Search NASA⌕ Search

SEARCH · Search NASA

Results for “soiling chamber”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Microbiological characterization of a regenerative life support system

A Variable Pressure Plant Growth Chamber (VPGC), at the Johnson Space Center's (JSC) ground-based Regenerative Life Support Systems (RLSS) test bed, was used to produce crops of soil-grown lettuce. The crops and chamber were analyzed for microbiological diversity during lettuce growth and after harvest. Bacterial counts for the rhizosphere, spent nutrient medium, heat exchanger condensate, and atmosphere were approximately 1011 Colony Forming Units (CFU) g −1 , 105 CFU ml −1 , 105 CFU ml −1 , and 600 CFU m −3 , respectively. Pseudomonas was the predominant bacterial genus. Numbers of fungi were about 105 CFU g −1 in the rhizosphere, 4–200 CFU ml −1 in the spent nutrient medium, 110 CFU ml −1 in the heat exchanger condensate, and 3 CFU m −3 in the atmosphere. Fusarium and Trichoderma were the predominant fungal genera.

D W Koenig↗

BOREAS TGB-6 Soil Methane Oxidation and Production from NSA BP and Fen Sites

The BOReal Ecosystem-Atmosphere Study Trace Gas Biogeochemistry (BOREAS TGB-6) team collected soil methane measurements at several sites in the Southern Study Area (SSA) and Northern Study Area (NSA). This data set contains soil methane consumption (bacterial CH4 oxidation) and associated C-13 fractionation effects in samples that were collected at various sites in 1994 and 1996 from enclosures (chambers). Methane C-13 data in soil gas samples from the NSA Young Jack Pine (YJP) and Old Jack Pine (OJP) sites for 1994 and 1996 are also given. Additional data on the isotopic composition of methane (carbon and hydrogen isotopes) produced in the NSA beaver ponds and fen bog in 1993 and 1994 are given as well. The data are stored in tabular ASCII files.

Deck, Bruce↗

Argon content of the Martian atmosphere at the Viking 1 landing site - Analysis by X-ray fluorescence spectroscopy

Spectra provided by the Viking 1 X-ray fluorescence spectrometer operating in the calibration mode (without a soil sample in the analysis chamber) were analyzed to determine the argon content of the Martian atmosphere at the landing site. This was found to be less than or equal to 0.15 millibar, or not more than 2% by volume, consistent with data obtained by the entry mass spectrometer and by the mass spectrometer on the lander. It is anticipated that analysis of the K content of surface samples using X-ray fluorescence data will provide information on the evolution of the atmosphere, since most atmospheric argon is apparently produced by decay of K-40.

Clark, B. C.↗

Aspects of spatial and temporal aggregation in estimating regional carbon dioxide fluxes from temperate forest soils

We examine the influence of aggregation errors on developing estimates of regional soil-CO2 flux from temperate forests. We find daily soil-CO2 fluxes to be more sensitive to changes in soil temperatures (Q(sub 10) = 3.08) than air temperatures (Q(sub 10) = 1.99). The direct use of mean monthly air temperatures with a daily flux model underestimates regional fluxes by approximately 4%. Temporal aggregation error varies with spatial resolution. Overall, our calibrated modeling approach reduces spatial aggregation error by 9.3% and temporal aggregation error by 15.5%. After minimizing spatial and temporal aggregation errors, mature temperate forest soils are estimated to contribute 12.9 Pg C/yr to the atmosphere as carbon dioxide. Georeferenced model estimates agree well with annual soil-CO2 fluxes measured during chamber studies in mature temperate forest stands around the globe.

Kicklighter, David W.↗

Effect of Altered Gravity Environment on Tobacco Hornworm (Manduca Sexta) Development

