Search NASA⌕ Search

SEARCH · Search NASA

Results for “solar inverters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Open-air spray deposition of PCBM/BCP electron transport layer for inverted perovskite solar cells

A [6,6]-phenyl C61 butyric acid methyl ester (PCBM) and bathocuproine (BCP) electron transport layer (ETL) is spray deposited in open air directly on top of a perovskite at linear speeds of 9 m/min. The PCBM precursor ink contains a binary mixture of 1:1 chlorobenzene:chloroform, which optimizes spray wettability on the perovskite surface and allows quick solvent evaporation. A near-infrared heating module additionally provides a flash cure (<5 s) for the formation of smooth, large-area PCBM films (∼20 cm 2 ). A BCP solution in isopropanol is subsequently sprayed to form an ultrathin (<5 nm) film and characterized with a suite of high-resolution metrologies. The spray-deposition processing and near-infrared treatment do not damage the underlying perovskite. Inverted architecture devices containing the sprayed ETL achieve a champion efficiency of 20.3% and demonstrate stable performance without additional interlayers or surface treatments. Here, the technoeconomic cost of the open-air spray process is compared against traditional vacuum-based evaporation, resulting in a decrease in manufacturing costs by 26%.

14 SOLAR ENERGY↗

Large area deposition of low temperature processed SnO 2 as an ETL in inverted perovskite solar cell on flexible ITO-PET based substrate

Tin (IV) oxide (SnO 2 ) is a good electron transport material for perovskite photovoltaics high charge carrier mobility and superior stability Low temperature solution processability of SnO 2 low-cost fabrication lightweight and flexible perovskite solar cells on PET-based substrate Direct deposition of solution-processed SnO 2 on the top of perovskite is challenging solvent in compatibility with the perovskite materials To solve this problem, in this study we: synthesized SnO 2 nanoparticles functionalized them with acetate through ligand exchange allowing their dispersion in anhydrous ethanol

Chapagain, Sashil↗

High Performing Inverted Flexible Perovskite Solar Cells via Solution Phase Deposition of Yttrium-Doped SnO 2 Directly on Perovskite

Solution processing of flexible perovskite solar cells (f-PSCs) provides an avenue for scalable, high-throughput printing of lightweight, scalable, and cost-effective flexible solar cells. However, the deposition of fully solution-processed metal oxide charge transport layers on perovskites has been limited by solvent incompatibilities and high processing temperatures for metal oxide nanoparticles. In this study, we present high-performance, inverted f-PSCs from the direct deposition of yttrium doped SnO 2 nanoparticles functionalized with acetate on top of perovskite as an ink in anhydrous ethanol via blade coating. Yttrium doping improved device performance by improving the charge extraction leading with a decreased series resistance leading to improvements in the open-circuit voltage and fill factor. Furthermore, the champion power conversion efficiency for 0.1 cm 2 devices increased from 14.3% for undoped SnO 2 to 18.2% with 2% Y:SnO 2 doping, which is unprecedented for f-PSCs on ITO-PET substrate employing SnO 2 as an ETL.

14 SOLAR ENERGY↗

Flare heating and ionization of the low solar chromosphere. I - Inversion methods for Mg I 4571 and 5173

Various methods of inverting solar Mg I 4571 and 5173 spectral line observations are examined to find the best method of using these lines to calculate the vertical temperature and electron density structure around the temperature minimum region. Following a perturbation analysis by Mein (1971), a Fredholm integral equation of the first kind is obtained which can be inverted to yield these temperature and density structures as a function of time. Several inversion methods are tested and compared. The methods are used to test data as well as to a subset of observations of these absorption lines taken on February 3, 1986 before and during a solar flare. A small but significant increase is found in the temperature and a relatively large increase in the electron density during this flare. The observations are inconsistent with heating and ionization by an intense beam of electrons and with ionization by UV photoionization of Si I.

