Search NASA⌕ Search

SEARCH · Search NASA

Results for “solar stringing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Detection and Localization of Damaged Photovoltaic Cells and Modules Using Spread Spectrum Time Domain Reflectometry

The operating efficiency of photovoltaic (PV) plants can be improved if damaged or degraded modules can be detected and identified. Currently, string-level power electronics can detect problems with modules or cabling but not locate them, which would facilitate addressing these issues. Here, we investigate the ability of spread spectrum time domain reflectometry (SSTDR) to both detect and locate/identify damaged cells and modules within a series-connected PV string. We tested the ability of SSTDR to detect and locate single-cell mini-modules and full-sized PV modules, which were intentionally damaged by impacts with a hammer (breaking the glass and damaging the silicon below) or by cutting through some or all busbars. Damage to the glass and silicon of cells was detected and located within a small string of minimodules. Busbar damage was detectable only if an open was created by cutting through all intercell busbars. Furthermore, physical impact damage to the glass and silicon of a full-sized PV module could be detected, but further development of signal processing is needed to achieve localization of such damaged modules within a string.

14 SOLAR ENERGY↗

Feed-Forward Compensation for Model Predictive Control in Tri-port Current-Source Medium-Voltage String Inverters for PV-Plus-Storage Farms

The novel tri-port current-source medium-voltage string inverter (TCS-MVSI) is a promising candidate for large-scale PV-plus-storage (PVS) farms owing to its galvanic isolation, easy storage integration, soft-switching capability across entire load range, controlled low dv/dt and EMI, benign fault tolerance, etc. Due to its low inertia feature, traditional PI-based control cannot manage large transients effectively. Instead, a model-based predictive control (MPC) is proposed to achieve robust and stable operation. As is well known, the control performance of MPC is compromised by the sampling and computational delay during implementation significantly, if not well addressed. This paper analyzed and quantified these delays and then proposes feed-forward compensation (FFC) for the MPC method to compensate the delays and the large parameter variations due to the low-inertia nature. In addition, this method also compensates for the high dc-link ripple within each switching cycle, a unique issue for low-inertia converters. Here, the proposed method requires low computational effort, allowing it to be extended for multiple ports. The effectiveness of the proposed method has been validated in experiments. In 10 kW test, the proposed method decreases the average dc-link current by 17%, leading to ~20% conduction losses and ~0.5% increase in converter efficiency. In addition, the peak dc-link current also decreases by 15%, resulting in reduced transformer size. As a result, an increased power density can be achieved with the proposed method. Similar improvements have been observed across the power range from 2 kW to 10 kW.

30 DIRECT ENERGY CONVERSION↗

U.S. Solar Photovoltaic System and Energy Storage Cost Benchmark: Q1 2021 [Slides]

Our benchmarking method includes bottom-up accounting for all necessary system and projectdevelopment costs incurred when installing residential, commercial, and utility-scale systems, and it models the Q1 2021 costs for such systems, excluding any previous supply agreements or contracts. In general, we attempt to model the typical installation techniques and business operations from an installed-cost perspective, and our benchmarks are national averages. The residential PV-only benchmark and the commercial rooftop PV-only benchmark average costs by inverter type (string inverters, string inverters with direct current [DC] optimizers, and microinverters), weighted by inverter market share. The residential PV-only benchmark is further averaged across small installer and national integrator business models, weighted by market share. All benchmarks include variations—accounting for the differences in size, equipment, and operational use (particularly for storage)—that are currently available in the marketplace. All benchmarks assume nonunionized construction labor; residential and commercial PV systems predominantly use nonunionized labor, and the type of labor required for utility-scale PV systems depends heavily on the development process. All benchmarks assume the use of monofacial monocrystalline silicon PV modules. Benchmarks using cadmium telluride or bifacial modules could result in significantly different results. The data in this annual benchmark report inform the formulation of and track progress toward the U.S. Department of Energy (DOE) Solar Energy Technologies Office’s Government Performance and Reporting Act cost targets.

