Search NASA⌕ Search

SEARCH · Search NASA

Results for “shared error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Kip, Version 1.0

This high-performance ray tracing library provides very fast rendering, compact code, type flexibility via C++ 'generic programming' techniques, and ease of use through an application programming interface (API) that functions independently of any GUI, on-screen display, or other enclosing application. Kip supports constructive solid geometry models based on any of several built-in shapes and operators and allows for new, user-defined shapes and operators. Additional features include basic texturing, input/output of models using a simple human-readable file format with full error checking and detailed diagnostics, and support for shared data parallelism. Kip is written in pure, ANSI Standard C++, is entirely platform independent, and is very easy to use, as it requires no build system, configuration or installation scripts, wizards, special preprocessing, makefiles, or external libraries.

Staley, Martin↗

Practical Challenges and Failure Modes During Fabrication of Haynes 230 Micro-Pin Solar Receivers for High Temperature Supercritical Carbon Dioxide Operation

Printed circuit heat exchangers (PCHX) fabricated from high nickel alloys have shown promise as primary heat exchangers, recuperators, and solar receivers for high temperature and pressure supercritical carbon dioxide power cycles. There are numerous challenges in fabricating these devices including forming channel features, joining via diffusion or transient liquid phase bonding, and brazing/welding of headers. Commercial entities are understandably hesitant to share propriety best practices, and both commercial and non-commercial entities working on these components tend not to publically share failures and mistakes. However, sharing of this information could prevent similar costly errors and further the understanding of the coupled manufacturing, materials and mechanics issues in creating these components. Thus, in this paper, we document the challenges, failures, and mitigation methods uncovered in fabrication of prototype micro-pin based solar thermal receivers constructed of Haynes 230 and fabricated through a combination of photochemical machining (PCM), wire electrical discharge machining (EDM), transient liquid phase (TLP) bonding, vacuum brazing, and gas tungsten arc welding (GTAW). The receiver is designed to absorb concentrated solar fluxes greater than 140 W cm-2, while heating supercritical carbon dioxide from 550 °C to 720 °C at a pressure of 20 MPa to 25 MPa. The prototype receiver consists of a thin (~ 450 µm), Haynes 230 coversheet bonded to a 15 cm × 15 cm Haynes 230 micro-pin plate. The pieces are joined using a TLP bonding process with a nickel-phosphorus interlayer. Prior to bonding, micro-pins with height ~150 µm and diameter 300 µm are fabricated using PCM in the plate, and through slot features are made using wire EDM. Finally, flow headers are joined to the microchannel plate through a combination of vacuum brazing and GTAW. During hydrostatic proof testing, the prototype device failed when the coversheet delaminated from the pin array at a pressure of 290 bar. A failure analysis including scanning electron microscopy (SEM) to view failure sites and energy-dispersive X-ray spectroscopy (EDS) to evaluate elemental analysis of the failed areas was conducted. The failure modes can be broadly categorized as (1) failures potentially relating to reliquification of the transient liquid phase bonds between the micro-pins plate and coversheet during post-processing, (2) failures related to manufacturing defects, and (3) failures attributed to design.

14 SOLAR ENERGY↗

Lepton–Nucleus Interactions within Microscopic Approaches

This review paper emphasizes the significance of microscopic calculations with quantified theoretical error estimates in studying lepton–nucleus interactions and their implications for electron scattering and accelerator neutrino oscillation measurements. We investigate two approaches: Green’s Function Monte Carlo and the extended factorization scheme, utilizing realistic nuclear target spectral functions. In our study, we include relativistic effects in Green’s Function Monte Carlo and validate the inclusive electron scattering cross section on carbon using available data. We compare the flux-folded cross sections for neutrino-carbon scattering with T2K and MINER$v$ A experiments, noting the substantial impact of relativistic effects in reducing the theoretical curve strength when compared to MINER$v$ A data. Additionally, we demonstrate that quantum Monte Carlo-based spectral functions accurately reproduce the quasi-elastic region in electron scattering data and T2K flux-folded cross sections. By comparing results from Green’s Function Monte Carlo and the spectral function approach, which share a similar initial target state description, we quantify errors associated with approximations in the factorization scheme and the relativistic treatment of kinematics in Green’s Function Monte Carlo.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimal binning of correlated measurements

