Search NASA⌕ Search

SEARCH · Search NASA

Results for “slice sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

SU-E-T-144: Bayesian Inference of Local Relapse Data Using a Poisson-Based Tumour Control Probability Model

Purpose: The purpose of this project is to develop a robust method of parameter estimation for a Poisson-based TCP model using Bayesian inference. Methods: Bayesian inference was performed using the PyMC3 probabilistic programming framework written in Python. A Poisson-based TCP regression model that accounts for clonogen proliferation was fit to observed rates of local relapse as a function of equivalent dose in 2 Gy fractions for a population of 623 stage-I non-small-cell lung cancer patients. The Slice Markov Chain Monte Carlo sampling algorithm was used to sample the posterior distributions, and was initiated using the maximum of the posterior distributions found by optimization. The calculation of TCP with each sample step required integration over the free parameter α, which was performed using an adaptive 24-point Gauss-Legendre quadrature. Convergence was verified via inspection of the trace plot and posterior distribution for each of the fit parameters, as well as with comparisons of the most probable parameter values with their respective maximum likelihood estimates. Results: Posterior distributions for α, the standard deviation of α (σ), the average tumour cell-doubling time (Td), and the repopulation delay time (Tk), were generated assuming α/β = 10 Gy, and a fixed clonogen density of 10{sup 7} cm−{sup 3}. Posterior predictive plots generated from samples from these posterior distributions are in excellent agreement with the observed rates of local relapse used in the Bayesian inference. The most probable values of the model parameters also agree well with maximum likelihood estimates. Conclusion: A robust method of performing Bayesian inference of TCP data using a complex TCP model has been established.

60 APPLIED LIFE SCIENCES↗

Effects on image quality of a 2D antiscatter grid in x-ray digital breast tomosynthesis: Initial experience using the dual modality (x-ray and molecular) breast tomosynthesis scanner

Purpose: Radiation scattered from the breast in digital breast tomosynthesis (DBT) causes image degradation, including loss of contrast between cancerous and background tissue. Unlike in 2-dimensional (2D) mammography, an antiscatter grid cannot readily be used in DBT because changing alignment between the tube and detector during the scan would result in unacceptable loss of primary radiation. However, in the dual modality breast tomosynthesis (DMT) scanner, which combines DBT and molecular breast tomosynthesis, the tube and detector rotate around a common axis, thereby maintaining a fixed tube-detector alignment. This C-arm geometry raises the possibility of using a 2D (cellular) focused antiscatter grid. The purpose of this study is to assess change in image quality when using an antiscatter grid in the DBT portion of a DMT scan under conditions of fixed radiation dose. Methods: Two 2D focused prototype grids with 80 cm focal length were tested, one stack-laminated from copper (Cu) and one cast from a tungsten-polymer (W-poly). They were reciprocated using a motion scheme designed to maximize transmission of primary x-ray photons. Grid-in and grid-out scatter-to-primary ratios (SPRs) were measured for rectangular blocks of material simulating 30%, 50%, and 70% glandular tissue compositions. For assessment of changes in image quality through the addition of a grid, the Computerized Imaging Reference Systems, Inc., phantom Model 011A containing a set of 1 cm thick blocks simulating a range of glandular/adipose ratios from 0/100 to 100/0 was used. To simulate 6.5 and 8.5 cm thick compressed breasts, 1 cm thick slices of PMMA were added to the Model 011A phantom. DBT images were obtained with and without the grid, with exposure parameters fixed for a given compressed thickness. Signal-difference-to-noise ratios (SDNRs), contrast, and voxel value-based attenuation coefficients (μ) were measured for all blocks from reconstructed phantom images. Results: For 4, 6, and 8 cm tissue-equivalent block phantom thicknesses, the inclusion of the W-poly grid reduced the SPR by factors of 5, 6, and 5.8, respectively. For the same thicknesses, the copper grid reduced the SPR by factors of 3.9, 4.5, and 4.9. For the 011A phantom, the W-poly grid raised the SDNR of the 70/30 block from 0.8, −0.32, and −0.72 to 0.9, 0.76, and 0.062 for the 4.5, 6.5, and 8.5 cm phantoms, respectively. It raised the SDNR of the 100/0 block from 3.78, 1.95, and 1.0 to 3.79, 3.67, and 3.25 for the 4.5, 6.5, and 8.5 cm phantoms, respectively. Inclusion of the W-poly grid improved the accuracy of image-based μ values for all block compositions. However, smearing of attenuation across slices due to limited angular sampling decreases the sensitivity of voxel values to changing composition compared to theoretical μ values. Conclusions: Under conditions of fixed radiation dose to the breast, use of a 2D focused grid increased contrast, SDNR, and accuracy of estimated attenuation for mass-simulating block compositions in all phantom thicknesses tested, with the degree of improvement depending upon material composition. A 2D antiscatter grid can be usefully incorporated in DBT systems that employ fully isocentric tube-detector rotation.

