Search NASA⌕ Search

SEARCH · Search NASA

Results for “serial detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Design decisions from the history of the EUVE science payload

Some of the design issues that arose during the development of the EUVE science payload and solutions to the problems involved are examined. In particular, attention is given to the use of parallel and serial busses, the selection of the the ROM approach for software storage and execution, implementation of memory error detection and correction, and the selection of command structures. The early design decisions paid off in the timely delivery of the scientific payload and in the successful completion of the survey phase of the EUVE science mission.

Marchant, W.↗

Preliminary Results From a Heavily Instrumented Engine Ice Crystal Icing Test in a Ground Based Altitude Test Facility

Preliminary results from the heavily instrumented ALF502R-5 engine test conducted in the NASA Glenn Research Center Propulsion Systems Laboratory are discussed. The effects of ice crystal icing on a full scale engine is examined and documented. This same model engine, serial number LF01, was used during the inaugural icing test in the Propulsion Systems Laboratory facility. The uncommanded reduction of thrust (rollback) events experienced by this engine in flight were simulated in the facility. Limited instrumentation was used to detect icing on the LF01 engine. Metal temperatures on the exit guide vanes and outer shroud and the load measurement were the only indicators of ice formation. The current study features a similar engine, serial number LF11, which is instrumented to characterize the cloud entering the engine, detect/characterize ice accretion, and visualize the ice accretion in the region of interest. Data were acquired at key LF01 test points and additional points that explored: icing threshold regions, low altitude, high altitude, spinner heat effects, and the influence of varying the facility and engine parameters. For each condition of interest, data were obtained from some selected variations of ice particle median volumetric diameter, total water content, fan speed, and ambient temperature. For several cases the NASA in-house engine icing risk assessment code was used to find conditions that would lead to a rollback event. This study further helped NASA develop necessary icing diagnostic instrumentation, expand the capabilities of the Propulsion Systems Laboratory, and generate a dataset that will be used to develop and validate in-house icing prediction and risk mitigation computational tools. The ice accretion on the outer shroud region was acquired by internal video cameras. The heavily instrumented engine showed good repeatability of icing responses when compared to the key LF01 test points and during day-to-day operation. Other noticeable observations are presented.

Enigine Icing↗

Control of a GaAs monolithic Ka-band phase shifter using a high-speed optical interconnect

The use of a high-speed optical interconnect in the control of a Ka-band GaAs monolithic phase shifter is described. A 16-b serial control signal was used to modulate the output of a laser transmitter, and the transmitted optical signal was detected and demultiplexed into 16 parallel electrical outputs using a high-speed hybrid GaAs optoelectronic integrated circuit. Four of the parallel output lines were interfaced to the 4-b phase shifter, and high-speed, optically controlled switching of the phase shifter was observed at clock frequencies to 30 MHz using an interferometric technique.

Bhasin, K. B.↗

A unifying Bayesian framework for merging X-ray diffraction data

Novel X-ray methods are transforming the study of the functional dynamics of biomolecules. Key to this revolution is detection of often subtle conformational changes from diffraction data. Diffraction data contain patterns of bright spots known as reflections. To compute the electron density of a molecule, the intensity of each reflection must be estimated, and redundant observations reduced to consensus intensities. Systematic effects, however, lead to the measurement of equivalent reflections on different scales, corrupting observation of changes in electron density. Here, we present a modern Bayesian solution to this problem, which uses deep learning and variational inference to simultaneously rescale and merge reflection observations. We successfully apply this method to monochromatic and polychromatic single-crystal diffraction data, as well as serial femtosecond crystallography data. We find that this approach is applicable to the analysis of many types of diffraction experiments, while accurately and sensitively detecting subtle dynamics and anomalous scattering.

59 BASIC BIOLOGICAL SCIENCES↗

Data Acquisition and Processing System for Airborne Wind Profiling with a Pulsed, 2-Micron, Coherent-Detection, Doppler Lidar System

A data acquisition and signal processing system is being developed for a 2-micron airborne wind profiling coherent Doppler lidar system. This lidar, called the Doppler Aerosol Wind Lidar (DAWN), is based on a Ho:Tm:LuLiF laser transmitter and 15-cm diameter telescope. It is being packaged for flights onboard the NASA DC-8, with the first flights in the summer of 2010 in support of the NASA Genesis and Rapid Intensification Processes (GRIP) campaign for the study of hurricanes. The data acquisition and processing system is housed in a compact PCI chassis and consists of four components such as a digitizer, a digital signal processing (DSP) module, a video controller, and a serial port controller. The data acquisition and processing software (DAPS) is also being developed to control the system including real-time data analysis and display. The system detects an external 10 Hz trigger pulse and initiates the data acquisition and processing process, and displays selected wind profile parameters such as Doppler shift, power distribution, wind directions and velocities. Doppler shift created by aircraft motion is measured by an inertial navigation/GPS sensor and fed to the signal processing system for real-time removal of aircraft effects from wind measurements. A general overview of the system and the DAPS as well as the coherent Doppler lidar system is presented in this paper.