14 SOLAR ENERGY↗

Measurement of DC Arc-Flash Incident Energy in Large-Scale Photovoltaic Plants: A Basis for Standardization

The deployment of high-power dc equipment is increasing in solar photovoltaic (PV) plants, but very few studies have quantified dc arc-flash risks. Currently, PV plant owners and operators rely on theoretical, simplified models, such as those in NFPA-70E and other publications, for the assessment of risk associated with dc arc-flash. Here, this article presents an overview of arc-flash risks in a PV system based on a series of field experiments based on IEEE-1584 in two large-scale ground-mounted PV plants. The experiments include various high-power dc equipment of a PV plant, such as central inverters, combiner boxes, recombiner boxes, string inverters, and multiple configurations of electrodes in a 20-in calibration cube. The study reveals that none of the available dc arc-flash models are applicable for a PV plant. This work is an important first step toward developing an improved model that more accurately assesses dc arc-flash risk in a PV plant.

14 SOLAR ENERGY↗

Farm-level Interactions Study of a Novel Tri-port Soft-switching Medium-Voltage String Inverter (MVSI) based Large-scale PV-Plus-Storage Farms

A medium-voltage photovoltaic power conversion unit supported by battery based on a novel topology of soft switching solid state transformer is presented in this paper. It can reduce the Levelized Cost of Energy (LCOE) of PVS farm in an extended degree. However, its capability to provide grid-support services, such as frequency response, reactive power support, etc, have not been demonstrated. A series/parallel combination of these modules form a large 20 MVA solar farm. To validate them with reduced computation burden, a small-signal model of MVSI is firstly derived and validated in this paper. The model has been validated to match the full-switch model in both steady-state and dynamic conditions. Next, a farm-level simulation based on the proved small-signal model was implemented to demonstrate grid-support services. Real irradiation date from NREL is used to show the operational capabilities of the system. As a result, the overall farm is simulated based on MATLAB/Simulink domain to check the performance for various cases namely: power transfer from dc-ac side, reactive power support during grid voltage sag and utilization of battery during grid voltage disturbance or partial shading over PV panels.

14 SOLAR ENERGY↗

Failure analysis of field-failed bypass diodes

Defective bypass diodes are often found as the largest factor leading to power loss in solar modules. Here, we report on failure mechanisms by investigating shunted bypass diodes from a rooftop installation, using a combination of multiple characterizations including current–voltage analysis, thermal-runaway testing, X-ray computed tomography, lock-in thermography, focused ion-beam cross-section imaging, chemical decapsulation, optical microscopy, and scanning electron microscopy with energy-dispersive X-ray spectroscopy. Differing from static discharge typically associated with lightning strikes on modules, we found diode failure by the mechanism of thermal damage under continuous, long-term overstress in forward bias. Our conclusion is based on evidence of energy dissipated—the small to medium extent of melt-through on the Schottky diode face. The diode failure shows distortions or roughening of the Schottky diode metal-semiconductor interface with the die attach, and some failures are accompanied by die-attach solder melting. We propose that nonuniform irradiance on the modules caused diode shunting due to extended periods of heat dissipation in the modules, because modules in this string were placed in two different orientations. In contrast, a second parallel module string of the same module type on the same rooftop with a unique plane of array did not show any diode failures. The thermal damage failure of melt-through was caused by the long-term current generated by overstressing of diodes that may have had crystalline and impurity defects.

14 SOLAR ENERGY↗

Rapid Characterization and Statistical Analysis of High-Volume Field-Harvested Photovoltaic Connectors

Photovoltaic (PV) installations heavily depend on connectors for efficient module and string interconnections without requiring skilled labor. Yet this seemingly innocuous component of PV systems is a leading cause of module failures, multiple high-profile fires, and lawsuits in the PV industry. This work aims to answer critical questions regarding why connectors fail and the contributing factors to their failure. The study involves collecting and analyzing more than 17,000 field-harvested connectors from various solar installations across the United States. The vast dataset, which includes connector metadata, visual inspections, and resistance measurements, provides unprecedented insight into the state of health of PV connectors across the US, including the geographic locations, connector types, and installation practices most prone to failures. The work presented here describes a novel rapid characterization method for processing large numbers of connectors and is supported by parallel forensic analysis to discern the root causes of failures as well as a levelized cost of lifetime model to determine the economic ramifications of connector failure. Ultimately, the findings may inform PV developers about the best practices to extend connector longevity and lead to more resilient and reliable PV systems.

connectors↗

Hotspot testing of glass/backsheet and glass/glass PV modules pre-stressed in extended thermal cycling