60 APPLIED LIFE SCIENCES↗

Core Characterization of Bakken Shale from the Bedwell 33-52-1-1H Well, Sheridan County, Montana

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core of the Bedwell 33-52-1-1H well (API 25-091-21920), a wildcat field in Sheridan County, Montana. The primary impetus of this work is to provide a unique dataset to researchers at universities, national laboratories, geological surveys, and other locations for additional analyses. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/bedwell-33-52-1-1h-well. The equipment and techniques used to characterize the full core were non-destructive, enabling future examinations and analyses to be performed on these cores. However, none of the equipment used was suitable for direct visualization of the pore space in fine-grained structures such as those found in shales; fractures, discontinuities, and millimeter scale features were readily detectable with the methods tested. Imaging with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis. A selection of samples (Table 1) were cored, sliced, and powdered for additional characterization analyses. These analyses did involve destructive subsampling of the full core at discrete sections, and the results are presented here in the context of the larger core description. Selected sections of the core were removed from the full core for detailed analyses using the following destructive techniques: bulk inductively coupled plasma-optical emission spectroscopy (ICP-OES), isolation of carbon and sulfur, Fourier transform infrared (FTIR) spectroscopy, scanning electron microscopy (SEM), and higher resolution CT scan with NETL’s micro-CT scanning systems. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

04 OIL SHALES AND TAR SANDS↗

Focused‐beam X‐ray fluorescence and diffraction microtomographies for mineralogical and chemical characterization of unsectioned extraterrestrial samples

Abstract This study describes the application of new synchrotron X‐ray fluorescence (XRF) and diffraction (XRD) microtomographies for the 3‐D visualization of chemical and mineralogical variations in unsectioned extraterrestrial samples. These improved methods have been applied to three compositionally diverse chondritic meteorite samples that were between 300 and 400 μm in diameter, including samples prepared from fragments of the CR2 chondrite LaPaz Icefield (LAP) 02342, H5 chondrite MacAlpine Hills (MAC) 88203, and the CM2 chondrite Murchison. The synchrotron‐based XRF and XRD tomographies used are focused‐beam techniques that measure the intensities of fluorescent and diffracted X‐rays in a sample simultaneously during irradiation by a high‐energy microfocused incident X‐ray beam. Measured sinograms of the emitted and diffracted intensities were then tomographically reconstructed to generate 2‐D slices of XRF and XRD intensity through the sample, with reconstructed pixel resolution of 1–2 μm, defined by the resolution of the focused incident X‐ray beam. For sample LAP 02342, primary mineral phases that were visualized in reconstructed slices using these techniques included isolated grains of α‐Fe, orthopyroxene, and olivine. For our sample of MAC 88203, XRF/XRD tomography allowed visualization of forsteritic olivine as a primary mineral phase, a vitrified fusion crust at the sample surface, identification of localized Cr‐rich spinels at spatial resolutions of several micrometers, and imaging of a plagioclase‐rich glassy matrix. In the sample of Murchison, major identifiable phases include clinoenstatite‐ and olivine‐rich chondrules, variable serpentine matrix minerals and small Cr‐rich spinels. Most notable in the tomographic analysis of Murchison is the ability to quantitatively distinguish and visualize the complex mixture of serpentine‐group minerals and associated tochilinite–cronstedtite intergrowths. These methods provide new opportunities for spatially resolved characterization of sample texture, mineralogy, crystal structure, and chemical state in unsectioned samples. This provides researchers an ability to characterize such samples internally with minimal disruption of sample micro‐structures and chemistry, possibly without the need for sample extraction from some types of sampling and capture media.

