Search NASA⌕ Search

SEARCH · Search NASA

Results for “smooth pursuit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

51 records · Page 3

A new quantitative indicator of visual fatigue

Ocular-motor correlates of visual fatigue have remained elusive. Performance of ocular-motor tracking with a wide-band white noise input and the response of the dual-mode, smooth pursuit-saccadic eye movement system as output was used to test visual fatigue. A new visual fatigue indicator, VFI, was defined as the nonlinear remnant after subtracting an identified impulse response contribution to the output. Subjects were required to perform very fatiguing CRT screen reading tasks, and the VFI correlated well with the subjective reports of visual fatigue.

Goussard, Yves↗

Oculometric Biomarkers of Visuomotor Deficits in Clinically Asymptomatic Patients With Systemic Lupus Erythematosus Undergoing Long-Term Hydroxychloroquine Treatment

Introduction: This study examines a set of oculomotor measurements, or “oculometric” biomarkers, as potential early indicators of visual and visuomotor deficits due to retinal toxicity in asymptomatic Systemic Lupus Erythematosus (SLE) patients on long-term hydroxychloroquine (HCQ) treatment. The aim is to identify subclinical functional impairments that are otherwise undetectable by standard clinical tests and to link them to structural retinal changes. Methods: We measured oculomotor responses in a cohort of SLE patients on chronic HCQ therapy using a previously established behavioral task and analysis technique. We also examined the relationship between oculometrics, OCT measures of retinal thickness, and standard clinical perimetry measures of visual function in our patient group using Bivariate Pearson Correlation and a Linear Mixed-Effects Model (LMM). Results: Significant visual and visuomotor deficits were found in 12 asymptomatic SLE patients on long-term HCQ therapy compared to a cohort of 17 age-matched healthy controls. Notably, six oculometrics were significantly different. The median initial pursuit acceleration was 22%, steady-state pursuit gain 16%, proportion smooth 7%, and target speed responsiveness 31% lower, while catch-up saccade amplitude was 46% and fixation error 46% larger. Excluding the two patients with diagnosed mild toxicity, four oculometrics, all but fixation error and proportion smooth, remained significantly impaired compared to controls. Across our population of 12 patients (24 retinae), we found that pursuit latency, initial acceleration, steady-state gain, and fixation error were linearly related to retinal thickness even when age was accounted for, while standard measures of clinical function (Mean Deviation and Pattern Standard Deviation) were not. Discussion: Our data show that specific oculometrics are sensitive early biomarkers of functional deficits in SLE patients on HCQ that could be harnessed to assist in the early detection of HCQ-induced retinal toxicity and other visual pathologies, potentially providing early diagnostic value beyond standard visual field and OCT evaluations.

eye movements↗

Pursuit Latency for Chromatic Targets

The temporal dynamics of eye movement response to a change in direction of stimulus motion has been used to compare the processing speeds of different types of stimuli (Mulligan, ARVO '97). In this study, the pursuit response to colored targets was measured to test the hypothesis that the slow response of the chromatic system (as measured using traditional temporal sensitivity measures such as contrast sensitivity) results in increased eye movement latencies. Subjects viewed a small (0.4 deg) Gaussian spot which moved downward at a speed of 6.6 deg/sec. At a variable time during the trajectory, the dot's direction of motion changed by 30 degrees, either to the right or left. Subjects were instructed to pursue the spot. Eye movements were measured using a video ophthalmoscope with an angular resolution of approximately 1 arc min and a temporal sampling rate of 60 Hz. Stimuli were modulated in chrominance for a variety of hue directions, combined with a range of small luminance increments and decrements, to insure that some of the stimuli fell in the subjects' equiluminance planes. The smooth portions of the resulting eye movement traces were fit by convolving the stimulus velocity with an exponential having variable onset latency, time constant and amplitude. Smooth eye movements with few saccades were observed for all stimuli. Pursuit responses to stimuli having a significant luminance component are well-fit by exponentials having latencies and time constants on the order of 100 msec. Increases in pursuit response latency on the order of 100-200 msec are observed in response to certain stimuli, which occur in pairs of complementary hues, corresponding to the intersection of the stimulus section with the subjects' equiluminant plane. Smooth eye movements can be made in response to purely chromatic stimuli, but are slower than responses to stimuli with a luminance component.