Experimental measurements are commonly represented on a discrete grid, requiring a balance between granularity and statistical noise. Two strategies have traditionally been used to improve such representations: selecting an appropriate bin width to control discretization error and applying kernel-based smoothing to suppress fluctuations. Despite their shared goal, these approaches have largely developed independently, without a unified statistical description of how discretization and correlation jointly determine measurement precision. Here, we extend the discussion of optimal interval averaging to a correlation-aware setting by Gaussian process regression, which explicitly accounts for correlations among neighboring bins. Starting from first principles, we derive the mean-squared error of discretized measurements and obtain closed-form asymptotic expressions for the optimal bin width and correlation length. When recast in reduced variables, the theory reveals distinct universal scaling laws governing the error in the correlation-free and correlation-controlled regimes. Characterized by intrinsically smooth intensity profiles and counting-based statistics, neutron scattering measurements are well suited for demonstrating the enhanced error contraction enabled by inter-bin correlations. We show that such improvement is achievable over the experimentally accessible Q-range and across multiple instruments and material systems. These results show that explicitly accounting for correlations systematically reshapes the limits of precision in discretized, noise-limited measurements. More broadly, the framework provides a transferable statistical foundation for optimizing data representation, inference, and experimental design across the physical and data sciences.

Tung, Chi-Huan [ORNL] (ORCID:0000000221972074)↗

Image-based spectral distortion correction for photon-counting x-ray detectors

Purpose: To investigate the feasibility of using an image-based method to correct for distortions induced by various artifacts in the x-ray spectrum recorded with photon-counting detectors for their application in breast computed tomography (CT). Methods: The polyenergetic incident spectrum was simulated with the tungsten anode spectral model using the interpolating polynomials (TASMIP) code and carefully calibrated to match the x-ray tube in this study. Experiments were performed on a Cadmium-Zinc-Telluride (CZT) photon-counting detector with five energy thresholds. Energy bins were adjusted to evenly distribute the recorded counts above the noise floor. BR12 phantoms of various thicknesses were used for calibration. A nonlinear function was selected to fit the count correlation between the simulated and the measured spectra in the calibration process. To evaluate the proposed spectral distortion correction method, an empirical fitting derived from the calibration process was applied on the raw images recorded for polymethyl methacrylate (PMMA) phantoms of 8.7, 48.8, and 100.0 mm. Both the corrected counts and the effective attenuation coefficient were compared to the simulated values for each of the five energy bins. The feasibility of applying the proposed method to quantitative material decomposition was tested using a dual-energy imaging technique with a three-material phantom that consisted of water, lipid, and protein. The performance of the spectral distortion correction method was quantified using the relative root-mean-square (RMS) error with respect to the expected values from simulations or areal analysis of the decomposition phantom. Results: The implementation of the proposed method reduced the relative RMS error of the output counts in the five energy bins with respect to the simulated incident counts from 23.0%, 33.0%, and 54.0% to 1.2%, 1.8%, and 7.7% for 8.7, 48.8, and 100.0 mm PMMA phantoms, respectively. The accuracy of the effective attenuation coefficient of PMMA estimate was also improved with the proposed spectral distortion correction. Finally, the relative RMS error of water, lipid, and protein decompositions in dual-energy imaging was significantly reduced from 53.4% to 6.8% after correction was applied. Conclusions: The study demonstrated that dramatic distortions in the recorded raw image yielded from a photon-counting detector could be expected, which presents great challenges for applying the quantitative material decomposition method in spectral CT. The proposed semi-empirical correction method can effectively reduce these errors caused by various artifacts, including pulse pileup and charge sharing effects. Furthermore, rather than detector-specific simulation packages, the method requires a relatively simple calibration process and knowledge about the incident spectrum. Therefore, it may be used as a generalized procedure for the spectral distortion correction of different photon-counting detectors in clinical breast CT systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photovoltaic System Health-State Architecture for Data-Driven Failure Detection

