Search NASA⌕ Search

SEARCH · Search NASA

Results for “screening interval”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Colonoscopy Screening in the US Astronaut Corps

BACKGROUND: Historically, colonoscopy screenings for astronauts have been conducted to ensure that astronauts are in good health for space missions. Recently this historical data has been identified as being useful for developing an occupational surveillance requirement. It can be used to assess overall colon health and to have a point of reference for future tests in current and former astronauts, as well as to follow-up and track rates of colorectal cancer and polyps. These rates can be compared to military and other terrestrial populations. In 2003, the active astronaut colonoscopy requirements changed to require less frequent colonoscopies. Since polyp removal during a colonoscopy is an intervention that prevents the polyp from potentially developing into cancer, the procedure decreases the individual's risk for colon cancer. The objective of this study is to evaluate the possible effect of increased follow-up times between colonoscopies on the number and severity of polyps identified during the procedures among both current and former NASA astronauts. Initial results and forward work regarding astronaut colonoscopy screenings will be presented. METHODS: A retrospective study of all colonoscopy procedures performed on NASA astronauts between 1962 and 2015 (both during active career and retirement) was conducted by review of the JSC Clinic Electronic Medical Record and Lifetime Surveillance of Astronaut Health (LSAH) database for colonoscopy screening procedures and pathology reports. The timeframe of interest was from the time of selection into the Astronaut Corps through May 2015 or death. For each colonoscopy report, the following data were captured: date of procedure, age at time of procedure, reason for procedure, quality of bowel prep, completion of procedure and/or reason for termination of procedure, findings of procedure, subsequent treatment (if any), recommended follow-up interval, actual follow up interval, family history of polyps or colon cancer, and other significant items or discrepancies. The population consisted of 338 astronauts: 52 females, 286 males. Of these, 56 were deceased, and 11 astronauts had no record of any colonoscopies. Because of a screening requirement change in 2003, analyses were conducted to determine if there were differences between the two time periods. One-sided Wilcoxon rank sum tests were used to identify statistically significant differences between the two time periods. RESULTS: There was a combined total of 1,964 colonoscopy screenings identified. The average follow-up intervals between colonoscopies were indeed longer after the screening requirement change than before the change. The mean follow-up interval pre -2003 was 3.59 years, while post-2003 it increased to 4.35 years. The statistical significance of this difference was confirmed using a one sided Wilcoxon rank sum test which yielded p<.001. Colonoscopies performed after the requirement change tended to have a higher incidence and greater severity of polyps. From pre-2003 to post-2003 the percentage of colonoscopy procedures yielding no polyps decreased from 83.77% to 74.70%. Not only did post-2003 procedures yield more polyp findings, but the polyps recorded were more often of severe pathology. Before 2003 3.62% of colonoscopy findings were polyps of the hyperplastic type (the least severe polyp type) and only 3.35% were of greater severity. Post-2003, 4.21% of findings were hyperplastic polyps while 11.44% were of greater severity. Upon the investigation of other possible contributing factors to these results, we also found that mean age post-2003 was 54.55 years which was significantly higher than during the pre-2003 timeframe (47.32 years). This was observed with a one-sided Wilcoxon rank sum test, resulting in a p<0.001. The increased average age of astronauts could also be a contributing factor to the greater number of polyps found since the risk of developing polyps increases with age. Further work is needed to better understand the increased incidence and greater severity of polyps found in astronaut colonoscopy outcomes.

Masterova, K.↗

User's guide for the Nimbus 7 ERB Solar Analysis Tape (ESAT)

Five years of Nimbus 7 ERB solar data is available in compact form on a single ERB solar analysis tape (ESAT). The period covered is November 16, 1978 through October 31, 1983. The Nimbus 7 satellite performs just under 14 orbits a day and the ERB solar telescope observe the Sun once per orbit as the satellite passes + or - near the south pole. The data were carefully calibrated and screened. Mean orbital and daily values are given for the total solar irradiance plus selected spectral intervals. In addition, selected solar activity indicators are on the tape. The ERB experiment, the solar data calibration and screening procedures, the solar activity indicators, and the tape format are described briefly.

