Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectral range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Copernicus observations of the N v resonance doublet in 53 early-type stars

UV spectra in the wavelength interval 1170-1270 A are presented for 53 early-type stars ranging in spectral type from O6.5 V to B2.5 IV. The sample includes four Wolf-Rayet stars, seven known Oe-Be stars, and six galactic halo OB stars. A qualitative analysis of the stellar N v doublet reveals that: (1) N v is present in all stars hotter and more luminous than type B0 for the main sequence, B1 for giants, and B2 for supergiants; (2) shell components of N v and an unidentified absorption feature at 1230 A are present in about half of the stars; (3) the column density of N v is well correlated with bolometric luminosity over the spectral range O6 to B2; and (4) the ratio of emission to absorption equivalent width is a factor of 2 smaller in the main sequence stars than in supergiants, which suggests that the wind structure changes as a star evolves. For several stars, this ratio is too small to be explained by traditional wind models.

Abbott, D. C.↗

Exploring the Full Range of Properties of Quasar Spectral Distributions

The aim of this work is to support our ISO, far-infrared (IR) observing program of quasars and active galaxies. We have obtained, as far as possible, complete spectral energy distributions (radio-X-ray) of the ISO sample in order to fully delineate the continuum shapes and to allow detailed modelling of that continuum. This includes: ground-based optical, near-IR and mm data, the spectral ranges closest to the ISO data, within 1-2 years of the ISO observations themselves. ISO was launched in Nov 1995 and is currently observing routinely. It has an estimated lifetime is 2 years. All near-IR and optical imaging and spectroscopy are now in hand and in the process of being reduced, mm data collection and proposal writing continues.

Wilkes, B.↗

An Explorer-Class Astrobiology Mission

In this paper we describe a potential new Explorer-class space mission, the AstroBiology Explorer (ABE), consisting of a relatively modest dedicated space observatory having a 50 cm aperture primary mirror which is passively cooled to T less than 65 K, resides in a low-background orbit (heliocentric orbit at 1 AU, Earth drift-away), and is equipped with a suite of three moderate order (m approx. 10) dispersive spectrographs equipped with first-order cross-dispersers in an "echellette" configuration and large format (1024xl024 pixel) near- and mid-IR detector arrays cooled by a modest amount of cryogen. Such a system would be capable of addressing outstanding problems in Astrochemistry and Astrophysics that are particularly relevant to Astrobiology and addressable via astronomical observation. The observational program of this mission would make fundamental scientific progress in each of the key areas of the cosmic history of molecular carbon, the distribution and chemistry of organic compounds in the diffuse and dense interstellar media, and the evolution of ices and organic matter in young planetary systems. ABE could make fundamental progress in all of these areas by conducting an approximately one year mission to obtain a coordinated set of infrared spectroscopic observations over the 2.5-20 micrometers spectral range at spectral resolutions of R greater than or equal to 1000 of approximately 1000 galaxies, stars, planetary nebulae, and young star planetary systems.

Sandford, Scott↗

Exploring the Saturn System in the Thermal Infrared: The Composite Infrared Spectrometer

The Composite Inbred Spectrometer (CIRS) is a remote-sensing Fourier Transform Spectrometer on the Cassini orbiter that measures thermal radiation over two decades in wave number, from 10 to 1400 cm (1 mm to 7pm), with a spectral resolution that can be set from 0.5 to 20 cm. The far in portion of the spectrum (10 - 600 cm) is measured with a polarizing interferometer having thermopile detectors with a common 4-mrad field of view. The middle infrared portion is measured with a traditional Michelson interferometer having two focal planes (600 - 1100cm, 1100-1400 cm). Each focal plane is composed of a 1x10 array of HgCdTe detectors, each detector having a 0.3-mrad field of view. CIRS observations will provide three-dimensional maps of temperature, gas composition, and aerosols/condensates of the atmospheres of Titan and Saturn with good vertical and horizontal resolution, from deep in their tropospheres to high in their mesospheres. CIRS ability to observe atmospheres in the limb viewing mode (in addition to nadir) offers the opportunity to provide accurate and highly resolved vertical profiles of these atmospheric variables. The ability to observe with high-spectral resolution should facilitate the identification of new constituents. CIRS will also map the thermal and compositional properties of the surfaces of Saturn's icy satellites. It will similarly map Saturn's rings, characterizing their formation and evolution. The combination of broad spectral range, programmable spectral resolution, the small detector fields of view, and an orbiting spacecraft platform will allow CIRS to observe the Saturnian system in the thermal infrared at a level of detail not previously achieved.

