Search NASA⌕ Search

SEARCH · Search NASA

Results for “sewer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A 1-year study on SARS-CoV-2 variant shifts in wastewater using dPCR: comparison with clinical and GISAID data

Wastewater testing can be used to monitor SARS-CoV-2 infections in communities. Data from PCR-based wastewater testing are usually available to public health authorities within 5–7 days after excreta and other body fluids enter the sewer. While PCR-based methods can accurately detect and quantify SARS-CoV-2, sequencing-based methods are usually required to distinguish between variants, delaying the results and adding cost to the process. We developed and assessed a novel, customizable digital PCR (dPCR)-based genotyping method for SARS-CoV-2 variant detection in wastewater, which is more cost-effective, faster, and more accessible than sequencing. This approach was applied to more than 1,400 wastewater samples

Wilton, Rose↗

Transmittal of the Sandia National Laboratories/New Mexico Five-Day Report for the Accidental Slug Discharge at the Albuquerque Bernalillo County Water Utility Authority (ABCWUA) Industrial Wastewater Permit No. 2069 Outfall [Letter and Enclosure]

This letter represents the five-day written notification for elevated fluoride levels at the Building 858N, Acid Waste Neutralization (AWN) System in accordance with the ABCWUA Sewer Use and Wastewater Ordinance § 3-6-5(B), Reports of Potential Problems. This AWN System is covered under the ABCWUA Industrial Wastewater Permit No. 2069G. The immediate notification to the ABCWUA occurred at 21:42 on August 1, 2019.

54 ENVIRONMENTAL SCIENCES↗

Clean Condensing Gas Furnace

Natural gas furnaces are the most common space heating equipment in the U.S. residential and commercial building markets. However, current residential natural gas condensing furnaces generate substantial acidic condensate as well as significant emissions of sulfur oxides (SOx), nitrogen oxides (NOx), carbon monoxide (CO), hydrocarbons (HC), and methane (CH 4 ) contributing to environmental degradation of air, water, and soil. This report describes a novel solution to reduce the environmental impact of natural gas condensing furnaces based on the technology of a monolithic acidic gas reduction (AGR) catalyst for SOx trapping, NOx redox to nitrogen, and oxidation of formic acid, CO, HC, and CH 4 . The AGR technology offers the following benefits: (1) a neutral furnace condensate with a pH of ~7, allowing its safe release into the sewer system thus eliminating a second drainage system; (2) trapping and removing nearly all SOx emissions; (3) NOx emissions nearly at nearly 1-2 ng/J, more than 95% lower than new emissions standards in California; (4) the use of a low-cost heat exchanger as a condensing heat exchanger (HX) since the condensate is not acidic, avoiding the need for expensive stainless steel alloys; and (5) unburnt fuel energy recovery to boost efficiency.The AGR component and AGR-enabled furnace performance were broadly tested to determine their effects on long-term reliability and durability, as well as SOx storage and regeneration activity. The AGR regeneration does not impair the performance in achieving neutral condensate and ultra-low NOx emissions, and the AGR catalyst subjected to regeneration activities continued to function well and achieved slightly better annual fuel utilization efficiency (AFUE). The 400-hour reliability and durability test of the retrofitted condensing furnace with the AGR component shows that the furnace unit still achieves a neutral furnace condensate with a pH of ~7 and enables 0~3 ng/J of NOx emissions. However, the 400-hour operation slightly degraded the AFUE because of soot particle accumulation caused by frequent incomplete combustion owing to inappropriate condensate drainage during testing. Thus, proper condensate drainage is critical for AGR-enabled furnaces. Furthermore, neutron computed tomography was employed to survey the aged AGR component and demonstrate high-resolution 2D and 3D representations for the nondestructive diagnosis of the AGR component. The tomography showed that the AGR component did not deform or suffer broken AGR channels. A new AGR catalyst with low precious metal loading was preliminarily explored to identify a pathway of optimizing AGR material loading and maximizing acidic gas reduction at low cost. The new AGR component can reduce precious metal loading by 38% and still achieve neutral condensate and ultralow NOx emissions. The furnace with the AGR component of low Pt/Rh loading enables a maximum AFUE of 97%, which is meaningfully higher than the original furnace. Long-duration testing for the furnace enabled with the low precious metal loading AGR component will be vital in future research. Although the current work demonstrates a proof of concept for the AGR-enabled furnace, the AGR assembly needs to be optimized and integrated into the design of new OEM furnace products. Furthermore, the AGR technology can be applied not only for residential gas furnaces, but also for commercial rooftop units, gas heat pumps, gas-fired water heaters, combustion boilers, and other systems.