Beyon, J. Y.↗

Iron(III) Nitrate/TEMPO-Catalyzed Aerobic Alcohol Oxidation: Distinguishing between Serial versus Integrated Redox Cooperativity

Aerobic alcohol oxidations catalyzed by transition metal salts and aminoxyls are prominent examples of cooperative catalysis. Cu/aminoxyl catalysts have been studied previously and feature “integrated cooperativity”, in which Cu II and the aminoxyl participate together to mediate alcohol oxidation. Here we investigate a complementary Fe/aminoxyl catalyst system and provide evidence for “serial cooperativity”, involving a redox cascade wherein the alcohol is oxidized by an in situ-generated oxoammonium species, which is directly detected in the catalytic reaction mixture by cyclic step chronoamperometry. The mechanistic difference between the Cu- and Fe-based catalysts arises from the use iron(III) nitrate, which initiates a NO x -based redox cycle for oxidation of aminoxyl/hydroxylamine to oxoammonium. Here, the different mechanisms for the Cu- and Fe-based catalyst systems are manifested in different alcohol oxidation chemoselectivity and functional group compatibility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spectral Measurement Errors due to CCD Serial Pixel-to-Pixel Readout Interference in the Ocean Color Instrument of the NASA PACE Mission

The Ocean Color Instrument on NASA’s PACE mission is a hyperspectral imager with a spatial resolution of 1km x 1km and spectral resolution of 5nm in 2.5nm steps over 320-890nm. The detection system is based on two Charge-Coupled Devices (CCDs) operating in Time Delay Integration (TDI) mode to achieve high signal-to-noise ratio. The front-end optical imager is a rotating mirror-based system that images the ground-scene onto a slit with a field of view of 16km x 1km. The slit-image is re-imaged and wavelength dispersed on the CCDs. As the ground-scene moves through the slit, it moves along the CCD columns as charge is moved along with it. The accumulated charge at the end of each column is collected in a serial pixel. Each of the 16 CCD outputs read out 32 columns of the same ground scene spaced 0.625nm apart. The 32-pixel serial register is swiftly read out before the next TDI cycle. The telescope is spinning at 5.77Hz to achieve the required spatial resolution. This results in a serial pixel readout speed of 8.5MHz. Each serial read-cycle goes through a reset and video period that are each sampled to create a low-noise correlated double sample value. This only allows 59ns for the reset and video to be asserted and settled before sampling. Due to the short time period, the response of the CCD exhibits serial pixel-to-pixel readout interference as the reset and video signals do not have time to fully settle before sampling. Each serial pixel value therefore has a dependence on the value of the preceding pixel value. This leads to a spectral measurement error of up to 0.3%. We explain the operation of the detection system, the behavior of the interference and the resulting wavelength error with results from ground testing and on-orbit characterization.

Ulrik B Gliese↗

Status of the Delco Systems Operations forward looking windshear detection program

Delco Systems Operations, a division of General Motors Hughes Electronics Corporation, is developing a Forward Looking Windshear Detection System based on the integration of infrared remote sensing and accelerometer reactive sensing technologies. The infrared sensor is a multi-spectral, scanning radiometer operating in the 8 to 14 micron region. A 2 x 5 detector array with parallel-serial scanning produces 60 degrees horizontal and 10 degrees vertical-fields of view. Using multiple wavelength signals, azimuth temperature gradients are analyzed for characteristic signatures of thermally induced windshear phenomena. Elevation temperature gradients are processed through an atmosphere model to continuously compute a stability index for arming microburst detection criteria. The atmosphere model and proprietary computer processing algorithms combine to generate coarse estimates of disturbance ranges based on multiple wavelength radiance data with different extinction coefficients. Computer outputs of atmospheric stability, disturbance intensity, and azimuth and range information provide a situation display capability. A ground operated, experimental radiometer has been developed and is being used to verify the detection and discrimination concepts at an atmospheric and simulated rain test facility in Milwaukee. A prototype airborne radiometer is being developed for flight test evaluation during the summer of 1989.

