Search NASA⌕ Search

SEARCH · Search NASA

Results for “soft modes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Large-amplitude free and driven drop-shape oscillations - Experimental observations

A quantitative study of some nonlinear aspects of drop-shape oscillations in a liquid-liquid system has been completed. The results suggest a soft nonlinearity in the fundamental resonant mode frequency as the oscillation amplitude is increased. Indications of an increase in the rate of decay have also been obtained. A study of the internal flow fields has revealed patterns of circulation not present at low amplitude.

Trinh, E.↗

Challenges of Designing a 13-Hz High-Load Vibration Isolation System with Tight Volume Constraints: Lessons Learned and Path Forward

This paper describes the design of a passive isolation system using D-struts (Registered TradeMark) to isolate an optical payload from aircraft-borne jitter with challenging stroke per volume requirements. It discusses the use of viscoelastic-coated D-struts® that meet the customer performance and outgassing specification, NASA-1124. The result was a relatively soft isolation system, (where the first mode was 13 Hz), with each individual strut capable of withstanding loads on the order of magnitude of 623 N (140 lbf), weighing less than 910 g (2 lbm), fitting in a volume 5.1 cm (2 inches) in diameter and 12-cm (4.7-inches) long and capable of performing up to 1000 Hz without nonlinearities.

Dearing, Stella↗

The detection of photospheric X-ray pulsations from PG 1159-035 with EXOSAT

The detection of soft X-ray pulsations from the hot, helium-rich, degenerate object, PG 1159-035 is reported. These observations, obtained with the Low Energy experiment on EXOSAT, show the presence of large-amplitude soft X-ray (44-150 A) pulsations analogous to several of the low-amplitude, nonradial, g-mode pulsations which are observed in the optical. These soft X-ray pulsations, with periods of 516 s, 524 s, and 539 s, arise from the photosphere of PG 1159-035 and constitute the first observations of stellar atmospheric pulsational phenomena in the X-ray band.

Barstow, M. A.↗

Mshpy23: A User-Friendly, Parameterized Model of Magnetosheath Conditions

Lunar Environment heliospheric X-ray Imager (LEXI) and Solar wind – Magnetosphere - Ionosphere Link Explorer (SMILE) will observe magnetosheath and its boundary motion in soft X-rays for understanding magnetopause reconnection modes under varioussolar wind conditions after their respective launches in 2024 and 2025. Magnetosheath conditions, namely, plasma density, velocity, and temperature, are key parameters for predicting and analyzing soft X-ray images from the LEXI and SMILE missions. We developed a user-friendly model of magnetosheath that parameterizes number density, velocity, temperature, and magnetic field by utilizing the global Magnetohydrodynamics (MHD) model as well as the pre-existing gas-dynamic and analytic models. Using this parameterized magnetosheath model, scientists can easily reconstruct expected soft X-ray images and utilize them for analysis of observed images of LEXI and SMILE without simulating the complicated global magnetosphere models. First, we created an MHD based magnetosheath model by running a total of 14 OpenGGCM global MHD simulations under 7 solar wind densities (1, 5, 10, 15, 20, 25, and 30cm−3) and 2 interplanetary magnetic field BZ components (± 4nT), and then parameterizing the results in new magnetosheath conditions. We compared the magnetosheath model result with THEMIS statistical data and it showed good agreement with a weighted Pearson correlation coefficient greater than 0.77, especially for plasma density and plasma velocity. Second, we compiled a suite of magnetosheath models incorporating previous magnetosheath models (gas-dynamic, analytic), and did two case studies to test the performance. The MHD based model was comparable to or better than the previous models while providing self consistency among the magnetosheath parameters. Third, we constructed a tool to calculate a soft X-ray image from any given vantage point, which can support the planning and data analysis of the aforementioned LEXI and SMILE missions. A release of the code has been uploaded to a Github repository.