Metamorphosis provides a unique condition for studying the role of gravity in development. Formation of new organs in a previously existing organism requires a highly active period of turnover of amino acids and proteins, and of changes in the endocrine profile. Furthermore, metamorphosis offers the advantage of studying a self-contained biological system. The tobacco hornworm provides a suitable species to study the effect of altered gravitational environment on invertebrate development. This species has been one of the most thoroughly investigated organisms in a variety of aspects of insect biology. M. sexta pharate adults can provide significant amounts of material with which to work, thus facilitating the study of metabolic aspects of adult development. During wandering, the period immediately following cessation of larval feeding, the larva burrows into the soil to form a pupation chamber. Despite burrowing down 25 to 30 cm, the insects reorient themselves to a slightly head-up (10 +/- 1 degree) position. Since light and temperature are not factors in this process, the larvae must sense the gravity vector. In our ground-based studies we had assessed whether developing adults might be sensitive to their gravitational environment by orienting pupae in a vertical head-up position within 24 to 48 h after pupal ecdysis. Our ground-based findings formed the foundation for determining which parameters would be evaluated in developing Manduca following spaceflight. Measurements were to include: (1) extent of development by all of the insects, (2) analysis of hemolymph obtained from half of the insects postflight for ecdysteroid, amino acid, urea, ammonia and trehalose concentrations, (3) further development of the other half of the insects to adult (moths), (4) analysis of the flight muscle protein content of the adults. Based on the first flight attempt in July, 1995, we modified the BRIC hardware to accommodate the insects. Our studies after BRIC-04 showed that sealing the top and bottom lids of the canisters with an 0-ring and with vacuum grease caused the insects to stop developing because of accumulation of carbon dioxide. Even though removing both the O-rings and vacuum grease permitted normal development, there was still some increase in carbon dioxide levels. Consequently, the canisters were vented and the vents covered with gas permeable membrane.

Tischler, Marc E.↗

The MSP 2001 Mars Environmental Compatibility Assessment (MECA)

The Mars Environmental Compatibility Assessment (MECA) will evaluate the Martian environment for soil and dust-related hazards to human exploration as part of the Mars Surveyor Program 2001 Lander. Sponsored by the Human Exploration and Development of Space (HEDS) enterprise, MECA's goal is to evaluate potential geochemical and environmental hazards that may confront future Martian explorers, and to guide HEDS scientists in the development of high fidelity Mars soil simulants. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatics of the soil and its environment, and arrays of material patches to study the abrasive and adhesive properties of soil grains. The instrument will acquire soil samples with a robotic arm equipped with a camera. MECA will examine surface and subsurface soil and dust in order to characterize particle size, shape, hardness, and also physical characteristics that may provide clues to mineralogy. MECA will characterize soil/water mixtures with respect to pH, redox potential, total dissolved ions, and trace toxins. MECA will determine the nature of electrostatic charging associated with excavation of soil, and the influence of ionizing radiation on material properties. It will also observe natural dust accumulation on engineering materials. To accomplish these objectives, MECA is allocated a mass of 10 kg within an enclosure of 35 x 25 x 15 cm. The Wet Chemistry Laboratory (WCL) consists of four identical cells that will accept samples from surface and subsurface regions accessible to the Lander's robotic arm, mix them with water, and perform extensive analysis of the solution. Ion-selective electrodes and related sensors will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases in wet Martian soil. These electrodes can detect potentially dangerous heavy-metal ions, emitted pathogenic gases, and the soil's corrosive potential. Experiments will include cyclic voltammetry and anodic stripping voltammetry. Complementary to the Viking experiments, the chemical laboratory will characterize the water-soil solution rather than emitted gases. Nonetheless, through analysis of dissolved gases it will be able to replicate many of the Viking observations related to oxidants. MECA's microscopy station combines optical and atomic-force microscopy (AFM) in an actively focused, controlled illumination environment to image particles from millimeters to nanometers in size. Careful selection of substrates allows controlled experiments in adhesion, abrasion, hardness, aggregation, magnetic and other properties. Special tools allow primitive manipulation (brushing and scraping) of samples. Soil particle properties including size, shape, color, hardness, adhesive potential (electrostatic and magnetic), will be determined using an array of sample receptacles and collection substrates. The simple, rugged atomic-force microscope will image in the submicron size range and has the capability of performing a particle-by-particle analysis of the dust and soil. On Earth, the earliest forms of life are preserved as microfossils. The atomic-force microscope will have the required resolution to image down to the scale of terrestrial microfossils and beyond. Mounted on the end of the robot arm, MECA's electrometer actually consists of four types of sensors: an electric field meter, several triboelectricity monitors, an ion gauge, and a thermometer. Tempered only by ultraviolet-light-induced ions and a low-voltage breakdown threshold, the dry, cold, dusty martian environment presents an imposing electrostatic hazard to both robots and humans. The field meter will measure the ambient field on nearby objects while the triboelectric sensors, using identical circuitry, will measure the charge accumulated on test substances as they are dragged through the soil by the arm. The ion chamber, open to the environment, will sense both charged dust and free ions in the air. Over and above the potential threat to electronics, the electrostatic environment holds one of the keys to transport of dust and, consequently, Martian meteorology. Viewed with the robot arm camera, the abrasion and adhesion plates are strategically placed to allow direct observation of the interaction between materials and soils on a macroscopic scale. Materials of graded hardness are placed directly under the robot arm scoop to sense wear and soil hardness. A second array, placed on the lander deck, is deployed after the dust plume of landing has settled. It can be manipulated in a primitive fashion by the arm, first having dirt deposited on it from the scoop and subsequently shaken clean. A third array will passively collect dust from the atmosphere. In addition to objectives related to human exploration, the MECA data set will be rich in information relevant to basic geology, paleoclimate, and exobiology issues. To understand both contemporaneous and ancient processes on Mars, the mineralogy, petrology, and reactivity of Martian surface materials should be constrained. The MECA experiment will shed light on these quantities through its combination of chemistry and microscopy. MECA will be capable of measuring the composition of ancient surface water environments, observing microscopic evidence of geological (and biological?) processes, inferring soil and dust transport, comminution and weathering mechanisms, and characterizing soil horizons that might be encountered during excavation.

