Search NASA⌕ Search

SEARCH · Search NASA

Results for “sparse”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Small Genomes and Sparse Metabolisms of Sediment-Associated Bacteria from Four Candidate Phyla

Cultivation-independent surveys of microbial diversity have revealed many bacterial phyla that lack cultured representatives. These lineages, referred to as candidate phyla, have been detected across many environments. Here, we deeply sequenced microbial communities from acetate-stimulated aquifer sediment to recover the complete and essentially complete genomes of single representatives of the candidate phyla SR1, WWE3, TM7, and OD1. All four of these genomes are very small, 0.7 to 1.2 Mbp, and have large inventories of novel proteins. Additionally, all lack identifiable biosynthetic pathways for several key metabolites. The SR1 genome uses the UGA codon to encode glycine, and the same codon is very rare in the OD1 genome, suggesting that the OD1 organism could also transition to alternate coding. Interestingly, the relative abundance of the members of SR1 increased with the appearance of sulfide in groundwater, a pattern mirrored by a member of the phylum Tenericutes . All four genomes encode type IV pili, which may be involved in interorganism interaction. On the basis of these results and other recently published research, metabolic dependence on other organisms may be widely distributed across multiple bacterial candidate phyla. Few or no genomic sequences exist for members of the numerous bacterial phyla lacking cultivated representatives, making it difficult to assess their roles in the environment. This paper presents three complete and one essentially complete genomes of members of four candidate phyla, documents consistently small genome size, and predicts metabolic capabilities on the basis of gene content. These metagenomic analyses expand our view of a lifestyle apparently common across these candidate phyla.

59 BASIC BIOLOGICAL SCIENCES↗

CSBCOO SPMM: Compressed Sparse Block Coordinate format sparse matrix dense vector multiply benchmark (CSBCOO SPMM) v1.0

The purpose of this microbenchmark is to provide a means to explore different programming methodologies using a simple, but not trivial, mathematical kernel. The kernel is based on the matrix vector product in the MFDn nuclear configuration interaction code's LOBPCG eigensolver. This particular mathematical operation is a key element in the solution of systems of equations and block eigensolvers.

Cook, Brandon↗

Batched Sparse Linear Algebra (Final Report for Subcontract B648960)

This report finalizes design specifications for developing batched kernels for small tensor operations for unassembled matrix-free iterative solvers, batched solvers for partially assembled operators, and batched solvers with support for various sparse formats. The outcome of the project milestones is a set of interfaces to Batched Sparse LA solvers running on hardware accelerators for use in ECP Libraries and Applications. It is part of the development of sparse batched kernels, solvers/preconditioners as well as creating interoperability in xSDK libraries with sparse and dense batched functions to benefit ECP applications. The participants included representatives from ECP libraries (not limited to the xSDK project), applications, and vendors (AMD, Intel, and NVIDIA). Batched sparse linear algebra solvers form the new frontier for algorithmic development and performance engineering. Many applications (ECP and non-ECP alike) require simultaneous solutions of small linear systems of equations that are structurally sparse. To move towards high hardware utilization, it is important to provide these applications with appropriate interfaces to efficient batched sparse solvers running on modern hardware accelerators. We present interface designs in use by HPC software libraries supporting batched sparse linear algebra and the development of sparse batched kernel codes for solvers and preconditioners. We also address the potential interoperability opportunities to keep the software portable between the major hardware accelerators from AMD, Intel, and NVIDIA. The presented interface specifications includes batched band, sparse iterative, and sparse direct solvers. This report summarizes progress in Kokkos Kernels and the xSDK libraries MAGMA, Ginkgo, hypre, SUNDIALS, and SuperLU_dist.

97 MATHEMATICS AND COMPUTING↗

Sparse maps—A systematic infrastructure for reduced-scaling electronic structure methods. I. An efficient and simple linear scaling local MP2 method that uses an intermediate basis of pair natural orbitals