Flasar, F. M.↗

Instrument Performance of Airs

AIRS, the Atmospheric Infrared Sounder on the Earth Observing System (EOS) PM spacecraft, is an infrared radiometer which covers the 3.7-15.4 micron spectral range with spectral resolving power better than 1000.

infrared spectrometer remote sensing Earth observi↗

Training and Validation of Spectral Gap Filling Algorithm for Cpf-Ceres Intercalibration

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder (CPF) mission is set to launch an SI-traceable reflective solar (RS) spectrometer aboard the International Space Station to measure Earth-reflected solar radiation with a radiometric uncertainty of 0.3% (k=1). The CPF intercalibration team has devised a cutting-edge methodology to accurately transfer the benchmark CPF calibration reference to the shortwave (SW) channel (200-5000 nm) of the Clouds and the Earth’s Radiant Energy System (CERES) instrument. The spectral range of CPF measurements spans from 350-2300 nm, while the CERES SW channel measures the Earth-reflected broadband solar radiances between 200 nm to 5 μm. To conduct precise CPF-CERES intercalibration analysis, the CPF-like spectral radiances outside the CPF spectral range need to be estimated to match the CERES SW spectral range. In response, the team has developed a fast algorithm that leverages spectrally redundant information within the CPF-measured portion through principal component analysis (PCA) and utilizes pre-established spectral correlation relationships among wavelengths to extend the CPF spectrum below 350 nm and above 2300 nm. Our results show that the algorithm achieves excellent accuracy in generating the missing energy in the UV and IR portions. The RMS error in the UV region is less than 4.5x10-3 W/m2/sr/nm, while in the IR region, it is smaller than 8x10-5 W/m2/sr/nm. Our methodology was validated using measured EMIT radiance data, which covers the spectral range from 0.381 μm to 2.493 μm. We employed EMIT radiances within the wavelength range of 0.43 – 2.25 μm to generate radiances for both the shorter wavelength range (0.381 – 0.43 μm) and longer wavelength range (2.25 – 2.493 μm). The generated radiances agree very well with the measured EMIT radiances. The standard deviation in the integrated broadband radiances was about 0.1%, and the bias is less than 0.004% for over 1.5 million EMIT measured samples. These statistics show that the spectral gap filling algorithm is robust and effective in substantially reducing the spectral difference-induced uncertainty in the CPF-CERES intercalibration samples.

Qiguang Yang↗

Multi-Spectral Solar Telescope Array

This paper descibes the design and the characteristics of the Multispectral Solar Telescope Array (MSSTA), a new rocket spectroheliograph to be launched in August 1990. The MSSTA includes five multilayer Ritchey-Chretien telescopes covering the spectral range 150-300 A and eight multilayer Herschelian telescopes covering the spectral range 40-1550 A, making it possible to obtain spectrohelipgrams over the soft X-ray/extreme UV/FUV spectral range. The MSSTA is expected to obtain information regarding the structure and dynamics of the solar atmosphere in the temperature range 10 to the 4th-10 to the 7th K.

