Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensor fault”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Development of a Annual Air Handling Unit Fault Dataset for FDD Tools: Lessons Learned and Considerations for FDD Developers

As energy management and information systems (e.g., automated fault detection and diagnostics [AFDD] tools) become more prevalent in the commercial building stock, it is important to determine the effectiveness of these technologies by benchmarking their performance. The authors have been working to develop the largest publicly available dataset of HVAC fault data for performance benchmarking applications, covering the most common HVAC systems and designs including chiller plants, rooftop packaged units, dual duct air handling units and single duct air handling units. This study covers the development, modeling, and validation of a synthetic fault dataset for a single duct air handling unit (AHU), one of the most common HVAC configurations found in the commercial building stock. Despite this being a common system, real-world time series data are scarce and usually do not span a wide range of weather conditions. Due to this limitation, a detailed AHU model was employed to carry out annual simulations of numerous common sensor and mechanical faults, which were then validated by comparing their effects on system performance to expected symptoms. We summarize the nature of each fault and their impacts under different weather and operation conditions. Finally, we highlight considerations for FDD developers that may want to use this dataset to assess their algorithms’ performance and their improvement over time.

Casillas, Armando↗

Advanced Sensor Deployment for Distribution System State Estimation and Fault Identification: Preprint

Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs)at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases - distribution system state estimation (DSSE) and fault identification - are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.

distribution system monitoring↗

Air Conditioning Systems Fault Detection and Diagnosis-Based Sensing and Data-Driven Approaches

The air conditioning (AC) system is the primary building end-use contributor to the peak demand for energy. The energy consumed by this system has grown as fast as it has in the last few decades, not only in the residential section but also in the industry and transport sectors. Therefore, to combat energy crises, urgent actions on energy efficiency should be taken to support energy security. Consequently, the faults in AC system components increase energy consumption due to the degradation of the system’s performance and the losses in the energy conversion procedure. In this work, AC system fault detection and diagnosis (FDD) methods are investigated to propose analytic tools to identify faults and provide solutions to those problems. The analysis of existing work shows that data-driven approaches are more accurate for both soft and hard fault detection and diagnosis in AC systems. Therefore, the proposed methods are not accurate for simultaneous fault detection, while in some works, authors tested the method with several faults separately without investigating scenarios that combine more than one fault. Moreover, this study shows that integrating data-driven approaches requires deploying an optimal sensing and measurement architecture that can detect a maximum number of faults with minimally deployed sensors. The new sensing, information, and communication technologies are discussed for their integration in AC system monitoring in order to optimize system operation and detect faults.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Virtual Pressure Sensor for Electronic Expansion Valve Control in a Vapor Compression Refrigeration System

Virtual sensor technology, which uses simulation models/algorithms to calculate a value to represent an unmeasured variable or replace a directly measured reading, has attracted many studies in the heating, ventilation, air conditioning and refrigeration (HVAC&R) industry. However, most virtual sensor technologies are developed for fault detection and diagnostics (FDD) purposes, which generally compare the virtual sensor values with actual measured values to detect if any fault occurred and identify the causes that led to the fault. It is rare to see studies focus on control performance of virtual sensors after substituting an actual sensor. This is particularly important for the system with no redundant sensor since a virtual sensor is the most effective way to operate the system in the desirable region when any sensor failure occurs. To address this gap, this paper develops a new virtual pressure sensor technology to substitute the actual pressure measurement for electronic expansion valve (EXV) control in a vapor compression refrigeration system by integrating compressor and valve characteristics. The control performance of this proposed virtual pressure sensor technology under various operating conditions is validated with experimental data. Closed loop EXV control simulations with the proposed virtual pressure sensor are conducted, and the results are analyzed.