03 NATURAL GAS↗

Wet Waste Hydrothermal Liquefaction and Biocrude Upgrading to Hydrocarbon Fuels: 2022 State of Technology

Data from Pacific Northwest National Laboratory’s (PNNL) conversion hydrothermal liquefaction (HTL) program for wet waste was used to update the pathway techno-economic analysis (TEA) for the fiscal year 2022 State of Technology (2022 SOT). Figure S.1 shows the modeled minimum fuel selling price (MFSP) for the 2022 SOT, along with the previous years’ SOTs (Snowden-Swan et al. 2020, 2021, 2022). These costs are for a HTL plant scale of 110 dry ton/day sludge feed and a larger centralized upgrading plant scale of 38 million gallons/year biocrude feed, commensurate with the design case. All costs were updated to 2020 dollars. Corresponding cost breakdowns and technical parameters for each case are given in Appendix B. In previous years’ analyses options with and without ammonia (NH 3 ) stripping treatment of the HTL aqueous phase recycle stream were included in the analysis to account for cases with direct recycle of untreated HTL aqueous phase back to the wastewater treatment plant. In the FY21 SOT assessment however, system boundaries for the analysis were adjusted to reflect separate ownership/operatorship for the HTL plant and with that, nutrient surcharge fees associated with disposal of the aqueous phase wastewater to a municipal sewer system were incorporated to provide an improved accounting of true disposal costs for a standalone plant. With these changes, there is no significant cost difference between the case including ammonia removal and the case excluding ammonia removal and therefore the “no NH3 removal” options will not be included in the 2022 and future SOTs.

09 BIOMASS FUELS↗

Housing Energy Connection Project (Final Technical Report)

This project expanded existing medium-voltage distribution to 33 households, a daycare, a mechanical shop, irrigation pumps, and a sewer lift station, all of which previously received electric service from the local electric utility. As part of the project, automatic meter reading (AMR) and advanced metering infrastructure (AMI) was installed to allow the Tribe to set up its own electric metering like a utility. The primary objective of this project was to expand the Tribe-owned electrical distribution to provide highly reliable electrical service to these existing loads. The objective was successfully met after project completion. The project reduced high costs for electric energy previously supplied by the utility, by supplanting utility-supplied electric power with Tribe-generated electric power. The project gave the Tribe greater independence from traditional power sources and provided jobs for the community.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cost Evaluation of Alternative Radioisotope Disposal Methods at the Livermore Site

The purpose of this cost evaluation was to investigate a hypothetical in which radioisotopes were no longer permitted in the City of Livermore sanitary sewer. Three alternative methods were proposed to determine estimated costs and compare current practice costs to the latter. An assumption from the initial steps of the analysis was significant cost savings would be found with the alternative methods.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Water at the Research and Education Complex [Poster]

Purpose: To identify the management methods for stormwater, sanitary sewer, and potable water throughout the facilities at the Research and Education Complex (REC) using drawings and written documents. To confirm the locations and status of wells located throughout the REC. To compile appropriate documentation that relates to water for each facility at the REC, verify that documentation is accurate, and create any new documentation that is necessary through field verification.

54 ENVIRONMENTAL SCIENCES↗

Soil Sampling Results for Delineating BH-056 for Partial Closure of Solid Waste Management Unit #16

The U.S. Department of Energy/National Nuclear Security Administration (DOE/NNSA) and National Technology & Engineering Solutions of Sandia, LLC (NTESS), the management and operating contractor for Sandia National Laboratories/California (SNL/CA), has prepared this addendum to Soil Sampling Results for Closure of a Portion of Solid Waste Management Unit #16 to report the results of additional soil sampling relating to the closure of a portion of Solid Waste Management Unit (SWMU) #16. This additional sampling was in response to a request by the San Francisco Bay Regional Water Quality Control Board (SFRWQCB) in their letters dated February 16 and August 18, 2022 relating to the detection of the benzidine above the defined project action level in a soil sample collected adjacent to the sanitary sewer line in borehole BH-056 (SFRWQCB, 2022A; 2022b).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Semiannual Categorical Process Report - January Through June 2023

