Laboratory simulations of large scale fragmentation events

Results are presented from fragmentation experiments at elevated external pressure; the application of overpressure to a small target allows the experiment to match the lithospheric compressive stress of a larger body's interior. With increasing overpressure, the fragmentation undergoes a transition, from a material strength-dominated regime to one that is dominated by applied overpressure, analogous to the transition from strength to gravity effects. High pressure testing allows direct measurement of the energy/unit target mass requirement of catastrophic fragmentation due to compressive stresses.

Housen, Kevin R.↗

Determination of design and operation parameters for upper atmospheric research instrumentation to yield optimum resolution with deconvolution, appendix 2

This thesis reviews the technique established to clear channels in the Power Spectral Estimate by applying linear combinations of well known window functions to the autocorrelation function. The need for windowing the auto correlation function is due to the fact that the true auto correlation is not generally used to obtain the Power Spectral Estimate. When applied, the windows serve to reduce the effect that modifies the auto correlation by truncating the data and possibly the autocorrelation has on the Power Spectral Estimate. It has been shown in previous work that a single channel has been cleared, allowing for the detection of a small peak in the presence of a large peak in the Power Spectral Estimate. The utility of this method is dependent on the robustness of it on different input situations. We extend the analysis in this paper, to include clearing up to three channels. We examine the relative positions of the spikes to each other and also the effect of taking different percentages of lags of the auto correlation in the Power Spectral Estimate. This method could have application wherever the Power Spectrum is used. An example of this is beam forming for source location, where a small target can be located next to a large target. Other possibilities extend into seismic data processing. As the method becomes more automated other applications may present themselves.

Ioup, George E.↗

Overcoming Dynamic Disturbances in Imaging Systems

We develop and discuss a methodology with the potential to yield a significant reduction in complexity, cost, and risk of space-borne optical systems in the presence of dynamic disturbances. More robust systems almost certainly will be a result as well. Many future space-based and ground-based optical systems will employ optical control systems to enhance imaging performance. The goal of the optical control subsystem is to determine the wavefront aberrations and remove them. Ideally reducing an aberrated image of the object under investigation to a sufficiently clear (usually diffraction-limited) image. Control will likely be distributed over several elements. These elements may include telescope primary segments, telescope secondary, telescope tertiary, deformable mirror(s), fine steering mirror(s), etc. The last two elements, in particular, may have to provide dynamic control. These control subsystems may become elaborate indeed. But robust system performance will require evaluation of the image quality over a substantial range and in a dynamic environment. Candidate systems for improvement in the Earth Sciences Enterprise could include next generation Landsat systems or atmospheric sensors for dynamic imaging of individual, severe storms. The technology developed here could have a substantial impact on the development of new systems in the Space Science Enterprise; such as the Next Generation Space Telescope(NGST) and its follow-on the Next NGST. Large Interferometric Systems of non-zero field, such as Planet Finder and Submillimeter Probe of the Evolution of Cosmic Structure, could benefit. These systems most likely will contain large, flexible optomechanical structures subject to dynamic disturbance. Furthermore, large systems for high resolution imaging of planets or the sun from space may also benefit. Tactical and Strategic Defense systems will need to image very small targets as well and could benefit from the technology developed here. We discuss a novel speckle imaging technique with the potential to separate dynamic aberrations from static aberrations. Post-processing of a set of image data, using an algorithm based on this technique, should work for all but the lowest light levels and highest frequency dynamic environments. This technique may serve to reduce the complexity of the control system and provide for robust, fault-tolerant, reduced risk operation. For a given object, a short exposure image is "frozen" on the focal plane in the presence of the environmental disturbance (turbulence, jitter, etc.). A key factor is that this imaging data exhibits frame-to-frame linear shift invariance. Therefore, although the Point Spread Function is varying from frame to frame, the source is fixed; and each short exposure contains object spectrum data out to the diffraction limit of the imaging system. This novel speckle imaging technique uses the Knox-Thompson method. The magnitude of the complex object spectrum is straightforward to determine by well-established approaches. The phase of the complex object spectrum is decomposed into two parts. One is a single-valued function determined by the divergence of the optical phase gradient. The other is a multi-valued function determined by the circulation of the optical phase gradient-"hidden phase." Finite difference equations are developed for the phase. The novelty of this approach is captured in the inclusion of this "hidden phase." This technique allows the diffraction-limited reconstruction of the object from the ensemble of short exposure frames while simultaneously estimating the phase as a function of time from a set of exposures.