Hecht, M. H.↗

Soil experiment

An experimental procedure was devised to investigate the effects of the lunar environment on the physical properties of simulated lunar soil. The test equipment and materials used consisted of a vacuum chamber, direct shear tester, static penetrometer, and fine grained basalt as the simulant. The vacuum chamber provides a medium for applying the environmental conditions to the soil experiment with the exception of gravity. The shear strength parameters are determined by the direct shear test. Strength parameters and the resistance of soil penetration by static loading will be investigated by the use of a static cone penetrometer. In order to conduct a soil experiment without going to the moon, a suitable lunar simulant must be selected. This simulant must resemble lunar soil in both composition and particle size. The soil that most resembles actual lunar soil is basalt. The soil parameters, as determined by the testing apparatus, will be used as design criteria for lunar soil engagement equipment.

Hutcheson, Linton↗

Understanding and modeling current and future coastal wetland methane dynamics (Final Report)

The coastal terrestrial-aquatic interface (TAI) is a highly dynamic component of the Earth system that plays a critical role in biogeochemical cycling. Due to its dynamic nature, the processes that regulate decomposition and methane (CH 4 ) emissions are of greater significance at the TAI than in upland systems. Despite this, we have limited mechanistic understanding of how climate stressors interact to regulate the electron acceptors and donors that determine decomposition pathways within TAIs, including the generation of hot spots and hot moments. Accurately modeling these processes is critical for incorporating the coastal TAI into Earth systems models, such as DOE’s E3SM. With previous DOE support, we adapted an aerobic terrestrial representation of decomposition using PFLOTRAN, a reactive flow and transport model, and added anerobic decomposition pathways, salinity, and oxygen (O 2 ) that fluctuates independently of water table level. However, because this model (PFLOTRAN TAI ) is based on decomposition rates and organic matter carbon to nitrogen ratios from terrestrial systems, its performance in TAI systems is currently limited by the lack of empirical data to properly parameterize variables. In addition, while PFLOTRAN TAI can simulate movement of O 2 into sediments, it is not currently capable of tracking the movement of CH 4 gas through plant tissues due to both current model structure and lack of available data. Our overall objective of the project was the increase our mechanistic understanding of CH 4 dynamics in response to environmental change, such that we can improve the representation of these dynamics in PFLOTRAN. We installed automated flux chambers in a new field-scale active soil warming experiment and set up marsh organs (mesocosms) to test effects of warming, flooding, and salinity. This resulted in a new dataset consisting of chamber-level CH 4 flux measurements across multiple sites, ecological conditions, and timeframes, as well as corresponding measurements on porewater chemistry, soil carbon quality, plant biomass, and redox reaction rates. Using these data, we improved PFLOTRAN TAI to more accurately model CH 4 dynamics and successfully tested our hypotheses. This grant contributed to the professional development of 3 postdocs, 4 undergraduate interns, 4 teacher interns, 17 technicians, and 15 participatory scientists. The automated chamber technology designed for this grant has also been shared with multiple new projects.