Walker, Arthur B. C., Jr.↗

Multi-Color QWIP FPAs for Hyperspectral Thermal Emission Instruments

Infrared focal plane arrays (FPAs) covering broad mid- and long-IR spectral ranges are the central parts of the spectroscopic and imaging instruments in several Earth and planetary science missions. To be implemented in the space instrument these FPAs need to be large-format, uniform, reproducible, low-cost, low 1/f noise, and radiation hard. Quantum Well Infrared Photodetectors (QWIPs), which possess all needed characteristics, have a great potential for implementation in the space instruments. However a standard QWIP has only a relatively narrow spectral coverage. A multi-color QWIP, which is compromised of two or more detector stacks, can to be used to cover the broad spectral range of interest. We will discuss our recent work on development of multi-color QWIP for Hyperspectral Thermal Emission Spectrometer instruments. We developed QWIP compromising of two stacks centered at 9 and 10.5 ?m, and featuring 9 grating regions optimized to maximize the responsivity in the individual subbands across the 7.5-12 ?m spectral range. The demonstrated 1024x1024 QWIP FPA exhibited excellent performance with operability exceeding 99% and noise equivalent differential temperature of less than 15 mK across the entire 7.5-12 ?m spectral range.

Infrared focal plane arrays (FPAs)↗

Multi-color QWIP FPAs for hyperspectral thermal emission instruments

Infrared focal plane arrays (FPAs) covering broad mid- and long-IR spectral ranges are the central parts of the spectroscopic and imaging instruments in several Earth and planetary science missions. To be implemented in the space instrument these FPAs need to be large-format, uniform, reproducible, low-cost, low 1/f noise, and radiation hard. Quantum Well Infrared Photodetectors (QWIPs), which possess all needed characteristics, have a great potential for implementation in the space instruments. However a standard QWIP has only a relatively narrow spectral coverage. A multi-color QWIP, which is compromised of two or more detector stacks, can to be used to cover the broad spectral range of interest. We will discuss our recent work on development of multi-color QWIP for Hyperspectral Thermal Emission Spectrometer instruments. We developed QWIP compromising of two stacks centered at 9 and 10.5 μm, and featuring 9 grating regions optimized to maximize the responsivity in the individual subbands across the 7.5-12 μm spectral range. The demonstrated 1024x1024 QWIP FPA exhibited excellent performance with operability exceeding 99% and noise equivalent differential temperature of less than 15 mK across the entire 7.5-12 μm spectral range.

Gunapala, Sarath D.↗

Optical calibrator for TDL spectrometers

Two etalons and monochromator mode selector help calibrate spectrometer in selected laser mode. Technique accurately determines free spectral range of etalon. By establishing number of fringes between two modes, both of which have been calibrated with molecular line standards, one finds free spectral range with error inversely proportional to spectral interval between calibration points. Procedure establishes free spectral range of etalon without prior knowledge of its length or refractive index.

Jennings, D. E.↗

Spectral anomalies and broken symmetries in maximally chaotic quantum maps

Spectral statistics such as the level spacing statistics and spectral form factor (SFF) are widely expected to accurately identify “ergodicity,” including the presence of underlying macroscopic symmetries, in generic quantum systems ranging from quantized chaotic maps to interacting many-body systems. By studying various quantizations of maximally chaotic maps that break a discrete classical symmetry upon quantization, we demonstrate that this approach can be misleading and fail to detect macroscopic symmetries. Notably, the same classical map can exhibit signatures of different random matrix symmetry classes in short-range spectral statistics depending on the quantization. While the long-range spectral statistics encoded in the early time ramp of the SFF are more robust and correctly identify macroscopic symmetries in several common quantizations, we also demonstrate analytically and numerically that the presence of Berry-like phases in the quantization leads to spectral anomalies, which break this correspondence. Finally, we provide numerical evidence that long-range spectral rigidity remains directly correlated with ergodicity in the quantum dynamical sense of visiting a complete orthonormal basis.

Shou, Laura [Univ. of Maryland, College Park, MD (↗

Compact solar radiation simulator for the 400 to 1800 nm spectral region

A solar radiation simulator operating over the extended spectral range from 400 to 1800 nm is described. A source of Lambertian radiation over an extended spectral range similar to the extraterrestrial solar spectrum was required to test and calibrate the solar flux radiometer flown on the Pioneer-Venus mission. Available units did not feature the Lambertian target nor the extended spectral range. A source was designed and built using a tungsten-halogen lamp and a xenon arc, along with interference and absorption filters, and a BaSO4-coated integrating sphere. Readily available parts were used wherever possible. The spectral radiance of the test area and the calibration method are presented. The source can also be used with a quasi-collimated output beam of moderate uniformity.