The timely detection of photovoltaic (PV) system failures is important for maintaining optimal performance and lifetime reliability. A main challenge remains the lack of a unified health-state architecture for the uninterrupted monitoring and predictive performance of PV systems. To this end, existing failure detection models are strongly dependent on the availability and quality of site-specific historic data. The scope of this work is to address these fundamental challenges by presenting a health-state architecture for advanced PV system monitoring. The proposed architecture comprises of a machine learning model for PV performance modeling and accurate failure diagnosis. The predictive model is optimally trained on low amounts of on-site data using minimal features and coupled to functional routines for data quality verification, whereas the classifier is trained under an enhanced supervised learning regime. The results demonstrated high accuracies for the implemented predictive model, exhibiting normalized root mean square errors lower than 3.40% even when trained with low data shares. The classification results provided evidence that fault conditions can be detected with a sensitivity of 83.91% for synthetic power-loss events (power reduction of 5%) and of 97.99% for field-emulated failures in the test-bench PV system. Finally, this work provides insights on how to construct an accurate PV system with predictive and classification models for the timely detection of faults and uninterrupted monitoring of PV systems, regardless of historic data availability and quality. Such guidelines and insights on the development of accurate health-state architectures for PV plants can have positive implications in operation and maintenance and monitoring strategies, thus improving the system’s performance.

photovoltaics↗

Dependence of Cosmological Constraints on Gray Photometric Zero-point Uncertainties of Supernova Surveys

Abstract Type Ia supernova (SN) measurements of the Hubble constant, H 0 ; cosmic mass density, Ω M ; and dark energy equation-of-state parameter, w , rely on heterogeneous SN surveys across three decades of observation. These distinct surveys may have undiagnosed, relative photometric zero-point errors. We determine the sensitivities of the SH0ES+Pantheon+ cosmological constraints to unknown gray systematics in the photometric zero-point calibration between the 19 surveys that comprise the Pantheon+ SN compendium. Varying the surveys’ gray zero-points simultaneously with cosmological parameters, we determine that the SH0ES+Pantheon+ measurement of H 0 is robust against gray intersurvey photometric miscalibration. Specifically, uncalibrated intersurvey systematics could represent a source of uncertainty no larger than 0.39 km s −1 Mpc −1 for H 0 . This modest increase in H 0 uncertainty could not account for the 7 km s −1 Mpc −1 “Hubble tension” between the SH0ES measurement of H 0 and the Planck ΛCDM-based inference of H 0 . However, the SH0ES+Pantheon+ best-fit values of Ω M and w are not robust against gray zero-point error, slipping by up to 0.16 and −0.63. Because measurements of Ω M and w depend on intrasurvey cross-band calibration, the hypothetical gray miscalibration underestimates the sensitivity of these measurements to zero-point miscalibration. Because the Pantheon+ compendium contains many surveys that share low- z Hubble flow (HF) and Cepheid-paired SNe, intersurvey photometric calibration errors do not significantly impede the joint use of SH0ES and Pantheon+ to measure H 0 to 1% accuracy. However, H 0 constraints that rely on one HF survey but numerous galactic distance calibration surveys are susceptible to intersurvey photometric miscalibration.

79 ASTRONOMY AND ASTROPHYSICS↗

Soluble limit and criticality of fermions in $\mathbb Z_2$ gauge theories

Quantum information theory and strongly correlated electron systems share a common theme of macroscopic quantum entanglement. In both topological error correction codes and theories of quantum materials (spin liquid, heavy fermion and high-$T_c$ systems), entanglement is implemented by means of an emergent gauge symmetry. Inspired by these connections, in this paper we introduce a simple model for fermions moving in the deconfined phase of a $\mathbb Z_2$ gauge theory by coupling Kitaev's toric code to mobile fermions. This permits us to exactly solve the ground state of this system and map out its phase diagram. Reversing the sign of the plaquette term in the toric code permits us to tune the ground state between an orthogonal metal and an orthogonal semimetal in which gapless quasiparticles survive despite a gap in the spectrum of original fermions. The small-to-large Fermi surface transition between these two states occurs in a stepwise fashion with multiple intermediate phases. By using a diagrammatic technique, we are able to explore physics beyond the integrable point to examine various instabilities of the deconfined phase and to derive the critical theory at the transition between deconfined and confined phases. We outline how the fermionic toric code can be implemented as a quantum circuit, thus providing an important link between quantum materials and quantum information theory.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