In this work, a systematic infrastructure is described that formalizes concepts implicit in previous work and greatly simplifies computer implementation of reduced-scaling electronic structure methods. The key concept is sparse representation of tensors using chains of sparse maps between two index sets. Sparse map representation can be viewed as a generalization of compressed sparse row, a common representation of a sparse matrix, to tensor data. By combining few elementary operations on sparse maps (inversion, chaining, intersection, etc.), complex algorithms can be developed, illustrated here by a linear-scaling transformation of three-center Coulomb integrals based on our compact code library that implements sparse maps and operations on them. The sparsity of the three-center integrals arises from spatial locality of the basis functions and domain density fitting approximation. A novel feature of our approach is the use of differential overlap integrals computed in linear-scaling fashion for screening products of basis functions. Finally, a robust linear scaling domain based local pair natural orbital second-order Möller-Plesset (DLPNO-MP2) method is described based on the sparse map infrastructure that only depends on a minimal number of cutoff parameters that can be systematically tightened to approach 100% of the canonical MP2 correlation energy. With default truncation thresholds, DLPNO-MP2 recovers more than 99.9% of the canonical resolution of the identity MP2 (RI-MP2) energy while still showing a very early crossover with respect to the computational effort. Based on extensive benchmark calculations, relative energies are reproduced with an error of typically <0.2 kcal/mol. The efficiency of the local MP2 (LMP2) method can be drastically improved by carrying out the LMP2 iterations in a basis of pair natural orbitals. While the present work focuses on local electron correlation, it is of much broader applicability to computation with sparse tensors in quantum chemistry and beyond.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Distributed-Memory Sparse Deep Neural Network Inference Using Global Arrays

Partitioned Global Address Space (PGAS) models exhibit tremendous promise in developing efficient and productive distributed-memory parallel applications. They have been used extensively in scientific computations due to conveniently offering a ``shared-memory''-like model and convenient interfaces that separate communication with synchronization. Traditionally, PGAS communication models have been applied to dense/contiguously distributed data, but most modern applications depict varied levels of sparsity. Existing PGAS models require certain adaptations to support distributed sparse computations, since associated computations often require matrix arithmetic, in addition to data movement. The Global Arrays toolkit from Pacific Northwest National Laboratory (PNNL) is one of the earliest PGAS models to combine one-sided data communication and distributed matrix operations and is still used in the popular NWChem quantum chemistry suite. Recently, we have expanded the Global Arrays toolkit to support common sparse operations, like sparse matrix-dense matrix multiplies (SpMM), sparse matrix-sparse matrix multiplication (SpGEMM) and Sampled Dense-Dense Matrix Multiplication (SDDMM). As it turns out, these operations are the bedrock of sparse Deep Learning (DL); sparse deep neural networks and Graph Neural Networks (GNNs) have gained increasing attention recently in achieving speedups on training and inference with reduced memory footprints. Unlike scientific applications in High Performance Computing (HPC), modern (distributed-memory capable) DL toolkits often rely on non-standardized and closed-source vendor software optimizations, creating challenges in software-hardware co-design at scale. Our goal is to support a variety of distributed-memory sparse matrix operations and helper functions in the newly created Sparse Global Arrays (SGA), such that it is possible to build portable and productive Machine Learning scenarios for algorithm/software and hardware codesign purposes. Contemporary data-parallel schemes for training/inference are undergoing a major overhaul since model replication limits scalability and causes resource inefficiencies. As such, we have adopted tensor parallelism in decomposing the model and inputs, to mitigate memory issues. Current implementation is built on top of MPI and uses CPUs to maximize the portability across the platforms.