Geochemistry & Geophysics↗

Deformation mechanisms, defects, heat treatment, and thermal conductivity in large grain niobium

The physical and mechanical metallurgy underlying fabrication of large grain cavities for superconducting radio frequency accelerators is summarized, based on research of 1) grain orientations in ingots, 2) a metallurgical assessment of processing a large grain single cell cavity and a tube, 3) assessment of slip behavior of single crystal tensile samples extracted from a high purity ingot slice before and after annealing at 800 °C / 2 h, 4) development of crystal plasticity models based upon the single crystal experiments, and 5) assessment of how thermal conductivity is affected by strain, heat treatment, and exposure to hydrogen. Because of the large grains, the plastic anisotropy of deformation is exaggerated, and heterogeneous strains and localized defects are present to a much greater degree than expected in polycrystalline material, making it highly desirable to computationally anticipate potential forming problems before manufacturing cavities.

36 MATERIALS SCIENCE↗

X-ray nanotomography and focused-ion-beam sectioning for quantitative three-dimensional analysis of nanocomposites

Knowing the relationship between three-dimensional structure and properties is paramount for complete understanding of material behavior. In this work, the internal nanostructure of micrometer-size (~10 µm) composite Ni/Al particles was analyzed using two different approaches. The first technique, synchrotron-based X-ray nanotomography, is a nondestructive method that can attain resolutions of tens of nanometers. The second is a destructive technique with sub-nanometer resolution utilizing scanning electron microscopy combined with an ion beam and `slice and view' analysis, where the sample is repeatedly milled and imaged. The obtained results suggest that both techniques allow for an accurate characterization of the larger-scale structures, while differences exist in the characterization of the smallest features. Using the Monte Carlo method, the effective resolution of the X-ray nanotomography technique was determined to be ~48 nm, while focused-ion-beam sectioning with `slice and view' analysis was ~5 nm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Formation mechanisms of precursors of radiation-induced color centers during fabrication of silica optical fiber preform

Samples in the form of transverse slices of rods and optical fiber preforms made from the high-hydroxyl KU-1 and low-hydroxyl KS-4V silica by the plasma outside deposition (POD) method are {gamma}-irradiated to a dose of {approx}1 MGy (SiO{sub 2}). Next, the radial dependences of the radiation-induced nonbridging oxygen hole center (NBOHC) and E'-center (three-coordinated silicon) in the samples are constructed by measuring the amplitudes of their 4.8 and 5.8 eV absorption bands, respectively. Based on the analysis of these radial dependences and considering the temperature and duration of the preirradiation heat treatment of the rods and preforms at the POD-installation, we determine the ratio of the oscillator strengths of the above bands and the microscopic thermoinduced processes occurring during preform fabrication and producing precursors of the radiation-induced NBOHC and E'-center. These processes are found to be associated with the escape of either H{sub 2} or H{sub 2}O from neighboring hydroxyl groups, and, therefore, can occur in high-hydroxyl silica only. It is concluded that enhancement of the radiation resistance of high-hydroxyl silica optical fibers requires decreasing the temperature and duration of the preform fabrication process, in particular, changing from the POD-technology to the low-temperature plasmachemical vapor deposition (PCVD) or surface PCVD (SPCVD)-technology.