Young, Eric W.↗

Overcoming Dynamic Disturbances in Imaging Systems

We develop and discuss a methodology with the potential to yield a significant reduction in complexity, cost, and risk of space-borne optical systems in the presence of dynamic disturbances. More robust systems almost certainly will be a result as well. Many future space-based and ground-based optical systems will employ optical control systems to enhance imaging performance. The goal of the optical control subsystem is to determine the wavefront aberrations and remove them. Ideally reducing an aberrated image of the object under investigation to a sufficiently clear (usually diffraction-limited) image. Control will likely be distributed over several elements. These elements may include telescope primary segments, telescope secondary, telescope tertiary, deformable mirror(s), fine steering mirror(s), etc. The last two elements, in particular, may have to provide dynamic control. These control subsystems may become elaborate indeed. But robust system performance will require evaluation of the image quality over a substantial range and in a dynamic environment. Candidate systems for improvement in the Earth Sciences Enterprise could include next generation Landsat systems or atmospheric sensors for dynamic imaging of individual, severe storms. The technology developed here could have a substantial impact on the development of new systems in the Space Science Enterprise; such as the Next Generation Space Telescope(NGST) and its follow-on the Next NGST. Large Interferometric Systems of non-zero field, such as Planet Finder and Submillimeter Probe of the Evolution of Cosmic Structure, could benefit. These systems most likely will contain large, flexible optormechanical structures subject to dynamic disturbance. Furthermore, large systems for high resolution imaging of planets or the sun from space may also benefit. Tactical and Strategic Defense systems will need to image very small targets as well and could benefit from the technology developed here. We discuss a novel speckle imaging technique with the potential to separate dynamic aberrations from static aberrations. Post-processing of a set of image data, using an algorithm based on this technique, should work for all but the lowest light levels and highest frequency dynamic environments. This technique may serve to reduce the complexity of the control system and provide for robust, fault-tolerant, reduced risk operation. For a given object, a short exposure image is "frozen" on the focal plane in the presence of the environmental disturbance (turbulence, jitter, etc.). A key factor is that this imaging data exhibits frame-to-frame linear shift invariance. Therefore, although the Point Spread Function is varying from frame to frame, the source is fixed; and each short exposure contains object spectrum data out to the diffraction limit of the imaging system. This novel speckle imaging technique uses the Knox-Thompson method. The magnitude of the complex object spectrum is straightforward to determine by well-established approaches. The phase of the complex object spectrum is decomposed into two parts. One is a single-valued function determined by the divergence of the optical phase gradient. The other is a multi-valued function determined by, the circulation of the optical phase gradient-"hidden phase." Finite difference equations are developed for the phase. The novelty of this approach is captured in the inclusion of this "hidden phase." This technique allows the diffraction-limited reconstruction of the object from the ensemble of short exposure frames while simultaneously estimating the phase as a function of time from a set of exposures.

Young, Eric W.↗

Xenon Sputter Yield Measurements for Ion Thruster Materials

In this paper, we describe a technique that was used to measure total and differential sputter yields of materials important to high specific impulse ion thrusters. The heart of the technique is a quartz crystal monitor that is swept at constant radial distance from a small target region where a high current density xenon ion beam is aimed. Differential sputtering yields were generally measured over a full 180 deg arc in a plane that included the beam centerline and the normal vector to the target surface. Sputter yield results are presented for a xenon ion energy range from 0.5 to 10 keV and an angle of incidence range from 0 deg to 70 deg from the target surface normal direction for targets consisting of molybdenum, titanium, solid (Poco) graphite, and flexible graphite (grafoil). Total sputter yields are calculated using a simple integration procedure and comparisons are made to sputter yields obtained from the literature. In general, the agreement between the available data is good. As expected for heavy xenon ions, the differential and total sputter yields are found to be strong functions of angle of incidence. Significant under- and over-cosine behavior is observed at low- and high-ion energies, respectively. In addition, strong differences in differential yield behavior are observed between low-Z targets (C and Ti) and high-Z targets (Mo). Curve fits to the differential sputter yield data are provided. They should prove useful to analysts interested in predicting the erosion profiles of ion thruster components and determining where the erosion products re-deposit.

