Search NASA⌕ Search

SEARCH · Search NASA

Results for “shape analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Marine Animal Classification With Correntropy-Loss-Based Multiview Learning

To analyze marine animals' behavior, seasonal distribution, and abundance, digital imagery can be acquired by a camera or a Lidar. Depending on the quantity and properties of acquired imagery, the animals are characterized as either features (shape, color, texture, etc.) or dissimilarity matrices derived from different shape analysis methods (shape context, internal distance shape context, etc.). For both cases, multiview learning is critical in integrating more than one set of feature/dissimilarity matrix for higher classification accuracy. This paper adopts correntropy loss as the cost function in multiview learning, which has favorable statistical properties for rejecting noise. For the case of features, the correntropy-loss-based multiview learning and its “entrywise” variation are developed based on the multiview intact space learning algorithm. For the case of dissimilarity matrices, the robust Euclidean embedding algorithm is extended to its multiview form with the correntropy loss function. Results from simulated data and real-world marine animal imagery show that the proposed algorithms can effectively enhance classification rate as well as suppress noise under different noise conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Side feeding patterns and nuclear lifetime determinations by the Doppler shift attenuation method in ({alpha},n{gamma}) reactions

{gamma} rays were measured at several angles in both singles and coincidence mode in the {sup 119}Sn({alpha},n{gamma}){sup 122}Te reaction at 15 MeV on a thick target. Lifetimes of excited states in {sup 122}Te were determined from a Monte Carlo Doppler shift attenuation method (DSAM) analysis of the Doppler broadened lines shapes of {gamma} rays de-exciting the levels. A comparison of several deduced lifetimes with recent results obtained with the (n,n{sup '}) reaction allowed us to validate the choice of a parameter used to calculate the contribution of the side feeding times. The ingredients of the DSAM line-shape analysis (stopping power, description of instrumental line shapes, and side feeding evaluation) are presented in some detail. It is concluded that with proper treatment of side feeding, a DSAM line-shape analysis of peaks in singles or coincidence spectra obtained following the ({alpha},n{gamma}) reaction is able to provide rather accurate values for the lifetimes of levels with low and medium spins.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis techniques for background rejection at the MAJORANA DEMONSTRATOR

The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, 40- kg modular HPGe detector array to search for neutrinoless double beta decay in {sup 76}Ge. In view of the next generation of tonne-scale Ge-based 0νβ β-decay searches that will probe the neutrino mass scale in the inverted-hierarchy region, a major goal of the MAJORANA DEMONSTRATOR is to demonstrate a path forward to achieving a background rate at or below 1 count/tonne/year in the 4 keV region of interest around the Q-value at 2039 keV. The background rejection techniques to be applied to the data include cuts based on data reduction, pulse shape analysis, event coincidences, and time correlations. The Point Contact design of the DEMONSTRATOR’s germanium detectors allows for significant reduction of gamma background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement Of The Neutron Spectrum Of A DD Electronic Neutron Generator

A Cuttler-Shalev (C-S){sup 3}He proportional counter has been used to measure the energy spectrum of neutrons from a portable deuterium-deuterium electronic neutron generator. To improve the analysis of results from the C-S detector digital pulse shape analysis techniques have been used to eliminate neutron recoil artifacts in the recorded data. Data was collected using a 8-GHz, 10-bit waveform digitizer with its full scale corresponding to approximately 6-MeV neutrons. The measurements were made with the detector axis perpendicular to the direction of ions in the ENG in a plane 0.5-m to the side of the ENG, measuring neutrons emitted at an angle from 87.3 deg. to 92.7 deg. with respect to the path of ions in the ENG. The system demonstrated an energy resolution of approximately 0.040 MeV for the thermal peak and approximately 0.13 MeV at the DD neutron energy. In order to achieve the ultimate resolution capable with this type of detector it is clear that a higher-precision digitizer will be needed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The analysis of shape data including normalization and the impact on prompt fission neutron spectrum measurements

