MO-AB-BRA-08: A Modular Multi-Source X-Ray Tube for Novel Computed Tomography Applications

Purpose: To develop and build a practical implementation of an x-ray line source for the rapidly increasing number of multi-source imaging applications in CT. Methods: An innovative x-ray tube was designed using CST Particle Studio, ANSYS, and SolidWorks. A slowly varying magnetic field is synchronized with microsecond gating of multiple thermionic electron sources. Electrostatic simulations were run to optimize the geometry of the optics and prevent electrode arcing. Magnetostatic simulations were used for beam deflection studies and solenoid design. Particle beam trajectories were explored with an emphasis on focusing, acceleration, deflection, and space charge effects. Thermal constraints were analyzed for both transient and steady-state regimes. Electromagnetic simulations informed the design of a prototype unit under construction. Results: Particle tracking simulations for a benchtop system demonstrate that three 80 keV electron beams are able to be finely controlled and laterally swept a combined distance of 15 cm over a stationary target with an oscillating magnetic field in the hundreds of gauss. The beams are pulsed according to scanning sequences developed for implementation in a mock stationary CT scanner capable of a 30 ms temporal resolution. Beam spot diameters are approximately 1 mm for 30 mA beams and the stationary target stays well within thermal limits. The relevant hardware and control circuits were developed for incorporation into a physical prototype. Conclusion: A new multi-source x-ray tube was designed in a modular form factor to push the barriers of high-speed CT and spur growth in emerging imaging applications. This technology can be used as the basis for a stationary high-speed CT scanner, a system for generating a virtual fan-beam for dose reduction, or for reducing scatter radiation in cone-beam CT utilizing a tetrahedron beam CT geometry. A 2.4 kW benchtop system is currently being built to show proof of concept for the tube. Support for this research was provided by the University of Wisconsin Madison, Office of the Vice Chancellor for Research and Graduate Education with funding from the Wisconsin Alumni Research Foundation.

60 APPLIED LIFE SCIENCES↗

Development of Low-Noise High Value Chromium Silicide Resistors for Cryogenic Detector Applications

Extremely high sensitivity detectors, such as silicon bolometers are required in many NASA missions for detection of photons from the x-ray to the far infrared regions. Typically, these detectors are cooled to well below the liquid helium (LHe) temperature (4.2 K) to achieve the maximum detection performance. As photoconductors, they are generally operated with a load resistor and a pre-set bias voltage, which is then coupled to the input gate of a source-follower Field Effect Transistor (FET) circuit. It is imperative that the detector system signal to noise performance be limited by the noise of the detector and not by the noise of the external components. The load resistor value is selected to optimize the detector performance. These two criteria tend to be contradictory in that these detectors require load resistors in the hundreds of megaohms, which leads to a higher Johnson noise. Additionally, the physical size of the resistor must be small for device integration as required by such missions as the NASA High Resolution Airborne Wide-Band Camera (HAWC) instrument and the Submillimeter High Angular Resolution Camera (SHARC) for the Caltech Submillimeter Observatory (CSO). We have designed, fabricated and characterized thin film resistors using a CrSi/TiW/Al metal system on optical quality quartz substrates. The resistor values range from 100 megaohms to over 650 megaohms and are Johnson noise limited at LHe temperatures. The resistor film is sputtered with a sheet resistance ranging from 300 ohms to 1600 ohms and the processing sequence developed for these devices allows for chemically fine tuning the sheet resistance in-situ. The wafer fabrication process was of sufficiently high yield (>80%) providing clusters of good resistors for integrated multiple detector channels, a very important feature in the assembly of these two instruments.