Palmer, J. M.↗

GESE: A Small UV Space Telescope to Conduct a Large Spectroscopic Survey of Z-1 Galaxies

One of the key goals of NASA's astrophysics program is to answer the question: How did galaxies evolve into the spirals and elliptical galaxies that we see today? We describe a space mission concept called Galaxy Evolution Spectroscopic Explorer (GESE) to address this question by making a large spectroscopic survey of galaxies at a redshift, z is approximately 1 (look-back time of approximately 8 billion years). GESE is a 1.5-meter space telescope with an ultraviolet (UV) multi-object slit spectrograph that can obtain spectra of hundreds of galaxies per exposure. The spectrograph covers the spectral range, 0.2-0.4 micrometers at a spectral resolving power, R approximately 500. This observed spectral range corresponds to 0.1-0.2 micrometers as emitted by a galaxy at a redshift, z=1. The mission concept takes advantage of two new technological advances: (1) light-weighted, wide-field telescope mirrors, and (2) the Next- Generation MicroShutter Array (NG-MSA) to be used as a slit generator in the multi-object slit spectrograph.

galaxy evolution↗

Measurement of the dispersive and refractive indices of germanium using diode lasers

Germanium Fabry-Perot etalons are commonly used in diode laser spectroscopy to establish relative frequency calibration scales for molecular absorption spectra. Typically the channel spectrum of the etalon is recorded simultaneously with the molecular spectrum as the laser injection current is tuned linearly, and the etalon free spectral range (fringe spacing) is used to measure the frequency separations among lines in the molecular spectrum. For this purpose, the etalon free spectral range must be known for the measurement wavelength, and this in turn relies on knowledge of the etalon length and the dispersive index at this wavelength. It is pointed out that the most satisfactory approach is to measure directly the free spectral range or dispersive index of the etalon at the wavelength of interest. A description is presented of measurements of this type, performed near 7.9 and 10.1 micrometers for a 7.7-cm long germanium etalon.

Jennings, D. E.↗

Mineral Mapping with AVIRIS and EO-1 Hyperion

Imaging Spectrometry data or Hyperspectral Imagery (HSI) acquired using airborne systems have been used in the geologic community since the early 1980 s and represent a mature technology (Goetz et al., 1985; Kruse et al., 1999). The solar spectral range, 0.4 to 2.5 m, provides abundant information about many important Earth-surface minerals (Clark et al., 1990). In particular, the 2.0 to 2.5 m (SWIR) spectral range covers spectral features of hydroxyl-bearing minerals, sulfates, and carbonates common to many geologic units and hydrothermal alteration assemblages. Previous research has proven the ability of airborne and spaceborne hyperspectral systems to uniquely identify and map these and other minerals, even in sub-pixel abundances (Kruse and Lefkoff, 1993; Boardman and Kruse, 1994; Boardman et al., 1995; Kruse, et al., 1999). This paper describes a case history for a site in northern Death Valley, California and Nevada along with selected SNR calculations/results for other sites around the world. Various hyperspectral mineral mapping results for this site have previously been presented and published (Kruse, 1988; Kruse et al., 1993, 1999, 2001, 2002, 2003), however, this paper presents a condensed summary of key details for hyperspectral data from 2000 and 2001 and the results of accuracy assessment for satellite hyperspectral data compared to airborne hyperspectral data used as ground truth.