Williams, John D.↗

Differential Sputtering Behavior of Pyrolytic Graphite and Carbon-Carbon Composite Under Xenon Bombardment

A differential sputter yield measurement technique is described, which consists of a quartz crystal monitor that is swept at constant radial distance from a small target region where a high current density xenon ion beam is aimed. This apparatus has been used to characterize the sputtering behavior of various forms of carbon including polycrystalline graphite, pyrolytic graphite, and PVD-infiltrated and pyrolized carbon-carbon composites. Sputter yield data are presented for pyrolytic graphite and carbon-carbon composite over a range of xenon ion energies from 200 eV to 1 keV and angles of incidence from 0 deg (normal incidence) to 60 deg .

Williams, John D.↗

Does the identification of simple features require serial processing?

Several recent studies have shown performance decrements with increasing display size when background texture elements are present in a same-different feature discrimination task--a result that challenges the traditional notion that the identities of simple visual features are processed in parallel, preattentively. Four experiments are reported that explore the implications of these results. Experiment 1 replicates the recent studies but limits the generalizability of the results to small target numbers. Experiments 2 and 3 show that the observed performance decrements are not due to a serial or even limited-capacity, parallel process. Experiment 4 suggests that decision factors idiosyncratic to the use of texture elements in a same-different task are responsible for the effect. It is concluded that the identification of simple visual features proceeds in parallel, with unlimited capacity (i.e., preattentively).

Pattern Recognition, Visual↗

Automated Target Planning for FUSE Using the SOVA Algorithm

The SOVA algorithm was originally developed under the Resilient Systems and Operations Project of the Engineering for Complex Systems Program from NASA s Aerospace Technology Enterprise as a conceptual framework to support real-time autonomous system mission and contingency management. The algorithm and its software implementation were formulated for generic application to autonomous flight vehicle systems, and its efficacy was demonstrated by simulation within the problem domain of Unmanned Aerial Vehicle autonomous flight management. The approach itself is based upon the precept that autonomous decision making for a very complex system can be made tractable by distillation of the system state to a manageable set of strategic objectives (e.g. maintain power margin, maintain mission timeline, and et cetera), which if attended to, will result in a favorable outcome. From any given starting point, the attainability of the end-states resulting from a set of candidate decisions is assessed by propagating a system model forward in time while qualitatively mapping simulated states into margins on strategic objectives using fuzzy inference systems. The expected return value of each candidate decision is evaluated as the product of the assigned value of the end-state with the assessed attainability of the end-state. The candidate decision yielding the highest expected return value is selected for implementation; thus, the approach provides a software framework for intelligent autonomous risk management. The name adopted for the technique incorporates its essential elements: Strategic Objective Valuation and Attainability (SOVA). Maximum value of the approach is realized for systems where human intervention is unavailable in the timeframe within which critical control decisions must be made. The Far Ultraviolet Spectroscopic Explorer (FUSE) satellite, launched in 1999, has been collecting science data for eight years.[1] At its beginning of life, FUSE had six gyros in two IRUs and four reaction wheels. Over time through various failures, the satellite has been left with one reaction wheel on the vehicle skew axis and two gyros. To remain operational, a control scheme has been implemented using the magnetic torque rods and the remaining momentum wheel.[2] As a consequence, there are attitude regions where there is insufficient torque authority to overcome environmental disturbances (e.g. gravity gradient torques). The situation is further complicated by the fact that these attitude regions shift inertially with time as the spacecraft moves through earth s magnetic field during the course of its orbit. Under these conditions, the burden of planning targets and target-to-target slew maneuvers has increased significantly since the beginning of the mission.[3] Individual targets must be selected so that the magnetic field remains roughly aligned with the skew wheel axis to provide enough control authority to the other two orthogonal axes. If the field moves too far away from the skew axis, the lack of control authority allows environmental torques to pull the satellite away from the target and can potentially cause it to tumble. Slew maneuver planning must factor the stability of targets at the beginning and end, and the torque authority at all points along the slew. Due to the time varying magnetic field geometry relative to any two inertial targets, small modifications in slew maneuver timing can make large differences in the achievability of a maneuver.