36 MATERIALS SCIENCE↗

Subaru Hyper Suprime-Cam revisits the large-scale environmental dependence on galaxy morphology over 360 deg2 at z = 0.3–0.6

This study investigates the role of large-scale environments on the fraction of spiral galaxies at z = 0.3–0.6 sliced to three redshift bins of Δz = 0.1. Here, we sample 276220 massive galaxies in a limited stellar mass of 5 × 1010 solar mass (~M*) over 360 deg2, as obtained from the Second Public Data Release of the Hyper Suprime-Cam Subaru Strategic Program (HSC-SSP). By combining projected two-dimensional density information (Shimakawa et al. 2021, MNRAS, 503, 3896) and the CAMIRA cluster catalog (Oguri et al. 2018, PASJ, 70, S20), we investigate the spiral fraction across large-scale overdensities and in the vicinity of red sequence clusters. We adopt transfer learning to reduce the cost of labeling spiral galaxies significantly and then perform stacking analysis across the entire field to overcome the limitations of sample size. Here we employ a morphological classification catalog by the Galaxy Zoo Hubble (Willett et al., 2017, MNRAS, 464, 4176) to train the deep learning model. Based on 74103 sources classified as spirals, we find moderate morphology–density relations on a 10 comoving Mpc scale, thanks to the wide-field coverage of HSC-SSP. Clear deficits of spiral galaxies have also been confirmed, in and around 1136 red sequence clusters. Furthermore, we verify whether there is a large-scale environmental dependence on rest-frame u - r colors of spiral galaxies; such a tendency was not observed in our sample.

Astronomy & Astrophysics↗

Feature Extraction and Selection From the Perspective of Explosive Detection

Features are extractable measurements from a sample image summarizing the information content in an image and in the process providing an essential tool in image understanding. In particular, they are useful for image classification into pre-defined classes or grouping a set of image samples (also called clustering) into clusters with similar within-cluster characteristics as defined by such features. At the lowest level, features may be the intensity levels of a pixel in an image. The intensity levels of the pixels in an image may be derived from a variety of sources. For example, it can be the temperature measurement (using an infra-red camera) of the area representing the pixel or the X-ray attenuation in a given volume element of a 3-d image or it may even represent the dielectric differential in a given volume element obtained from an MIR image. At a higher level, geometric descriptors of objects of interest in a scene may also be considered as features in the image. Examples of such features are: area, perimeter, aspect ratio and other shape features, or topological features like the number of connected components, the Euler number (the number of connected components less the number of 'holes'), etc. Occupying an intermediate level in the feature hierarchy are texture features which are typically derived from a group of pixels often in a suitably defined neighborhood of a pixel. These texture features are useful not only in classification but also in the segmentation of an image into different objects/regions of interest. At the present state of our investigation, we are engaged in the task of finding a set of features associated with an object under inspection ( typically a piece of luggage or a brief case) that will enable us to detect and characterize an explosive inside, when present. Our tool of inspection is an X-Ray device with provisions for computed tomography (CT) that generate one or more (depending on the number of energy levels used) digitized 3-dimensional attenuation images with a voxel resolution of the order of one quarter of a milimeter. In the task of feature extraction and subsequent selection of an appropriate subset thereof, several important factors need to be considered. Foremost among them are: (1) Definition of the sampling unit from which the features will be extracted for the purpose of detection/ identification of the explosives. (2) The choice of features ( given the sampling unit) to be extracted that can be used to signal the existence / identity of the explosive. (3) Robustness of the computed features under different inspection conditions. To attain robustness, invariance under the transformations of translation, scaling, rotation and change of orientation is highly desirable. (4) The computational costs in the process of feature extraction, selection and their use in explosive detection/ identification In the search for extractable features, we have done a thorough literature survey with the above factors in mind and come out with a list of features that could possibly help us in meeting our objective. We are assuming that features will be based on sampling units that are single CT slices of the target. This may however change when appropriate modifications should be made to the feature extraction process. We indicate below some of the major types of features in 2- or 3-dimensional images that have been used in the literature on application of pattern recognition (PR) techniques in image understanding and are possibly pertinent to our study. In the following paragraph, we briefly indicate the motivation that guided us in the choice of these features, and identify the nature of the constraints. The principal feature types derivable from an image will be discussed in section 2. Once the features are extracted, one must select a subset of this feature set that will retain the most useful information and remove any redundant and irrelevant information that may have a detrimental effect on the classifier performance. This is discussed in section 3. Section 4 provides a brief summary.