While measurements of physical quantities contain an intrinsic absolute scale based on details of the experiment, sometimes only the value of each measured data point relative to the others, i.e., the shape, is of interest. Additionally, in contrast to absolute measurements of quantities like nuclear cross sections, shape measurements are unique in that the result is contained entirely in the relative value of each measured point with respect to all others. This fundamental attribute of shape data is sometimes discussed by data evaluators, but it is common that shape data are reported by experimenters with covariances directly from the raw data as though an absolute measurement has been performed, thereby misrepresenting the true knowledge of the measured shape. A normalization procedure must be carried out including careful covariance propagation in order to accurately represent the uncertainty in a measured shape. Known consequences of this procedure, such as the exclusion of constant fully-correlated uncertainties, are sometimes applied ad hoc to shape data. However, normalization also produces features of shape data that are otherwise difficult to apply, such as partial exclusion of strongly-correlated uncertainty sources, a redistribution of uncertainties across data points, and consistency of the covariance matrix obtained when combining separate shape measurements. In this study all of the above features are shown in a generalized fashion and exhibited using prompt fission neutron spectrum data from the Chi-Nu experiment with recommendations for analysis of future shape measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear signal simulation applied to gas ionizing chambers

Particle transport codes used in detector simulation allow the calculation of the energy deposited by charged particles produced following an interaction. The pulses temporal shaping is more and more used in nuclear measurement into pulse shape analysis techniques. A model is proposed in this paper to simulate the pulse temporal shaping and the associated noise level thanks to the output track file PTRAC provides by Monte-Carlo particle transport codes. The model has been dedicated to ion chambers and more especially for High Pressure Xenon chambers HPXe where the pulse shape analysis can resolve some issues regarding with this technology as the ballistic deficit phenomenon. The model is fully described and an example is presented as a validation of such full detector simulation. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PERFORMING DIAGNOSTICS ON THE SPALLATION NEUTRON SOURCE VISION BEAM LINE TO ELIMINATE HIGH VIBRATION LEVELS AND PROVIDE A SUSTAINABLE OPERATION

The Spallation Neutron Source (SNS) at the Oak Ridge National Laboratory (ORNL) provides variable energy neutrons for a variety of experiments. The neutrons proceed down beam lines to the experiment hall, which houses a variety of experiments and test articles. Each beam line has one or more neutron choppers which filter the neutron beam based on the neutron energy by using a rotating neutron absorbing material passing through the neutron beam. Excessive vibration of the Vision beam line, believed to be caused by the T0 chopper, prevented the Vision beam line from operating at full capacity. This problem had been addressed several times by rebalancing/reworking the T0 beam chopper but the problem stubbornly persisted. To determine the cause of the high vibration, dynamic testing was performed. Twenty-seven accelerometer and motor current channels of data were collected during drive up, drive down, coast down, and steady-state conditions; resonance testing and motor current signature analysis were also performed. The data was analyzed for traditional mechanical/machinery issues such as misalignment and imbalance using time series analysis, frequency domain analysis, and operating deflection shape analysis. The analysis showed that the chopper base plate was experiencing an amplified response to the excitation provided by the T0 beam chopper. The amplified response was diagnosed to be caused by higher than expected base plate flexibility, possibly due to improper grouting or loose floor anchors. Based on this diagnosis, a decision was made to dismantle the beam line chopper and remount the base plate. Neutron activation of the beam line components make modifications to the beam line especially expensive and time consuming due to the radiation handling requirements, so this decision had significant financial and schedule implications. It was found that the base plate was indeed loose because of improper grouting during its initial installation. The base plate was modified by splitting it into multiple sections, isolating the T0 chopper from the rest of the beam line, and each section was then reinstalled and re-grouted. After these modifications, the vibration levels were reduced by a factor of 30. The reduction in vibration level was sufficient to allow the Vision beam line to operate at full capacity for the first time since its completed construction date.

: Diagnostics↗

Optical properties of MgZnO alloys: Excitons and exciton-phonon complexes

The characteristics of the excitonic absorption and emission around the fundamental bandgap of wurtzite Mg{sub x}Zn{sub 1-x}O grown on c-plane sapphire substrates by plasma assisted molecular beam epitaxy with Mg contents between x = 0 and x = 0.23 are studied using spectroscopic ellipsometry and photoluminescence (PL) measurements. The ellipsometric data were analyzed using a multilayer model yielding the dielectric function (DF). The imaginary part of the DF for the alloys exhibits a pronounced feature which is attributed to exciton-phonon coupling (EPC) similar to the previously reported results for ZnO. Thus, in order to determine reliable transition energies, the spectral dependence is analyzed by a model which includes free excitonic lines, the exciton continuum, and the enhanced absorption due to EPC. A line shape analysis of the temperature-dependent PL spectra yielded in particular the emission-related free excitonic transition energies, which are compared to the results from the DF line-shape analysis. The PL linewidth is discussed within the framework of an alloy disorder model.