Magnetosheath↗

Benefit of "Push-pull" Locomotion for Planetary Rover Mobility

As NASAs exploration missions on planetary terrains become more aggressive, a focus on alternative modes of locomotion for rovers is necessary. In addition to climbing steep slopes, the terrain in these extreme environments is often unknown and can be extremely hard to traverse, increasing the likelihood of a vehicle or robot becoming damaged or immobilized. The conventional driving mode in which all wheels are either driven or free-rolling is very efficient on flat hard ground, but does not always provide enough traction to propel the vehicle through soft or steep terrain. This paper presents an alternative mode of travel and investigates the fundamental differences between these locomotion modes. The methods of push-pull locomotion discussed can be used with articulated wheeled vehicles and are identified as walking or inchinginch-worming. In both cases, the braked non-rolling wheels provide increased thrust. An in-depth study of how soil reacts under a rolling wheel vs. a braked wheel was performed by visually observing the motion of particles beneath the surface. This novel technique consists of driving or dragging a wheel in a soil bin against a transparent wall while high resolution, high-rate photographs are taken. Optical flow software was then used to determine shearing patterns in the soil. Different failure modes were observed for the rolling and braked wheel cases. A quantitative comparison of inching vs. conventional driving was also performed on a full-scale vehicle through a series of drawbar pull tests in the Lunar terrain strength simulant, GRC-1. The effect of tire stiffness was also compared; typically compliant tires provide better traction when driving in soft soil, however its been observed that rigid wheels may provide better thrust when non-rolling. Initial tests indicate up to a possible 40 increase in pull force capability at high slip when inching vs. rolling.

robotics↗

Detector arrays for photometric measurements at soft X-ray, ultraviolet and visible wavelengths

The construction and modes of operation of the Multi-Anode Microchannel Array (MAMA) detectors are described, and the designs of spectrometers utilizing them are outlined. MAMA consists of a curved microchannel array plate, an opaque photocathode (peak quantum efficiency of 19% at 1216 A), and a multi-anode (either discrete- or coincidence-anode) readout array. Designed for use in instruments on spaceborne telescopes, MAMA can be operated in a windowless configuration in extreme-ultraviolet and soft X-ray wavelengths, or in a sealed configuration at UV and visible wavelengths. Advantages of MAMA include low applied potential (less than 3.0 kV), high gain (greater than 10 to the 6th electrons/pulse), low sensitivity to high-energy charged particles, and immunity to external magnetic fields of less than 500 Gauss

Timothy, J. G.↗

Motor Starters

The power factor controller (PFC) was invented by a NASA engineer. It matches voltage with a motor's actual need by sensing shifts in the relationship between voltage and current flow. With the device, power can be trimmed as much as 65%. Intellinet adopted this technology and designed "soft start" and "load-responsive" control modes to start engines gradually and recycle voltage without reducing motor speed. Other features are lower motor heat and faster fault identification.

Source record↗

Performing spectroscopic and specific heat studies of improper ferroelectrics

The results of infrared measurements on Ni-Br, Cu-Cl, and Fe-I boracite improper ferroelectrics and far infrared measurements of Ni-Br boracite are presented. The boracites have the general formula X3B7O3Y, where X = divalent metal and Y = halogen. They undergo a first order phase transition from a high temperature paraelectric phase with cubic symmetry to a ferroelectric phase with orthorhombic symmetry. The boracites are "improper ferroelectrics" since the spontaneous polarization is not the primary order parameter in the cubic-orthorhombic phase transition. Current understanding of these materials is that the primary order parameter is associated with a doubly degenerate zone-boundary phonon in the cubic phase. The degenerate critical modes become homogeneous and split into the A sub 1 and A sub 2 modes in the orthorhombic phase, doubling the volume of the primitive cell. An harmonic coupling between the softing A sub 1 and a low frequency A sub 1 optic mode induces a spontaneous polarization as a secondary effect in the ferroelectric phase. This secondary non-critical nature of the ferroelectric mode earns these materials the "improper" title and is responsible for their unique properties and high figure of merit in detector use.