Heatwole, Scott↗

An Instrument to Enable Identification of Anthropogenic CO2 Emissions Using Concurrent CO Measurements

We have developed an instrument concept that will enable the measurement of CO from the top of the atmosphere to the Earth's surface with very high sensitivity and at the high spatial and temporal resolutions required by the NRC Decadal Survey mission Active Sensing of Carbon Dioxide (CO2) over Nights, Days and Seasons (ASCENDS). We are developing an innovative CO sensor that will enable the ASCENDS mission to differentiate between anthropogenic and natural sources and sinks of global carbon. The NRC Decadal Survey places particular emphasis on retrieving CO information for the planetary boundary layer. Measurement made using both the 2.3 micron and 4.7 micron channels are needed to achieve the sensitivity required in the lower atmosphere where the degree of CO - CO2 correlation is indicative of anthropogenic sources of CO2. Measurements made using only the 4.7 micron channel cannot provide sufficient sensitivity to CO in the very lowest layers of the atmosphere. The fundamental method we use is Gas Filter Correlation Radiometry (GFCR), a highly successful technique used in other airborne and space-based missions for detecting trace species in the Earth's atmosphere. Our version of GFCR overcomes many of the limitations encountered by prior and existing instruments, allowing us to measure weak signals from small targets very quickly and with extremely high specificity by employing a new dual beam radiometer concept using a focal plane array. Our design will provide a means to make the desired CO measurements for the ASCENDS mission. A simple change in gas filter cell contents would allow the same hardware to measure CH4 with high precision under the nominal ASCENDS mission spatial and temporal constraints. All critical components in the sensor design are mature, many subsystems tested, and the system has been extensively modeled, bringing it to a present Technology Readiness Level (TRL) of 3 (though some individual components are at TRLs 6-9). We are presently developing critical components for the new spectrometer and advancing our understanding of the measurement requirements for both CO and CH4. This new GFCR technique/sensor will enable measurements of trace gases with high sensitivity while maintaining the inherent robustness and simplicity of the more traditional radiometer hardware. Initial estimates of cost/risk of a spacebased 2-channel GFCR indicate that our design is extremely cost effective and will fit within existing ASCENDS mission budget constraints as determined by the NRC Decadal Survey and a NASA-sponsored mission study.

