Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensor array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Design and Implementation of a Hall Effect Sensor Array Applied to Recycling Hard Drive Magnets

Rare earths are an important resource for many electronic components and technologies. Examples abound including Neodymium magnets used in mobile devices and computer hard drives (HDDs), and a variety of renewable energy technologies (e.g., wind turbines). Approximately 21,000 metric tons of Neodymium is processed annually with less than 1% being recycled. An economic system to assist in the recycling of magnet material from post-consumer goods, such as Neodymium Iron Boron magnets commonly found in hard drives is presented. A central component of this recycling measurement system uses an array of 128 Hall Effect sensors arranged in two columns to detect the magnetic flux lines orthogonal to the HDD. Results of using the system to scan planar shaped objects such as hard drives to identify and spatially locate rare-earth magnets for removal and recycling from HDDs are presented. Applications of the sensor array in other identification and localization of magnetic components and assemblies will be presented.

Hall Effect sensors↗

Multiple-angle observations of reflectance anisotropy from an airborne linear array sensor

An airborne pointable imaging multispectral linear array sensor has been developed for the multidirectional observation of surface reflectance anisotropy. The sensor design permits observations up to 45 deg off-nadir in three spectral bands (green, red, and near-infrared). Calibration permits the conversion of sensor data to radiance units with an absolute uncertainty of 6 percent. Observations of five field plots from seven view directions are discussed. Calibration and atmospheric corrections are used to derive hemispherical-directional reflectance factors. A three-term reflectance model is fit to the reflectance factors for each plot to represent the continuous distribution of reflectance factors with view direction. The reflectance model is integrated over all view directions to calculate bihemispherical reflectance factors. The calculated bihemispherical factors differed by 1 to 25 percent from values based on an assumption of isotropic reflectance depending on spectral band and field plot. These calculations demonstrate the technologic and scientific capabilities required for the remote characterization of surface reflectance anisotropy. Remote multidirectional observations are both feasible and needed to fully evaluate land reflectance characteristics.

Irons, James R.↗

Multi Sensor Array

This paper presents viewgraphs on the Multi Sensor Array. The topics include: 1) MSA Algorithm; 2) Types of Sensors for the MSA; 3) How to test the MSA; 4) Monte Carlo Simulation; and 5) Accelerated Life Tests.

Immer, Christopher↗

Information theory analysis of sensor-array imaging systems for computer vision

Information theory is used to assess the performance of sensor-array imaging systems, with emphasis on the performance obtained with image-plane signal processing. By electronically controlling the spatial response of the imaging system, as suggested by the mechanism of human vision, it is possible to trade-off edge enhancement for sensitivity, increase dynamic range, and reduce data transmission. Computational results show that: signal information density varies little with large variations in the statistical properties of random radiance fields; most information (generally about 85 to 95 percent) is contained in the signal intensity transitions rather than levels; and performance is optimized when the OTF of the imaging system is nearly limited to the sampling passband to minimize aliasing at the cost of blurring, and the SNR is very high to permit the retrieval of small spatial detail from the extensively blurred signal. Shading the lens aperture transmittance to increase depth of field and using a regular hexagonal sensor-array instead of square lattice to decrease sensitivity to edge orientation also improves the signal information density up to about 30 percent at high SNRs.

Huck, F. O.↗

Multifunctional potentiometric gas sensor array with an integrated temperature control and temperature sensors

Embodiments of the subject invention relate to a gas sensor and method for sensing one or more gases. An embodiment incorporates an array of sensing electrodes maintained at similar or different temperatures, such that the sensitivity and species selectivity of the device can be fine tuned between different pairs of sensing electrodes. A specific embodiment pertains to a gas sensor array for monitoring combustion exhausts and/or chemical reaction byproducts. An embodiment of the subject device related to this invention operates at high temperatures and can withstand harsh chemical environments. Embodiments of the device are made on a single substrate. The devices can also be made on individual substrates and monitored individually as if they were part of an array on a single substrate. The device can incorporate sensing electrodes in the same environment, which allows the electrodes to be coplanar and, thus, keep manufacturing costs low. Embodiments of the device can provide improvements to sensitivity, selectivity, and signal interference via surface temperature control.