Mulligan, Jeffrey B.↗

Perceived visual motion as effective stimulus to pursuit eye movement system

Human eye tracking of a foveal afterimage during angular head oscillation in the dark produced smooth eye movements exceeding those for normal vestibular nystagmus, and a reduction in the frequency of the fast phase component of nystagmus eye movements. These results may support a closed loop extension of the corollary discharge theory, with oculomotor commands based on perceived object velocity.

Yasui, S.↗

Low-Dose Caffeine Administration During Acute Sleep Deprivation Eliminates Visual Motion Processing Impairment, but Does Not Improve Saccadic Rate

Oculomotor tracking performance changes according to time awake. A constant routine (CR) study demonstrated that increasing time awake 1) reduces the precision of visual motion processing, 2) decreases steady-state closed-loop pursuit performance and 3) decreases peak saccadic velocity. We aimed to determine the contribution of homeostatic sleep pressure on these oculometric changes by administering low-dose caffeine over one night of sleep deprivation. Participants completed two weeks of at-home 8.5 hours sleep per day, followed by an approximately 24-hour laboratory CR in semi-recumbent posture under less than 4 lux of light. The visual tracking task was performed every two hours after waking and hourly overnight. Low-dose caffeine of 0.3 milligrams per kilogram was administered hourly during the biological night. Nine participants (5F) completed the study. Caffeine dosing: 1) prevented the impairment of visual motion processing, 2) reduced by approximately half the impairment of closed-loop pursuit performance (gain, minus 0.47 percent per hour, significance of slope change: p (probability) less than 0.006; proportion smooth, minus 0.35 percent per hour, p less than 0.005), and 3) had an insignificant (p less than 0.39) effect on the impairment of saccadic peak velocity (slope, minus 1.13 percent per hour; intercept, minus 0.62 percent per hour). These results suggest that visual motion processing and some proportion of closed-loop pursuit performance are impaired due to homeostatic mechanisms during sleep deprivation.

Sleep↗

Comprehensive Oculomotor Behavioral Response Assessment (COBRA)

An eye movement-based methodology and assessment tool may be used to quantify many aspects of human dynamic visual processing using a relatively simple and short oculomotor task, noninvasive video-based eye tracking, and validated oculometric analysis techniques. By examining the eye movement responses to a task including a radially-organized appropriately randomized sequence of Rashbass-like step-ramp pursuit-tracking trials, distinct performance measurements may be generated that may be associated with, for example, pursuit initiation (e.g., latency and open-loop pursuit acceleration), steady-state tracking (e.g., gain, catch-up saccade amplitude, and the proportion of the steady-state response consisting of smooth movement), direction tuning (e.g., oblique effect amplitude, horizontal-vertical asymmetry, and direction noise), and speed tuning (e.g., speed responsiveness and noise). This quantitative approach may provide fast and results (e.g., a multi-dimensional set of oculometrics and a single scalar impairment index) that can be interpreted by one without a high degree of scientific sophistication or extensive training.

Stone, Leland S.↗

Pursuit Eye Movements

When viewing objects, primates use a combination of saccadic and pursuit eye movements to stabilize the retinal image of the object of regard within the high-acuity region near the fovea. Although these movements involve widespread regions of the nervous system, they mix seamlessly in normal behavior. Saccades are discrete movements that quickly direct the eyes toward a visual target, thereby translating the image of the target from an eccentric retinal location to the fovea. In contrast, pursuit is a continuous movement that slowly rotates the eyes to compensate for the motion of the visual target, minimizing the blur that can compromise visual acuity. While other mammalian species can generate smooth optokinetic eye movements - which track the motion of the entire visual surround - only primates can smoothly pursue a single small element within a complex visual scene, regardless of the motion elsewhere on the retina. This ability likely reflects the greater ability of primates to segment the visual scene, to identify individual visual objects, and to select a target of interest.