54 ENVIRONMENTAL SCIENCES↗

The search for life on Mars - Viking 1976 gas changes as indicators of biological activity

The objective of the gas exchange experiment (GEX) in the Viking lander biology instrument package is to determine whether life exists in a 1-cc Martian soil sample delivered to it. The GEX is capable of maximum flexibility while protecting the indigenous organisms from exposure to physiologically incompatible medium. The discussion covers the biological premises implemented in the GEX, the requirements for the GEX M4 medium, the operational aspects of the incubation chamber, nonbiological and biological changes, and Antarctica soil experiment. Sources of biological gas changes are examined along with ways of differentiating biological gas changes from nonbiological ones. From cold incubation of low-frequency soils, it is concluded that decisive negative tests of GEX may require extended incubations beyond the nominal mission plan of 60 days, barring any outright information that negates the presence of life on Mars.

Oyama, V. I.↗

Micro Acoustic Resonant Chambers for Heating/Agitating/Mixing (MARCHAM)

A variety of applications require the mixing and/or heating of a slurry made from a powder/fluid mixture. One of these applications, Sub Critical Water Extraction (SCWE), is a process where water and an environmental powder sample (sieved soil, drill cuttings, etc.) are heated in a sealed chamber to temperatures greater than 200 degrees Celsius by allowing the pressure to increase, but without reaching the critical point of water. At these temperatures, the ability of water to extract organics from solid particulate increases drastically. This paper describes the modeling and experimentation on the use of an acoustic resonant chamber which is part of an amino acid detection instrument called Astrobionibbler [Noell et al. 2014, 2015]. In this instrument we use acoustics to excite a fluid- solid fines mixture in different frequency/Amplitude regimes to accomplish a variety of sample processing tasks. Driving the acoustic resonant chamber at lower frequencies can create circulation patterns in the fluid and mixes the liquid and fines, while driving the chamber at higher frequencies one can agitate the fluid and powder and create a suspension. If one then drives the chamber at high amplitude at resonance heating of the slurry occurs. In the mixing and agitating cell the particle levitation force depends on the relative densities and compressibility’s of the particulate and fluid and on the kinetic and potential energy densities associated with the velocity and pressure fields [Glynne-Jones, Boltryk and Hill 2012] in the cell. When heating, the piezoelectric transducer and chamber is driven at high power in resonance where the solid/fines region is modelled as acoustic transmission line with a large loss component. In this regime, heat is pumped into the solution/fines mixture and rapidly heats the sample. We have modeled the piezoelectric transducer/chamber/ sample using Mason’s equivalent circuit. In order to assess the validity of the model we have built and tested a variety of chambers. This paper describes the experimental results which are in general agreement with theory within the limitations of the modeling.

fluid particle interaction↗

Description of concept and first feasibility test results of a life support subsystem of the Botany Facility based on water reclamation

The Botany Facility allows the growth of higher plants and fungi over a period of 6 months maximum. It is a payload planned for the second flight of the Eureca platform around 1990. Major tasks of the Life Support Subsystem (LSS) of the Botany Facility include the control of the pressure and composition of the atmosphere within the plant/fungi growth chambers, control of the temperature and humidity of the air and the regulation of the soil water content within specified limits. Previous studies have shown that various LSS concepts are feasible ranging from heavy, simple and cheap to light, complex and expensive solutions. A summary of those concepts is given. A new approach to accomplish control of the temperature and humidity of the air within the growth chambers based on water reclamation is discussed. This reclamation is achieved by condensation with a heat pump and capillary transport of the condensate back into the soil of the individual growth chamber. Some analytical estimates are given in order to obtain guidelines for circulation flow rates and to determine the specific power consumption.