MO-B-BRB-00: Optimizing the Treatment Planning Process

The radiotherapy treatment planning process has evolved over the years with innovations in treatment planning, treatment delivery and imaging systems. Treatment modality and simulation technologies are also rapidly improving and affecting the planning process. For example, Image-guided-radiation-therapy has been widely adopted for patient setup, leading to margin reduction and isocenter repositioning after simulation. Stereotactic Body radiation therapy (SBRT) and Radiosurgery (SRS) have gradually become the standard of care for many treatment sites, which demand a higher throughput for the treatment plans even if the number of treatments per day remains the same. Finally, simulation, planning and treatment are traditionally sequential events. However, with emerging adaptive radiotherapy, they are becoming more tightly intertwined, leading to iterative processes. Enhanced efficiency of planning is therefore becoming more critical and poses serious challenge to the treatment planning process; Lean Six Sigma approaches are being utilized increasingly to balance the competing needs for speed and quality. In this symposium we will discuss the treatment planning process and illustrate effective techniques for managing workflow. Topics will include: Planning techniques: (a) beam placement, (b) dose optimization, (c) plan evaluation (d) export to RVS. Planning workflow: (a) import images, (b) Image fusion, (c) contouring, (d) plan approval (e) plan check (f) chart check, (g) sequential and iterative process Influence of upstream and downstream operations: (a) simulation, (b) immobilization, (c) motion management, (d) QA, (e) IGRT, (f) Treatment delivery, (g) SBRT/SRS (h) adaptive planning Reduction of delay between planning steps with Lean systems due to (a) communication, (b) limited resource, (b) contour, (c) plan approval, (d) treatment. Optimizing planning processes: (a) contour validation (b) consistent planning protocol, (c) protocol/template sharing, (d) semi-automatic plan evaluation, (e) quality checklist for error prevention, (f) iterative process, (g) balance of speed and quality Learning Objectives: Gain familiarity with the workflow of modern treatment planning process. Understand the scope and challenges of managing modern treatment planning processes. Gain familiarity with Lean Six Sigma approaches and their implementation in the treatment planning workflow.

60 APPLIED LIFE SCIENCES↗

MO-B-BRB-01: Optimize Treatment Planning Process in Clinical Environment

The radiotherapy treatment planning process has evolved over the years with innovations in treatment planning, treatment delivery and imaging systems. Treatment modality and simulation technologies are also rapidly improving and affecting the planning process. For example, Image-guided-radiation-therapy has been widely adopted for patient setup, leading to margin reduction and isocenter repositioning after simulation. Stereotactic Body radiation therapy (SBRT) and Radiosurgery (SRS) have gradually become the standard of care for many treatment sites, which demand a higher throughput for the treatment plans even if the number of treatments per day remains the same. Finally, simulation, planning and treatment are traditionally sequential events. However, with emerging adaptive radiotherapy, they are becoming more tightly intertwined, leading to iterative processes. Enhanced efficiency of planning is therefore becoming more critical and poses serious challenge to the treatment planning process; Lean Six Sigma approaches are being utilized increasingly to balance the competing needs for speed and quality. In this symposium we will discuss the treatment planning process and illustrate effective techniques for managing workflow. Topics will include: Planning techniques: (a) beam placement, (b) dose optimization, (c) plan evaluation (d) export to RVS. Planning workflow: (a) import images, (b) Image fusion, (c) contouring, (d) plan approval (e) plan check (f) chart check, (g) sequential and iterative process Influence of upstream and downstream operations: (a) simulation, (b) immobilization, (c) motion management, (d) QA, (e) IGRT, (f) Treatment delivery, (g) SBRT/SRS (h) adaptive planning Reduction of delay between planning steps with Lean systems due to (a) communication, (b) limited resource, (b) contour, (c) plan approval, (d) treatment. Optimizing planning processes: (a) contour validation (b) consistent planning protocol, (c) protocol/template sharing, (d) semi-automatic plan evaluation, (e) quality checklist for error prevention, (f) iterative process, (g) balance of speed and quality Learning Objectives: Gain familiarity with the workflow of modern treatment planning process. Understand the scope and challenges of managing modern treatment planning processes. Gain familiarity with Lean Six Sigma approaches and their implementation in the treatment planning workflow.