Krauzlis, Rich↗

From following edges to pursuing objects

Primates can generate accurate, smooth eye-movement responses to moving target objects of arbitrary shape and size, even in the presence of complex backgrounds and/or the extraneous motion of non-target objects. Most previous studies of pursuit have simply used a spot moving over a featureless background as the target and have thus neglected critical issues associated with the general problem of recovering object motion. Visual psychophysicists and theoreticians have shown that, for arbitrary objects with multiple features at multiple orientations, object-motion estimation for perception is a complex, multi-staged, time-consuming process. To examine the temporal evolution of the motion signal driving pursuit, we recorded the tracking eye movements of human observers to moving line-figure diamonds. We found that pursuit is initially biased in the direction of the vector average of the motions of the diamond's line segments and gradually converges to the true object-motion direction with a time constant of approximately 90 ms. Furthermore, transient blanking of the target during steady-state pursuit induces a decrease in tracking speed, which, unlike pursuit initiation, is subsequently corrected without an initial direction bias. These results are inconsistent with current models in which pursuit is driven by retinal-slip error correction. They demonstrate that pursuit models must be revised to include a more complete visual afferent pathway, which computes, and to some extent latches on to, an accurate estimate of object direction over the first hundred milliseconds or so of motion.

NASA Discipline Neuroscience↗

Technology-enabled Airborne Spacing and Merging

Over the last several decades, advances in airborne and groundside technologies have allowed the Air Traffic Service Provider (ATSP) to give safer and more efficient service, reduce workload and frequency congestion, and help accommodate a critically escalating traffic volume. These new technologies have included advanced radar displays, and data and communication automation to name a few. In step with such advances, NASA Langley is developing a precision spacing concept designed to increase runway throughput by enabling the flight crews to manage their inter-arrival spacing from TRACON entry to the runway threshold. This concept is being developed as part of NASA s Distributed Air/Ground Traffic Management (DAG-TM) project under the Advanced Air Transportation Technologies Program. Precision spacing is enabled by Automatic Dependent Surveillance-Broadcast (ADS-B), which provides air-to-air data exchange including position and velocity reports; real-time wind information and other necessary data. On the flight deck, a research prototype system called Airborne Merging and Spacing for Terminal Arrivals (AMSTAR) processes this information and provides speed guidance to the flight crew to achieve the desired inter-arrival spacing. AMSTAR is designed to support current ATC operations, provide operationally acceptable system-wide increases in approach spacing performance and increase runway throughput through system stability, predictability and precision spacing. This paper describes problems and costs associated with an imprecise arrival flow. It also discusses methods by which Air Traffic Controllers achieve and maintain an optimum interarrival interval, and explores means by which AMSTAR can assist in this pursuit. AMSTAR is an extension of NASA s previous work on in-trail spacing that was successfully demonstrated in a flight evaluation at Chicago O Hare International Airport in September 2002. In addition to providing for precision inter-arrival spacing, AMSTAR provides speed guidance for aircraft on converging routes to safely and smoothly merge onto a common approach. Much consideration has been given to working with operational conditions such as imperfect ADS-B data, wind prediction errors, changing winds, differing aircraft types and wake vortex separation requirements. A series of Monte Carlo simulations are planned for the spring and summer of 2004 at NASA Langley to further study the system behavior and performance under more operationally extreme and varying conditions. This will coincide with a human-in-the-loop study to investigate the flight crew interface, workload and acceptability.

Hull, James↗

Correlated Changes in Retinal Thickness and Visuomotor Function in Asymptomatic Plaquenil Toxicity Patients