Loeser, H. R.↗

Effect of Vacuum on Force Response of an Ultrasonic Penetrator

Introduction: The Apollo astronauts encountered higher than expected resistances when interacting with the lunar soil via the Apollo Lunar Surface Drill (ALSD) and the trenching tool. Reducing the force required to move tools or other mechanical components through regolith will impact many steps of the resource extraction process. Force reduction has been achieved in soil materials by imparting vibration to tooling interfaces such as a vibratory farming cultivator, a percussive scoop, and ultrasonically resonant penetrators. Vibration-assisted tools in granular media reduce interaction forces by fluidizing a volume around the tool, allowing the tool to progress through a dynamic (fluid) medium instead of a static (solid) medium. This work seeks to quantify ultrasonic vibration’s effect on the force response of a penetrator in lunar soil simulant in vacuum sufficient to be within the molecular flow regime of any disturbed gases. Methods: A custom vacuum chamber setup, CUBEvac, was designed and built to facilitate penetration testing in a high vacuum environment, for comparison to penetration behavior in ambient terrestrial environment. A two-stage pumping system (Agilent Triscroll 600 roughing pump, Agilent VHS-6 oil diffusion pump) reached chamber pressures of about 5x10-6 Torr with regolith simulant in place. Figure 1 is a schematic of the heart of the assembly (note the penetration drive mechanisms above the chamber feedthrough and the regolith simulant sample in the bottom are not shown). The penetration actuation stack was comprised of a stepper motor driving a lead screw to move the ultra-sonic probe vertically inside the chamber. Motion was coordinated with an Arduino Uno. GRC-3 lunar simulant was used for this set of experiments. Samples were prepared in a four-liter stain-less steel, cylindrical pot with an internal diameter of approximately 15.56 cm (6.125 in) and a depth of 19.37 cm (7 5/8 in) for testing. The soil was baked out prior to compaction preparation as a measure to reduce soil moisture which interfered with pump down capacity. The soil was not baked again if it was removed from the vacuum chamber, prepped, and immediately returned to the vacuum chamber for pump down. The soil was compacted using a 60 Hz vibration table with a surcharge of 34 kg place on top of the soil in the container. Prepared soil samples weighed approximately 6.5 kg (bulk density 1.895-1.934 g/cm3). Two probe end effectors were tested: A cone penetrometer (static only) with a nominal diameter of 12.7 mm (0.5 in) and a nominal height of 28.6 mm (1.125 in); and a vibrating cylindrical probe measuring 12.7 mm in diameter and 50.8 mm in effective length from the tip (Figure 2). The cylindrical probe vibrated resonantly at 20 kHz with an amplitude 23 μm. The cone penetration tests were conducted to assess potential soil behavior differences in vacuum. The cylinder probe tests were conducted as the primary subject of this investigation to assess force response in vacuum. For each test, a regolith simulant sample was load-ed and compacted in the chamber, which was then evacuated for roughly 18 hours to reach the lowest possible pressure (approximately 5x10-6 Torr for most tests). The probe was then moved to about 10 mm above the soil surface before being pushed to a depth of 50 mm for the cylinder probe tests and to a depth of 100 mm for the cone penetrometer tests, both at a speed of 2 mm/s. The simulant samples were prepared the same for all tests. Ideally, they would respond consistently to probe penetration under ambient and vacuum conditions. This was evaluated by measuring the resistance of representative prepared simulant beds with a standard cone penetrometer in both environments. Results and Discussion: The resistance of the simulant samples in the vacuum tests was consistently lower than in the ambient tests as determined by the cone penetration tests. Thus, the ambient and vacuum results cannot be compared directly; work is underway to de-confound and better correlate the data. Still, figures 3-6 show that probe penetration forces are lower overall in the vacuum environment. In both environments, resonant vibration of the probe provides two useful effects: It reduces the probe penetration force and smooths the force-depth curve, significantly reducing local maxima. These effects have implications for various potential applications, such as astronaut hand-tools, where benefits (reducing astronaut effort) outweigh the cost of the additional energy re-quired to generate vibration. These results demonstrate that resonantly vibrating tools can meaningfully reduce the penetration force required for excavation, probing, and drilling tools in simulated lunar regolith deposits under vacuum levels approaching those that will be experience on the Moon’s surface. Lunar-gravity, ambient environment tests are scheduled soon. The effects of realistic temperatures and temperature gradients and deeper vacuum remain to be tested.

E Rezich↗

Lunar Polar Environmental Testing: Regolith Simulant Conditioning

As ISRU system development approaches flight fidelity, there is a need to test hardware in relevant environments. Extensive laboratory and field testing have involved relevant soil (lunar regolith simulants), but the current design iterations necessitate relevant pressure and temperature conditions. Including significant quantities of lunar regolith simulant in a thermal vacuum chamber poses unique challenges. These include facility operational challenges (dust tolerant hardware) and difficulty maintaining a pre-prepared soil state during pump down (consolidation state, moisture retention).For ISRU purposes, the regolith at the lunar poles will be of most interest due to the elevated water content. To test at polar conditions, the regolith simulant must be doped with water to an appropriate percentage and then chilled to cryogenic temperatures while exposed to vacuum conditions. A 1m tall, 28cm diameter bin of simulant was developed for testing these simulant preparation and drilling operations. The bin itself was wrapped with liquid nitrogen cooling loops (100K) so that the simulant bed reached an average temperature of 140K at vacuum. Post-test sampling was used to determine desiccation of the bed due to vacuum exposure. Depth dependent moisture data is presented from frozen and thawed soil samples.Following simulant only evacuation tests, drill hardware was incorporated into the vacuum chamber to test auguring techniques in the frozen soil at thermal vacuum conditions. The focus of this testing was to produce cuttings piles for a newly developed spectrometer to evaluate. This instrument, which is part of the RESOLVE program science hardware, detects water signatures from surface regolith. The drill performance, behavior of simulant during drilling, and characteristics of the cuttings piles will be offered.