36 MATERIALS SCIENCE↗

Automated divertor target design by adjoint shape sensitivity analysis and a one-shot method

As magnetic confinement fusion progresses towards the development of first reactor-scale devices, computational tokamak divertor design is a topic of high priority. Presently, edge plasma codes are used in a forward approach, where magnetic field and divertor geometry are manually adjusted to meet design requirements. Due to the complex edge plasma flows and large number of design variables, this method is computationally very demanding. On the other hand, efficient optimization-based design strategies have been developed in computational aerodynamics and fluid mechanics. Such an optimization approach to divertor target shape design is elaborated in the present paper. A general formulation of the design problems is given, and conditions characterizing the optimal designs are formulated. Using a continuous adjoint framework, design sensitivities can be computed at a cost of only two edge plasma simulations, independent of the number of design variables. Furthermore, by using a one-shot method the entire optimization problem can be solved at an equivalent cost of only a few forward simulations. The methodology is applied to target shape design for uniform power load, in simplified edge plasma geometry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Searches for New Physics With Muon Conversion at Fermilab and Triboson Production at the LHC

We report on several efforts to search for physics beyond the standard model of particle physics at broad energy scales. The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the muon to electron conversion process, which is suppressed in the Standard Model. Mu2e will be operated at a low energy, yet can probe New Physics at very high mass scales (O(1e3 - 1e4 ) TeV). At high energies, the CMS experiment at the CERN LHC continues to deliver an impressive suite of Standard Model measurements and limits on a variety of New Physics signatures. Mu2e is under construction and slated to collect its first physics data in the coming years. This thesis describes work done during the construction phase of Mu2e and focuses on two critical areas: magnetic field modeling and statistical analysis. We describe a novel method for field modeling which we validate using a simulated dataset representing the expected magnetic field in the Detector Solenoid. This method blends a standard least-squares fitting technique that utilizes physically motivated analytical model functions with a novel physics informed network that is constructed to obey Maxwell’s equations. We show the technique can model the field with an accuracy of 10−7 despite the presence of injected noise in the pseudo-measurements at the 10−5 level. We then present preliminary results of the calibration of 3D Hall probes at the sub-10−4 level. These probes will be used to directly measure the Mu2e Detector Solenoid magnetic field on a sparse grid; these measurements serve as the input to the field model fitting. Finally, we describe the first implementation of both an unbinned shape analysis and a Bayesian interpretation applied to Mu2e pseudo-data. Up to 20% tighter limits can be set by the shape analysis compared to a standard cut & count analysis. The AlCap experiment collected data at PSI in 2015 to measure several important quantities related to nuclear muon capture on an aluminum target, which is a significant background process for Mu2e. The neutron emission from muon capture can introduce background hits in the Mu2e detectors and can increase radiation damage in various elements of the apparatus. We present measurements of the neutron group fluence and mean neutron multiplicity for muon capture on aluminum nuclei. Finally, we discuss an analysis of triboson production at CMS using an Effective Field Theory framework. Standard Model triboson production, which was first observed at CMS in 2020, has a relatively small cross section and provides direct access to both anomalous triple gauge couplings and quartic gauge couplings. These couplings, interpreted in the Standard Model Effective Field Theory, are studied in the present work. We target the boosted regime where the background rate is low and yields are enhanced when dimension-6 and dimension-8 Wilson coefficients are non-zero. We do not observe an excess in the data and therefore set bounds on the Wilson coefficients. For dimension-6 coefficients the tightest observed (expected) bounds are set on cW /Λ2 where Λ is the mass scale of new physics; the bounds are [−0.13, 0.12] TeV−2 ([−0.12, 0.12] TeV−2 ) at 95% CL. The tightest bounds in dimension-8 are set on fT,0 / Λ4 ; the observed (expected) bounds at 95% CL are [−0.63, 0.69] TeV−4 ([−0.54, 0.62] TeV−4 ). Additional results are presented which include scenarios where multiple Wilson coefficients are non-zero, the application of signal model clipping to address unitarity violation in Effective Field Theories, and a novel template fit developed for easier reinterpretation of our results.