Coleman, L. B.↗

The Dynamics of Ultrasonically Levitated Drops in an Electric Field

Ultrasonic and electrostatic levitation techniques have allowed the experimental investigation of the nonlinear oscillatory dynamics of free droplets with diameter between 0.1 and 0.4 cm. The measurement of the resonance frequencies of the first three normal modes of large amplitude shape oscillations in an electric field of varying magnitude has been carried out with and without surface charges for weakly conducting liquids in air. These oscillations of nonspherical levitated drops have been driven by either modulating the ultrasonic field or by using a time-varying electric field, and the free decay from the oscillatory state has been recorded. A decrease in the resonance frequency of the driven fundamental quadrupole mode has been measured for increasing oblate deformation in the absence of an electric field. Similarly, a decrease in this frequency has also been found for increasing DC electric field magnitude. A soft nonlinearity exists in the amplitude dependence of the resonant mode frequencies for freely decaying as well as ultrasonically and electrically driven uncharged drops. This decrease in resonance frequency is accentuated by the presence of free surface charge on the drop. Subharmonic resonance excitation has been observed for drops in a time-varying electric field, and hysteresis exists for resonant modes driven to large amplitude. Mode coupling from lower-order resonances to higher-order modes has been found to be very weak, even for fairly large amplitude shape oscillations. Most of these results are in general agreement with predictions from recent analytical and numerical investigations.

Trinh, E. H.↗

The Dynamics of Ultrasonically Levitated Drops in an Electric Field

Ultrasonic and electrostatic leviation techniques have allowed the experimental investigation of the nonlinear oscillatory dynamics of free droplets with diameter between 0.1 and 0.4 cm. The measurement of the resonance frequencies of the first three normal modes of large amplitude shape oscillations in an electric field of varying magnitude has been carried out with and without surface charges for weakly conducting liquids in air. These oscillations of nonspherical levitated drops have been driven by either modulating the ultrasonic field or by using a time-varying electric field, and the free decay from the oscillatory state has been recorded. A decrease in the resonance frequency of the driven fundamental quadrupole mode has been measured for increasing oblate deformation in the absence of an electric field. Similarly, a decrease in this frequency has also been found for increasing DC electric field magnitude. A soft nonlinearity exists in the amplitude dependence of the resonant mode frequencies for freely decaying as well as ultrasonically and electrically driven uncharged drops. This decrease in resonance frequency is accentuated by the presence of free surface charge on the drop. Subharmonic resonance excitation has been observed for drops in a time-varying electric field, and hysteresis exists for resonant modes driven to large amplitude. Mode coupling from lower-order resonances to higher-order modes has been found to be very weak, even for fairly large amplitude shape oscillations. Most of these results are in general agreement with predictions from recent analytical and numerical investigations.

Ultrasonically↗

A rheological mechanism of penetrative wear

A model is proposed which explains the penetrative wear of a soft material by a harder one. Three distinct modes of penetration are present depending on the applied load. During the most severe penetration plate-like wear debris is ejected at the leading edge of the slider. A series of slip line fields is presented to approximate this debris formation process. Plastic constraint is seen to be an important factor in wear particle formation.

Bates, T. R., Jr.↗

Ballistic Impact of Braided Composites with a Soft Projectile

Impact tests using a soft gelatin projectile were performed to identify failure modes that occur at high strain energy density during impact loading. Failure modes were identified for aluminum plates and for composites plates and half-rings made from triaxial carbon fiber braid having a 0/+/- 60deg architecture. For aluminum plates, a large hole formed as a result of crack propagation from the initiation site at the center of the plate. For composite plates, fiber tensile failure occurred in the back ply at the center of the plate. Cracks then propagated from this site along the +/-60deg fiber directions until triangular flaps opened to form a hole. For composite half-rings fabricated with 0deg fibers aligned circumferentially, fiber tensile failure also occurred in the back ply. Cracks first propagated from this site perpendicular the 0deg fibers. The cracks then turned to follow the +/-60deg fibers and 0deg fibers until rectangular flaps opened to form a hole. Damage in the composites was localized near the impact site, while cracks in the aluminum extended to the boundaries.