Jhabvala, Murzy↗

MCTP system model based on linear programming optimization of apertures obtained from sequencing patient image data maps

Purpose: The authors present a hybrid direct multileaf collimator (MLC) aperture optimization model exclusively based on sequencing of patient imaging data to be implemented on a Monte Carlo treatment planning system (MC-TPS) to allow the explicit radiation transport simulation of advanced radiotherapy treatments with optimal results in efficient times for clinical practice. Methods: The planning system (called CARMEN) is a full MC-TPS, controlled through aMATLAB interface, which is based on the sequencing of a novel map, called “biophysical” map, which is generated from enhanced image data of patients to achieve a set of segments actually deliverable. In order to reduce the required computation time, the conventional fluence map has been replaced by the biophysical map which is sequenced to provide direct apertures that will later be weighted by means of an optimization algorithm based on linear programming. A ray-casting algorithm throughout the patient CT assembles information about the found structures, the mass thickness crossed, as well as PET values. Data are recorded to generate a biophysical map for each gantry angle. These maps are the input files for a home-made sequencer developed to take into account the interactions of photons and electrons with the MLC. For each linac (Axesse of Elekta and Primus of Siemens) and energy beam studied (6, 9, 12, 15 MeV and 6 MV), phase space files were simulated with the EGSnrc/BEAMnrc code. The dose calculation in patient was carried out with the BEAMDOSE code. This code is a modified version of EGSnrc/DOSXYZnrc able to calculate the beamlet dose in order to combine them with different weights during the optimization process. Results: Three complex radiotherapy treatments were selected to check the reliability of CARMEN in situations where the MC calculation can offer an added value: A head-and-neck case (Case I) with three targets delineated on PET/CT images and a demanding dose-escalation; a partial breast irradiation case (Case II) solved with photon and electron modulated beams (IMRT + MERT); and a prostatic bed case (Case III) with a pronounced concave-shaped PTV by using volumetric modulated arc therapy. In the three cases, the required target prescription doses and constraints on organs at risk were fulfilled in a short enough time to allow routine clinical implementation. The quality assurance protocol followed to check CARMEN system showed a high agreement with the experimental measurements. Conclusions: A Monte Carlo treatment planning model exclusively based on maps performed from patient imaging data has been presented. The sequencing of these maps allows obtaining deliverable apertures which are weighted for modulation under a linear programming formulation. The model is able to solve complex radiotherapy treatments with high accuracy in an efficient computation time.

60 APPLIED LIFE SCIENCES↗

Orders of vanishing and U(1) charges in F-theory

Many interesting questions about F-theory models, including several concerning the F-theory swampland, involve massless matter charged under U(1) gauge symmetries. It is therefore important to better understand the geometric properties of F-theory models realizing various U(1) charges. We propose that, for F-theory models described by elliptic fibrations in Weierstrass form, the U(1) charge of light matter is encoded in the orders of vanishing of the section components corresponding to the U(1) gauge symmetry. We give specific equations relating the U(1) charges to the orders of vanishing that seem to hold for both U(1)-charged singlets and for matter additionally charged under a simply-laced nonabelian gauge algebra. Our formulas correctly describe properties of F-theory models in the prior literature, and we give an argument that they should describe the orders of vanishing for arbitrarily high U(1) charges. They also resemble formulas for the p-adic valuations of elliptic divisibility sequences developed by Stange. These proposals could serve as a U(1) analogue of the Katz-Vafa method, allowing one to determine U(1) charges without resolution. Additionally, they predict geometric information about F-theory models with general U(1) charges, which may be useful for exploring the F-theory landscape and swampland.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Image-Based Monitoring of Magnetic Resonance-Guided Thermoablative Therapies for Liver Tumors

Minimally invasive treatment options for liver tumor therapy have been increasingly used during the last decade because their benefit has been proven for primary and inoperable secondary liver tumors. Among these, radiofrequency ablation has gained widespread consideration. Optimal image-guidance offers precise anatomical information, helps to position interventional devices, and allows for differentiation between already-treated and remaining tumor tissue. Patient safety and complete ablation of the entire tumor are the overriding objectives of tumor ablation. These may be achieved most elegantly with magnetic resonance (MR)-guided therapy, where monitoring can be performed based on precise soft-tissue imaging and additional components, such as diffusion-weighted imaging and temperature mapping. New MR scanner types and newly developed sequence techniques have enabled MR-guided intervention to move beyond the experimental phase. This article reviews the current role of MR imaging in guiding radiofrequency ablation. Signal characteristics of primary and secondary liver tumors are identified, and signal alteration during therapy is described. Diffusion-weighted imaging (DWI) and temperature mapping as special components of MR therapy monitoring are introduced. Practical information concerning coils, sequence selection, and parameters, as well as sequence gating, is given. In addition, sources of artifacts are identified and techniques to decrease them are introduced, and the characteristic signs of residual tumor in T1-, T2-, and DWI are described. We hope to enable the reader to choose MR sequences that allow optimal therapy monitoring depending on the initial signal characteristics of the tumor as well as its size and location in the liver.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proton-detected 15 N- 1 H dipolar coupling/ 1 H chemical shift correlation experiment for the measurement of NH distances in biological solids under fast MAS solid-state NMR