42 ENGINEERING↗

New generation bunch shape monitor for ion accelerators

Measuring longitudinal beam parameters is important for operation and development of high intensity linear accelerators, but it is notoriously difficult for proton and ion beams at non-relativistic energies. The Bunch Shape Monitor (BSM) is a device used for measuring the longitudinal bunch distribution in ion linacs. The existing BSM models have poor electron collection efficiency from the wire and are limited to one-dimensional measurements of the phase coordinate. In response to this problem, we have developed a new generation BSM with improved performance. The proposed design incorporates three major innovations: First, the collection efficiency was improved by adding a focusing field between the wire and the entrance slit, which will also allow measurements over a much wider dynamic range. Second, an improvement in the measurement speed was achieved by sampling longitudinal profiles of multiple energy slices simultaneously, where the BSM wire is placed at the exit of an ion spectrometer so that ions with different energies hit the wire at different horizontal coordinates along the wire. Finally, the design incorporates a motion system that can shift the wire and deflecting cavity together, enabling transverse profile measurements like a wire scanner. Here, in this paper, we will provide the design of the new BSM and report on its beam test results at the Spallation Neutron Source facility in Oak Ridge National Laboratory.

43 PARTICLE ACCELERATORS↗

Measurement of a cosmographic distance ratio with galaxy and cosmic microwave background lensing

We measure the gravitational lensing shear signal around dark matter halos hosting constant mass galaxies using light sources at z~1 (background galaxies) and at the surface of last scattering at z~1100 (the cosmic microwave background). The galaxy shear measurement uses data from the CFHTLenS survey, and the microwave background shear measurement uses data from the Planck satellite. The ratio of shears from these cross-correlations provides a purely geometric distance measurement across the longest possible cosmological lever arm. This is because the matter distribution around the halos, including uncertainties in galaxy bias and systematic errors such as miscentering, cancels in the ratio for halos in thin redshift slices. We measure this distance ratio in three different redshift slices of the constant mass (CMASS) sample and combine them to obtain a 17% measurement of the distance ratio, r = 0.390 +0.070 –0.062 , at an effective redshift of z = 0.53. As a result, this is consistent with the predicted ratio from the Planck best-fit cold dark matter model with a cosmological constant cosmology of r = 0.419.

79 ASTRONOMY AND ASTROPHYSICS↗

Detecting Distance between Injected Microspheres and Target Tumor via 3D Reconstruction of Tissue Sections

One treatment increasing in use for solid tumors in the liver is radioembolization via the delivery of 90Y microspheres to the vascular bed within or near the location of the tumor. It is desirable as part of the treatment for the microspheres to embed preferentially in or near the tumor. This work details an approach for analyzing the deposition of microspheres with respect to the location of the tumor. The approach used is based upon thin-slice serial sectioning of the tissue sample, followed by high resolution imaging, microsphere detection, and 3-D reconstruction of the tumor surface. Distance from the microspheres to the tumor was calculated using a fast deterministic point inclusion method.

Carson, James P.↗

Whole-Cell Analysis of Low-Density Lipoprotein Uptake by Macrophages Using STEM Tomography

Nanoparticles of heavy materials such as gold can be used as markers in quantitative electron microscopic studies of protein distributions in cells with nanometer spatial resolution. Studying nanoparticles within the context of cells is also relevant for nanotoxicological research. Here, we report a method to quantify the locations and the number of nanoparticles, and of clusters of nanoparticles inside whole eukaryotic cells in three dimensions using scanning transmission electron microscopy (STEM) tomography. Whole-mount fixed cellular samples were prepared, avoiding sectioning or slicing. The level of membrane staining was kept much lower than is common practice in transmission electron microscopy (TEM), such that the nanoparticles could be detected throughout the entire cellular thickness. Tilt-series were recorded with a limited tilt-range of 80° thereby preventing excessive beam broadening occurring at higher tilt angles. The 3D locations of the nanoparticles were nevertheless determined with high precision using computation. The obtained information differed from that obtained with conventional TEM tomography data since the nanoparticles were highlighted while only faint contrast was obtained on the cellular material. Similar as in fluorescence microscopy, a particular set of labels can be studied. This method was applied to study the fate of sequentially up-taken low-density lipoprotein (LDL) conjugated to gold nanoparticles in macrophages. Analysis of a 3D reconstruction revealed that newly up-taken LDL-gold was delivered to lysosomes containing previously up-taken LDL-gold thereby forming onion-like clusters.