60 APPLIED LIFE SCIENCES↗

MO-B-BRB-02: Maintain the Quality of Treatment Planning for Time-Constraint Cases

The radiotherapy treatment planning process has evolved over the years with innovations in treatment planning, treatment delivery and imaging systems. Treatment modality and simulation technologies are also rapidly improving and affecting the planning process. For example, Image-guided-radiation-therapy has been widely adopted for patient setup, leading to margin reduction and isocenter repositioning after simulation. Stereotactic Body radiation therapy (SBRT) and Radiosurgery (SRS) have gradually become the standard of care for many treatment sites, which demand a higher throughput for the treatment plans even if the number of treatments per day remains the same. Finally, simulation, planning and treatment are traditionally sequential events. However, with emerging adaptive radiotherapy, they are becoming more tightly intertwined, leading to iterative processes. Enhanced efficiency of planning is therefore becoming more critical and poses serious challenge to the treatment planning process; Lean Six Sigma approaches are being utilized increasingly to balance the competing needs for speed and quality. In this symposium we will discuss the treatment planning process and illustrate effective techniques for managing workflow. Topics will include: Planning techniques: (a) beam placement, (b) dose optimization, (c) plan evaluation (d) export to RVS. Planning workflow: (a) import images, (b) Image fusion, (c) contouring, (d) plan approval (e) plan check (f) chart check, (g) sequential and iterative process Influence of upstream and downstream operations: (a) simulation, (b) immobilization, (c) motion management, (d) QA, (e) IGRT, (f) Treatment delivery, (g) SBRT/SRS (h) adaptive planning Reduction of delay between planning steps with Lean systems due to (a) communication, (b) limited resource, (b) contour, (c) plan approval, (d) treatment. Optimizing planning processes: (a) contour validation (b) consistent planning protocol, (c) protocol/template sharing, (d) semi-automatic plan evaluation, (e) quality checklist for error prevention, (f) iterative process, (g) balance of speed and quality Learning Objectives: Gain familiarity with the workflow of modern treatment planning process. Understand the scope and challenges of managing modern treatment planning processes. Gain familiarity with Lean Six Sigma approaches and their implementation in the treatment planning workflow.

60 APPLIED LIFE SCIENCES↗

MO-B-BRB-03: Systems Engineering Tools for Treatment Planning Process Optimization in Radiation Medicine

The radiotherapy treatment planning process has evolved over the years with innovations in treatment planning, treatment delivery and imaging systems. Treatment modality and simulation technologies are also rapidly improving and affecting the planning process. For example, Image-guided-radiation-therapy has been widely adopted for patient setup, leading to margin reduction and isocenter repositioning after simulation. Stereotactic Body radiation therapy (SBRT) and Radiosurgery (SRS) have gradually become the standard of care for many treatment sites, which demand a higher throughput for the treatment plans even if the number of treatments per day remains the same. Finally, simulation, planning and treatment are traditionally sequential events. However, with emerging adaptive radiotherapy, they are becoming more tightly intertwined, leading to iterative processes. Enhanced efficiency of planning is therefore becoming more critical and poses serious challenge to the treatment planning process; Lean Six Sigma approaches are being utilized increasingly to balance the competing needs for speed and quality. In this symposium we will discuss the treatment planning process and illustrate effective techniques for managing workflow. Topics will include: Planning techniques: (a) beam placement, (b) dose optimization, (c) plan evaluation (d) export to RVS. Planning workflow: (a) import images, (b) Image fusion, (c) contouring, (d) plan approval (e) plan check (f) chart check, (g) sequential and iterative process Influence of upstream and downstream operations: (a) simulation, (b) immobilization, (c) motion management, (d) QA, (e) IGRT, (f) Treatment delivery, (g) SBRT/SRS (h) adaptive planning Reduction of delay between planning steps with Lean systems due to (a) communication, (b) limited resource, (b) contour, (c) plan approval, (d) treatment. Optimizing planning processes: (a) contour validation (b) consistent planning protocol, (c) protocol/template sharing, (d) semi-automatic plan evaluation, (e) quality checklist for error prevention, (f) iterative process, (g) balance of speed and quality Learning Objectives: Gain familiarity with the workflow of modern treatment planning process. Understand the scope and challenges of managing modern treatment planning processes. Gain familiarity with Lean Six Sigma approaches and their implementation in the treatment planning workflow.