Roberts, Gary D.↗

Relation Between Magnetopause Position and Reconnection Rate Under Quasi‑Steady Solar Wind Dynamic Pressure

The lunar environment heliospheric X-ray imager (LEXI) and solar wind–magnetosphere–ionosphere link explorer (SMILE) will observe the magnetopause motion in soft X-rays to understand dayside reconnection modes as a function of solar wind conditions after their respective launches in the near future. To support their successful science mission, we investigate the relationship between the magnetopause position and the dayside reconnection rate by utilizing super dual auroral radar network (SuperDARN) observations and widely used empirical models of magnetopause position (Shue et al. in J Geophys Res 103:17691–17700. https://doi.org/10.1029/98JA01103, 1998 and Lin et al. in J Geophys Res 115:A04207. https://doi.org/10.1029/2009JA014235, 2010). We select three cases when the interplanetary magnetic field rotates during periods of quasi-steady solar wind dynamic pressure. We first estimate the dayside reconnection rate by calculating the electric field along the open–closed magnetic field boundary (OCB) in the OCB moving reference frame. Then, we estimate the magnetopause position near the local noon by inputting NASA OMNI solar wind data into the empirical magnetopause models. The reconnection rate shows anti-correlation with the magnetopause position that it generally increases as the magnetopause located closer to Earth and vice versa. Our result also confirms that the reconnection rate increases as the empirical coupling efficiency between solar wind and the magnetosphere increases.

Hyangpyo Kim↗

Facial Soft Tissue Measurement in Microgravity-induces Fluid Shifts

Fluid shifts are a well‐known phenomenon in microgravity, and one result is facial edema. Objective measurement of tissue thickness in a standardized location could provide a correlate with the severity of the fluid shift. Previous studies of forehead tissue thickness (TTf) suggest that when exposed to environments that cause fluid shifts, including hypergravity, head‐down tilt, and high‐altitude/lowpressure, TTf changes in a consistent and measurable fashion. However, the technique in past studies is not well described or standardized. The International Space Station (ISS) houses an ultrasound (US) system capable of accurate sub‐millimeter measurements of TTf. We undertook to measure TTf during long‐duration space flight using a new accurate, repeatable and transferable technique. Methods: In‐flight and post‐flight B‐mode ultrasound images of a single astronaut's facial soft tissues were obtained using a Vivid‐q US system with a 12L‐RS high‐frequency linear array probe (General Electric, USA). Strictly mid‐sagittal images were obtained involving the lower frontal bone, the nasofrontal angle, and the osseo‐cartilaginous junction below. Single images were chosen for comparison that contained identical views of the bony landmarks and identical acoustical interface between the probe and skin. Using Gingko CADx DICOM viewing software, soft tissue thickness was measured at a right angle to the most prominent point of the inferior frontal bone to the epidermis. Four independent thickness measurements were made. Conclusions: Forehead tissue thickness measurement by ultrasound in microgravity is feasible, and our data suggest a decrease in tissue thickness upon return from microgravity environment, which is likely related to the cessation of fluid shifts. Further study is warranted to standardize the technique with regard to the individual variability of the local anatomy in this area.

Marshburn, Thomas↗

RH1020 Single Event Clock Upset Summary Report

This report summarizes the testing and analysis of "single event clock upset' in the RH1020. Also included are SEU-rate predictions and design recommendations for risk analysis and reduction. The subject of "upsets" in the RH1020 is best understood by using a model consisting of a global clock buffer and a D-type flip-flop as the basic memory unit. The RH1020 is built on the ACT 1 family architecture. As such, it has one low-skew global clock buffer with a TTL-level input threshold that is accessed via a single dedicated pin. The clock signal is driven to full CMOS levels, buffered, and sent to individual row buffers with one buffer per channel. For low-skew performance, the outputs of all of the RH1020 row buffers are shorted together via metal lines, as is done in the A1020B. All storage in the RH1020 consists of routed flip-flops, constructed with multiplexors and feedback through the routing segments. A simple latch can be constructed from a single (combinatorial or C) module; an edge-triggered flip-flop is constructed using two concatenated latches. There is no storage in the I/O modules. The front end of the clock buffering circuitry, at a common point relative to the row buffer, is a sub-circuit that was determined to be the most susceptible to heavy ions. This is due, in part, to its smaller transistors compared to the rest of the circuitry. This conclusion is also supported by SPICE simulations and an analysis of the heavy ion data, described in this report. The edge triggered D flip-flop has two single-event-upset modes. Mode one, called C-module upset, is caused by a heavy ion striking the C-module's sensitive area on the silicon and produces a soft single bit error at the output of the flip-flop. Mode two, called clock upset, is caused by a heavy ion strike on the clock buffer, generating a runt pulse interpreted as a false clock signal and consequently producing errors at the flip-flop outputs. C-module upset sensitivity in the RH1020 is essentially the same as that of its ACT 1 siblings (A1020, A1020A and A1020B), which were well tested, analyzed, and documented in the literature.