This paper investigates the effect of hotspot (HS) stress endurance of two of the latest designs of monocrystalline modules: a half-cell glass/backsheet (G/B) module and a full-cell glass/glass (G/G) module. These modules have already been pre-stressed in extended thermal cycling with 600 cycles per the IEC 61215 standard to represent field-stressed modules. This study differs from the other conventional studies wherein only fresh modules are subjected to hotspot endurance stress. The G/G module reached a maximum temperature of approximately 200 °C at a cell shading of 25 %, 55 °C higher than the maximum hotspot temperature of 145 °C in the G/B module. A significant burn mark, without glass shattering, was observed in the hotspot-stressed cell of the G/G module due to the current mismatch induced by partial shading. Most of the cells in the G/G module appear to be severely damaged (severe dark areas), as observed in the electroluminescence (EL) image, while the dark regions were rarely present in the G/B module. The EL image also illustrates multiple cell cracks that resist current flow and eventually contribute to the full-cell module degradation. About 8.3 % degradation in maximum power was observed for the G/G module and 1.3 % for the G/B module after the sequential stress tests. The lower degradation in the G/B module can potentially be attributed to its design, which comprises of two parallel strings, each having 72-half-cells and benefits from lower heat dissipation. Furthermore, this indicates that the half-cell design could potentially minimize the hotspot degradation and failures in crystalline-silicon modules.

14 SOLAR ENERGY↗

Model of Operation-and-Maintenance Costs for Photovoltaic Systems

This article presents a method for calculating costs associated with operation and maintenance (O&M) of photovoltaic (PV) systems. It compiles details regarding the cost and frequency of multiple O&M services to estimate annual O&M costs ($\$$/year) for each year of an analysis period, the net present value ($\$$) of life cycle costs accumulated over the analysis period, and the reserve account amount ($\$$). Here we show that this method is an improvement over the previous averaged or levelized per-unit ($\$$/kW/year) valuations for estimating PV O&M costs, because it allows a detailed selection of services to perform based on system size, market served (e.g., residential, commercial, or utility), type and configuration of system components (e.g., micro-, string or central inverter) and site and environmental conditions (e.g., snow, pollen, bird populations). This model also distinguishes costs that vary from year to year and increase at different rates over time because of heuristic failure distributions (e.g. Weibull or Lognormal distribution) based on actuarial data for many of the services. This cost model was created by the PV O&M Working Group of researchers and industry, sponsored by DOE Solar Energy Technologies Office, and has been published in an on-line version hosted by SunSpec Alliance at apsuite.sunspec.org. A spreadsheet version is included with this paper as supplementary material.

14 SOLAR ENERGY↗

Rapid characterization and failure analysis of 6276 rooftop-harvested photovoltaic connectors

Photovoltaic (PV) connectors, which link modules in series and connect PV strings in parallel, have increasingly been recognized as a primary contributor to PV system failures and a source of numerous fire incidents. However, publicly available data on the rates and types of connector failures are scarce, primarily due to the proprietary nature of the information and the need for comprehensive analysis. This study represents the first large-scale investigation of harvested PV connectors, drawing from a dataset of 6276 connectors from residential rooftop solar systems across the United States. The outcome of this work is twofold: 1) we have established a rapid characterization method for large populations of harvested connectors, incorporating visual inspection, resistance measurements, and X-ray imaging; and 2) the analysis made possible by our rapid-processing method has revealed, for a population of connector models provided by a single rooftop installer, failure statistics and insights for various connector makes and models, installation practices, operating currents, and internal component displacements. This research identifies common failure modes that could be considered in future connector designs standards, and operations and maintenance practices, to ultimately improve the reliability of this vital component of PV infrastructure.

MC4↗

Field Experience Detecting PV Underperformance in Real Time Using Existing Instrumentation

Maintenance at large-scale photovoltaic plants employs a mix of preventative and corrective maintenance practices. Large outages, such as an inverter tripping offline, are often easy to detect. More subtle sub-inverter faults and failures can accumulate and go unnoticed for months or years. A software-based fault detection method has been developed to analyze commonly measured data from large-scale PV plants for more timely detection of subtle underperformance. The method has been demonstrated on eight datasets from large-scale plants with high accuracy of detection. Results are validated using aerial infrared scanning. String outages are detected with a true positive rate of 73 percent and tracker issues are detected with a true positive rate of 88 percent. The developed method can be uniformly applied to photovoltaic plants across a range of scales and configurations to assess performance, quickly detect underperformance, and determine the source and location of failures. The results inform and improve operations and maintenance at PV plants, ultimately aiding in improved affordability, reliability, availability, and resiliency of solar electricity.