Hickey, J. R.↗

Integrated chronostratigraphy of Proterozoic-Cambrian boundary beds in the western Anabar region, northern Siberia

Carbonate-rich sedimentary rocks of the western Anabar region, northern Siberia, preserve an exceptional record of evolutionary and biogeochemical events near the Proterozoic/Cambrian boundary. Sedimentologically, the boundary succession can be divided into three sequences representing successive episodes of late transgressive to early highstand deposition; four parasequences are recognized in the sequence corresponding lithostratigraphically to the Manykal Formation. Small shelly fossils are abundant and include many taxa that also occur in standard sections of southeastern Siberia. Despite this coincidence of faunal elements, biostratigraphic correlations between the two regions have been controversial because numerous species that first appear at or immediately above the basal Tommotian boundary in southeastern sections have first appearances scattered through more than thirty metres of section in the western Anabar. Carbon- and Sr-isotopic data on petrographically and geochemically screened samples collected at one- to two-metre intervals in a section along the Kotuikan River, favour correlation of the Staraya Reckha Formation and most of the overlying Manykai Formation with sub-Tommotian carbonates in southeastern Siberia. In contrast, isotopic data suggest that the uppermost Manykai Formation and the basal 26 m of the unconformably overlying Medvezhya Formation may have no equivalent in the southeast; they appear to provide a sedimentary and palaeontological record of an evolutionarily significant time interval represented in southeastern Siberia only by the sub-Tommotian unconformity. Correlations with radiometrically dated horizons in the Olenek and Kharaulakh regions of northern Siberia suggest that this interval lasted approximately three to six million years, during which essentially all 'basal Tommotian' small shelly fossils evolved.

Non-NASA Center↗

Know Your Enemy - Implementation of Bioremediation within a Suspected DNAPL Source Zone Following High-Resolution Site Characterization at Contractors Road Heavy Equipment Area, Kennedy Space Center, Florida

The National Aeronautics and Space Administration (NASA), Kennedy Space Center (KSC), has adopted high-resolution site characterization (HRSC) sampling techniques during baseline sampling prior to implementation of remedies to confirm and refine the conceptual site model (CSM). HRSC sampling was performed at Contractors Road Heavy Equipment Area (CRHE) prior to bioremediation implementation to verify the extent of the trichloroethene (TCE) dense non-aqueous phase liquid (DNAPL) source area (defined as the area with TCE concentrations above 1% solubility) and its daughter product dissolved plume that had been identified during previous HRSC events. The results of HRSC pre-bioremediation implementation sampling suggested that the TCE source area was larger than originally identified during initial site characterization activities, leading to a design refinement to improve electron donor distribution and increase the likelihood of achieving remedial objectives. Approach/Activities: HRSC was conducted from 2009 through 2014 to delineate the vertical and horizontal extent of chlorinated volatile organic compounds (CVOCs) in the groundwater. Approximately 2,340 samples were collected from 363 locations using direct push technology (DPT) groundwater sampling techniques. Samples were collected from up to 14 depth intervals at each location using a 4-foot sampling screen. This HRSC approach identified a narrow (approx. 5 to 30 feet wide), approximately 3,000 square foot TCE DNAPL source area (maximum detected TCE concentration of 160,000 micrograms per liter [micro-g/L] at DPT sampling location DPT0225). Prior to implementation of a bioremediation interim measure, HRSC baseline sampling was conducted using DPT groundwater sampling techniques. Concentrations of TCE were an order of magnitude lower than previous reported (12,000 micro-g/L maximum at DPT sampling location DPT0225) at locations sampled adjacent to previous sampling locations. To further evaluate the variability in concentrations observed additional sampling was conducted in 2016. The results identified higher concentrations than originally detected within the previously defined source area and the presence of source zone concentrations upgradient of the previously defined source area (maximum concentration observed 570,000 micro-g/L). The HRSC baseline sampling data allowed for a revision of the bioremediation design prior to implementation. Bioremediation was implemented within the eastern portion of the source area in November and December 2016 and quarterly performance monitoring was completed in March and June 2017. Reductions in CVOC concentrations from baseline were observed at all performance monitoring wells in the treatment area, and by June 2017, an approximate 95% CVOC mass reduction was observed based on monitoring well sampling results. Results/Lessons Learned: The results of this project suggest that, due to the complexity of DNAPL source zones, HRSC during pre-implementation baseline sampling in the TCE source zone was an essential strategy for verifying the treatment area and depth prior to remedy implementation. If the upgradient source zone mass was not identified prior to bioremediation implementation, the mass would have served as a long-term source for the dissolved plume.