42 ENGINEERING↗

Acoustic MEMS Sensor Array for Quench Detection of CICC Superconducting Cables

A novel quench detection method using microelectro- mechanical system (MEMS) sensor technology has been investigated in use for high temperature superconducting (HTS) conductors such REBCO tape cables. The sensor array along a superconducting cable, such as a cable-in-conduit-conductor (CICC), is installed in a cooling channel. It will allow sensitive and quick detection for a local quench of a superconducting cable. This work has confirmed that a quench of a single REBCO tape can be detected in liquid nitrogen by a MEMS piezoelectric microphone sensor. The quench detection design utilizing a MEMS sensor array method is discussed for the case of a toroidal field (TF) magnets of a fusion Tokamak device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Acoustic MEMS Sensor Array for Quench Detection of CICC Superconducting Cables

Here, a novel quench detection method using micro-electro-mechanical system (MEMS) sensor technology has been investigated in use for high temperature superconducting (HTS) conductors such REBCO tape cables. The sensor array along a superconducting cable, such as a cable-in-conduit-conductor (CICC), is installed in a cooling channel. It will allow sensitive and quick detection for a local quench of a superconducting cable. This work has confirmed that a quench of a single REBCO tape can be detected in liquid nitrogen by a MEMS piezoelectric microphone sensor. The quench detection design utilizing a MEMS sensor array method is discussed for the case of a toroidal field (TF) magnets of a fusion Tokamak device.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microfabricated Chemical Gas Sensors and Sensor Arrays for Aerospace Applications

Aerospace applications require the development of chemical sensors with capabilities beyond those of commercially available sensors. In particular, factors such as minimal sensor size, weight, and power consumption are particularly important. Development areas which have potential aerospace applications include launch vehicle leak detection, engine health monitoring, and fire detection. Sensor development for these applications is based on progress in three types of technology: 1) Micromachining and microfabrication (Microsystem) technology to fabricate miniaturized sensors; 2) The use of nanocrystalline materials to develop sensors with improved stability combined with higher sensitivity; 3) The development of high temperature semiconductors, especially silicon carbide. This presentation discusses the needs of space applications as well as the point-contact sensor technology and sensor arrays being developed to address these needs. Sensors to measure hydrogen, hydrocarbons, nitrogen oxides (NO,), carbon monoxide, oxygen, and carbon dioxide are being developed as well as arrays for leak, fire, and emissions detection. Demonstrations of the technology will also be discussed. It is concluded that microfabricated sensor technology has significant potential for use in a range of aerospace applications.

Hunter, Gary W.↗

Using sensor arrays to decode NO x /NH 3 /C 3 H 8 gas mixtures for automotive exhaust monitoring

In this work, an array of four mixed-potential sensors is employed to identify and quantify gases in complex mixtures of unknown composition which mimic diesel engine exhaust. The sensors use dense metal and metal oxide electrodes with a porous ceramic electrolyte, yttria-stabilized zirconia (YSZ). Since the sensors exhibit cross-specificity toward target gases, we develop a computational model for predicting gas concentrations in the mixtures. Our model is based on fundamental principles of gas-sensor interactions and, furthermore, takes into account the non-linearity of the observed sensor voltage response. Our approach enables accurate predictions of gas concentrations from the voltage output of the sensor array exposed to an extensive set of mixtures involving C 3 H 8 , NH 3 , NO and NO 2 . We find that our predictions remain accurate even if the model is trained using a reduced set of mixtures, or if the number of sensors is decreased to three or two. Finally, our experimental and computational framework can be used to decipher contents of complex gas mixtures of unknown composition in numerous industrial, automotive, and national security settings.

47 OTHER INSTRUMENTATION↗

TDD LoRa and Delta Encoding in Low-Power Networks of Environmental Sensor Arrays for Temperature and Deformation Monitoring

Abstract Densely distributed sensor networks can revolutionize environmental observations by providing real-time data with an unprecedented spatiotemporal resolution. However, field deployments often pose unique challenges in terms of power provisions and wireless connectivity. We present a framework for wirelessly connected distributed sensor arrays for near-surface temperature and/or deformation monitoring. Our research focuses on a novel time division duplex implementation of the LoRa protocol, enabling battery powered base stations and avoiding collisions within the network. In order to minimize transmissions and improve battery life throughout the network, we propose a dedicated delta encoding algorithm that utilizes the spatial and temporal similarity in the acquired data sets. We implemented the developed technologies in a AA battery powered hardware platform that can be used as a wireless data logger or base station, and we conducted an assessment of the power consumption. Without data compression, the projected battery life for a data logger is 4.74 years, and a wireless base stations can last several weeks or months depending on the amount of network traffic. The delta encoding algorithm can further improve this battery life with a factor of up to 3.50. Our results demonstrate the viability of the proposed methods for low-power environmental wireless sensor networks.

54 ENVIRONMENTAL SCIENCES↗

Photo sensor array technology development

The development of an improved capability photo sensor array imager for use in a Viking '75 type facsimile camera is presented. This imager consists of silicon photodiodes and lead sulfide detectors to cover a spectral range from 0.4 to 2.7 microns. An optical design specifying filter configurations and convergence angles is described. Three electronics design approaches: AC-chopped light, DC-dual detector, and DC-single detector, are investigated. Experimental and calculated results are compared whenever possible using breadboard testing and tolerance analysis techniques. Results show that any design used must be forgiving of the relative instability of lead sulfide detectors. A final design using lead sulfide detectors and associated electronics is implemented by fabrication of a hybrid prototype device. Test results of this device show a good agreement with calculated values.