60 APPLIED LIFE SCIENCES↗

Quantum Key Distribution for Critical Infrastructures: Towards Cyber-Physical Security for Hydropower and Dams

Hydropower facilities are often remotely monitored or controlled from a centralized remote control room. Additionally, major component manufacturers monitor the performance of installed components, increasingly via public communication infrastructures. While these communications enable efficiencies and increased reliability, they also expand the cyber-attack surface. Communications may use the internet to remote control a facility’s control systems, or it may involve sending control commands over a network from a control room to a machine. The content could be encrypted and decrypted using a public key to protect the communicated information. These cryptographic encoding and decoding schemes become vulnerable as more advances are made in computer technologies, such as quantum computing. In contrast, quantum key distribution (QKD) and other quantum cryptographic protocols are not based upon a computational problem, and offer an alternative to symmetric cryptography in some scenarios. Although the underlying mechanism of quantum cryptogrpahic protocols such as QKD ensure that any attempt by an adversary to observe the quantum part of the protocol will result in a detectable signature as an increased error rate, potentially even preventing key generation, it serves as a warning for further investigation. In QKD, when the error rate is low enough and enough photons have been detected, a shared private key can be generated known only to the sender and receiver. We describe how this novel technology and its several modalities could benefit the critical infrastructures of dams or hydropower facilities. The presented discussions may be viewed as a precursor to a quantum cybersecurity roadmap for the identification of relevant threats and mitigation.

97 MATHEMATICS AND COMPUTING↗

The Reduction of Random Uncertainty in Differential Temperature Measurements Using Common Leg Thermocouples

The uncertainty quantification of random error is considered for common leg thermocouples (i.e., where one thermoelement is shared along the length of the TC for all other TC junctions present). The uncertainty is presented for both a common leg and individual, separate leg thermocouples. For Type K thermocouples a reduction in uncertainty by up to 3x is capable when differential temperatures, ?T, are within 150°C, and diminishes to little to no improvement above 150°C.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Determining the vulnerability of multi-threaded program code to soft errors

The described embodiments include a program code testing system that determines the vulnerability of multi-threaded program code to soft errors. For multi-threaded program code, two to more threads from the program code may access shared architectural structures while the program code is being executed. The program code testing system determines accesses of architectural structures made by the two or more threads of the multi-threaded program code and uses the determined accesses to determine a time for which the program code is exposed to soft errors. From this time, the program code testing system determines a vulnerability of the program code to soft errors.

97 MATHEMATICS AND COMPUTING↗

ISiCLE: A Quantum Chemistry Pipeline for Establishing in Silico Collision Cross Section Libraries