Gallagher, Brian J.↗

Efficient Mosaicking of Spitzer Space Telescope Images

A parallel version of the MOPEX software, which generates mosaics of infrared astronomical images acquired by the Spitzer Space Telescope, extends the capabilities of the prior serial version. In the parallel version, both the input image space and the output mosaic space are divided among the available parallel processors. This is the only software that performs the point-source detection and the rejection of spurious imaging effects of cosmic rays required by Spitzer scientists. This software includes components that implement outlier-detection algorithms that can be fine-tuned for a particular set of image data by use of a number of adjustable parameters. This software has been used to construct a mosaic of the Spitzer Infrared Array Camera Shallow Survey, which comprises more than 17,000 exposures in four wavelength bands from 3.6 to 8 m and spans a solid angle of about 9 square degrees. When this software was executed on 32 nodes of the 1,024-processor Cosmos cluster computer at NASA s Jet Propulsion Laboratory, a speedup of 8.3 was achieved over the serial version of MOPEX. The performance is expected to improve dramatically once a true parallel file system is installed on Cosmos.

Jacob, Joseph↗

Feasibility study for a generalized gate logic software simulator

Unit-delay simulation, event driven simulation, zero-delay simulation, simulation techniques, 2-valued versus multivalued logic, network initialization, gate operations and alternate network representations, parallel versus serial mode simulation fault modelling, extension of multiprocessor systems, and simulation timing are discussed. Functional level networks, gate equivalent circuits, the prototype BDX-930 network model, fault models, identifying detected faults for BGLOSS are discussed. Preprocessor tasks, postprocessor tasks, executive tasks, and a library of bliss coded macros for GGLOSS are also discussed.

Mcgough, J. G.↗

Combined Effects of Spaceflight and Age in Astronauts as Assessed by Areal Bone Mineral Density [BMD] and Trabecular Bone Score

Spaceflight is a potential risk factor for secondary osteoporosis in astronauts. Although lumbar spine (LS) BMD declines rapidly, more than expected for age, there have been no fragility fractures in astronauts that can clearly be attributed to spaceflight. Recently, astronauts have been returning from 6‐month spaceflights with absolute BMD still above young adult mean BMD. In spite of these BMD measurements, we project that the rapid loss in bone mass over long‐duration spaceflight affects the bone microarchitecture of the LS which might predispose astronauts to premature vertebral fractures. Thus, we evaluated TBS, a novel texture index correlated with vertebral bone microarchitecture, as a means of monitoring changes to bone microarchitecture in astronauts as they age. We previously reported that TBS detects an effect of spaceflight (~6‐month duration), independent of BMD, in 51 astronauts (47+/‐4 y) (Smith et al, J Clin Densitometry 2014). Hence, TBS was evaluated in serial DXA scans (Hologic Discovery W) conducted triennially in all active and retired astronauts and more frequently (before spaceflight, after spaceflight and until recovery) in the subset of astronauts flying 4‐6‐ month missions. We used non‐linear models to describe trends in observations (BMD or TBS) plotted as a function of astronaut age. We fitted 1175 observations of 311 astronauts, pre‐flight and then postflight starting 3 years after landing or after astronaut's BMD for LS was restored to within 2% of preflight BMD. Observations were then grouped and defined as follows: 1) LD: after exposure to at least one long‐duration spaceflight > 100 days and 2) SD: before LD and after exposure to at least one short-duration spaceflight < 30 days. Data from males and females were analyzed separately. Models of SD observations revealed that TBS and BMD had similar curvilinear declines with age for both male and female astronauts. However, models of LD observations showed TBS declining with age while BMD appeared stable or trending upward. For females (n=8) LD observations were too few to discern a trend. Notably, models describing trends in TBS appeared to be more sensitive to the effects of age than the models for BMD. We conclude that TBS may provide an additional index for the lumbar spine to monitor the combined changes due to spaceflight and due to aging. This increased knowledge may enhance the ability to identify an intervention trigger for premature vertebral fractures in astronauts.