Measurement of distances from dipolar couplings is essential for structural characterization, refinement and validation using the solid-state nuclear magnetic resonance (ssNMR) spectroscopy. Particularly, knowledge about NH dipolar interactions in biological solids is important for understanding the hydrogen (H)-bonding interactions, molecular geometry and spin dynamics. In this regard, we have proposed a proton-detected two-dimensional (2D) 15 N- 1 H dipolar coupling/ 1 H chemical shift correlation experiment using the C-symmetry based windowless recoupling of chemical shift anisotropy (ROCSA) in combination with the DIPSHIFT pulse-based method for the measurement of short NH distances in the isotopically labeled and naturally abundant biological solids at fast magic angle spinning (MAS) rates (40–70 kHz). Our proposed method results in undistorted recoupled 15 N- 1 H dipolar coupling powder lineshapes that are free from the recoupled 1 H CSA contributions under the 15 N evolution, a feature that is essential for the measurement of NH distances with improved accuracy (± 500 Hz in terms of the NH dipolar couplings). The pulse sequence developed in the present study is also insensitive to the 1H–1H homonuclear dipolar interactions, relaxation effects owing to its constant-time implementation, and t1-noise from the fluctuations in the MAS.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

UNUSUAL {sup 29,30}Si-RICH SiCs OF MASSIVE STAR ORIGIN FOUND WITHIN GRAPHITES FROM THE MURCHISON METEORITE

Correlated transmission electron microscopy and NanoSIMS isotopic studies have revealed two unusual SiCs with large {sup 29,30}Si enrichments within micron-sized graphites from the Murchison meteorite. Such anomalies are rare among the overall SiC population (in <<0.01% of SiCs yet measured), whereas two of the three SiCs found within graphite show {sup 29,30}Si enrichments, in one case as large as {sup 29}Si/{sup 28}Si = (2.28 {+-} 0.03) x solar and {sup 30}Si/{sup 28}Si = (2.03 {+-} 0.03)x solar. C-burning and Ne-burning in massive stars (>8 M{sub sun} initial mass) during their post-main-sequence development are the only processes capable of producing sufficiently large {sup 29,30}Si enrichments. This material with heavy Si isotopic enrichments from the O/Ne and O/Si layers is later incorporated into carbonaceous stardust, either in ejecta from Type II supernovae or perhaps in the colliding winds of Wolf-Rayet binaries. Although often too small for Si isotopic measurements, four other SiC-containing graphites show other signatures of a massive star origin. Abundance estimates suggest that such unusual SiCs are present within {approx}1% of high-density graphites. This abundance can be reconciled with the much lower abundance in the overall SiC population if these unusual SiCs are naturally smaller ({approx}200 nm or less) than SiCs from other isotopic subgroups and if differential destruction of small unusual SiCs occurs in massive star outflows unless these SiCs are encapsulated in graphite.