The Sandia National Laboratories, in California (SNL/CA) is a research and development facility, owned by the U.S. Department of Energy’s National Nuclear Security Administration agency (DOE/NNSA). The laboratory is located in the City of Livermore (the City) and is comprised of approximately 410 acres. The SNL/CA facility is operated by National Technology and Engineering Solutions of Sandia, LLC (NTESS) under a contract with the DOE/NNSA. The DOE/ NNSA’s Sandia Field Office (SFO) oversees the operations of the site. North of the SNL/CA facility is the Lawrence Livermore National Laboratory (LLNL), in which SNL/CA’s sewer system combines with before discharging to the City’s Publicly Owned Treatment Works (POTW) for final treatment and processing. The City’s POTW authorizes the wastewater discharge from SNL/CA via the assigned Wastewater Discharge Permit #1251 (the Permit), which is issued to the DOE/NNSA’s main office for Sandia National Laboratories, located in New Mexico (SNL/NM). The Monitoring and Reporting Condition 2.B of the Permit requires compliance with the semiannual reporting requirements contained in federal categorical pretreatment standards regulations (40 CFR 403.12). These regulations set numerical limits on the concentration of pollutants allowed to discharge from certain categories of industrial processes. This report is submitted to the City to satisfy this reporting requirement.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Wellbore Fracture Imaging Using Inflow Detection Measurements

One of the most striking measurements taken during DOE’s EGS Collab project at the 4850-foot depth location was the so-called ‘sewer cam’, which enabled direct visualization of the flow of water into the production well through fractures during the stimulation. The ability to see directly which fractures were flowing and (roughly) how much was a breakthrough in understanding the topology of the created fracture network. Achieving this kind of fracture flow imaging at FORGE would be more challenging because of the 225°C temperature, but equally or even more valuable if it could be achieved. In 2017, a joint project between Sandia and Stanford developed a downhole tool concept to measure the enthalpy of multiphase fluid entering a geothermal well from individual fractures (Gao et al., 2017). For the FORGE project, measuring enthalpy is of less interest because the fluid is expected to be single-phase liquid water. However, the foundation of the device was the measurement of chloride ion concentration, which could form the basis for a direct measurement of inflow from fractures. During the 2017 project, this novel chloride sensing system was implemented into a laboratory test instrument, and we confirmed the capability of the system to measure the ion concentration of fluid entering a model wellbore through a small entry port. The wellbore was a 6-inch diameter model well, and the port was approximately 0.08 inch (2mm) in diameter. The device could measure the chloride concentration accurately even when the well was flowing in a bubbly flow. Given its accuracy, the tool should be able to identify locations of water entering the wellbore even if the ion concentration differs only slightly from that of the water in the well. It is likely that different fractures may flow slightly different chloride concentrations, which would make it feasible to detect individual fractures as well as to estimate the volume of their flow. Ultimately, we could also recognize different fractures flowing back significantly different ion concentrations after fracturing in the FORGE wells. This could be realized by adding different ions in the fracturing fluids in different fractures created at different stages of stimulation (and modifying the tool to include different ion specificity). Sandia’s tool was shown during the study to have the capability to withstand the 225°C temperature, and the electrochemical sensing elements were tested in the laboratory to 225°C at 1500 psia for 24 hours. An early implementation of the fully integrated downhole electrochemical tool, including high-temperature electronics, robust housing, and wireline truck interface, had previously been constructed and tested successfully at Sandia; thus, hardware development tasks focused on advancing the technology readiness level (TRL) of this promising technology for FORGE deployment, rather than on developing a new scientific basis for its operation. The data collection electronics in this tool allowed for several other sensors (pressure, temperature, flow spinner) to be implemented in parallel as well. The research was a new collaboration between Stanford and Sandia to modify and refine the tool for FORGE deployment, to make the downhole measurements, and to characterize the evolving fractures.

15 GEOTHERMAL ENERGY↗

Primer to SWIFt 2.0 Technical Information Sheets

More than 16,000 publicly owned municipal wastewater treatment plants (WWTPs) in the U.S. treat a wide range of wastewater (WW) flows ranging from <0.5 to >200 MGD. Municipal WWTPs act as the last barrier before exposure to water-borne diseases and contaminants, thus serving as a critical infrastructure protecting human health and the environment. A recent survey by the American Society of Civil Engineers assigned the U.S.’s WW infrastructure a grade of D+ because of the number of improvements needed for end-of-life infrastructure with operating conditions being over or under design capacities. With increasing population growth and urbanization, the municipal WW sector needs to grow resiliently and sustainably to accommodate increasing sewer flows in the wake of new infrastructure needs and global priorities. In addition, this growth will be affected by rising concerns over constrained resources (e.g., electricity, energy, and water) and regulations. This necessitates molding the WW sector toward sustainability- and resiliency-related planning and innovations to address current and future needs while simultaneously producing profitable by-products.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Extreme Decentralized Water Treatment: Exploring the Future of Premise-Scale Water Treatment and Reuse