47 OTHER INSTRUMENTATION↗

Continuous operation of a coherent 3,000-qubit system

Neutral atoms are a promising platform for quantum science, enabling advances in areas ranging from quantum simulations and computation to metrology, atomic clocks and quantum networking. Although atom losses typically limit these systems to a pulsed mode, continuous operation could substantially enhance cycle rates, remove bottlenecks in metrology and enable deep-circuit quantum evolution through quantum error correction. Here we demonstrate an experimental architecture for high-rate reloading and continuous operation of a large-scale atom-array system while realizing coherent storage and manipulation of quantum information. Our approach utilizes a series of two optical lattice conveyor belts to transport atom reservoirs into the science region, where atoms are repeatedly extracted into optical tweezers without affecting the coherence of qubits stored nearby. Using a reloading rate of 300,000 atoms in tweezers per second, we create over 30,000 initialized qubits per second, which we leverage to assemble and maintain an array of over 3,000 atoms for more than 2 hours. Furthermore, we demonstrate persistent refilling of the array with atomic qubits in either a spin-polarized or a coherent superposition state while preserving the quantum state of stored qubits. Our results pave the way for the realization of large-scale continuously operated atomic clocks, sensors and fault-tolerant quantum computers.

atomic and molecular physics↗

Downhole Sensing and Event-Driven Sensor Fusion for Depth-of-Cut Based Autonomous Fault Response and Drilling Optimization

Achieving robust and efficient drilling is a critical part of reducing the cost of geothermal energy exploration and extraction. Drilling performance is often evaluated using one or more of three key metrics: depth of cut (DOC), rate of penetration (ROP), and mechanical specific energy (MSE). All three of these quantities are related to each other. DOC refers to the depth a bit penetrates into rock during drilling. This is an important quantity for estimating bit behavior. ROP is the simply the DOC multiplied by the rotational rate, and represents how quickly the drill bit is advancing through the ground. ROP is often the parameter used for drilling control and optimization. Finally, MSE provides insight into drilling efficiency and rock type. MSE calculations rely on ROP, drilling force, and drilling torque. Surface-based sensors at the top of the drill are often used to measure all these quantities. However, top-hole measurements can deviate substantially from the behavior at the bit due to lag, vibrations, and friction. Therefore, relying only on top-hole information can lead to suboptimal drilling control. In this work, we describe recent progress towards estimating ROP, DOC, and MSE using down-hole sensing. We assume down-hole measurements of torque, weight-on-bit (WOB). Our hypothesis is that these measurements can provide more rapid and accurate measures of drilling performance. We show how a multi-layer perceptron (MLP) machine learning algorithm can provide rapid and accurate performance when evaluated on experimental data taken from Sandia’s Hard Rock Drilling Facility. In addition, we implement our algorithms on an embedded system intended to emulate a bottom-hole-assembly for sensing and estimation. Our experimental results show that DOC can be estimated accurately and in real-time. These estimates when combined with measurements for rotary speed, torque, and force can provide improved estimates for ROP and MSE. These results have the potential to enable better drilling assessment, improved control, and extended component lifetimes.

15 GEOTHERMAL ENERGY↗

Barriers to Broader Utilization of Fault Detection Technologies for Improving Residential HVAC Equipment Efficiency

Faults in residential heating, ventilating, and air conditioning (HVAC) equipment may occur due to poor installation practices or develop over time, and these faults can negatively impact system efficiency, thermal comfort, and equipment lifespan. Automated fault detection and diagnostic (AFDD) technologies identify energy wasting HVAC faults, such as low indoor airflow and improper refrigerant charge, and guide technicians in improving system efficiency. For residential HVAC, AFDD consists of a range of fault detecting and diagnostic capabilities, sensor configurations, and target applications. AFDD technology can either be permanently installed by the original equipment manufacturer (OEM) using embedded sensors or as an add-on product either during or after installation. Additionally, several advanced installation tools and refrigerant gauge sets include AFDD features for temporary use during equipment installation and tune-ups. Some technologies can detect a fault but have limited diagnostic capabilities. For example, a single-point measurement from the home's thermostat or energy monitor can provide certain fault detection capability by analyzing the equipment runtime or energy consumption. These technologies, though limited at determining the cause of a given fault, may have significant energy savings potential due to their low cost and prevalence in the residential HVAC market. Despite the potential benefits, fault detection technologies face many technical and market barriers preventing broad adoption. Beyond the cost barriers due to the added sensor requirements and technology development, fault detection technologies face many implementation and adoption barriers such as installer training, customer awareness, standardized communication protocols, and methods of test for evaluating accuracy. The purpose of this whitepaper is to characterize market and technical barriers impeding broader utilization of fault detection technology for residential HVAC energy efficiency applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Implementation of Fault-Correction Algorithms in Fault Detection and Diagnostics Tools