Chrest, Anne↗

A Machine Learning Approach to Predict Martensitic Transition Temperatures for Shape Memory Alloys

Shape memory alloys (SMAs) are a unique class of materials with several remarkable properties including shape recovery, superelasticity, etc. Especially important for many NASA applications is the ability to tune the martensitic phase transition temperature by varying the alloy composition. Nickel-titanium (NiTi) based alloys are the most widely studied of this class, with compositions involving ternary, quaternary, or higher additions being considered. Over the past several years, a significant database of SMA properties has been assembled by NASA researchers. Such a database is ideal for data science-based approaches including machine learning. We present results from a developed machine learning model capable of accurately predicting the transition temperature of SMAs across a wide range of compositions. Our model has the added benefit of interpretability and even provides confidence intervals for our predictions. This model will make rapid screening and design of new SMA materials possible. Predictions from the machine learning model can be validated by empirical and/or atomistic scale modeling.

Shreyas Honrao↗

The lithium-like 2s 2S-2p 2P transition in solar flares

Accurate wavelengths of the Fe XXIV lithium-like doublet at 192 and 255 A are derived from measurements made in a sample of four solar flares observed with a spectroheliograph aboard Skylab and selected to minimize systematic effects. The mean value of the Fe XXIV doublet interval is determined, and new members of the lithium isoelectronic sequence are identified, including Cr XXII, Mn XXIII, and Ni XXVI. Doublet splitting along the lithium sequence is analyzed in terms of the experimental screening factor, it is found that the doublet separations increase smoothly with charge number along the sequence, and the doublet interval in Ni XXVI is accurately extrapolated. The experimental screening factors are compared with the values predicted by Snyder's (1971) relativistic screening theory, and excellent agreement is found.

Widing, K. G.↗

Patterns and Timing of Initial Relapse in Patients Subsequently Undergoing Transplantation for Hodgkin's Lymphoma

Purpose: To evaluate the patterns and timing of initial recurrence in patients with Hodgkin's lymphoma (HL) who subsequently underwent high-dose chemotherapy with autologous stem cell transplantation to enhance our understanding of the natural history of this disease and its modern treatment strategies and to direct approaches to disease surveillance. Methods and Materials: The records of 69 patients with HL who had undergone high-dose chemotherapy with autologous stem cell transplantation in our center between May 1992 and June 2006 were analyzed. The initial diagnosis had been made between April 1982 and January 2005 at a median patient age of 33 years (range, 19-65). The patients were segregated according to the initial stage (Stage I-II vs. III-IV). Results: Early-stage HL patients developed a relapse at a median of 2.1 years (range, 0.5-10.3), with 91% of relapses at the initial disease site, 71% of which (65% overall) were only in previously involved sites. Advanced-stage HL patients developed a relapse at a median of 1.5 years (range, 0.6-10.5), with 97% at the initial site, 71% of which (69% overall) were only in previously involved sites. Single-site relapses occurred in 47% of early- vs. 26% of advanced-stage patients, and extranodal relapses occurred in 12% of early- vs. 31% of advanced-stage patients. Conclusions: Almost all patients with HL who develop relapse and subsequently undergo high-dose chemotherapy with autologous stem cell transplantation initially developed recurrence in previously involved disease sites. Early-stage HL relapses often occurred in single sites, and advanced-stage disease relapses were more likely in multiple and extranodal sites. The interval to recurrence was brief, suggesting that the frequency of screening should be the greatest in the early post-therapy years.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Identification of quaternary ammonium compounds as potent inhibitors of hERG potassium channels

The human ether-a-go-go-related gene (hERG) channel, a member of a family of voltage-gated potassium (K{sup +}) channels, plays a critical role in the repolarization of the cardiac action potential. The reduction of hERG channel activity as a result of adverse drug effects or genetic mutations may cause QT interval prolongation and potentially leads to acquired long QT syndrome. Thus, screening for hERG channel activity is important in drug development. Cardiotoxicity associated with the inhibition of hERG channels by environmental chemicals is also a public health concern. To assess the inhibitory effects of environmental chemicals on hERG channel function, we screened the National Toxicology Program (NTP) collection of 1408 compounds by measuring thallium influx into cells through hERG channels. Seventeen compounds with hERG channel inhibition were identified with IC{sub 50} potencies ranging from 0.26 to 22 {mu}M. Twelve of these compounds were confirmed as hERG channel blockers in an automated whole cell patch clamp experiment. In addition, we investigated the structure-activity relationship of seven compounds belonging to the quaternary ammonium compound (QAC) series on hERG channel inhibition. Among four active QAC compounds, tetra-n-octylammonium bromide was the most potent with an IC{sub 50} value of 260 nM in the thallium influx assay and 80 nM in the patch clamp assay. The potency of this class of hERG channel inhibitors appears to depend on the number and length of their aliphatic side-chains surrounding the charged nitrogen. Profiling environmental compound libraries for hERG channel inhibition provides information useful in prioritizing these compounds for cardiotoxicity assessment in vivo.