Cook, William B.↗

Support Routines for In Situ Image Processing

This software consists of a set of application programs that support ground-based image processing for in situ missions. These programs represent a collection of utility routines that perform miscellaneous functions in the context of the ground data system. Each one fulfills some specific need as determined via operational experience. The most unique aspect to these programs is that they are integrated into the large, in situ image processing system via the PIG (Planetary Image Geometry) library. They work directly with space in situ data, understanding the appropriate image meta-data fields and updating them properly. The programs themselves are completely multimission; all mission dependencies are handled by PIG. This suite of programs consists of: (1)marscahv: Generates a linearized, epi-polar aligned image given a stereo pair of images. These images are optimized for 1-D stereo correlations, (2) marscheckcm: Compares the camera model in an image label with one derived via kinematics modeling on the ground, (3) marschkovl: Checks the overlaps between a list of images in order to determine which might be stereo pairs. This is useful for non-traditional stereo images like long-baseline or those from an articulating arm camera, (4) marscoordtrans: Translates mosaic coordinates from one form into another, (5) marsdispcompare: Checks a Left Right stereo disparity image against a Right Left disparity image to ensure they are consistent with each other, (6) marsdispwarp: Takes one image of a stereo pair and warps it through a disparity map to create a synthetic opposite- eye image. For example, a right eye image could be transformed to look like it was taken from the left eye via this program, (7) marsfidfinder: Finds fiducial markers in an image by projecting their approximate location and then using correlation to locate the markers to subpixel accuracy. These fiducial markets are small targets attached to the spacecraft surface. This helps verify, or improve, the pointing of in situ cameras, (8) marsinvrange: Inverse of marsrange . given a range file, re-computes an XYZ file that closely matches the original. . marsproj: Projects an XYZ coordinate through the camera model, and reports the line/sample coordinates of the point in the image, (9) marsprojfid: Given the output of marsfidfinder, projects the XYZ locations and compares them to the found locations, creating a report showing the fiducial errors in each image. marsrad: Radiometrically corrects an image, (10) marsrelabel: Updates coordinate system or camera model labels in an image, (11) marstiexyz: Given a stereo pair, allows the user to interactively pick a point in each image and reports the XYZ value corresponding to that pair of locations. marsunmosaic: Extracts a single frame from a mosaic, which will be created such that it could have been an input to the original mosaic. Useful for creating simulated input frames using different camera models than the original mosaic used, and (12) merinverter: Uses an inverse lookup table to convert 8-bit telemetered data to its 12-bit original form. Can be used in other missions despite the name.

Deen, Robert G.↗

Cryo-EM structure determination of small therapeutic protein targets at 3 Å-resolution using a rigid imaging scaffold

Cryoelectron microscopy (Cryo-EM) has enabled structural determination of proteins larger than about 50 kDa, including many intractable by any other method, but it has largely failed for smaller proteins. Here, we obtain structures of small proteins by binding them to a rigid molecular scaffold based on a designed protein cage, revealing atomic details at resolutions reaching 2.9 Å. We apply this system to the key cancer signaling protein KRAS (19 kDa in size), obtaining four structures of oncogenic mutational variants by cryo-EM. Importantly, a structure for the key G12C mutant bound to an inhibitor drug (AMG510) reveals significant conformational differences compared to prior data in the crystalline state. The findings highlight the promise of cryo-EM scaffolds for advancing the design of drug molecules against small therapeutic protein targets in cancer and other human diseases.

59 BASIC BIOLOGICAL SCIENCES↗

Discovery and Development of a Small-Molecule Inhibitor Targeting the GAS41 YEATS Domain in Nonsmall Cell Lung Cancer

Abstract GAS41 is frequently overexpressed in Non-Small Cell Lung Cancer (NSCLC). GAS41 contains a YEATS domain, which recognizes acetylated lysine residues on histones to recruit protein complexes and facilitate transcription. Suppression of GAS41 in NSCLC models inhibits cellular proliferation and markedly reduces tumor growth in mouse xenografts, justifying the development of small-molecule inhibitors. We have employed structure-based design and medicinal chemistry optimization to discover DLG-41, a submicromolar inhibitor binding to the GAS41 YEATS domain. DLG-41 potently disrupts the association of GAS41 YEATS with chromatin in mammalian cells and inhibits the proliferation of NSCLC cell lines with submicromolar potency without significantly affecting normal lung fibroblasts. DLG-41 induces more effective growth inhibition in A549 versus GAS41-knockout cells, demonstrating on-target activity. DLG-41 treatment upregulates the CDKN1A gene and downregulates pathways associated with lung cancer cell identity, tumor migration, and invasion. DLG-41 is a promising chemical probe for targeting GAS41 protein in NSCLC models and has potential for future development.

Listunov, Dymytrii [University of Michigan , , , ,↗

Autonomous target tracking of small bodies during flybys

Spacecraft flybys of small solar system bodies provide important science return in the form of images of the target body taken around closest approach. In order to maximize the number of images taken of the target, an autonomous closed-loop tracking system has been developed to maintain lock on the target during the flyby. The system uses images to estimate the spacecrafts target-relative position and attitude, which is then used to point the camera. The system has been successfully used twice: the Deep Space 1 flyby of comet Borrelly and the Stardust flyby of asteroid Annefrank. This paper describes in detail the tracking algorithms and flight results.