A fault detection and diagnostics (FDD) tool is a type of energy management and information system that continuously identifies the presence of faults and efficiency improvement opportunities through a one-way interface to the building automation system and the application of automated analytics. Building operators on the leading edge of technology adoption use FDD tools to enable median whole-building portfolio savings of 8%. Although FDD tools can inform operators of operational faults, currently an action is always required to correct the faults to generate energy savings. A subset of faults, however, such as biased sensors, can be addressed automatically, eliminating the need for staff intervention. Automating this fault “correction” can significantly increase the savings generated by FDD tools and reduce the reliance on human intervention. Doing so is expected to advance the usability and technical and economic performance of FDD technologies. This paper presents the development of nine innovative fault auto-correction algorithms for Heating, Ventilation, and Air Conditioning pi(HVAC) systems. When the auto-correction routine is triggered, it overwrites control setpoints or other variables to implement the intended changes. It also discusses the implementation of the auto-correction algorithms in commercial FDD software products, the integration of these strategies with building automation systems and their preliminary testing.

field testing↗

Can We Fix It Automatically? Development of Fault Auto-Correction Algorithms for HVAC and Lighting Systems

A fault detection and diagnostics (FDD) tool is a type of energy management and information system designed to continuously identify the presence of faults and efficiency improvement opportunities through a one-way interface to the building automation system and application of automated analytics. Building owners and operators at the leading edge of technology adoption are using FDD tools to enable average whole-building portfolio savings of 8 percent. Although FDD tools can inform building operators of operational faults, currently a manual action is always required to correct faults and generate the associated energy savings. A subset of faults, however, such as biased sensors and manual override, can be addressed automatically, removing the need for operations and maintenance staff intervention. Automating this fault “correction” can significantly increase the savings generated by FDD tools and reduce the reliance on human intervention. Doing so is expected to advance the usability, as well as the technical and economic performance, of FDD technologies. In this paper, we present the development of 10 innovative fault auto-correction algorithms for HVAC and lighting systems. When the auto-correction routine is triggered, it will overwrite the control setpoints or other variables (via BACnet or other protocol) to implement the intended changes. These algorithms are able to automatically correct the faults or improve the operation associated with an incorrectly programmed schedule, override manual control, sensor bias, control hunting, rogue zone, and less aggressive setpoints/setpoints setback. The paper will also discuss the implementation of the auto-correction algorithms in FDD software products.

Lin, Guanjing↗

Digital Twin Enabling Technologies for Online Condition Monitoring of Nuclear Power Plant Components

Online condition monitoring is an area of active research that may enable improved scheduling, maintenance, and safety of nuclear power plant components, reducing unnecessary derate while simultaneously improving operational capacity. Digital twins are one avenue to conduct online condition monitoring and are currently being explored by national laboratories and universities alike. Digital twins for online condition monitoring are, in essence, state concurrent models that emulate a physical process which predicts a parameter and compares it against a measured value. However, digital twins may also provide additional insights by combining and interpreting various sources of information. These insights may be used for preventative maintenance scheduling optimization or early fault detection and are projected to be valuable for meeting requirements under 10 CFR 50.55a. However, digital twin technologies are still under significant development; quantifying model uncertainties, improving unique fault identification, and multimodal sensor fusion are some areas under investigation. Therefore, in this work, we discuss and review the various enabling technologies, in the form of advanced sensors, instrumentation, and modelling methods, that may be used to implement and enhance digital twins for online condition monitoring. A potential use case for pump-motors is presented to demonstrate how these various pieces of enabling digital twin technologies may integrated together for online condition monitoring. Challenges and opportunities associated with the pump-motor digital twin enabling technologies are also identified and discussed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Digital-Twin-Enabling Technologies for Online Condition Monitoring of Nuclear Power Plant Components