Rossman, M. W.↗

Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis

We report that wearable sensor technologies are essential to the realization of personalized medicine through continuously monitoring an individual’s state of health. Sampling human sweat, which is rich in physiological information13, could enable non-invasive monitoring. Previously reported sweat-based and other noninvasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state14–18. Given the complexity of sweat secretion, simultaneous and multiplexed screening of target biomarkers is critical and requires full system integration to ensure the accuracy of measurements. Here we present a mechanically flexible and fully integrated (that is, no external analysis is needed) sensor array for multiplexed in situ perspiration analysis, which simultaneously and selectively measures sweat metabolites (such as glucose and lactate) and electrolytes (such as sodium and potassium ions), as well as the skin temperature (to calibrate the response of the sensors). Lastly, our work bridges the technological gap between signal transduction, conditioning (amplification and filtering), processing and wireless transmission in wearable biosensors by merging plasticbased sensors that interface with the skin with silicon integrated circuits consolidated on a flexible circuit board for complex signal processing.

47 OTHER INSTRUMENTATION↗

A Triboelectric Sensor Array for Electrostatic Studies on the Lunar Surface

The moons electrostatic environment requires careful consideration in the development of future lunar landers. Electrostatically charged dust was well documented during the Apollo missions to cause thermal control, mechanical, and visibility issues. The fine dust particles that make up the surface are electrostatically charged as a result of numerous charging mechanisms. The relatively dry conditions on the moon creates a prime tribocharging environment during surface operations. The photoelectric effect is dominant for lunar day static charging, while plasma electrons are the main contributor for lunar night electrostatic effects. Electrostatic charging is also dependent on solar intensity, Earth-moon relative positions, and cosmic ray flux. This leads to a very complex and dynamic electrostatic environment that must be studied for the success of long term lunar missions.In order to better understand the electrostatic environment of planetary bodies, Kennedy Space Center, in previous collaboration with the Jet Propulsion Laboratory, has developed an electrostatic sensor suite. One of the instruments included in this package is the triboelectric sensor array. It is comprised of strategically selected materials that span the triboelectric series and that also have previous spaceflight history. In this presentation, we discuss detailed testing with the triboelectric sensor array performed at Kennedy Space Center. We will discuss potential benefits and use cases of this low mass, low cost sensor package, both for science and for mission success.

Charging↗

Thermal microphotonic sensor and sensor array

A thermal microphotonic sensor is disclosed for detecting infrared radiation using heat generated by the infrared radiation to shift the resonant frequency of an optical resonator (e.g. a ring resonator) to which the heat is coupled. The shift in the resonant frequency can be determined from light in an optical waveguide which is evanescently coupled to the optical resonator. An infrared absorber can be provided on the optical waveguide either as a coating or as a plate to aid in absorption of the infrared radiation. In some cases, a vertical resonant cavity can be formed about the infrared absorber to further increase the absorption of the infrared radiation. The sensor can be formed as a single device, or as an array for imaging the infrared radiation.

47 OTHER INSTRUMENTATION↗

Differential temperature stress measurement employing array sensor with local offset

The instrument has a focal plane array of infrared sensors of the integrating type such as a multiplexed device in which a charge is built up on a capacitor which is proportional to the total number of photons which that sensor is exposed to between read-out cycles. The infrared sensors of the array are manufactured as part of an overall array which is part of a micro-electronic device. The sensor achieves greater sensitivity by applying a local offset to the output of each sensor before it is converted into a digital word. The offset which is applied to each sensor will typically be the sensor's average value so that the digital signal which is periodically read from each sensor of the array corresponds to the portion of the signal which is varying in time. With proper synchronization between the cyclical loading of the test object and the frame rate of the infrared array the output of the A/D converted signal will correspond to the stress field induced temperature variations. A digital lock-in operation may be performed on the output of each sensor in the array. This results in a test instrument which can rapidly form a precise image of the thermoelastic stresses in an object.

Lesniak, Jon R.↗

Fabrication of thermal microphotonic sensors and sensor arrays

A thermal microphotonic sensor is fabricated on a silicon substrate by etching an opening and a trench into the substrate, and then filling in the opening and trench with silicon oxide which can be deposited or formed by thermally oxidizing a portion of the silicon substrate surrounding the opening and trench. The silicon oxide forms a support post for an optical resonator which is subsequently formed from a layer of silicon nitride, and also forms a base for an optical waveguide formed from the silicon nitride layer. Part of the silicon substrate can be selectively etched away to elevate the waveguide and resonator. The thermal microphotonic sensor, which is useful to detect infrared radiation via a change in the evanescent coupling of light between the waveguide and resonator, can be formed as a single device or as an array.

Shaw, Michael J↗