Kampa, Cole Erik [Northwestern U. (main)] (ORCID:0↗

Automated analysis of hot spot X-ray images at the National Ignition Facility

At the National Ignition Facility, the symmetry of the hot spot of imploding capsules is diagnosed by imaging the emitted x-rays using gated cameras and image plates. The symmetry of an implosion is an important factor in the yield generated from the resulting fusion process. The x-ray images are analyzed by decomposing the image intensity contours into Fourier and Legendre modes. This paper focuses on the additional protocols for the time-integrated shape analysis from image plates. For implosions with temperatures above ∼4 keV, the hard x-ray background can be utilized to infer the temperature of the hot spot.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RADIOXENON MEASUREMENTS WITH THE PHOSWATCH DETECTOR SYSTEM

Many of the radioxenon detector systems used in the International Monitoring System and in other applications employ beta/gamma coincidence detection to achieve high sensitivity. In these systems, the coincidence detection is implemented by requiring simultaneous signals from separate beta and gamma detectors. While very sensitive to small amounts of radioxenon, this approach requires careful calibration and gain matching of several detectors and photomultiplier tubes. An alternative approach is the use of a phoswich detector in which beta-gamma coincidences are detected by pulse shape analysis. The phoswich requires only a single photomultiplier tube and thus is easier to set up and calibrate, and can be assembled into a more compact and robust system. In the past, we have developed a COTS detector system, named PhosWatch, which consists of a CsI(Tl)/BC-404 phoswich detector, digital readout electronics, and on-board software to perform the pulse shape analysis. Several units of this system have been manufactured and are now evaluated at several radioxenon research laboratories. In this paper, we will report results from production tests and some of the evaluations, including a side-by-side comparison of a SAUNA detector and a PhosWatch system using atmospheric radioxenon samples. In addition, we will show initial results obtained with a higher speed version of the readout electronics, digitizing at 500 MHz and thus able to better resolve the fast pulses from the BC-404.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Testing Scale-Dependent Modified Gravity with DESI DR1

The Dark Energy Spectroscopic Instrument (DESI) provides an unprecedented opportunity to test deviations from general relativity (GR) that introduce a new physical scale within its redshift range. Using the connection between a Yukawa-like potential and the Hu-Sawicki $f(R)$ model, we place strong constraints on the range of a hypothetical fifth force mediated by a massive scalar field. We analyze the power spectrum measurements from DESI Data Release 1 using a baseline EFT model that employs the fkpt approach for the loop integrals. We find no evidence for deviations from GR and obtain the constraint $\log_{10} |f_{R_0}| < -4.59$ (95% C.L.). This corresponds to an upper bound at redshift zero on the scale at which corrections to GR become important, $λ< 17.81$ Mpc, or equivalently, a lower bound on the mass of the additional gravitational mediator of $m_ϕ> 3.60 \times 10^{-31}$ eV. We find that the modified gravity parameter $f_{R_0}$ is largely orthogonal to the cosmological parameters in the model, such that no additional projection effects relative to the GR case are introduced in this Full-Shape analysis. Furthermore, a second modified gravity parameter, the power index $n$, which modulates the time-variation of the associated mass, is found to be consistent with previous analyses that fixed it to unity. Adding DESI BAO data or other cosmological probes does not significantly change these results. The conclusions remain similar if the background evolution is described by evolving dark energy instead of a cosmological constant. Additionally, we test the robustness of the baseline model by varying the maximum wavenumber used in the Full-Shape analysis and analyzing the DESI targets separately. Finally, we analyze the degeneracies between the modified-gravity parameters and the sum of neutrino masses.