Online condition monitoring is an area of active research that may enable improved scheduling, maintenance, and safety of nuclear power plant components, reducing unnecessary derates while simultaneously improving operational capacity. Digital twins are one avenue to conduct online condition monitoring and are currently being explored by national laboratories and universities alike. Digital twins for online condition monitoring are, in essence, state concurrent models that emulate a physical process which predicts a parameter and compares it against a measured value. However, digital twins may also provide additional insights by combining and interpreting various sources of information. These insights may be used for preventative maintenance scheduling optimization or early fault detection and are projected to be valuable for meeting requirements under 10 CFR 50.55a. However, digital twin technologies are still under significant development; quantifying model uncertainties, improving unique fault identification, and multimodal sensor fusion are some areas under investigation. Therefore, in this work, we discuss and review the various enabling technologies, in the form of advanced sensors, instrumentation, and modelling methods, that may be used to implement and enhance digital twins for online condition monitoring. A potential use case for pump-motors is presented to demonstrate how these various pieces of enabling digital twin technologies may integrated together for online condition monitoring. Challenges and opportunities associated with the pump-motor digital twin enabling technologies are also identified and discussed.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Geomechanical in situ testing of fault reactivation in argillite repositories

Abstract. Pressurization of natural faults as a result of repository-induced effects can lead to their reactivation and permeability generation in case such features are present near disposal tunnels. Potential driving forces for such pressurization are the temperature increase caused by heat-producing high-level radioactive waste and the generation of hydrogen and other gases due to corrosion of engineered materials. We are primarily concerned about pressurization and fault activation in host rocks and faults that have very low natural permeability for pore pressure increases to dissipate, such as the argillite rocks currently investigated in Switzerland, France and other countries. This presentation discusses a series of in situ experiments of fault activation by fluid injection conducted in the argillite rock (Opalinus clay) at the Mont Terri underground research laboratory in Switzerland. A multi-model monitoring test bed was installed at Mont Terri that includes distributed fiber optics for strain, temperature, and acoustics; local fault pore pressure and three-dimensional displacement sensors; active seismic imaging; and passive seismic monitoring. The fault experiments (and their subsequent analysis via hydromechanical modeling) provide a new fundamental understanding of the coupling between pore pressure, fault deformation and permeability generation as a function of time and allow exploring how seismic and aseismic events may impact the integrity of faulted argillite host rock. Our experimental observations demonstrate that significant flow (and transport) can occur along the initially impermeable argillite fault when rupture is activated. However, the fault permeability decreases to almost its pre-activation value when fluid injection ceases and fluid pressure drops. Dilatant slip on the fault plane alone does not explain the observed increase in fault permeability; pressure-induced fault opening also plays a role, favored by the softness of the shale along with the fact that the structure of the fault zone prevents fluids from diffusing into the adjacent damage zone. Rupture initiation and permeability generation is initially aseismic, associated only with an increase in noise level and emerging tremors. Micro-earthquakes are initiated later in the experiments and typically occur away from the fluid-pressurized area. Hydromechanical models show that stress transferred from the initial aseismic deformation can build up to stress criticality and later induce seismic rupture. After presenting the experimental results, we will close the presentation with an outlook to future experimental campaigns using the fault test bed at Mont Terri. We are currently planning a controlled thermal stimulation of the fault, where instead of fluid injection as a trigger mechanism we will heat up the nearby rock volume and measure potential effects on fault stability. Lessons learned from our past and future experiments will help inform the safety assessment of geologic disposal in argillite host rock.

Birkholzer, Jens T.↗

Fault Detection in the Solvent Extraction Process with Non-traditional Sensors

Solvent extraction is used to separate metals or other complexes into two different immiscible liquids and is an essential component of the PUREX Process. Improvements to the solvent extraction process can directly contribute to an organization’s ability to ensure the purity and recovery of special nuclear materials from spent nuclear fuel. Such improvements can benefit nuclear reprocessing efforts, increase fuel reutilization, and limit the concentration of actinides in nuclear waste repositories.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Resilient Autonomous Wind Farms: Preprint