14 SOLAR ENERGY↗

Dronebase Photovoltaic (PV) Fleet Imagery Quantitative Evaluation (CRADA CRD-22-22941 Final Report)

Combine the Dronebase aerial imagery with corresponding sites in the NLR Photovoltaic (PV) Fleets database. By combining these two data sources in an aggregated, anonymized fashion, we can perform the following analyses: quantifying power loss due to outages caused by stuck trackers, string outages, and shading/snow, validate site metadata, including tilt and azimuth, and correlate.

14 SOLAR ENERGY↗

Solar-Tracker Diffuse-Response Algorithm for Balancing Energy Gain and Mechanical Wear in Photovoltaic Systems

Single-axis solar tracking maximizes photovoltaic energy production under clear-sky conditions; however, its effectiveness decreases under cloudy and overcast skies, where diffuse irradiance dominates and the optimal module orientation changes. Conventional tracking algorithms either neglect sky conditions or rely on simplified diffuse-response strategies that may trigger frequent tracker repositioning under variable cloud cover, leading to increased mechanical wear with marginal energy gains. This work proposes an enhanced diffuse-response tracking algorithm that explicitly accounts for both the intensity and temporal persistence of cloudiness. By requiring overcast conditions to persist for a minimum duration before reorienting the tracker to a diffuse-stow position, the proposed approach reduces unnecessary movements while preserving the benefits of diffuse-response operation. The algorithm is evaluated through numerical simulations based on historical meteorological data and validated using field measurements on monofacial and bifacial photovoltaic strings. The results show that the proposed strategy reduces excess tracker movement from 114% to 0.16% while maintaining nearly the same energy yield. Compared to a conventional diffuse-response algorithm, the associated energy reduction is minimal (≈0.17%) relative to the ≈0.37% yield gain observed at the studied location. These findings demonstrate that incorporating cloudiness duration enables a practical compromise between energy performance and tracker durability, particularly for monofacial photovoltaic systems.

14 SOLAR ENERGY↗

Non-contact Current-Voltage (I-V) Tracer for Photovoltaics

This report presents a non-contact approach to simultaneously obtain current-voltage (I-V) curves of photovoltaic (PV) substrings and modules in a string without the need of disconnecting the individual modules from the string. There are two types of I-V curve tracers currently available in the marketplace, capacitor-based and electronic load-based. The primary requirement of these conventional I-V tracers is the disconnection of individual modules in the string so the individual modules contacted through the connectors of the individual modules. These contact-tracers have three major limitations in the utility scale power plants: First limitation – Weather and Accuracy: The mass-produced commercial contact-tracers cannot obtain the I-V curves of both string and its modules (as high as 30 modules), almost simultaneously (within about 5 minutes) at, practically, a single irradiance level, a single module temperature, a single spectrum and a single AOI (angle of incidence). This inability of the contact-tracers forces the testing personnel to wait for an extended or multiple sunny (>800 W/m 2 ) duration(s) of a cloudy day. This is a serious limitation as waiting for the sunny conditions or days is a huge practical challenge in almost all locations, except desert locations. Also, since the I-V curves are obtained at different prevailing weather conditions, it becomes critical to translate all the measured I-V curves of 30 modules in the string to a single test condition, for example STC (standard test conditions), so the underperforming modules can be identified. The accuracy of translation equations is heavily influenced by the irradiance level and temperature, spectral and AOI ranges; Second limitation - Safety: The second limitation is related to the high voltage electrical safety of the test personnel during disconnecting and reconnecting of individual modules or cable connectors from the string under daylight conditions and damaging of the original module connectors (especially the field aged connectors) during the disconnecting and reconnecting process; Third limitation – Labor: The third limitation is related to the enormous amount of time and hardship for the test personnel under prevailing (often harsh) protracted field conditions. This project was executed by Arizona State University in collaboration with its industry partner, PV Measurements Inc. (PVM). To mitigate all the three challenges of the state-of-the-art equipment indicated above, we utilized a non-contact I-V (NCIV) tracer approach. In this approach, we utilized an electrostatic voltmeter (ESV) and voltage sensor/probe combination to obtain I-V curves. The ESV units are extensively used in the high voltage industry but not in the PV industry. To obtain the simultaneous I-V curves of the substrings and modules within a string, we utilized multiple commercial ESV-Probe sets. In this approach, we utilized a non-contact voltage sensor (called, Probe) placed on the glass surface of the module (above the last cell of the module). This probe senses the module voltage (with respect to ground) through measured capacitance which is dictated by the surface charges (which in turn is dictated by the module voltage) and transmits the sensed voltage to the voltmeter (called, ESV or NCV, non-contact voltmeter). The current is sensed by a non-contact hall sensor. In a 30-module string, the 30th probe obtains the entire string I-V along with the string I-V obtained by the electronic load. so that the I-V curves of the substrings and modules can be obtained by NCIV without the need of disconnecting the individual modules in the string. The string I-V curves obtained by the electronic load and NCIV can be compared for the accuracy determination. One can use 30 ESV units and 30 Probes to obtain 30 I-V curves of a 30-module string or use just 5 ESV units and 30 Probes in conjunction with 5 six-channel switchboxes (called, 6:1 switchboxes). To reduce the equipment cost, we utilized the 6:1 switchbox approach so the number of ESV units is reduced from 30 to 5. The approaches, achievements and challenges of this project are detailed in this report.