60 APPLIED LIFE SCIENCES↗

Nimbus-7 ERB Solar Analysis Tape (ESAT) user's guide

Seven years and five months of Nimbus-7 Earth Radiation Budget (ERB) solar data are available on a single ERB Solar Analysis Tape (ESAT). The period covered is November 16, 1978 through March 31, 1986. The Nimbus-7 satellite performs approximately 14 orbits per day and the ERB solar telescope observes the sun once per orbit as the satellite crosses the southern terminator. The solar data were carefully calibrated and screened. Orbital and daily mean values are given for the total solar irradiance plus other spectral intervals (10 solar channels in all). In addition, selected solar activity indicators are included on the ESAT. The ESAT User's Guide is an update of the previous ESAT User's Guide (NASA TM 86143) and includes more detailed information on the solar data calibration, screening procedures, updated solar data plots, and applications to solar variability. Details of the tape format, including source code to access ESAT, are included.

Major, Eugene↗

Changes in Liver Metabolic Gene Expression from Radiation Exposure

Radiation exposure is one of the unique physiological challenges of human spaceflight that is not encountered on earth. While radiation exposure is known to impart physiological stresses and alter normal function, it is unclear how it specifically affects drug metabolism. A major concern is that the actions of medications used in spaceflight may deviate from the expectations formed from terrestrial use. This concern was investigated at the molecular level by analyzing how gamma radiation exposure affected gene expression in the livers of mice. Three different doses of radiation were administered and after various intervals of recovery time, gene expression was measured with RT-qPCR screening arrays for drug metabolism and DNA repair. After examining the results of 192 genes total from each of 72 mice, 65 genes were found to be significantly affected by at least one of the doses of radiation. In general, the genes affected are involved in the metabolism of drugs with lipid or steroid hormone-like structures, as well as the maintenance of redox homeostasis and repair of DNA damage.

Peters, C. P.↗

Towards in-situ high precision local material velocity measurements in lattice materials under dynamic compression

The study of dynamic compression of materials requires high precision spatial and temporal resolution to infer the material state at any given time. In ultra-fast imaging experiments such as those performed at the Dynamic Compression Sector at the Advanced Photon Source, the current CCD frame rate is less than the X-ray pulse rate necessitating that 4 CCDs be used to image a single scintillator screen to obtain the same projection of transmitted or diffracted beam at time intervals synchronized with the X-ray beam. The use of multiple-camera setups is often employed for a variety of reasons including enhancing the temporal resolution through interleaving frames or increasing the number of viewpoints, for example. Physical corrections are made to have each CCD approximately viewing the same field of view, however we present corrections that can be made after the data collection to further refine and be able to compare movements and changes in the sample between independent CCDs. These software corrections enable higher precision and higher fidelity comparison of position changes due to sample deformation. Furthermore, we present a method to correct images (or frames) as a demonstration toward high fidelity displacement measurements in these types of ultra-fast multi-camera setup experiments.

36 MATERIALS SCIENCE↗

Phase Space Reconstruction from Accelerator Beam Measurements Using Neural Networks and Differentiable Simulations

Characterizing the phase space distribution of particle beams in accelerators is a central part of accelerator understanding and performance optimization. However, conventional reconstruction-based techniques either use simplifying assumptions or require specialized diagnostics to infer high-dimensional (> $2D$) beam properties. In this Letter, we introduce a general-purpose algorithm that combines neural networks with differentiable particle tracking to efficiently reconstruct high-dimensional phase space distributions without using specialized beam diagnostics or beam manipulations. Furthermore, we demonstrate that our algorithm accurately reconstructs detailed 4D phase space distributions with corresponding confidence intervals in both simulation and experiment using a single focusing quadrupole and diagnostic screen. This technique allows for the measurement of multiple correlated phase spaces simultaneously, which will enable simplified 6D phase space distribution reconstructions in the future.