Sibonga, Jean D.↗

Trabecular Bone Mechanical Properties and Fractal Dimension

Countermeasures for reducing bone loss and muscle atrophy due to extended exposure to the microgravity environment of space are continuing to be developed and improved. An important component of this effort is finite element modeling of the lower extremity and spinal column. These models will permit analysis and evaluation specific to each individual and thereby provide more efficient and effective exercise protocols. Inflight countermeasures and post-flight rehabilitation can then be customized and targeted on a case-by-case basis. Recent Summer Faculty Fellowship participants have focused upon finite element mesh generation, muscle force estimation, and fractal calculations of trabecular bone microstructure. Methods have been developed for generating the three-dimensional geometry of the femur from serial section magnetic resonance images (MRI). The use of MRI as an imaging modality avoids excessive exposure to radiation associated with X-ray based methods. These images can also detect trabecular bone microstructure and architecture. The goal of the current research is to determine the degree to which the fractal dimension of trabecular architecture can be used to predict the mechanical properties of trabecular bone tissue. The elastic modulus and the ultimate strength (or strain) can then be estimated from non-invasive, non-radiating imaging and incorporated into the finite element models to more accurately represent the bone tissue of each individual of interest. Trabecular bone specimens from the proximal tibia are being studied in this first phase of the work. Detailed protocols and procedures have been developed for carrying test specimens through all of the steps of a multi-faceted test program. The test program begins with MRI and X-ray imaging of the whole bones before excising a smaller workpiece from the proximal tibia region. High resolution MRI scans are then made and the piece further cut into slabs (roughly 1 cm thick). The slabs are X-rayed again and also scanned using dual-energy X-ray absorptiometry (DEXA). Cube specimens are then cut from the slabs and tested mechanically in compression. Correlations between mechanical properties and fractal dimension will then be examined to assess and quantify the predictive capability of the fractal calculations.

Hogan, Harry A.↗

An evaluation of the use of new Doppler methods for detecting longitudinal function abnormalities in a pacing-induced heart failure model

BACKGROUND: Doppler tissue echocardiography and color M-mode Doppler flow propagation velocity have proven useful in evaluating cross-sections of patients with left ventricular (LV) dysfunction, but experience with serial changes is limited. Purpose and methods: We tested their use by evaluating the temporal changes of LV function in a pacing-induced congestive heart failure model. Rapid ventricular pacing was initiated and maintained in 20 dogs for 4 weeks. Echocardiography was performed at baseline and weekly during brief pacing cessation. RESULTS: With rapid pacing, LV volume significantly increased and ejection fraction (57%-28%), stroke volume (37-18 mL), and mitral annulus systolic velocity (16.1-6.6 cm/s) by Doppler tissue echocardiography significantly decreased, with ejection fraction and mitral annulus systolic velocity closely correlated (r = 0.706, P <.0001). In contrast to the mitral inflow velocities, mitral annulus early diastolic velocity decreased steadily (12.3-7.3 cm/s) resulting in a dramatic decrease in mitral annulus early/late (1.22-0.57) diastolic velocity with no tendency toward pseudonormalization. The color M-mode Doppler flow propagation velocity also showed significant steady decrease (57-24 cm/s) throughout the pacing period. Multiple regression analysis chose mitral annulus systolic velocity (r = 0.895, P <.0001) and propagation velocity (r = 0.782, P <.0001) for the most important factor predicting LV systolic and diastolic function, respectively. CONCLUSIONS: Doppler tissue echocardiography and color M-mode Doppler flow could evaluate the serial deterioration in LV dysfunction throughout the pacing period. These were more useful in quantifying progressive LV dysfunction than conventional ehocardiographic techniques, and were probably relatively independent of preload. These techniques could be suitable for longitudinal evaluation in addition to the cross-sectional study.

Evaluation Studies↗

Three-dimensional segmentation of luminal and adventitial borders in serial intravascular ultrasound images

Intravascular ultrasound (IVUS) provides exact anatomy of arteries, allowing accurate quantitative analysis. Automated segmentation of IVUS images is a prerequisite for routine quantitative analyses. We present a new three-dimensional (3D) segmentation technique, called active surface segmentation, which detects luminal and adventitial borders in IVUS pullback examinations of coronary arteries. The technique was validated against expert tracings by computing correlation coefficients (range 0.83-0.97) and William's index values (range 0.37-0.66). The technique was statistically accurate, robust to image artifacts, and capable of segmenting a large number of images rapidly. Active surface segmentation enabled geometrically accurate 3D reconstruction and visualization of coronary arteries and volumetric measurements.