79 ASTRONOMY AND ASTROPHYSICS↗

HIGH-VELOCITY LINE FORMING REGIONS IN THE TYPE Ia SUPERNOVA 2009ig

We report measurements and analysis of high-velocity (HVF) (>20,000 km s{sup –1}) and photospheric absorption features in a series of spectra of the Type Ia supernova (SN) 2009ig obtained between –14 days and +13 days with respect to the time of maximum B-band luminosity (B-max). We identify lines of Si II, Si III, S II, Ca II, and Fe II that produce both HVF and photospheric-velocity (PVF) absorption features. SN 2009ig is unusual for the large number of lines with detectable HVF in the spectra, but the light-curve parameters correspond to a slightly overluminous but unexceptional SN Ia (M{sub B} = –19.46 mag and Δm{sub 15}(B) = 0.90 mag). Similarly, the Si II λ6355 velocity at the time of B-max is greater than 'normal' for an SN Ia, but it is not extreme (v{sub Si} = 13,400 km s{sup –1}). The –14 days and –13 days spectra clearly resolve HVF from Si II λ6355 as separate absorptions from a detached line forming region. At these very early phases, detached HVF are prevalent in all lines. From –12 days to –6 days, HVF and PVF are detected simultaneously, and the two line forming regions maintain a constant separation of about 8000 km s{sup –1}. After –6 days all absorption features are PVF. The observations of SN 2009ig provide a complete picture of the transition from HVF to PVF. Most SNe Ia show evidence for HVF from multiple lines in spectra obtained before –10 days, and we compare the spectra of SN 2009ig to observations of other SNe. We show that each of the unusual line profiles for Si II λ6355 found in early-time spectra of SNe Ia correlate to a specific phase in a common development sequence from HVF to PVF.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-J-90: MRI-Based Treatment Simulation and Patient Setup for Radiation Therapy of Brain Cancer

Purpose: Traditional radiation therapy of cancer is heavily dependent on CT. CT provides excellent depiction of the bones but lacks good soft tissue contrast, which makes contouring difficult. Often, MRIs are fused with CT to take advantage of its superior soft tissue contrast. Such an approach has drawbacks. It is desirable to perform treatment simulation entirely based on MRI. To achieve MR-based simulation for radiation therapy, bone imaging is an important challenge because of the low MR signal intensity from bone due to its ultra-short T2 and T1, which presents difficulty for both dose calculation and patient setup in terms of digitally reconstructed radiograph (DRR) generation. Current solutions will either require manual bone contouring or multiple MR scans. We present a technique to generate DRR using MRI with an Ultra Short Echo Time (UTE) sequence which is applicable to both OBI and ExacTrac 2D patient setup. Methods: Seven brain cancer patients were scanned at 1.5 Tesla using a radial UTE sequence. The sequence acquires two images at two different echo times. The two images were processed using in-house software. The resultant bone images were subsequently loaded into commercial systems to generate DRRs. Simulation and patient clinical on-board images were used to evaluate 2D patient setup with MRI-DRRs. Results: The majority bones are well visualized in all patients. The fused image of patient CT with the MR bone image demonstrates the accuracy of automatic bone identification using our technique. The generated DRR is of good quality. Accuracy of 2D patient setup by using MRI-DRR is comparable to CT-based 2D patient setup. Conclusion: This study shows the potential of DRR generation with single MR sequence. Further work will be needed on MR sequence development and post-processing procedure to achieve robust MR bone imaging for other human sites in addition to brain.

60 APPLIED LIFE SCIENCES↗

Investigating Wireless Quantum Key Distribution for Advanced Reactor Communications

Remote operation of small modular reactor (SMR) facilities is an appealing prospect for streamlined operation costs, safety concerns, and user convenience. The ability to guarantee security of communication channels between offsite users and nuclear reactor facilities is critical to enabling remote operations, given the sensitive nature of reactor state data. This report proposes a configuration implementing quantum key distribution (QKD) and advanced encryption standard (AES) protocols to establish secure reactor data feeds. The model outlined, which utilizes the Argonne-developed SeQUeNCe software package and custom MATLAB code, determines free-space channel losses for microwave-band communications in a variety of weather conditions and simulates QKD via ground-satellite links. This report demonstrates the feasibility of repeatable, real-time key generation and distribution for this configuration towards enabling secure wireless reactor communications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

2008 Marine Microbes Gordon Research Conference (July 13-17, 2008)

Marine microbes are very abundant and diverse. They play significant roles in all element cycles, both quantitatively and qualitatively. However, they are little known, as the continuous series of surprising discoveries in the last few years shows. In the present conference the main focus will be on how these microbes interact: with other cells of their own species, with other microbes and with large living beings, from biofilms to symbiants. Another important topic will be the exploration of marine microbial diversity based on the recently developed sequencing approaches and on efforts to obtain marine organisms in pure cultures. This conference will be the third in the Marine Microorganisms series. We hope it will contribute to enlarge the community of marine microbiologists and help in pointing the future directions of research even more than the two previous meetings.