High throughput, comprehensive, and confident identifications of metabolites and other chemicals in biological and envi-ronmental samples will revolutionize our understanding of the role of these intriguing and chemically diverse molecules in biological systems. Despite recent technological advances, a metabolomics study still results in the detection of a dispropor-tionate number of features than cannot be confidently assigned to a chemical structure. This inadequacy is driven by the sin-gle most significant limitation in metabolomics: the reliance on reference libraries constructed through the analysis of au-thentic reference chemicals and the limited commercial availability of these compounds. To this end, we have developed the in silico chemical library engine (ISiCLE), a high-performance computing-friendly cheminformatics workflow for generating chemical properties. In the instantiation described here, we predict probable three-dimensional molecular conformers (i.e. conformational isomers) using chemical identifiers as input, from which collision cross sections (CCS) are derived. The ap-proach employs state-of-the-art first-principles simulation, distinguished by use of molecular dynamics, quantum chemistry, and ion mobility calculations to generate predictions, all without training data. Importantly, optimization of ISiCLE includ-ed a refactoring of the popular MOBCAL code for trajectory-based mobility calculations, improving its computational effi-ciency by over two orders of magnitude. Calculated CCS values were validated against 1,983 experimental CCS values and compared to previously reported CCS calculation approaches. Average CCS calculation absolute error is 3.2% with standard deviation 3.1%. An online database is introduced for sharing both calculated and experimental CCS values (metabolom-ics.pnnl.gov), initially including a CCS library with over 0.8M entries. Finally, three successful applications of molecule characterization using calculated CCS are described, including the identification of an environmental degradation product, the separation of molecular isomers, and the decoding of complex blinded mixtures of exposure chemicals. This work represents a promising method to address the limitations of small molecule identification, and offers alternatives to standards-based chemical identification amenable to high-performance computation.

metabolomics, standards-free, collision cross sect↗

Task-Based Neuromodulation Architecture for Lifelong Learning

The conventional supervised deep learning frameworks for image classification focus on finding the minimizer of an objective function. However, for a lifelong learning system, a network has to be able to dynamically learn new tasks from very few examples. In biological neural networks, it is observed that neuromodulation acts as a key factor in continual learning. In this work, we propose a dynamic learning system, ModNet, wherein a modulatory unit regulates the learning depending on the context and the internal state of the system. The modulatory unit, which consists of a group of neurons, exercises the use of neuromodulation and Hebbian plasticity mechanisms over a population of neurons instead of relying on backpropagation of error gradients. An efficient digital architecture with on-chip training and resource sharing is proposed to facilitate the efficacy of task-based processing.

brain-inspired↗

ISiCLE: A Quantum Chemistry Pipeline for Establishing in Silico Collision Cross Section Libraries

High throughput, comprehensive, and confident identifications of metabolites and other chemicals in biological and envi-ronmental samples will revolutionize our understanding of the role of these intriguing and chemically diverse molecules in biological systems. Despite recent technological advances, a metabolomics study still results in the detection of a dispropor-tionate number of features than cannot be confidently assigned to a chemical structure. This inadequacy is driven by the sin-gle most significant limitation in metabolomics: the reliance on reference libraries constructed through the analysis of au-thentic reference chemicals and the limited commercial availability of these compounds. To this end, we have developed the in silico chemical library engine (ISiCLE), a high-performance computing-friendly cheminformatics workflow for generating chemical properties. In the instantiation described here, we predict probable three-dimensional molecular conformers (i.e. conformational isomers) using chemical identifiers as input, from which collision cross sections (CCS) are derived. The ap-proach employs state-of-the-art first-principles simulation, distinguished by use of molecular dynamics, quantum chemistry, and ion mobility calculations to generate predictions, all without training data. Importantly, optimization of ISiCLE includ-ed a refactoring of the popular MOBCAL code for trajectory-based mobility calculations, improving its computational effi-ciency by over two orders of magnitude. Calculated CCS values were validated against 1,983 experimental CCS values and compared to previously reported CCS calculation approaches. Average CCS calculation absolute error is 3.2% with standard deviation 3.1%. An online database is introduced for sharing both calculated and experimental CCS values (metabolom-ics.pnnl.gov), initially including a CCS library with over 0.8M entries. Finally, three successful applications of molecule characterization using calculated CCS are described, including the identification of an environmental degradation product, the separation of molecular isomers, and the decoding of complex blinded mixtures of exposure chemicals. This work represents a promising method to address the limitations of small molecule identification, and offers alternatives to standards-based chemical identification amenable to high-performance computation.

Colby, Sean M↗