Search NASA⌕ Search

SEARCH · Search NASA

Results for “silicides”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

High Flux Isotope Reactor Low-Enriched Uranium High Density Silicide Fuel Preliminary Design Update: System Transient Analysis

As a part of conversion efforts from highly enriched uranium (HEU) to low-enriched uranium (LEU) fuel under direction of the National Nuclear Security Administration of the U.S. Department of Energy, multiple proposed designs of the High Flux Isotope Reactor (HFIR) have been created and assessed regarding reactor physics performance metrics, including designs utilizing uranium silicide dispersion fuel (U3Si2-Al). This report updates the previous analyses that evaluated the nuclear safety performance of LEU fuel designs with respect to selected accident events from the HFIR Safety Analysis Report (SAR). Both the Low Density (LD) and High Density (HD) Optimized designs’ reactivity initiated accident fuel performance improved relative to the HEU fuel, attributed to greater 238 U negative Doppler feedback. However, the thermal margins for primary coolant system accidents were reduced with some acceptance criteria unable to be met. The need to resolve reduced thermal margin, open modeling items, and unresolved assumptions was identified.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

HFIR LEU High Density Silicide Dispersion Optimized Design Neutronics Analyses with PHAME

A high-fidelity neutronics model of the Oak Ridge National Laboratory High Flux Isotope Reactor (HFIR) with the low-enriched uranium (LEU) high-density silicide dispersion Optimized fuel design was updated and analyzed to generate reactor physics-based metrics to support follow-on thermal hydraulic and transient analyses of this design. The Python HFIR Analysis and Measurement Engine (PHAME) was also updated to enhance the automation capabilities of the framework developed and maintained to perform these reactor physics modeling and simulation efforts. The automated framework significantly increases the efficiency and reproducibility to design and thoroughly analyzes HFIR LEU core designs, changes, and uncertainties. Reactor physics metrics evaluated include but are not limited to fuel depletion, cycle length, fission rate density distributions, axial power peaking factors, kinetics data, reactivity coefficients, control element worths, heat deposition rates, and decay heat. These neutronics results provide essential input to follow-on steady state thermal, thermal hydraulic and reactor transient analyses, which are subject of other reports. The Optimized design operates at 95 MW to maintain HFIR’s current highly enriched uranium core performance level at 85 MW.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Synthesis of Lanthanide-Based Intermetallic Silicides

Lanthanide-containing materials are of interest because of their useful magnetic and electronic behavior. To study this intrinsic behavior, researchers need high-quality single crystals to avoid interference from grain boundaries or defects commonly found in polycrystalline samples. One method for growing single crystals is metal-flux synthesis, an approach that promotes crystal growth at lower reaction temperatures thus providing access to complex intermetallic phases. My project focuses on synthesizing novel lanthanide-containing intermetallic silicides related to previously reported f-element compounds with the Gd1??Fe4Si10?? structure type. I investigated reactions targeting lanthanum, praseodymium, neodymium, samarium, europium, and gadolinium-containing products, and used scanning electron microscopy with energy-dispersive X-ray spectroscopy (SEM-EDS) to identify promising lanthanide-containing phases. I prepared reactions by loading lanthanide oxides, Co, Si, Al, and Ga into alumina crucibles in a 0.2:1:1:10:10 Ln2O3/Co/Si/Al/Ga mmol ratio, where Ln = La, Nd, Pr, Sm, Eu, or Gd. The reactions were sealed in quartz tubes, heated in a furnace, and centrifuged to separate crystals from excess flux. Afterwards, I mechanically isolated single crystals and prepared them for characterization. Pr-, Nd-, and Sm-containing reactions were confirmed through SEM-EDS to have formed the targeted quaternary phase. Single crystal X-ray diffraction (SC-XRD) data showed the Nd-containing crystals exhibited a hexagonal unit cell associated with the Gd1??Fe4Si10?? structure type. La- and Eu-containing reactions instead formed competing Co(Al/Ga/Si)3 phase crystals. Single-crystal XRD, powder XRD, and magnetic susceptibility and heat-capacity measurements will be collected for the remaining lanthanide-containing crystals. This data will help determine the complete crystal structure of the lanthanide analogues, their phase purity and whether they exhibit localized magnetic behavior, magnetic ordering, or other electronic signatures that can be compared with the previously reported actinide analogues. The disordered structure of this intermetallic family is associated with unusual magnetic and electronic behavior meaning lanthanide analogues may show potential as thermoelectric materials. Developing new thermoelectric candidate materials is relevant to energy efficiency and waste-heat recovery, which supports DOE’s broader goal of advancing science and technology solutions for America’s energy needs.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Oxidation/vaporization of silicide coated columbium base alloys

Mass spectrometric and target collection experiments were made at 1600 K to elucidate the mode of oxidative vaporization of two columbium alloys, fused-slurry-coated with a complex silicide former (Si-20Cr-Fe). At oxygen pressures up to 0.0005 torr the major vapor component detected by mass spectrometry for oxidized samples was gaseous silicon monoxide. Analysis of condensates collected at oxygen pressures of 0.1, 1.0 and 10 torr revealed that chromium-, silicon-, iron- and tungsten- containing species were the major products of vaporization. Equilibrium thermochemical diagrams were constructed for the metal-oxygen system corresponding to each constituent metal in both the coating and base alloy. The major vaporizing species are expected to be the gaseous oxides of chromium, silicon, iron and tungsten. Plots of vapor phase composition and maximum vaporization rate versus oxygen pressure were calculated for each coating constituent. The major contribution to weight loss by vaporization at oxygen pressures above 1 torr was shown to be the chromium-containing species.

Kohl, F. J.↗

Practical field repair of fused slurry silicide coating for space shuttle t.p.s.