59 BASIC BIOLOGICAL SCIENCES↗

The Viking decelerator system - An overview.

The Viking mission to place an instrumented lander on Mars in 1976 includes an aerodynamic decelerator as part of the landing sequence. Development of the decelerator, a single-stage mortared disk-gap-band parachute, began in 1965 for the Voyager project and culminated in the flight qualification of the decelerator system for the Viking mission in 1972. This paper summarizes the research, development, and qualification effort. The special operating conditions and the constraints imposed by the Viking mission and the Mars atmosphere, their effects on the decelerator system, and the solution of the resulting technical problems are briefly described.

Gillis, C. L.↗

Centaur propellant acquisition system study

A study was performed to determine the desirability of replacing the hydrogen peroxide settling system on the Centaur D-1S with a capillary acquisition system. A comprehensive screening was performed to select the most promising capillary device fluid acquisition, thermal conditioning, and fabrication techniques. Refillable start baskets and bypass feed start tanks were selected for detailed design. Critical analysis areas were settling and refilling, start sequence development with an initially dry boost pump, and cooling the fluid delivered to the boost pump in order to provide necessary net position suction head (NPSH). Design drawings were prepared for the start basket and start tank concepts for both LO2 and LH2 tanks. System comparisons indicated that the start baskets using wicking for thermal conditioning, and thermal subcooling for boost pump NPSH, are the most desirable systems for future development.

Blatt, M. H.↗

Centaur propellant acquisition system

The desirability of replacing the hydrogen peroxide settling system of the Centaur D-1S with a capillary acquisition system was evaluated. A comprehensive screening was performed to select the most promising capillary device fluid acquisition, thermal conditioning, and fabrication techniques. Refillable start baskets and bypass feed start tanks were selected for detailed design. Critical analysis areas were settling and refilling, start sequence development with an initially dry boost pump, and cooling the fluid delivered to the boost pump to provide the necessary net positive suction head (NPSH). Design drawings were prepared for start basket and start tank concepts for both the liquid oxygen and liquid hydrogen tanks. System comparisons indicated that the start baskets using wicking flow for thermal conditioning, and thermal subcooling for providing boost pump NPSH, are the most desirable systems for future Centaur acquisition system development.

Blatt, M. H.↗

Flat-plate solar array progress and plans

The Flat-Plate Solar Array Project (FSA), sponsored by the U.S. Department of Energy (DOE) and managed by the Jet Propulsion Laboratory (JPL), has achieved progress in a broad range of technical activities since that reported at the Fourth European Communities Conference. A particularly important analysis has been completed recently which confirms the adoption into practice by the U.S. Photovoltaic (PV Industry, of all the low-cost module technology elements proposed at the 16th Project Integration Meeting for a $2.80/Wp (1980 U.S. Dollars) design approach in the fall of 1980. This work presents along with a projection, using the same techniques, for what is believed to be a very credible ribbon-based module design for less that $0.55/Wp (1980 U.S. Dollars). Other areas to be reported upon include low-cost Si feedstock refinement; ribbon growth; process sequence development for cells; environmental isolation; engineering science investigations; and module testing progress.

Callaghan, W. T.↗

On recent advances and future research directions for computational fluid dynamics

This paper highlights some recent accomplishments regarding CFD numerical algorithm constructions for generation of discrete approximate solutions to classes of Reynolds-averaged Navier-Stokes equations. Following an overview of turbulent closure modeling, and development of appropriate conservation law systems, a Taylor weak-statement semi-discrete approximate solution algorithm is developed. Various forms for completion to the final linear algebra statement are cited, as are a range of candidate numerical linear algebra solution procedures. This development sequence emphasizes the key building blocks of a CFD RNS algorithm, including solution trial and test spaces, integration procedure and added numerical stability mechanisms. A range of numerical results are discussed focusing on key topics guiding future research directions.

Baker, A. J.↗