Distributed computing, machine learning↗

Dose-shaping using targeted sparse optimization

Purpose: Dose volume histograms (DVHs) are common tools in radiation therapy treatment planning to characterize plan quality. As statistical metrics, DVHs provide a compact summary of the underlying plan at the cost of losing spatial information: the same or similar dose-volume histograms can arise from substantially different spatial dose maps. This is exactly the reason why physicians and physicists scrutinize dose maps even after they satisfy all DVH endpoints numerically. However, up to this point, little has been done to control spatial phenomena, such as the spatial distribution of hot spots, which has significant clinical implications. To this end, the authors propose a novel objective function that enables a more direct tradeoff between target coverage, organ-sparing, and planning target volume (PTV) homogeneity, and presents our findings from four prostate cases, a pancreas case, and a head-and-neck case to illustrate the advantages and general applicability of our method.Methods: In designing the energy minimization objective (E{sub tot}{sup sparse}), the authors utilized the following robust cost functions: (1) an asymmetric linear well function to allow differential penalties for underdose, relaxation of prescription dose, and overdose in the PTV; (2) a two-piece linear function to heavily penalize high dose and mildly penalize low and intermediate dose in organs-at risk (OARs); and (3) a total variation energy, i.e., the L{sub 1} norm applied to the first-order approximation of the dose gradient in the PTV. By minimizing a weighted sum of these robust costs, general conformity to dose prescription and dose-gradient prescription is achieved while encouraging prescription violations to follow a Laplace distribution. In contrast, conventional quadratic objectives are associated with a Gaussian distribution of violations, which is less forgiving to large violations of prescription than the Laplace distribution. As a result, the proposed objective E{sub tot}{sup sparse} improves tradeoff between planning goals by 'sacrificing' voxels that have already been violated to improve PTV coverage, PTV homogeneity, and/or OAR-sparing. In doing so, overall plan quality is increased since these large violations only arise if a net reduction in E{sub tot}{sup sparse} occurs as a result. For example, large violations to dose prescription in the PTV in E{sub tot}{sup sparse}-optimized plans will naturally localize to voxels in and around PTV-OAR overlaps where OAR-sparing may be increased without compromising target coverage. The authors compared the results of our method and the corresponding clinical plans using analyses of DVH plots, dose maps, and two quantitative metrics that quantify PTV homogeneity and overdose. These metrics do not penalize underdose since E{sub tot}{sup sparse}-optimized plans were planned such that their target coverage was similar or better than that of the clinical plans. Finally, plan deliverability was assessed with the 2D modulation index.Results: The proposed method was implemented using IBM's CPLEX optimization package (ILOG CPLEX, Sunnyvale, CA) and required 1-4 min to solve with a 12-core Intel i7 processor. In the testing procedure, the authors optimized for several points on the Pareto surface of four 7-field 6MV prostate cases that were optimized for different levels of PTV homogeneity and OAR-sparing. The generated results were compared against each other and the clinical plan by analyzing their DVH plots and dose maps. After developing intuition by planning the four prostate cases, which had relatively few tradeoffs, the authors applied our method to a 7-field 6 MV pancreas case and a 9-field 6MV head-and-neck case to test the potential impact of our method on more challenging cases. The authors found that our formulation: (1) provided excellent flexibility for balancing OAR-sparing with PTV homogeneity; and (2) permitted the dose planner more control over the evolution of the PTV's spatial dose distribution than conventional objective functions. In particular, E{sub tot}{sup sparse}-optimized plans for the pancreas case and head-and-neck case exhibited substantially improved sparing of the spinal cord and parotid glands, respectively, while maintaining or improving sparing for other OARs and markedly improving PTV homogeneity. Plan deliverability for E{sub tot}{sup sparse}-optimized plans was shown to be better than their associated clinical plans, according to the two-dimensional modulation index.Conclusions: These results suggest that our formulation may be used to improve dose-shaping and OAR-sparing for complicated disease sites, such as the pancreas or head and neck. Furthermore, our objective function and constraints are linear and constitute a linear program, which converges to the global minimum quickly, and can be easily implemented in treatment planning software. Thus, the authors expect fast translation of our method to the clinic where it may have a positive impact on plan quality for challenging disease sites.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effects of sparse sampling schemes on image quality in low-dose CT

Purpose: Various scanning methods and image reconstruction algorithms are actively investigated for low-dose computed tomography (CT) that can potentially reduce a health-risk related to radiation dose. Particularly, compressive-sensing (CS) based algorithms have been successfully developed for reconstructing images from sparsely sampled data. Although these algorithms have shown promises in low-dose CT, it has not been studied how sparse sampling schemes affect image quality in CS-based image reconstruction. In this work, the authors present several sparse-sampling schemes for low-dose CT, quantitatively analyze their data property, and compare effects of the sampling schemes on the image quality.Methods: Data properties of several sampling schemes are analyzed with respect to the CS-based image reconstruction using two measures: sampling density and data incoherence. The authors present five different sparse sampling schemes, and simulated those schemes to achieve a targeted dose reduction. Dose reduction factors of about 75% and 87.5%, compared to a conventional scan, were tested. A fully sampled circular cone-beam CT data set was used as a reference, and sparse sampling has been realized numerically based on the CBCT data.Results: It is found that both sampling density and data incoherence affect the image quality in the CS-based reconstruction. Among the sampling schemes the authors investigated, the sparse-view, many-view undersampling (MVUS)-fine, and MVUS-moving cases have shown promising results. These sampling schemes produced images with similar image quality compared to the reference image and their structure similarity index values were higher than 0.92 in the mouse head scan with 75% dose reduction.Conclusions: The authors found that in CS-based image reconstructions both sampling density and data incoherence affect the image quality, and suggest that a sampling scheme should be devised and optimized by use of these indicators. With this strategic approach, one can acquire optimally sampled sparse data so that the CS-based algorithms can best perform in terms of image quality.

61 RADIATION PROTECTION AND DOSIMETRY↗