Access to an adequate quantity of piped water and management of wastewater produced in homes and businesses is an expectation of city dwellers in wealthy countries, and an aspiration for many people living in rapidly developing cities in low- and middle-income countries. It is also crucial to public health and protection of the environment. For well over a century, municipal drinking water provision and wastewater management have been made possible by large investments in centralized systems in which fresh water passes through a small number of drinking water treatment plants before being distributed through a vast underground pipe network to buildings throughout the city (Sedlak 2014). After it is used, wastewater is collected in underground sewers that route it to treatment plants prior to its discharge to the environment. In some water-stressed cities, a fraction of the treated wastewater undergoes additional treatment prior to reuse. This recycled water often is returned to users through another dedicated water distribution system, which is designated in many places with purple pipes (non-potable water reuse). Alternatively, treated wastewater may be subjected to advanced treatment (e.g., reverse osmosis followed by advanced oxidation) prior to being returned to the drinking water supply (potable water reuse).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electrochemical testing of metals for petroleum wastewater monitoring

The purpose of this project was to determine the feasibility of ion-selective electrode (ISE) as compared to x-ray fluorescence (XRF) for determining the concentrations of metal ions in petroleum wastewater. ISEs for silver and cadmium were tested in a laboratory under increasingly realistic conditions, then deployed in the sewer wastewater monitoring complex to simulate a petroleum wastewater system. By verifying the ISE calibration after wastewater exposure and comparing its measurements to the XRF systems within the wastewater monitoring system, we determined that the ISE is more sensitive but less feasible for use in live wastewater monitoring due to fouling concerns.

Energy - Petroleum↗

A Preliminary Assessment of ERTS Imagery for Marine Resources

The application of ERTS-1 imagery to identifying marine resources is discussed. Specific reference is made to the use of ERTS-1 for observing the onset of the spring growing season in the ocean while it occurs. ERTS-1 data is used for the following purposes: (1) location of large areas of seasonally variable biological activity, (2) measurement of water depth in shallow seas, (3) monitoring of sewer discharges, (4) assessment of erosion damage to beaches and shoreline installations, and (5) navigation through ice-filled waterways.

Ewing, G. C.↗

Application of remote sensing to study nearshore circulation

Immediate use of drogued buoy tracking was made when the Virginia State Highway Department requested assistance in selecting the best route for a new bridge-tunnel complex across the James River at Newport News. The result was that the Highway Department acted and chose a preferred route from several alternatives. It was also observed that the drogues did not follow the channel as predicted by the James River hydraulic model. This permitted telling the Navy why it is that part of their channel always silts up. The Hampton Roads Sanitation District asked help locate the best route and position of an ocean sewer outfall. Biological activities are focused primarily on delineating biological interaction between the marsh and continental shelf waters on Virginia's Eastern Shore. Information derived is helpful in categorizing the relative biological value of different marsh areas so that meaningful use and management decisions can be made concerning their eventual disposition.

Welch, C. S.↗

Development of a household waste treatment subsystem, volume 1

The domestic waste treatment subsystem was developed to process the daily liquid and non-metallic solid wastes provided by a family of four people. The subsystem was designed to be connected to the sewer line of a household which contained water conservation features. The system consisted of an evaporation technique to separate liquids from solids, an incineration technique for solids reduction, and a catalytic oxidizer for eliminating noxious gases from evaporation and incineration processes. All wastes were passed through a grinder which masticated the solids and deposited them in a settling tank. The liquids were transferred through a cleanable filter into a holding tank. From here the liquids were sprayed into an evaporator and a spray chamber where evaporation occurred. The resulting vapors were processed by catalytic oxidation. Water and latent energy were recovered in a combination evaporator/condenser heat exchanger. The solids were conveyed into an incinerator and reduced to ash while the incineration gases were passed through the catalytic oxidizer along with the processed water vapor.

Gresko, T. M.↗

Dynamics of suspended sediment plumes in Lake Ontario

The author has identified the following significant results. Two unusual turbidity features were detected in imagery obtained over Lake Ontario on September 19, 1973. The location of a submerged sewer outfall was detected in frame 1423-15224-5 about 2 kilometers offshore opposite a treatment plant serving Rochester, New York. The other feature was a thermal heat plume made visible by an erosive eastward moving longshore current. The thermal plume, which extended about 3 kilometers into the lake, results from the discharge of cooling water from a nuclear power plant located 20 miles east of Rochester, New York. Under an offshore wind field, the outer edge of the Niagara River plume extended 30 kilometers into Lake Ontario on September 3, 1973. By way of contrast, a strong west-northwest wind on April 29, 1973, confined the plume to about 3 kilometers of the lake's south shore. The size of the Genesee River plume is largely dependent on discharge. During the spring high flow season, the plume extended over 22 square kilometers of the lake's surface on May 16, 1973. As runoff dwindled with the approach of summer, the plume contracted to less than 1 square kilometer in area by mid-July.

Pluhowski, E. J.↗