Study of short-time high-temperature diffusion treatments as part of a program of development of methods of reapplying fused slurry silicide coating in the field. The metallographic structure and oxidation behavior of R512E applied to Cb-752 coated under simulated field repair conditions was determined. Oxidation testing in reduced pressure environment has shown that performance equivalent to furnace-processed specimens can be obtained in a two-minute diffusion at 2700 F.

Reznik, B. D.↗

Fusion silicide coatings for tantalum alloys.

Calculation of the performance of fusion silicide coatings under simulated atmospheric reentry conditions to a maximum temperature of 1810 K (2800 F). Both recently developed and commercially available coatings are included. Data are presented on oxidation rate with and without intentional defecting, the influence of the coatings on the ductile-brittle bend transition temperature, and the mechanical properties. Coatings appear capable of affording protection for at least 100 simulated cycles to 2600 F and 63 cycles to 2800 F.

Warnock, R. V.↗

Oxidation at through-hole defects in fused slurry silicide coated columbium alloys FS-85 and Cb-752

Metal recession and interstitial contamination at 0.08-centimeter-diameter through-hole intentional defects in fused slurry silicide coated FS-85 and Cb-752 columbium alloys were studied to determine the tolerance of these materials to coating defects. Five external pressure reentry simulation exposures to 1320 C and 4.7 x 1,000 N/sq m (maximum pressure) resulted in a consumed metal zone having about twice the initial defect diameter for both alloys with an interstitial contamination zone extending about three to four initial defect diameters. Self-healing occurred in the 1.33 x 10 N/sq m, 1320 C exposures and to a lesser extent in internal pressure reentry cycles to 1320 C and 1.33 x 100 N/sq m (maximum pressure).

Levine, S. R.↗

Modified fused silicide coatings for tantalum (Ta-10W) reentry heat shields

Results are presented of a program of research to develop a reliable, high performance, fused slurry silicide coating for the Ta-10W alloy. The effort was directed toward developing new and improved formulations for use at 2600 to 2800 F (1700 to 1811 K) in an atmospheric reentry thermal protection system with a 100-mission capability. Based on a thorough characterization of isothermal and cyclic oxidation behavior, bend transition temperatures, room- and elevated-temperature tensile properties, and creep behavior, a 2.5 Mn-33Ti-64.5Si coating (designated MTS) provides excellent protection for the Ta-10W alloy in simulated reentry environments. An extensive analysis of the oxidation behavior and characteristics of the MTS coating in terms of fundamental mechanisms also is presented.

Packer, C. M.↗

Fused slurry silicide coatings for columbium alloys reentry heat shields. Volume 1: Evaluation analysis

The R-512E (Si-20Cr-20Fe) fused slurry silicide coating process was optimized to coat full size (20in x 20in) single face rib and corrugation stiffened panels fabricated from FS-85 columbium alloy for 100 mission space shuttle heat shield applications. Structural life under simulated space shuttle lift-off stresses and reentry conditions demonstrated reuse capability well beyond 100 flights for R-512E coated FS-85 columbium heat shield panels. Demonstrated coating damage tolerance showed no immediate structural failure on exposure. The FS-85 columbium alloy was selected from five candidate alloys (Cb-752, C-129Y, WC-3015, B-66 and FS-85) based on the evaluation tests which have designed to determine: (1) change in material properties due to coating and reuse; (2) alloy tolerance to coating damage; (3) coating emittance characteristics under reuse conditions; and (4) new coating chemistries for improved coating life.

Fitzgerald, B.↗

Friction and wear of radiofrequency-sputtered borides, silicides, and carbides

The friction and wear properties of several refractory compound coatings were examined. These compounds were applied to 440 C bearing steel surfaces by radiofrequency (RF) sputtering. The refractory compounds were the titanium and molybdenum borides, the titanium and molybdenum silicides, and the titanium, molybdenum, and boron carbides. Friction testing was done with a pin-on-disk wear apparatus at loads from 0.1 to 5.0 newtons. Generally, the best wear properties were obtained when the coatings were bias sputtered onto 440 C disks that had been preoxidized. Adherence was improved because of the better bonding of the coatings to the iron oxide formed during preoxidation. As a class the carbides provided wear protection to the highest loads. Titanium boride coatings provided low friction and good wear properties to moderate loads.

Brainard, W. A.↗

An XPS study of the adherence of refractory carbide, silicide, and boride RF-sputtered wear-resistant coatings

Radio frequency sputtering was used to deposit refractory carbide, silicide, and boride coatings on 440-C steel substrates. Both sputter etched and pre-oxidized substrates were used and the films were deposited with and without a substrate bias. The composition of the coatings was determined as a function of depth by X-ray photoelectron spectroscopy combined with argon ion etching. Friction and wear tests were conducted to evaluate coating adherence. In the interfacial region there was evidence that bias may produce a graded interface for some compounds. Biasing, while generally improving bulk film stoichiometry, can adversely affect adherence by removing interfacial oxide layers. Oxides of all film constituents except carbon and iron were present in all cases but the iron oxide coverage was only complete on the preoxidized substrates. The film and iron oxides were mixed in the MoSi2 and Mo2C films but layered in the Mo2B5 films. In the case of mixed oxides, preoxidation enhanced film adherence. In the layered case it did not.

Brainard, W. A.↗

Ensuring the Consistency of Silicide Coatings

Diagram specifies optimum fusing time for given thicknesses of refractory metal-silicide coatings on columbium C-103 substrates. Adherence to indicated fusion times ensures consistent coatings and avoids underdiffusion and overdiffusion. Accuracy of diagram has been confirmed by tests.

Ramani, V.↗