With the advent of an increasing number of control strategies that seek to optimize wind turbine performance on a farm-level, taking account of individual wind turbine information to achieve wind farm-level objectives has become an increasingly important goal. Methods for controlling wind turbines on an individual and farm level have seen significant development, and an abundance of new implementations for gathering and using data from turbines have created potential for novel control mechanisms which can further optimize the performance and delivery characteristics of a wind farm. A key element of making these wind farms more efficient is to develop reliable algorithms that use local sensor information that is already being collected, such as supervisory control and data acquisition (SCADA) data, local meteorological stations, and nearby radars/sodars/lidars. Making use of information from all wind turbines in a wind farm can enable such approaches as determining the atmospheric conditions across the farm, improving fault-finding, and enabling more efficient overall control of farm-wide optimizations through mechanisms such as wake-steering. However, these approaches typically involve a centralized communications and control center. In order to ensure the resilient operation of the farm, it is necessary to develop an approach which distributes the calculation and communication amongst multiple nodes throughout the farm. In this fashion, a redundant, robust, and secure network can be created, which can tolerate faults in calculation, communication, and even external attacks which seek to disrupt the operation of the wind farm. This paper introduces the use of the Raft Byzantine Fault Tolerance algorithm in the implementation of autonomous control of a wind farm. This implementation will allow for fault tolerance for malfunctioning nodes, sensors, transmitters, and connectors. This approach is equally extensible to account for malicious actors. It will be shown to achieve overall consensus, provided the number of faults/malicious nodes is less than 3$n$+1, where $n$ is the number of turbine cluster faults which may occur, and to be robust in the face of multiple arbitrary faults.

autonomous↗

Resilient Autonomous Wind Farms

With the advent of an increasing number of control strategies that seek to optimize wind turbine performance on a farm level, taking into account individual wind turbine information to achieve wind-farm-level objectives has become an increasingly important goal. Methods for controlling wind turbines on an individual and farm level have experienced significant development, and an abundance of new implementations for gathering and using data from turbines have created potential for novel control mechanisms that can further optimize the performance and delivery characteristics of a wind farm. A key element of making these wind farms more efficient is to develop reliable algorithms that use local sensor information that is already being collected, such as from local meteorological stations, nearby radars, sodars, and lidars, and supervisory control and data acquisition (SCADA) data. Making use of information from all wind turbines in a wind farm can enable such approaches as determining the atmospheric conditions across the farm, improving fault-finding, and ensuring more efficient overall control of farmwide optimizations through mechanisms such as wake steering. However, these approaches typically involve a centralized communications and control center. In order to ensure the resilient operation of the farm, it is necessary to develop an approach that distributes the calculation and communication amongst multiple nodes throughout the farm. In this fashion, a redundant, robust, and secure network can be created, which can tolerate faults in calculation, communication, and even external attacks that seek to disrupt the operation of the wind farm. This paper introduces the use of the Raft-Byzantine-Fault-Tolerant algorithm in the implementation of autonomous control of a wind farm. This implementation will allow for fault tolerance for malfunctioning nodes, sensors, transmitters, and connectors. This approach is equally extensible to account for malicious actors. It will...

fault tolerance↗

Securing Grid-interactive Efficient Buildings (GEB) through Cyber Defense and Resilient System (CYDRES)

The DOE CYDRES project is driven by the urgent need to address critical research gaps in the domain of cyber-physical security of smart buildings, including Grid-interactive Efficient Buildings (GEBs). CYDRES, a real-time advanced building resilient platform, aims to enhance the cyber-attack-immune capabilities of buildings through multi-layered prevention, detection, and adaptation mechanisms. CYDRES consists of five key modules: a multi-layer network analyzer, an Automatic Fault Detection, Diagnosis, and Prognosis (AFDDP) framework, an intelligent mode selector, a cyber-resilient control framework, and a situation awareness platform. The Network Analyzer employs a data-driven framework that includes a protocol state learning tool and a CRF (Conditional Random Field) command validator. In Hardware-In-the-Loop (HIL) testbeds, it achieved 100% detection accuracy with a false alarm rate of 3%, validating its efficacy in identifying selected cyber-attacks. The AFDDP framework leverages pattern matching, PCA (Principal Component Analysis)-based strategies, and a DBN (Dynamic Bayesian Network)-based fault diagnosis approach to pinpoint the causes of physical system abnormalities using Building Automation System (BAS) data. In HIL experiments, the AFDDP module attained a detection accuracy of over 95% with a false alarm rate below 7%. Additionally, the fault detector utilized machine learning (Random Forest) and deep learning (Multi-Layer Perceptron) methods with acoustic sensor data to achieve a 100% fault detection accuracy in Heating, Ventilation, and Air-Conditioning (HVAC) equipment. The Mode Selector offered real-time impact analysis, allowing immediate actions to protect BASs in the face of emerging threats. The cyber-resilient control framework included an adaptive Model Predictive Control (MPC) and a measurement compensator, reducing temperature violations by up to 94% and improving the total demand flexibility by up to 70% in HIL experiments. Such HIL experiments covered a cyber-attack case and a physical fault case, showcasing CYDRES’ efficiency in maintaining operational continuity during threats. The situation awareness platform in Grafana enhanced real-time threat detection and response visualization, augmenting the operational awareness for building operators. CYDRES demonstrated high technical effectiveness in various test scenarios, particularly in HIL environments. The project's phased development approach ensured efficient use of resources, highlighting its practical feasibility and readiness for commercialization. By enhancing the security and resilience of building operations, CYDRES represents a significant advance in mitigating risks associated with cyber-physical systems, thereby enhancing public confidence in the safety of modern building infrastructure. Future directions for the project include expanding testing protocols, refining AFDDP methodologies, exploring more comprehensive resilient control strategies, and testing in real commercial buildings.