We have previously shown that a 5-minute eye-movement test can capture a number of largely independent “oculometric” parameters of human visual/visuomotor function (Liston & Stone, 2014). This test has been successfully used to characterize mild neural impairment due to traumatic brain injury, sleep and circadian disruption, and alcohol consumption (Liston et al., 2017; Stone et al, 2019; Tyson et al, 2021). Here, we extend this approach to study patients at risk of progressive posterior-segment illness to see how oculometrics relate to standard clinical ophthalmological measures. Five female patients (<20:40 BCVA, 34-60 years old) undergoing hydroxychloroquine treatment (2-7mg/kg/day for 10-23 years for rheumatologic illness) have participated thus far. Under monocular viewing conditions in randomized order, they tracked a moving spot undergoing radial step-ramp motion in one of 90 randomized directions, at one of 5 randomized speeds, starting at random times (for details, see Stone et al, 2019). We computed nine independent oculometrics (latency, initial acceleration, steady-state gain, proportion smooth, saccadic rate, saccadic amplitude, direction noise, speed responsiveness, and speed noise). Spectral-domain optical coherence tomography (Zeiss, Dublin, CA) was used to measure the average thickness of the nine Early Treatment Diabetic Retinopathy Study macular sectors from the internal limiting membrane to the retinal pigmented epithelium. We used Pearson’s correlation between retinal thickness and our oculometrics with t-statistics to test separate one-sided hypotheses across 10 retinae. Our preliminary analysis found significant changes in several different aspects of visuomotor performance. Most notably, latency increased, initial acceleration decreased, and steady-state pursuit gain decreased as retinal thickness decreased (r2 = 0.364, 0.579, and 0.692; one-tailed P = 0.032, 0.005, and 0.001, respectively). Speed responsiveness appeared to decrease, but this effect was marginal for our current sample (r2 = 0.253, P = 0.069). Lastly, direction discrimination and saccadic behavior appeared unchanged. We conclude that oculometrics may provide sensitive measures of changes in retinal thickness. More importantly, oculometrics have the potential to detect impairment before it becomes evident with standard clinical imaging tools, while also providing insight into the behavioral implications of any resulting deficits in visual/visuomotor function.

eye movements↗

TOWARD A METHOD FOR SCALING HUMAN BODY MODELS IN AN IMU-BASED WORKFLOW

BACKGROUND Scaled biomechanical models can more accurately inform crew health decisions when tailored to the wide range of astronaut sizes. One component to improve scaling of existing models to better represent each unique astronaut’s size is the individual length scaling of limbs. Traditionally, these lengths are determined by motion capture or manual measurement. A new method is herein proposed for length scaling which can be done by measuring linear and angular accelerations at a desired point during isolated motion around a point of rotation, then calculating the distance between the desired point and point of rotation. When an Inertial Measurement Unit (IMU) device is placed at the distal point of a limb, the isolated motion is about that limb’s proximal joint. For example, to measure forearm length, an IMU is placed at the wrist, the point of rotation is at the elbow, and the isolated motion is forearm flexion and extension. These calculated lengths are then used to scale models to each unique astronaut’s size, thereby improving the applicability of the model. This method of scaling limb segments can be used for any limb that has an easily defined proximal joint for the limb to rotate around including hands, arms, legs, feet. Utilizing IMUs for data collection also provides the synergistic ability to record data without a dedicated space in a room with many cameras, therefore reducing the data collection footprint, or record data where optical motion capture is not possible, such as inside a spacesuit. METHODS AND RESULTS To test this method, upper body data collection was performed with 5 Xsens DOT IMUs on a single subject. IMUs consist of an accelerometer, a gyroscope, and a magnetometer which collect linear acceleration, angular velocity, and magnetic fluctuations, respectively. Before any ground-based laboratory collection, the magnetic fluctuations are used to correct the heading of the IMU in space relative to the Earth’s magnetic field. The direct measurement of angular velocity is integrated to calculate angular acceleration. Then the linear acceleration ( a ) and angular acceleration (α) are solved using r = at/α to calculate the radius, which in this case is the distance between the IMU and the point of rotation (i.e., segment length). The IMU must be placed at the most distal point of the limb being measured (i.e., ankle if measuring lower leg length) and the test plan must consist of an isolated motion about that limb’s proximal joint (i.e., knee flexion and extension if measuring lower leg length). The distances (radii) calculated at every time interval were filtered (bandpass filter keeping 5th-90th percentile data) to eliminate outliers and spurious data that occur when the isolated motion was stopped or nearly stopped. The remaining distances were averaged, resulting in the calculated limb length. Scaling factors were then computed by dividing the calculated limb length by the unscaled model’s length. These scale factors are plugged into the Scale Tool in OpenSim [1,2] to apply the scaling to the OpenSim Full Body Rajagopal Model [3,4]. Manual measurements of limb lengths were taken before data collection started and used for comparing against the calculated lengths. The Anthropometric Survey of US Army Personnel (ANSUR II) [5] was also used as a third source of reference for limb length measurements. The following measurements were retrieved from the subject before data collection: 34.5 cm from L1 to C7 (thorax), 25.7 cm from C7 Joint Center (JC) to head vertex (neck and head), 36.3 cm from shoulder JC to elbow JC (humerus), 29.5 cm from elbow JC to wrist JC (forearm), and 16.2 cm from clavicle to acromion (clavicle). Of those five, forearm and humerus lengths were calculated using this proposed method to obtain preliminary results. The forearm length after filtering and averaging was calculated to be 37.6 cm. This is a 28% overestimation from the measured forearm length (29.5 cm). The humerus length after filtering and averaging was calculated to be 47.8 cm. This is a 31% difference from the measured subject length (36.3 cm). Sources of error include imperfect isolated motion (method currently expects that motion should be perfectly circular in a 2D plane, include no rotation of the IMU, and be relatively smooth; a more secure IMU attachment method will help), unrefined filter techniques (removed highest and lowest values with 20% high and low pass filters and no smoothing filters), arbitrary removal of stopped or near stopped data (kept data for only a short range before and after the angular velocity peaking), and a more representative method for removing gravitational acceleration is needed (current method is to zero all accelerations against a baseline taken just before the isolated motion which does not account for the gravitational acceleration changed due to IMU rotation during movement). Addressing these error sources will improve the accuracy of the limb length calculation. Next steps include creating a method for whole-body scaling estimation using individual limb scale factors. Continued pursuit of these techniques is expected to enable acquiring anthropometric information using only IMUs in real-time.