Synnott, Stephen P.↗

Quantification and evaluation of strain reduction from small-bubble gas injection in Spallation Neutron Source target vessels

Small-bubble gas injection has been routinely utilized in the operation of Spallation Neutron Source (SNS) mercury targets since 2017 to mitigate cavitation-induced erosion damage to target vessels. Strain measurements of target vessels collected in-situ during initial operation with gas injection were used to study the gas injection effect on the structural response of targets to proton pulses. A significant strain reduction owing to gas injection was found by comparing the strain measurement data during operation with and without gas injection. The research presented here focuses on quantifying strain reductions in SNS targets and evaluating the effect of small-bubble gas injection by comparing different bubbler types and target designs. The strain measurement results show the gas injection significantly reduced strain in SNS target vessels; strain values decreased by 30% to 80% for targets operating with gas injection. Stress and strain responses of SNS targets were simulated to numerically evaluate the gas injection effect. Based on the predicted stresses with and without gas injection, the fatigue lifetimes of SNS jet-flow design target were estimated using fe-safe fatigue analysis software. The simulations show these reductions should improve the fatigue life of target vessels and allow SNS targets to meet their fatigue design goal.

Fatigue life estimation↗

Targeted protein degradation: from small molecules to complex organelles—a Keystone Symposia report

Targeted protein degradation is critical for proper cellular function and development. Protein degradation pathways, such as the ubiquitin proteasomes system, autophagy, and endosome–lysosome pathway, must be tightly regulated to ensure proper elimination of misfolded and aggregated proteins and regulate changing protein levels during cellular differentiation, while ensuring that normal proteins remain unscathed. Protein degradation pathways have also garnered interest as a means to selectively eliminate target proteins that may be difficult to inhibit via other mechanisms. Additionally, on June 7 and 8, 2021, several experts in protein degradation pathways met virtually for the Keystone eSymposium “Targeting protein degradation: from small molecules to complex organelles.” The event brought together researchers working in different protein degradation pathways in an effort to begin to develop a holistic, integrated vision of protein degradation that incorporates all the major pathways to understand how changes in them can lead to disease pathology and, alternatively, how they can be leveraged for novel therapeutics.

59 BASIC BIOLOGICAL SCIENCES↗

An Integral Activity-Based Protein Profiling Method for Higher Throughput Determination of Protein Target Sensitivity to Small Molecules

Activity-based protein profiling (ABPP) is a chemoproteomic technique that uses small molecule probes to label active enzymes selectively and covalently in complex proteomes. Competitive ABPP, which involves treatment of the active proteome with an analyte of interest, is especially powerful for profiling how small molecules impact specific protein activities. Advances in higher throughput workflows have made it possible to generate extensive competitive ABPP data across diverse biological samples, making this approach highly appealing for characterizing shared and unique proteins affected by perturbations such as drug or chemical exposures. To use the competitive ABPP approach effectively to understand potential adverse effects of chemicals of concern (CoC), a wide range of concentrations may be needed, particularly for chemicals that lack potency or toxicity data. In this work, we present an integral competitive ABPP method that enables target sensitivity determination for different organophosphate (OP) pesticides as model toxicants. Using previously developed OP-ABPs, we optimized conditions for tandem mass tag (TMT) multiplexing of ABPP samples and compared conventional competitive ABPP involving samples at discrete paraoxon concentrations to pooled samples across that same concentration range. We then expanded our approach to compare protein target sensitivities toward two additional OP pesticides, chlorpyrifos oxon and malaoxon. The results showed that differences in integral intensities for the pooled competition sample can be used to evaluate the relative sensitivity of specific proteins without increasing the overall number of samples. For 8 CoC concentrations of interest, this strategy reduced the number of TMT plexes and the corresponding number of LC–MS/MS analyses 3-fold. In conclusion, we envision the integral ABPP (IABPP) method will provide a means to screen diverse chemicals more rapidly to identify both high and low sensitivity protein targets.

activity-based probes↗