NASA Discipline Cardiopulmonary↗

Orthologs of human circulating miRNAs associated with hepatocellular carcinoma are elevated in mouse plasma months before tumour detection

Research examining the potential for circulating miRNA to serve as markers for preneoplastic lesions or early-stage hepatocellular carcinoma (HCC) is hindered by the difficulties of obtaining samples from asymptomatic individuals. As a surrogate for human samples, we identified hub miRNAs in gene co-expression networks using HCC-bearing C3H mice. We confirmed 38 hub miRNAs as associated with HCC in F2 hybrid mice derived from radiogenic HCC susceptible and resistant founders. When compared to a panel of 12 circulating miRNAs associated with human HCC, two had no mouse ortholog and 7 of the remaining 10 miRNAs overlapped with the 38 mouse HCC hub miRNAs. Using small RNA sequencing data generated from serially collected plasma samples in F2 mice, we examined the temporal levels of these 7 circulating miRNAs and found that the levels of 4 human circulating markers, miR-122-5p, miR-100-5p, miR-34a-5p and miR-365-3p increased linearly as the time approaching HCC detection neared, suggesting a correlation of miRNA levels with oncogenic progression. Estimation of change points in the kinetics of the 4 circulating miRNAs suggested the changes started 17.5 to 6.8 months prior to HCC detection. These data establish these 4 circulating miRNAs as potential sentinels for preneoplastic lesions or early-stage HCC.

60 APPLIED LIFE SCIENCES↗

BioNutrients-3: Precision Fermentation, Pasteurization, and Pathogen Detection - Towards Safe Fermentation and Production of Nutrients in Space

The BioNutrients (BN) project is developing a microbial manufacturing approach to supplement the NASA food system to address known nutrient degradation associated with long-term storage. BN uses synthetic biology to deliver high-value nutrients and therapeutics through genetic engineering of microbes and production of fermented food products like yogurt and kefir, in a fully dehydrated system. On-demand production of nutrients for human consumption requires rigorous safety protocols to ensure contaminants are not introduced during the fermentation process. The third iteration of the BN flight project, BN-3, further develops the BN project by investigating strategies for pathogen detection and pasteurization in microgravity. BN-3 will test the limits of pathogen detection using whole genome sequencing, standard microbial assays and the NASA Ames E-Nose, a volatile carbon nano tube-based sensor array, to detect unwanted microbes. BN-3 also expands on the number of nutrients produced in a single bioreactor to enhance efficiency of the system by combining production of B vitamins in conjunction with the carotenoids, beta-carotene and zeaxanthin. Serial production of food products through yogurt passaging, new updates to the fluorinated ethylene propylene bags to allow crew access via a straw, as well as use of a food safe pH indicator dye to indicate readiness of the food product, will further enhance the useability of this system. This presentation will provide status of the BN-3 flight project with the aim of advancing in-space biomanufacturing for on-demand microbially based food production for future space exploration.

Biomanufacturing↗

Mark 3 real-time fringe detection system

A RAM memory built into the Mark 3 decoder module allows the capture of 1 Megabit of data. Data may be collected either in real time or from a pre-recorded tape. Once collected, the data may be retrieved using a standard EIA serial data link. The data may be transmitted to a remote computer for cross correlation processing with similar data from other stations to verify fringes in real time. The data may also be analyzed by a local computer to verify phase calibration, bandpass, format, etc., during a Mark 3 observing session.

Levine, J. I.↗

Spectrally Dependent Radiometric Measurement Errors Due to Ccd Serial Pixel-to-Pixel Readout Interference in the Ocean Color Instrument of the NASA PACE Mission

The Ocean Color Instrument on NASA’s PACE mission is a 322 887 nm hyperspectral imager with 1 km x 1 km nadir spatial resolution and 5 nm spectral resolution utilizing charge-coupled devices (CCDs) operating in Time Delay Integration (TDI) mode where each TDI column represents a different wavelength in 0.625 nm increments. After TDI, the charge is moved into serial output pixels and read out. The spatial resolution requires an 8.5 MHz readout rate. This only allows 59 ns for the CCD reset and video to be asserted and settled before sampling. The response exhibits serial pixel-to-pixel readout interference due to the lack of full settling. Each serial pixel value has a dependence on the value of the preceding pixel value. This leads to a spectrally dependent radiometric measurement error of up to 0.3 %. We explain the operation of the detection system, the behavior of the interference, and show the resulting measurement error based on data from both ground testing and on-orbit characterization.

Remote Sensing↗