Metcalf, Thomas R.↗

Power generation forecasting for solar plants based on Dynamic Bayesian networks by fusing multi-source information

A Dynamic Bayesian network (DBN) model for solar power generation forecasting in solar plants is proposed in this paper. The key idea is to fuse sensor data, operational indicators, meteorological data, lagged output power information, and model errors for more accurate short-term (e.g., hours) and mid-term (e.g., days to weeks) power generation forecasting. The proposed DBN augments automated data-driven structure learning with expert knowledge encoding using continuous and categorical data given constraints to represent causal relationships within a solar inverter system. Additionally, an error compensation mechanism is proposed to capture temporal fluctuation. The effectiveness of the DBN on solar power generation forecasting was evaluated by rolling window analysis with one-year testing data collected from a local solar plant. The proposed DBN is compared with four state-of-art methods including support-vector regression (SVR), k-nearest neighbors (kNN), artificial neural network (ANN), and long short-term memory (LSTM) models. The result show that the proposed DBN achieves better accuracy in general, and it is not as data-hungry as some neural network-based models. The proposed DBN is also shown to have robust and consistent forecasting power with different forecasting horizons. The accuracy is 92% - 95% from one hour to one week ahead forecasting.

14 SOLAR ENERGY↗

Commercial PV Inverter IEEE 1547.1 Ride-Through Assessments Using an Automated PHIL Test Platform

As more countries seek solutions to their de-carbonization targets using renewable energy (RE) technologies, interconnection standards and national grid codes for distributed energy resources (DER) are being updated to support higher penetrations of RE and improve grid stability. Common grid-code revisions mandate DER devices, such as solar inverters and energy storage systems, ride-through (RT) voltage and frequency disturbances. This is necessary because as the percentage of generation from DER increases, there is a greater risk power system faults will cause many or all DER to trip, triggering a substantial load-generation imbalance and possible cascading blackout. This paper demonstrates for the first time a methodology to verify commercial DER devices are compliant to new voltage, frequency, and rate of change of frequency (ROCOF) RT requirements established in IEEE Std. 1547-2018. The methodology incorporates a software automation tool, called the SunSpec System Validation Platform (SVP), in combination with a hardware-in-the-loop (HIL) system to execute the IEEE Std. 1547.1-2020 RT test protocols. In this paper, the approach is validated with two commercial photovoltaic inverters, the test results are analyzed for compliance, and improvements to the test procedure are suggested.

14 SOLAR ENERGY↗

Modeling, testing, and mitigation of electromagnetic pulse on PV systems

Electromagnetic Pulse (EMP) poses a significant threat to the normal operation of power systems, especially with the increasing penetration of renewable energy. Without adequate protection, EMP can severely damage equipment or result in circuit breakdowns or short circuits. Solar photovoltaic (PV) facilities are particularly susceptible to EMP since PV systems are outdoors and exposed to EMP radiation. To assess and mitigate this threat, this paper summarizes various models and tests used to study the effects of EMP on PV systems, assesses the nature of the threat, and identifies measures to mitigate it. The paper provides a comprehensive review by categorizing analytical methods based on their pros and cons, introducing and describing EMP-related events, and providing a taxonomy of analytical methods for studying EMP. This paper compares the processes of modeling, testing, and mitigating EMP at both the component and system levels of PV systems. Furthermore, it also presents a case study that reveals the vulnerability of solar inverters to EMP using the pulse current injection method. Finally, the paper discusses some of the remaining challenges that should be considered in future solar PV system design and deployment.

14 SOLAR ENERGY↗

Advanced grid-forming (GFM) inverter controls, modeling and system impact study for inverter dominated grids

Our main goals in this project are to understand: 1) the stability of the power system with very high penetration of PV or other inverter-based resources (IBR), 2) the interactions among IBRs and traditional generators, and 3) the impact of the GFM inverters on bulk power system. To achieve these goals, we took a holistic research and development approach. First, an impedance-based large system modeling and stability analysis tool was developed to aid the large IBR system small-signal stability analysis. Second, consensus-based control and transient overload ride through were developed to control and coordinate multiple GFM inverters in a large system to maintain transient stability during big grid events. Third, high fidelity electromagnetic transient (EMT) IBR models were developed and integrated into a large reduced WECC model to study the system impact from IBRs. Lastly, extensive validation tests of the GFM control which was developed in this project and implemented in two 1MW commercial solar inverters were performed using different validation platforms, e.g., control hardware-in-the-loop (CHIL) platform, power hardware- in-the-loop (PHIL) platform, and a real PV plant.