lunar regolith↗

Lunar Polar Environmental Testing: Regolith Simulant Conditioning

As ISRU system development approaches flight fidelity, there is a need to test hardware in relevant environments. Extensive laboratory and field testing have involved relevant soil (lunar regolith simulants), but the current design iterations necessitate relevant pressure and temperature conditions. Including significant quantities of lunar regolith simulant in a thermal vacuum chamber poses unique challenges. These include facility operational challenges (dust tolerant hardware) and difficulty maintaining a pre-prepared soil state during pump down (consolidation state, moisture retention).For ISRU purposes, the regolith at the lunar poles will be of most interest due to the elevated water content. To test at polar conditions, the regolith simulant must be doped with water to an appropriate percentage and then chilled to cryogenic temperatures while exposed to vacuum conditions. A 1m tall, 28cm diameter bin of simulant was developed for testing these simulant preparation and drilling operations. The bin itself was wrapped with liquid nitrogen cooling loops (100K) so that the simulant bed reached an average temperature of 140K at vacuum. Post-test sampling was used to determine desiccation of the bed due to vacuum exposure. Depth dependent moisture data is presented from frozen and thawed soil samples.Following simulant only evacuation tests, drill hardware was incorporated into the vacuum chamber to test auguring techniques in the frozen soil at thermal vacuum conditions. The focus of this testing was to produce cuttings piles for a newly developed spectrometer to evaluate. This instrument, which is part of the RESOLVE program science hardware, detects water signatures from surface regolith. The drill performance, behavior of simulant during drilling, and characteristics of the cuttings piles will be offered.

in situ resource utilization↗

Extraction and Capture of Water from Martian Regolith Experimental Proof-of-Concept

A novel concept for extraction of water from the Mars soil in a real-time, open-air process was demonstrated in a Mars environment chamber. The concept breadboard uses radiative heating to bake off water from exposed soil contained in a bin. An enclosure, intended to mimic the bottom of a rover, covers the bin. A fan continuously blows the Mars atmospheric gases through the enclosure to collect the evolved water while a tiller was used to churn up moist subsurface soil. These initial tests verified concept feasibility. The sweep gas generated by commercially available muffin fans at 7 Torr was sufficient to transfer water vapor into a condenser flow loop. The radiative heating, while non-optimized, heated the soil surface to 60 C to generate water vapor. A rototiller working through the soil bin brought sufficient amounts of new moist soil to the heated surface to show an increase in rate of water extraction.

Mars Exploration↗

Methane emission hotspots in a boreal forest-fen mosaic potentially linked to deep taliks