47 OTHER INSTRUMENTATION↗

Compensatory mitigation and screening rules in environmental impact assessment

Concerns about the effectiveness of environmental impact assessment (EIA) have prompted proposals to improve its performance by limiting the discretion of decision-makers in screening. To investigate whether such proposals are likely to generate the desired results, we conducted an evaluation of the screening process under the Australian government's EIA regime from its introduction on 16 July 2000 to 30 June 2013 (study period). Almost 1 in 5 ‘particular manner’ decisions—a type of screening decision under the regime—were found to be unlawful. The extent of non-compliance is explained on the basis of convenience. The department was required to assess a large number of projects under tight timeframes and with limited resources, while being pressured by proponents to allow their projects to bypass EIA. These pressures resulted in the development of an informal custom whereby the formal compensatory mitigation restrictions were frequently ignored. The results highlight the relative significance of formal and informal institutions in EIA. Formal EIA rules typically provide a mere outline of the process. The informal institutions adopted by administrators often have a greater influence on how the process operates and what it achieves. - Highlights: • Concerns about the effectiveness of environmental impact assessment (EIA) have prompted proposals to improve its performance by limiting the discretion of decision-makers in screening. • To investigate whether such proposals are likely to generate the desired results, we conducted an evaluation of the Australian government's screening process, looking at the extent of compliance with a formal prohibition on the consideration of compensatory mitigation. • Almost 1 in 5 ‘particular manner’ decisions – a type of screening decision under the regime – were found to be unlawful (with a 95% confidence interval of between 1:4 and 1:7) because of a failure to abide by the compensatory mitigation restrictions. For urban development actions, the ratio between lawful and unlawful particular manner decisions was worse than 1:1. • The extent of non-compliance is explained on the basis of convenience. Budget and interest group pressures resulted in the development of an informal custom whereby the formal compensatory mitigation restrictions were ignored. • The results highlight the relative significance of formal and informal institutions in EIA. Formal EIA rules typically provide a mere outline of the process. The informal institutions adopted by administrators often have a greater influence on how the process operates and what it achieves.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dynamic Contrast-Enhanced MRI of Cervical Cancers: Temporal Percentile Screening of Contrast Enhancement Identifies Parameters for Prediction of Chemoradioresistance

Purpose: To systematically screen the tumor contrast enhancement of locally advanced cervical cancers to assess the prognostic value of two descriptive parameters derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). Methods and Materials: This study included a prospectively collected cohort of 81 patients who underwent DCE-MRI with gadopentetate dimeglumine before chemoradiotherapy. The following descriptive DCE-MRI parameters were extracted voxel by voxel and presented as histograms for each time point in the dynamic series: normalized relative signal increase (nRSI) and normalized area under the curve (nAUC). The first to 100th percentiles of the histograms were included in a log-rank survival test, resulting in p value and relative risk maps of all percentile-time intervals for each DCE-MRI parameter. The maps were used to evaluate the robustness of the individual percentile-time pairs and to construct prognostic parameters. Clinical endpoints were locoregional control and progression-free survival. The study was approved by the institutional ethics committee. Results: The p value maps of nRSI and nAUC showed a large continuous region of percentile-time pairs that were significantly associated with locoregional control (p < 0.05). These parameters had prognostic impact independent of tumor stage, volume, and lymph node status on multivariate analysis. Only a small percentile-time interval of nRSI was associated with progression-free survival. Conclusions: The percentile-time screening identified DCE-MRI parameters that predict long-term locoregional control after chemoradiotherapy of cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of viewing distance on the generation of vertical eye movements during locomotion