14 SOLAR ENERGY↗

Multi-Port Autonomous Reconfigurable Solar Power Plant

As the penetration level of power electronics increases and remote photovoltaic (PV) generation is integrated into the alternating current (ac) grid, the short-circuit ratio (SCR) at the point of interconnection of a hybrid PV–energy storage system (ESS) plant may be low. Additionally, the inertia of the alternating current (ac) grid may be low. The low SCRs and inertias can lead to reliability challenges in the power grid. These operating conditions require additional reinforcements, such as synchronous condensers, static var compensators, static synchronous compensators, and high-voltage direct current (HVdc) links/grids. HVdc links or grids may also provide the additional capability of connecting the plant to asynchronous grids and/or connecting asynchronous grids, among others. This scenario leads to discrete development of solar inverters, energy storage inverters, HVdc converters, and several transformers. Some of the problems associated with this discrete development and inverter-based generation include increased cost, lower reliability, and reduced efficiency associated with duplication of power electronics (PEs); competing controls of several individual discrete inverter-based generators due to the presence of multiple PEs, which leads to derating of the system; and transient stability problems arising from inverter-based generation, such as voltage/frequency events leading inverter shutdowns, voltage instability and control interactions in the formed weak grid, and harmonics caused by resonances of multiple inverters.

14 SOLAR ENERGY↗

Why Wideband Gap Needs Techno-Economics

The wideband gap community when discussing projects antidotally refers to the cost of the technology, frequently noting the higher wideband gap upfront cost in comparison to the incumbent state of art. Other technologies such as photovoltaics have embraced techno-economics analysis (TEA) as a method of analytically articulating the impacts of research advancements on system performance and lifetime costs. Our TEA shows the potential impact of research advancements on Gallium Oxide (Ga2O3) and Silicon Carbide (SiC) wafer manufacturing cost, the impact on the levelized cost of electricity (LCOE) when using a SiC based solar inverter, and lastly how the high cost of devices (SiC in this case) can be offset by other system cuts, such as the footprint and cooling reductions in a 1MW variable frequency motor drive. The specific goal is to show analytically the lifetime cost and performance benefits of adopting wideband gap technology whether it is at the device level or it is cumulative benefit though a simplified balance of system.

14 SOLAR ENERGY↗

Sources of uncertainty in direct seismological measurements of the solar helium abundance

The methods by which Dappen et al. (1988, 1990, 1991) and Dziembowski et al. (1990, 1991, 1992) recently obtained discrepant estimates of the helium abundance in the solar convection zone are compared. The aim of the investigation reported in this paper is to identify the main source of the discrepancy. Using as proxy data eigenfrequencies of a set of modes of a theoretical solar model, computed with the same physics as were the frequencies of a reference model with which these data are compared, the two methods yield similar results. Thus we ascertain that the principal source of the discrepancy is not in the inversions themselves, which yield essentially a measure of the variation of the adiabatic exponent gamma of the material in the He II ionization zone. Instead it is in the approximations adopted in the treatment of heavy elements in the equation of state used to relate the variation of gamma to chemical composition. We obtain acceptably consistent results when inverting solar data by two methods using the same equation of state. We attempt to identify the likely residual sources of uncertainty.

Kosovichev, A. G.↗

Enhanced Control, Optimization, and Integration of Distributed Energy Applications (ECO-IDEA)

With support from the U.S. Department of Energy Solar Energy Technologies Office, the National Renewable Energy Laboratory (NREL) partnered with Xcel Energy, Schneider Electric, Varentec, and Electric Power Research Institute (EPRI) to meet the goals of the Enabling Extreme Real-Time Grid Integration of Solar Energy (ENERGISE) program. This project developed and validated an innovative data-enhanced hierarchical control architecture that enables the efficient, reliable, resilient, and secure operation of future distribution systems with a high penetration of distributed energy resources like solar energy. The architecture enables a hybrid control approach where a centralized control layer is complemented by distributed control algorithms for solar inverters and autonomous control of grid edge devices. It is fully interoperable and includes all the cybersecurity aspects necessary for reliable and secure system operation. The hybrid approach can seamlessly integrate multiple voltage-regulation technologies, both at central and grid-edge levels, which enables reliable and efficient system operation in the face of unpredictable conditions. The overarching goal of the Eco-Idea project is to develop, validate, and deploy a unique and innovative Data-Enhanced Hierarchical Control (DEHC) architecture that comprehensively addresses the formidable challenges associated with proliferation of high penetration of distributed PV such as reverse power flows, transients from variability of PV systems, feeder load balancing, and voltage stability. These issues are exposing the weaknesses of existing grid operations and controls - including, but not limited to, lack of grid situational awareness, heuristic and slow-acting control actions, latency of control for emergency situations, and points of failure in communications. The proposed architecture will comprehensively resolve the deficiencies of current operational settings - where monitoring and control solutions proposed across industry and academia may not be interoperable and may not coexist in the same system - and will enable an efficient, reliable, resilient, and secure operation of future distribution systems with penetration of solar energy well beyond current limits. The DEHC architecture was developed and validated rigorously through hardware-in-loop simulations in the laboratory environment and deployed on the field.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Spatial-Temporal PV Hosting Capacity Estimation and Evaluation