42 ENGINEERING↗

Active‐Source Seismic Imaging of Fault Re‐Activation and Leakage: An Injection Experiment at the Mt Terri Rock Laboratory, Switzerland

Abstract We conducted a time‐lapse seismic experiment utilizing automated active seismic source and sensor arrays to monitor a reactivated fault within the Opalinus clay formation at the Mont Terri Rock Laboratory (Switzerland), an analog caprock for geologic carbon storage. A series of six brine injections were conducted into the so‐called Main Fault to reactivate it. Seismic instrumentation in five monitoring boreholes on either side of the fault was used to continuously probe changes in P‐wave travel‐times associated with fault displacement and leakage. We performed time‐lapse travel‐time tomography on five hundred sequential data sets; this revealed a zone of decreased P‐wave velocity, up to 16 m/s, during each injection cycle, followed by a velocity increase during shut‐in. These results demonstrate varying elastic property perturbations, both spatially and temporally, along the fault plane during reactivation. We then interpreted these velocity changes in terms of fault dilation induced by pressurized fluids along the fault.

58 GEOSCIENCES↗

Performance Results for Sensor Assignment Problem as Solved on a Multi-Node Cluster

An earlier report described a procedure for optimal sensor set selection and its implementation on a computational cluster. This new and innovative capability was developed to facilitate a reduction in operations staffing levels to improve plant economics. By automating surveillance and maintenance tasks through early detection of degrading sensors and equipment, staff can be more efficiently deployed. The method uses automated reasoning and domain knowledge in the form of the conservation equations to infer from plant measurements the state of equipment health. Inclusion of domain knowledge addresses the problem that exists with pure data-driven methods that there are no rigorous guidelines for determining what constitutes an adequate sensor set. Formalizing the procedure for sensor set selection as we have done results in a more reliable and explainable diagnosis of plant equipment health. Importantly, from the standpoint of the plant owner, personnel are provided with an early and explicit diagnosis of an equipment problem. That in principle automates the process and eliminates having to send personnel into the plant to find the cause as typically occurs when a data-driven method detects an anomaly. In this report we describe first results obtained using a computational cluster to solve the sensor set selection problem as framed above. The case described addresses the problem of equipment health monitoring in the high-pressure (HP) feedwater system of a pressurized light water reactor as seen through the eyes of our collaborating utility partner. Maintenance of this system can amount to millions of dollars per year if equipment health issues go undiagnosed and lead to loss of function. On examining the potential that is inherent in the installed sensor set for diagnosing equipment health degradation, it was found that greater fault resolution capability can be achieved using a sensor set that is 20 percent fewer in number. The take-away is that compared to the installed sensor set there exists a more strategic assignment of sensors that will furnish better health monitoring capability and with fewer sensors. Where the problem defies solution by manual inspection, as is the case here, one can be found by an algorithm. The solution was obtained in four hours using 30 computational cores. The HP feedwater problem as posed above illustrates the added value of approaching the sensor selection problem as one amenable to algorithmic solution. This problem is of interest to advanced reactor designers and to utilities that are setting up remote monitoring and diagnostic centers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