E. K. Marecki↗

Effect of vergence on the gain of the linear vestibulo-ocular reflex

We measured the linear vestibulo-ocular reflex (LVOR) and vergence, using binocular search coils, in 3 humans. The subjects were accelerated sinusoidally at 0.5 Hz and 0.2 g peak acceleration, in complete darkness, while performing three different tasks: i) mental arithmetic; ii) tracking a remembered target at either 0.34 m or 0.14 m distance; and iii) maintaining vergence at either of these distances by means of audio biofeedback based on vergence. Subjects could control vergence using the audio feedback; there was greater convergence with the near audio target. However, there was no significant difference in vergence between the near and far remembered target conditions. With audio feedback, the amplitude of smooth tracking was not consistently different for the near and the far conditions. However, the amplitude of tracking (saccades and smooth component) in the remembered target conditions was greater for near than for far targets. These results suggest that linear VOR amplitude is not determined by vergence alone.

NASA Program Space Physiology and Countermeasures↗

Experimental Investigation of Flow Condensation in Microgravity

Future manned missions to Mars are expected to greatly increase the space vehicle's size, weight, and heat dissipation requirements. An effective means to reducing both size and weight is to replace single-phase thermal management systems with two-phase counterparts that capitalize upon both latent and sensible heat of the coolant rather than sensible heat alone. This shift is expected to yield orders of magnitude enhancements in flow boiling and condensation heat transfer coefficients. A major challenge to this shift is a lack of reliable tools for accurate prediction of two-phase pressure drop and heat transfer coefficient in reduced gravity. Developing such tools will require a sophisticated experimental facility to enable investigators to perform both flow boiling and condensation experiments in microgravity in pursuit of reliable databases. This study will discuss the development of the Flow Boiling and Condensation Experiment (FBCE) for the International Space Station (ISS), which was initiated in 2012 in collaboration between Purdue University and NASA Glenn Research Center. This facility was recently tested in parabolic flight to acquire condensation data for FC-72 in microgravity, aided by high-speed video analysis of interfacial structure of the condensation film. The condensation is achieved by rejecting heat to a counter flow of water, and experiments were performed at different mass velocities of FC-72 and water and different FC-72 inlet qualities. It is shown that the film flow varies from smooth-laminar to wavy-laminar and ultimately turbulent with increasing FC-72 mass velocity. The heat transfer coefficient is highest near the inlet of the condensation tube, where the film is thinnest, and decreases monotonically along the tube, except for high FC-72 mass velocities, where the heat transfer coefficient is enhanced downstream. This enhancement is attributed to both turbulence and increased interfacial waviness. One-ge correlations are shown to predict the average condensation heat transfer coefficient with varying degrees of success, and a recent correlation is identified for its superior predictive capability, evidenced by a mean absolute error of 21.7%.