59 BASIC BIOLOGICAL SCIENCES↗

Wasserstein Normalized Autoencoder for Anomaly Detection in ProtoDUNE Vertical-Drift Detector

ProtoDUNE Vertical Drift needs a selective triggering algorithm. The detector sits on Earth's surface, so cosmic activity dominates its data. Our goal in this paper is to trigger on neutrino events more robustly than the current deployed Analog-to-Digital Converter Simple Window (ADCSW) model and, eventually, search for signals of Beyond Standard Model (BSM) physics at DUNE as our ultimate North Star objective. As a step towards this goal, we evaluate a Wasserstein Normalized Autoencoder (WNAE) on simulated collection-plane only windows of shape $1\times10\times10$ where Neutrinos act as our BSM-proxy and Cosmic-ray Muons serve as our learned background. The network parameters are fitted using only cosmic-ray muon events as background in order to maintain an unsupervised pipeline. Training uses finite-step Langevin $x^-$ samples, positive-sample reconstruction energy, and an empirical sliced $2$-Wasserstein objective to learn a normalized Boltzmann energy model. We then calibrate on a nominal $5\,\mathrm{Hz}$ operating threshold calculated from cosmic validation data. Both WNAE and ADCSW accept 311 of 194,083 held-out cosmic background events at this $5\,\mathrm{Hz}$ threshold. We found that WNAE accepts 9,677 of 34,634 neutrino-proxy events $(27.9\pm0.24)\%$, compared with 10,076 $(29.1\pm0.24)\%$ for ADCSW, an observed WNAE-minus-ADCSW difference of $-1.15\%$. At another nominal $2\,\mathrm{Hz}$ target threshold, the corresponding efficiencies are $(20.5\pm0.22)\%$ and $(22.6\pm0.22)\%$, respectively. Of the WNAE-selected neutrino proxies at $5\,\mathrm{Hz}$, $(20.8\pm0.4)\%$ of the classified neutrino-proxy events are unique to WNAE, where the uncertainty is an absolute binomial standard error of $0.4\%$.

Zheng, Jake [U. Chicago (main)] (ORCID:00090002189↗

Wasserstein Normalized Autoencoder for Anomaly Detection in ProtoDUNE Vertical-Drift Detector

ProtoDUNE Vertical Drift needs a selective triggering algorithm. The detector sits on Earth's surface, so cosmic activity dominates its data. Our goal in this paper is to trigger on neutrino events more robustly than the current deployed Analog-to-Digital Converter Simple Window (ADCSW) model and, eventually, search for signals of Beyond Standard Model (BSM) physics at DUNE as our ultimate North Star objective. As a step towards this goal, we evaluate a Wasserstein Normalized Autoencoder (WNAE) on simulated collection-plane only windows of shape $1\times10\times10$ where Neutrinos act as our BSM-proxy and Cosmic-ray Muons serve as our learned background. The network parameters are fitted using only cosmic-ray muon events as background in order to maintain an unsupervised pipeline. Training uses finite-step Langevin $x^-$ samples, positive-sample reconstruction energy, and an empirical sliced $2$-Wasserstein objective to learn a normalized Boltzmann energy model. We then calibrate on a nominal $5\,\mathrm{Hz}$ operating threshold calculated from cosmic validation data. Both WNAE and ADCSW accept 311 of 194,083 held-out cosmic background events at this $5\,\mathrm{Hz}$ threshold. We found that WNAE accepts 9,677 of 34,634 neutrino-proxy events $(27.9\pm0.24)\%$, compared with 10,076 $(29.1\pm0.24)\%$ for ADCSW, an observed WNAE-minus-ADCSW difference of $-1.15\%$. At another nominal $2\,\mathrm{Hz}$ target threshold, the corresponding efficiencies are $(20.5\pm0.22)\%$ and $(22.6\pm0.22)\%$, respectively. Of the WNAE-selected neutrino proxies at $5\,\mathrm{Hz}$, $(20.8\pm0.4)\%$ of the classified neutrino-proxy events are unique to WNAE, where the uncertainty is an absolute binomial standard error of $0.4\%$.