Katz, Richard B.↗

Hologic QDR 2000 whole-body scans: a comparison of three combinations of scan modes and analysis software

This study reports on the short-term in vivo precision and absolute measurements of three combinations of whole-body scan modes and analysis software using a Hologic QDR 2000 dual-energy X-ray densitometer. A group of 21 normal, healthy volunteers (11 male and 10 female) were scanned six times, receiving one pencil-beam and one array whole-body scan on three occasions approximately 1 week apart. The following combinations of scan modes and analysis software were used: pencil-beam scans analyzed with Hologic's standard whole-body software (PB scans); the same pencil-beam analyzed with Hologic's newer "enhanced" software (EPB scans); and array scans analyzed with the enhanced software (EA scans). Precision values (% coefficient of variation, %CV) were calculated for whole-body and regional bone mineral content (BMC), bone mineral density (BMD), fat mass, lean mass, %fat and total mass. In general, there was no significant difference among the three scan types with respect to short-term precision of BMD and only slight differences in the precision of BMC. Precision of BMC and BMD for all three scan types was excellent: < 1% CV for whole-body values, with most regional values in the 1%-2% range. Pencil-beam scans demonstrated significantly better soft tissue precision than did array scans. Precision errors for whole-body lean mass were: 0.9% (PB), 1.1% (EPB) and 1.9% (EA). Precision errors for whole-body fat mass were: 1.7% (PB), 2.4% (EPB) and 5.6% (EA). EPB precision errors were slightly higher than PB precision errors for lean, fat and %fat measurements of all regions except the head, although these differences were significant only for the fat and % fat of the arms and legs. In addition EPB precision values exhibited greater individual variability than PB precision values. Finally, absolute values of bone and soft tissue were compared among the three combinations of scan and analysis modes. BMC, BMD, fat mass, %fat and lean mass were significantly different between PB scans and either of the EPB or EA scans. Differences were as large as 20%-25% for certain regional fat and BMD measurements. Additional work may be needed to examine the relative accuracy of the scan mode/software combinations and to identify reasons for the differences in soft tissue precision with the array whole-body scan mode.

NASA Discipline Musculoskeletal↗

An experimental and analytical investigation of isolated rotor flap-lag stability in forward flight

The flap-lag stability of an isolated hingeless rotor is investigated, both experimentally and analytically, in hover and in forward flight. The effects of forward flight aerodynamics on regressing lead-lag mode stability are the focus of the investigation. The soft-inplane, three-bladed, isolated model rotor was operated untrimmed at advance ratios from hover to 0.55 and at shaft angles as high as 20 deg. The experimental data base includes forward flight damping data for two lead-lag natural frequencies, for three values of collective pitch, and for both zero and full-lag structural coupling. With the aid of computerized symbolic manipulation, a rigid-blade lag-flap model analysis was developed to calculate the Floquent eigenvalues and to identify the modes. Good correlation is shown for some cases, but other cases show large discrepancies between the theory and experiment.

Gaonkar, Gopal H.↗

Decoupler pylon - A simple, effective wing/store flutter suppressor

As an alternative to alleviating wing/store flutter by conventional passive methods or by more advanced active control methods, a quasi-passive concept, referred to as the decoupler pylon, is investigated which combines desirable features of both methods. Passive soft-spring/damper elements are used to decouple wing modes from store pitch modes, and a low-power control system maintains store alignment under changing mean loads. It is shown by analysis and wind tunnel tests that the decoupler pylon provides substantial increase in flutter speed and makes flutter virtually insensitive to inertia and center-of-gravity location of the store.

Reed, W. H.↗