Evaluating Photovoltaic Hosting Capacity (PVHC) is an essential step in the process of integrating solar energy into power grids, particularly when focusing on the distribution network (DN) as the primary integration target. PVHC needs to be investigated, especially in cases where the grids are unbalanced, and their operational conditions vary spatially and temporally. This motivation prompted us to propose a scalable model tailored to this application. In this paper, we applied linearization to the alternating current optimal power flow (AC-OPF) and solar inverters, transforming the original problem into a mixed-integer linear programming (MILP) problem. Additionally, we accounted for the battery energy storage system (BESS) as a time-coupling factor for calculating PVHC. We then compared the PVHC results between the IEEE-13 bus and SMART-DS San Francisco (SFO) cases and discussed the extent to which BESS can enhance the PVHC of a DN. Furthermore, we designed a web-based graphical visualization for the SFO case, enabling user interaction with raw data and simulation results on a map through a graphical user interface (GUI). In summary, our results and findings provide valuable insights for future three-phase unbalanced AC-OPF PVHC practices and their visualization.

AC-optimal power flow↗

Distribution Feeder-Scale Fast Frequency Response via Optimal Coordination of Net-load Resources Part I: Solution Design

This work is the first of a two-part series that develops and experimentally demonstrates a first-of-its-kind hierarchical control solution for optimally dispatching thousands of deferrable loads and distributed energy resources (DERs) across a distribution feeder to provide fast frequency response (FFR) within 500 ms to the bulk power system. This approach rapidly coordinates resources online after a frequency event occurs, allowing fast-changing, behind-the-meter (BTM) resources to be incorporated and aggregate FFR power set points to be achieved more quickly and accurately than existing approaches. We also present a solution for determining the optimal amount of headroom to operate solar inverters with to minimize opportunity cost while ensuring the FFR response viability of a building with the inverter and deferrable loads. In Part I, we develop practical algorithms for fast, cost-based optimal dispatch at multiple aggregation scales (single building, multiple buildings, and full distribution feeder), establish their optimality, and demonstrate via simulation that they are faster than state-of-the-art, coordinated frequency response approaches. In Part II, the entire platform is implemented and experimentally verified using a unique power hardware-in-the-loop demonstration, including more than 100 powered loads and DERs connected to a real-world distribution network model and over 10,000 net-load resources dispatched.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distribution Feeder-Scale Fast Frequency Response via Optimal Coordination of Net-load Resources Part II: Large-Scale Demonstration

This work is the second of a two-part series in which we develop and experimentally demonstrate a hierarchical control solution for optimally coordinating thousands of deferrable loads and distributed energy resources (DERs) to provide fast frequency response (FFR) from an entire distribution feeder. In Part I, we developed and proved practical algorithms for fast, cost-based optimal dispatch and for determining the optimal amount of headroom to operate solar inverters with to support FFR dispatch while minimizing opportunity cost. Simulation results in Part I demonstrated the advantages of the hierarchical dispatch approach in being able to maintain fast solution times needed for FFR even when the problem size increases. In Part II, we implement the algorithms developed in Part I in a novel, large-scale power hardware-in-the-loop experiment including embedded controllers and more than 100 powered appliance loads and DER connected to a simulated real-world distribution system with more than 10,000 controlled devices. Experimental results from multiple scenarios confirm that the optimal FFR dispatch approach scales well and can optimally coordinate more than 10,000 net-load resources across a distribution network while achieving hardware response times within 500 ms, which is not possible using state-of-the-art optimal coordination approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