Permafrost thaw is transforming boreal forests into mosaics of wetlands and drier uplands. Topographic controls on hydrological and ecological conditions impact methane (CH 4 ) fluxes, contributing to uncertainty in local and regional CH 4 budgets and underlying drivers. The objective of this study was to explore CH 4 fluxes and their drivers in a transitioning boreal forest-fen ecosystem (Goldstream Valley, Alaska, USA). This landscape is characterized by thawing discontinuous permafrost and heterogeneous mosaics of fens, collapse-scar channels, and small mounds of permafrost soils. From a survey in July 2021, observed chamber CH4 fluxes included fen areas with intermediate to very high emissions (29.8–635.3 mg CH 4 m −2 d −1 ), clustered locations with CH 4 uptake (−2.11 to −0.7 mg CH 4 m −2 d −1 ), and three anomalous emission hotspots (342.4–772.4 mg CH 4 m −2 d −1 ) that were located near samples with lower emissions. Some surface and near-surface variables partially explained the spatial variation in CH 4 flux. Log-transformed CH 4 flux had a positive linear relationship with soil moisture at 20 cm depth ( R 2 = 0.31, p -value < 1e-5) and negative linear relationships with microtopography ( R 2 = 0.13, p -value < 0.006) and slope ( R 2 = 0.28, p -value < 2e-5). Methane emissions generally occurred in flat, wet, graminoid-dominated fens, whereas CH 4 uptake occurred on permafrost mounds dominated by feather mosses and woody vegetation. However, the CH 4 hotspots occurred on drier, slightly sloped locations with low or undetectable near-surface methanogen abundance, suggesting that CH 4 was produced in deeper soils. When the hotspot samples were omitted, log-transformed CH 4 flux had a positive linear relationship with near-surface methanogen abundance ( R 2 = 0.29, p -value = 0.0023), and stronger linear relationships with soil moisture, slope, and soil macronutrient concentrations. Our findings suggest that some CH 4 emission hotspots could arise from CH 4 in deep taliks. The inference that methanogenesis occurs in deep taliks was strengthened by the identification of intrapermafrost taliks across the study area using low-frequency geophysical induction. This study assesses surface spatial heterogeneity in the context of subsurface permafrost conditions and highlights the complexity of CH 4 flux patterns in transitioning forest-wetland ecosystems. To better inform regional CH 4 budgets, further research is needed to understand the spatial distribution of terrestrial CH 4 hotspots and to resolve their surface, near-surface, and subsurface drivers.

boreal↗

Preparation of a Frozen Regolith Simulant Bed for ISRU Component Testing in a Vacuum Chamber

In-Situ Resource Utilization (ISRU) systems and components have undergone extensive laboratory and field tests to expose hardware to relevant soil environments. The next step is to combine these soil environments with relevant pressure and temperature conditions. Previous testing has demonstrated how to incorporate large bins of unconsolidated lunar regolith into sufficiently sized vacuum chambers. In order to create appropriate depth dependent soil characteristics that are needed to test drilling operations for the lunar surface, the regolith simulant bed must by properly compacted and frozen. While small cryogenic simulant beds have been created for laboratory tests, this scale effort will allow testing of a full 1m drill which has been developed for a potential lunar prospector mission. Compacted bulk densities were measured at various moisture contents for GRC-3 and Chenobi regolith simulants. Vibrational compaction methods were compared with the previously used hammer compaction, or "Proctor", method. All testing was done per ASTM standard methods. A full 6.13 m3 simulant bed with 6 percent moisture by weight was prepared, compacted in layers, and frozen in a commercial freezer. Temperature and desiccation data was collected to determine logistics for preparation and transport of the simulant bed for thermal vacuum testing. Once in the vacuum facility, the simulant bed will be cryogenically frozen with liquid nitrogen. These cryogenic vacuum tests are underway, but results will not be included in this manuscript.

Klenhenz, Julie↗

ISRU Soil Mechanics Vacuum Facility: Soil Bin Preparation and Simulant Strength Characterization

Testing in relevant environments is key to exploration mission hardware development. This is true on both the component level (in early development) and system level (in late development stages). During ISRU missions the hardware will interface with the soil (digging, roving, etc) in a vacuum environment. A relevant test environment will therefore involve a vacuum chamber with a controlled, conditioned simulant bed. However, in earth-based granular media, such as lunar soil simulant, gases trapped within the material pore structures and water adsorbed to all particle surfaces will release when exposed to vacuum. Early vacuum testing has shown that this gas release can occur violently, which loosens and weakens the simulant, altering the consolidation state. The Vacuum Facility #13, a mid-size chamber (3.66m tall, 1.5m inner diameter) at the NASA Glenn Research Center has been modified to create a soil mechanics test facility. A 0.64m deep by 0.914m square metric ton bed of lunar simulant was placed under vacuum using a variety of pumping techniques. Both GRC-3 and LHT-3M simulant types have been used. An electric cone penetrometer was used to measure simulant strength properties at vacuum including: cohesion, friction angle, bulk density and shear modulus. Simulant disruptions, caused by off gassing, affected the strength properties, but could be mitigated by reducing pump rate. No disruptions were observed at pressures below 2.5Torr, regardless of the pump rate. However, slow off gassing of the soil lead to long test times, a full week, to reach 10-5Torr. This work highlights the need for robotic machine-simulant hardware and operations in vacuum to expeditiously perform (sub-)systems tests.

Kleinhenz, Julie↗