Zheng, Jake [Chicago U.] (ORCID:0009000218901379)↗

Direct observation of dislocation structure evolution in SRF cavity niobium using electron channeling contrast imaging

Two major goals of superconducting radio frequency cavity research and development are achieving higher accelerating gradient and gaining the highest quality factor, a measure of efficiency. However, the consistent improvement of these performance metrics is restricted by many factors, one of which is microstructural defects, such as dislocation substructures within the material. In this work, dislocation evolution is compared in four samples extracted from a 2.8 mm thick large-grain niobium slice, with tensile axes chosen to generate specific dislocation structures during subsequent deformation. The four samples are (1) as-extracted, (2) extracted and annealed, (3) extracted and then deformed to 40% tensile strain, and (4) extracted, annealed at 800 °C 2 h, and then deformed to 40% strain. Electron channeling contrast imaging was performed on all samples to characterize initial dislocation density and dislocation structure evolution due to annealing and deformation, and related to the mechanical behavior observed in stress-strain curves. A fundamental understanding of dislocation evolution in niobium is necessary to develop computational models to simulate cavity forming, which could enable new processing methods for cavity fabrication to be identified that could lead to improved performance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Utility of spatially-resolved atmospheric pressure surface sampling and ionization techniques as alternatives to mass spectrometric imaging (MSI) in drug metabolism

1. Tissue distribution studies of drug molecules play an essential role in the pharmaceutical industry and are commonly undertaken using quantitative whole body autoradiography (QWBA) methods. 2. The growing need for complementary methods to address some scientific gaps around radiography methods has led to increased use of mass spectrometric imaging (MSI) technology over the last 5 to 10 years. More recently, the development of novel mass spectrometric techniques for ambient surface sampling has redefined what can be regarded as fit-for-purpose for MSI in a drug metabolism and disposition arena. 3. Together with a review of these novel alternatives, this paper details the use of two liquid microjunction (LMJ)- based mass spectrometric surface sampling technologies. These approaches are used to provide qualitative determination of parent drug in rat liver tissue slices using liquid extraction surface analysis (LESA) and to assess the performance of a LMJ surface sampling probe (LMJ-SSP) interface for quantitative assessment of parent drug in brain, liver and muscle tissue slices. 4. An assessment of the utility of these spatially-resolved sampling methods is given, showing interdependence between mass spectrometric and QWBA methods, in particular there emerges a reason to question typical MSI workflows for drug metabolism; suggesting the expedient use of profile or region analysis may be more appropriate, rather than generating time-intensive molecular images of the entire tissue section.

ambient surface sampling↗

Characterization of the VVV Survey RR Lyrae Population across the Southern Galactic Plane

Deep near-IR images from the VISTA Variables in the Vía Láctea (VVV) Survey were used to search for RR Lyrae stars in the Southern Galactic plane. A sizable sample of 404 RR Lyrae of type ab stars was identified across a thin slice of the fourth Galactic quadrant (295° < ℓ < 350°, −2.°24 < b < −1.°05). The sample’s distance distribution exhibits a maximum density that occurs at the bulge tangent point, which implies that this primarily Oosterhoff type I population of RRab stars does not trace the bar delineated by their red clump counterparts. The bulge RR Lyrae population does not extend beyond ℓ ∼ 340°, and the sample’s spatial distribution presents evidence of density enhancements and substructure that warrants further investigation. Indeed, the sample may be employed to evaluate Galactic evolution models, and is particularly lucrative since half of the discovered RR Lyrae are within reach of Gaia astrometric observations.

79 ASTRONOMY AND ASTROPHYSICS↗