Vertical head and eye coordination was studied as a function of viewing distance during locomotion. Vertical head translation and pitch movements were measured using a video motion analysis system (Optotrak 3020). Vertical eye movements were recorded using a video-based pupil tracker (Iscan). Subjects (five) walked on a linear treadmill at a speed of 1.67 m/s (6 km/h) while viewing a target screen placed at distances ranging from 0.25 to 2.0 m at 0. 25-m intervals. The predominant frequency of vertical head movement was 2 Hz. In accordance with previous studies, there was a small head pitch rotation, which was compensatory for vertical head translation. The magnitude of the vertical head movements and the phase relationship between head translation and pitch were little affected by viewing distance, and tended to orient the naso-occipital axis of the head at a point approximately 1 m in front of the subject (the head fixation distance or HFD). In contrast, eye velocity was significantly affected by viewing distance. When viewing a far (2-m) target, vertical eye velocity was 180 degrees out of phase with head pitch velocity, with a gain of 0. 8. This indicated that the angular vestibulo-ocular reflex (aVOR) was generating the eye movement response. The major finding was that, at a close viewing distance (0.25 m), eye velocity was in phase with head pitch and compensatory for vertical head translation, suggesting that activation of the linear vestibulo-ocular reflex (lVOR) was contributing to the eye movement response. There was also a threefold increase in the magnitude of eye velocity when viewing near targets, which was consistent with the goal of maintaining gaze on target. The required vertical lVOR sensitivity to cancel an unmodified aVOR response and generate the observed eye velocity magnitude for near targets was almost 3 times that previously measured. Supplementary experiments were performed utilizing body-fixed active head pitch rotations at 1 and 2 Hz while viewing a head-fixed target. Results indicated that the interaction of smooth pursuit and the aVOR during visual suppression could modify both the gain and phase characteristics of the aVOR at frequencies encountered during locomotion. When walking, targets located closer than the HFD (1.0 m) would appear to move in the same direction as the head pitch, resulting in suppression of the aVOR. The results of the head-fixed target experiment suggest that phase modification of the aVOR during visual suppression could play a role in generating eye movements consistent with the goal of maintaining gaze on targets closer than the HFD, which would augment the lVOR response.

NASA Discipline Neuroscience↗

Investigation of temperature dependence of neutron yield and electron screening potential for the d(d, n){sup 3}He reaction proceeding in deuterides ZrD{sub 2} and TiD{sub 2}

The temperature dependence of the enhancement factor for the dd reaction proceeding in TiD{sub 2} and ZrD{sub 2} is investigated. The experiments were carried out at the Hall pulsed ion accelerator (INP, Polytechnic University, Tomsk, Russia) in the deuteron energy interval 7.0-12.0 keV and at temperatures ranging from 20 to 200 Degree-Sign C. The values obtained for the electron screening potentials indicate that the dd reaction enhancement factor does not depend on the target temperature in the range 20-200 Degree-Sign C. This result contradicts the conclusions drawn by the LUNA Collaboration from their work.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of radiographers’ mammography screen-reading accuracy in Australia

This study aimed to evaluate the accuracy of radiographers’ screen-reading mammograms. Currently, radiologist workforce shortages may be compromising the BreastScreen Australia screening program goal to detect early breast cancer. The solution to a similar problem in the United Kingdom has successfully encouraged radiographers to take on the role as one of two screen-readers. Prior to consideration of this strategy in Australia, educational and experiential differences between radiographers in the United Kingdom and Australia emphasise the need for an investigation of Australian radiographers’ screen-reading accuracy. Ten radiographers employed by the Westmead Breast Cancer Institute with a range of radiographic (median = 28 years), mammographic (median = 13 years) and BreastScreen (median = 8 years) experience were recruited to blindly and independently screen-read an image test set of 500 mammograms, without formal training. The radiographers indicated the presence of an abnormality using BI-RADS®. Accuracy was determined by comparison with the gold standard of known outcomes of pathology results, interval matching and client 6-year follow-up. Individual sensitivity and specificity levels ranged between 76.0% and 92.0%, and 74.8% and 96.2% respectively. Pooled screen-reader accuracy across the radiographers estimated sensitivity as 82.2% and specificity as 89.5%. Areas under the reading operating characteristic curve ranged between 0.842 and 0.923. This sample of radiographers in an Australian setting have adequate accuracy levels when screen-reading mammograms. It is expected that with formal screen-reading training, accuracy levels will improve, and with support, radiographers have the potential to be one of the two screen-readers in the BreastScreen Australia program, contributing to timeliness and improved program outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

FIM Avionics Operations Manual

This document describes the operation and use of the Flight Interval Management (FIM) Application installed on an electronic flight bag (EFB). Specifically, this document includes: 1) screen layouts for each page of the interface; 2) step-by-step instructions for data entry, data verification, and input error correction; 3) algorithm state messages and error condition alerting messages; 4) aircraft speed guidance and deviation indications; and 5) graphical display of the spatial relationships between the Ownship aircraft and the Target aircraft.

Alves, Erin E.↗