temperature less dependent on variations in sink environment. Mechanism controls flow of vapor in heat pipe by using valve in return path to build difference in pressure and also difference in saturation temperature of the vapor. In steady state, valve closes just enough to produce partial dryout that achieves required temperature drop.

Edwards, D. K.↗

Evaluation of Mechanical and Thermomechanical Water Vapor Compression Techniques for Enabling High Temperature Lift Hydration-Based Chemical Heat Pumps

Achieving high temperature lifts (>200 K) via a chemical heat pump based on salt hydration/dehydration reactions requires the transport of water vapor from low to high pressure. Alternative compression approaches require condensing of low-pressure water vapor, pumping of liquid water, and subsequent evaporation when the low-side pressure corresponds to sub-ambient water saturation temperatures. Thus, this study compares four steam compression methods for use within a chemical heat pump system based on a reversible calcium oxide hydration/dehydration reaction with a temperature lift from 350 °C heat to >600 °C. Purely mechanical and thermochemical/mechanical compression technologies are considered. A parametric study of maximum allowable temperature, the isentropic efficiency of mechanical compressors, the effectiveness of heat exchangers, and the assumed allowable heat exchanger pressure drop is conducted to determine the mechanical and thermal energy consumed per kilogram of compressed steam. The system complexity in terms of the number of main system components, maximum pressure ratio, and maximum allowable temperature is estimated. Model results show an absorption-based steam compressor has the highest exergetic efficiency for the required chemical heat pump required conditions. As a result, this system configuration was then experimentally demonstrated to illustrate the impact of system performance on component effectiveness.

Advanced reactors↗