microgravity↗

A One-Dimensional Global-Scaling Erosive Burning Model Informed by Blowing Wall Turbulence

This paper makes no attempt to comprehensively review erosive burning models or the data collected in pursuit of them; the interested reader could begin with Landsbaum for a historical summary. However, a discussion and comparison to recent work by McDonald and Rettenmaier and Heister will be included, along with data generated by Strand, et. al. Suffice it to say that the search for a way to predict erosive burning in any size motor with formulas cleanly applicable to a typical 1D ballistics analysis has been long thwarted. Some models were based on testing that failed to adequately simulate the solid rocket motor environment. In most cases, no real‐time burn rate measurement was available. Two popular models, even when calibrated to recent motor‐like real‐time burn rate data obtained by Furfaro, were shown by McMillin to be inadequate at modeling erosive burning in the Space Shuttle Reusable Solid Rocket Motor (RSRM), the Space Launch Systems' Five‐Segment RSRM (RSRMV), and the five‐segment Engineering Test Motor (ETM)‐3. Subsequently to the data cited from Strand and Furfaro, additional motors of the same kind as Furfaro's were tested with RSRMV propellant, utilizing 7 segments per motor and 3 throat sizes. By measuring propellant web thickness with ultrasonic gages, the burn rate was determined at cross‐flow Mach numbers up to Mach 0.8. Furthermore, because of the different throat sizes in otherwise identical motors, this provides a unique look at the effect of pressure and base burn rate on the erosive response. Figure 1 shows example of the data pertaining to the high Mach motor, where the port area is initially less than the throat area. The burn rate data was processed using a smoothing method developed to reduce the noise without too severely introducing end effects that limit the range of useful data. Then, an empirical ballistics scheme was used to estimate the flow condition based on the burn rate measurements and pressure measured between each segment.

Kibbey, Timothy P.↗

Quantifying the Correlation Between Eye-Movement and Perceptual Responses to Moving Plaids

To determine the extent to which the pursuit eye-movement and perceptual systems share a common neural motion-processing pathway, we simultaneously measure the psychophysical and eye-movement responses to drifting plaids in a direction-discrimination task. Correlation between the noise in the eye movements and percepts would suggest a shared neural substrate. Three observers were asked to track a plaid (Type I 90 deg; TF = 4 Hz, SF = 0.6 c/d; direction = -2, 0, or 2 deg), and to respond whether the motion was to the right or left of vertical. The eye-movement direction is computed from the initial 300 ms of saccade-free tracking (near open-loop). On each trial, we use the eye-movement direction to predict the perceptual response. We then compute the probability of successfully predicting the observer's response. We also use SOC analysis as an alternate measure of the correlation. We compare the data from both these analyses to the predictions of two models in which the eye movements and the percept are driven by either a common noisy signal (correlated model) or by two separate noisy signals (uncorrelated model). We also allow for the fact that our measured eye movements are degraded by eye-tracker noise. This noise causes our measured correlation to be lower than the actual biological correlation. The correlations in our data are higher than those predicted by the uncorrelated model, and are similar to the predictions of the correlated model. The proportion of perceptual responses correctly predicted by the eye movements were 0.66, 0.60, 0.73 for the -2, 0, 2 deg stimuli respectively (correlated model 0.65, 0.60, 0.70; uncorrelated model 0.58, 0.51, 0.60).The SOC proportions were 0.71, 0.64, 0.72 (correlated model 0.66, 0.64, 0.69; uncorrelated model 0.5, 0.5, 0.5). These results show that the oculomotor and perceptual system share a performance-limiting noise source and provide strong evidence that a common neural mechanism (perhaps MT or MST) drives both perception and smooth eye movements.

Beutter, Brent R.↗