14 SOLAR ENERGY↗

LCOE reduction through proactively optimized monitoring of PV Systems (Final Technical Report)

The project demonstrates the value proposition for a high-resolution monitoring system (HRMS) with diagnostic-prognostic capability and determine its impact on LCOE. The HRMS differs from conventional monitoring systems in a number of ways. First it will include the capability to automatically measure IV curves at the string and module levels. This provides a much richer view into the DC performance of the PV system and allows classification of many typical failure and degradation modes. Second, it will incorporate software capable of quantifying power and energy losses in the field as well as define the location and mechanism of the power and energy loss. Moreover, we aimed to deliver a prognostic system that is capable of predicting certain failures before they occur and giving system operators the opportunity to more efficiently plan operations and maintenance (O&M) activity in order to lower costs and increase yield over the life of the system. The research identifies cost targets required for different monitoring stages, including at the string combiner, at the individual string, and at the module level, to lower the levelized cost of energy (LCOE). Finally, a comprehensive guide determines the value PV monitoring brings to PV field operations. The guide assists plant operators in maximizing value from existing plants and identify the trade-offs of different monitoring solutions for future plants depending on the size, location, and expected system lifetime.

14 SOLAR ENERGY↗

A Comparative Analysis of Lithium-Ion Battery Chemistries for Cold-Climate Maritime Applications

Energy storage, primarily in the form of electrochemical batteries, is critical for enabling integration of marine energy (e.g., power from waves and currents) with end-use applications at sea due to the periodicity of the resources and requirement of consistent, smooth power delivery. Powering high-latitude coastal or ocean-based observing systems has been identified as a high value-proposition use case, exemplifying the concept of Powering the Blue Economy. An existing power system implementation for such a platform uses solar panels coupled to rechargeable lithium-ion batteries, augmented by a non-rechargeable backup bank used to power heaters in winter months. As wave energy is a potential resource for powering this and similar use cases and is strongest when solar power is most limited, it was hypothesized that integration of wave power would alleviate some of the challenges in cold climates related to energy storage. In this work, we investigate the use case scenario in simulation and perform a comparative test of commercially-available lithium-ion battery chemistry formulations to determine the most appropriate choice for the application. The experiment compared the most commonly-used lithium-based battery types (NCM, NCA, and LFP) in laboratory conditions emulating a battery enclosure thermally coupled to freezing seawater using an industrial battery performance tester in PNNL's arctic simulation lab. Battery strings were repeatedly cycled (i.e., charged, discharged, rested) and their usable capacity was measured. Both NCM and NCA strings exhibited degradation upon cycling, while the LFP string maintained stable operation through over 700 complete cycles. Though lower in baseline capacity, LFP are recommended for this and similar low-temperature applications with access to high levels of bulk charging current (e.g., from high-energy wave events) and their use may reduce the cost and complexity of battery conditioning and protection apparatus.

16 TIDAL AND WAVE POWER↗