Gonzalez, D. [Guanajuato U.; UNAM, CCF] (ORCID:000↗

Shape error analysis for reflective nano focusing optics

Focusing performance of reflective x-ray optics is determined by surface figure accuracy. Any surface imperfection present on such optics introduces a phase error in the outgoing wave fields. Therefore converging beam at the focal spot will differ from the desired performance. Effect of these errors on focusing performance can be calculated by wave optical approach considering a coherent wave field illumination of optical elements. We have developed a wave optics simulator using Fresnel-Kirchhoff diffraction integral to calculate the mirror pupil function. Both analytically calculated and measured surface topography data can be taken as an aberration source to outgoing wave fields. Simulations are performed to study the effect of surface height fluctuations on focusing performances over wide frequency range in high, mid and low frequency band. The results using real shape profile measured with long trace profilometer (LTP) suggest that the shape error of {lambda}/4 PV (peak to valley) is tolerable to achieve diffraction limited performance. It is desirable to remove shape error of very low frequency as 0.1 mm{sup -1} which otherwise will generate beam waist or satellite peaks. All other frequencies above this limit will not affect the focused beam profile but only caused a loss in intensity.

43 PARTICLE ACCELERATORS↗

Background Model for the Majorana Demonstrator

The Majorana Collaboration is constructing a prototype system containing 40 kg of HPGe detectors to demonstrate the feasibility and potential of a future tonne-scale experiment to search for neutrinoless double-beta (0v BB) decay in 76Ge. In view of the requirement that the next generation of tonne-scale Ge-based 0vBB-decay experiment be capable of probing the neutrino mass scale in the inverted-hierarchy region, a major goal of theMajorana Demonstrator is to demonstrate a path forward to achieving a background rate at or below 1 cnt/(ROI-t-y) in the 4 keV region of interest around the Q-value at 2039 keV. This goal is pursued through a combination of a significant reduction of radioactive impurities in construction materials with analytical methods for background rejection, for example using powerful pulse shape analysis techniques profiting from the p-type point contact HPGe detectors technology. The effectiveness of these methods is assessed using Geant4 simulations of the different background components whose purity levels are constrained from radioassay measurements.

Cuesta, C.↗

DarkSide-20k: A 20 tonne two-phase LAr TPC for direct dark matter detection at LNGS

Abstract. Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LAr TPC) with an active (fiducial) mass of 23 t (20 t). This paper describes a preliminary design for the experiment, in which the DarkSide-20k LAr TPC is deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a cylindrical Water Cherenkov Veto (WCV). This preliminary design provides a baseline for the experiment to achieve its physics goals, while further development work will lead to the final optimization of the detector parameters and an eventual technical design. Operation of DarkSide-50 demonstrated a major reduction in the dominant 39Ar background when using argon extracted from an underground source, before applying pulse shape analysis. Data from DarkSide-50, in combination with MC simulation and analytical modeling, shows that a rejection factor for discrimination between electron and nuclear recoils of > 3 × 109 is achievable. This, along with the use of the veto system and utilizing silicon photomultipliers in the LAr TPC, are the keys to unlocking the path to large LAr TPC detector masses, while maintaining an experiment in which less than < 0.1 events (other than ?-induced nuclear recoils) is expected to occur within the WIMP search region during the planned exposure. DarkSide-20k will have ultra-low backgrounds than can be measured in situ, giving sensitivity to WIMP-nucleon cross sections of 1.2×10 -47 cm2 (1.1×10 -46 cm2) for WIMPs of 1TeV/c2 (10TeV/c2) mass, to be achieved during a 5 yr run producing an exposure of 100 t yr free from any instrumental background.

Aalseth, Craig E.↗

Optimization and analysis of shape of coaxial electrode for microwave plasma in water

The effect of the shape of the electrode to generate 2.45 GHz microwave plasma in pure water is examined. Three variations of a common coaxial electrode are proposed, and compared according to the power required for plasma ignition and the position of plasma ignition in pure water at 6 kPa using a high-speed camera. These coaxial electrodes are calculated using three-dimensional finite-difference time-domain method calculations. The superior shape of coaxial electrode is found to be one with a flat plane on the tip of the inner electrode and dielectric substance located below the tip of the outer electrode. The position of the plasma ignition is related to the shape of the coaxial electrode. By solving the heat-conduction equation of water around the coaxial electrode taking into account the absorption of the microwave energy, the position of the plasma ignition is found to be not where electric field is the largest, but rather where temperature is maximized.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Energy density functional analysis of shape coexistence in {sup 44}S

The structure of low-energy collective states in the neutron-rich nucleus {sup 44}S is analyzed using a microscopic collective Hamiltonian model based on energy density functionals (EDFs). The calculated triaxial energy map, low-energy spectrum and corresponding probability distributions indicate a coexistence of prolate and oblate shapes in this nucleus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