Kruse, Fred A.↗

Rocket-Plume Spectroscopy Simulation for Hydrocarbon-Fueled Rocket Engines

The UV-Vis spectroscopic system for plume diagnostics monitors rocket engine health by using several analytical tools developed at Stennis Space Center (SSC), including the rocket plume spectroscopy simulation code (RPSSC), to identify and quantify the alloys from the metallic elements observed in engine plumes. Because the hydrocarbon-fueled rocket engine is likely to contain C2, CO, CH, CN, and NO in addition to OH and H2O, the relevant electronic bands of these molecules in the spectral range of 300 to 850 nm in the RPSSC have been included. SSC incorporated several enhancements and modifications to the original line-by-line spectral simulation computer program implemented for plume spectral data analysis and quantification in 1994. These changes made the program applicable to the Space Shuttle Main Engine (SSME) and the Diagnostic Testbed Facility Thruster (DTFT) exhaust plume spectral data. Modifications included updating the molecular and spectral parameters for OH, adding spectral parameter input files optimized for the 10 elements of interest in the spectral range from 320 to 430 nm and linking the output to graphing and analysis packages. Additionally, the ability to handle the non-uniform wavelength interval at which the spectral computations are made was added. This allowed a precise superposition of wavelengths at which the spectral measurements have been made with the wavelengths at which the spectral computations are done by using the line-by-line (LBL) code. To account for hydrocarbon combustion products in the plume, which might interfere with detection and quantification of metallic elements in the spectral region of 300 to 850 nm, the spectroscopic code has been enhanced to include the carbon-based combustion species of C2, CO, and CH. In addition, CN and NO have spectral bands in 300 to 850 nm and, while these molecules are not direct products of hydrocarbon-oxygen combustion systems, they can show up if nitrogen or a nitrogen compound is present as an impurity in the propellants and/or these can form in the boundary layer as a result of interaction of the hot plume with the atmosphere during the ground testing of engines. Ten additional electronic band systems of these five molecules have been included into the code. A comprehensive literature search was conducted to obtain the most accurate values for the molecular and the spectral parameters, including Franck-Cordon factors and electronic transition moments for all ten band systems. For each elemental transition in the RPSSC, six spectral parameters - Doppler broadened line width at half-height, pressure-broadened line width at half-height, electronic multiplicity of the upper state, electronic term energy of the upper state, Einstein transition probability coefficient, and the atomic line center - are required. Input files have been created for ten elements of Ni, Fe, Cr, Co, Cu, Ca, Mn, Al, Ag, and Pd, which retain only relatively moderate to strong transitions in 300 to 430 nm spectral range for each element. The number of transitions in the input files is 68 for Ni; 148 for Fe; 6 for Cr; 87 for Co; 1 for Ca; 3 for Mn; 2 each for Cu, Al, and Ag; and 11 for Pd.

Tejwani, Gopal D.↗

Rapid measurement of soluble xylo-oligomers using near-infrared spectroscopy (NIRS) and multivariate statistics: calibration model development and practical approaches to model optimization

Rapid monitoring of biomass conversion processes using techniques such as near-infrared (NIR) spectroscopy can be substantially quicker and less labor-, resource-, and energy-intensive than conventional measurement techniques such as gas or liquid chromatography (GC or LC) due to the lack of solvents and preparation methods, as well as removing the need to transfer samples to an external lab for analytical evaluation. The purpose of this study was to determine the feasibility of rapid monitoring of a biomass conversion process using NIR spectroscopy combined with multivariate statistical modeling, and to examine the impact of (1) subsetting the samples in the original dataset by process location and (2) reducing the spectral range used in the calibration model on model performance. We develop multivariate calibration models for the concentrations of soluble xylo-oligosaccharides (XOS), monomeric xylose, and total solids at multiple points in a biomass conversion process which produces and then purifies XOS compounds from sugar cane bagasse. A single model using samples from multiple locations in the process stream showed acceptable performance as measured by standard statistical measures. However, compared to the single model, we show that separate models built by segregating the calibration samples according to process location show improved performance. We also show that combining an understanding of the sample spectra with simple multivariate analysis tools can result in a calibration model with a substantially smaller spectral range that provides essentially equal performance to the full-range model. We demonstrate that real-time monitoring of soluble xylo-oligosaccharides (XOS), monomeric xylose, and total solids concentration at multiple points in a process stream using NIR spectroscopy coupled with multivariate statistics is feasible. Segregation of sample populations by process location improves model performance. Models using a reduced spectral range containing the most relevant spectral signatures show very similar performance to the full-range model, reinforcing the importance of performing robust exploratory data analysis before beginning multivariate modeling.

09 BIOMASS FUELS↗