Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectral sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Surface-Enhanced Raman Spectroscopy Combined with Multivariate Analysis for Fingerprinting Clinically Similar Fibromyalgia and Long COVID Syndromes

Fibromyalgia (FM) is a chronic central sensitivity syndrome characterized by augmented pain processing at diffuse body sites and presents as a multimorbid clinical condition. Long COVID (LC) is a heterogenous clinical syndrome that affects 10–20% of individuals following COVID-19 infection. FM and LC share similarities with regard to the pain and other clinical symptoms experienced, thereby posing a challenge for accurate diagnosis. This research explores the feasibility of using surface-enhanced Raman spectroscopy (SERS) combined with soft independent modelling of class analogies (SIMCAs) to develop classification models differentiating LC and FM. Venous blood samples were collected using two supports, dried bloodspot cards (DBS, n = 48 FM and n = 46 LC) and volumetric absorptive micro-sampling tips (VAMS, n = 39 FM and n = 39 LC). A semi-permeable membrane (10 kDa) was used to extract low molecular fraction (LMF) from the blood samples, and Raman spectra were acquired using SERS with gold nanoparticles (AuNPs). Soft independent modelling of class analogy (SIMCA) models developed with spectral data of blood samples collected in VAMS tips showed superior performance with a validation performance of 100% accuracy, sensitivity, and specificity, achieving an excellent classification accuracy of 0.86 area under the curve (AUC). Amide groups, aromatic and acidic amino acids were responsible for the discrimination patterns among FM and LC syndromes, emphasizing the findings from our previous studies. Overall, our results demonstrate the ability of AuNP SERS to identify unique metabolites that can be potentially used as spectral biomarkers to differentiate FM and LC.

60 APPLIED LIFE SCIENCES↗

A New Method for Deriving Composition of S-type Asteroids from Noisy and Incomplete Near-infrared Spectra

The surface composition of S-type asteroids can be determined using band parameters extracted from their near-infrared (NIR) spectra (0.7–2.50 μm) along with spectral calibrations derived from laboratory samples. In the past, these empirical equations have been obtained by combining NIR spectra of meteorite samples with information about their composition and mineral abundance. For these equations to give accurate results, the characteristics of the laboratory spectra they are derived from should be similar to those of asteroid spectral data (i.e., similar signal-to-noise ratio (S/N) and wavelength range). Here we present new spectral calibrations that can be used to determine the mineral composition of ordinary chondrite-like S-type asteroids. Contrary to previous work, the S/N of the ordinary chondrite spectra used in this study has been decreased to recreate the S/N typically observed among asteroid spectra, allowing us to obtain more realistic results. In addition, the new equations have been derived for five wavelength ranges encompassed between 0.7 and 2.50 μm, making it possible to determine the composition of asteroids with incomplete data. The new spectral calibrations were tested using band parameters measured from the NIR spectrum of asteroid (25143) Itokawa, and comparing the results with laboratory measurements of the returned samples. We found that the spectrally derived olivine and pyroxene chemistry, which are given by the molar contents of fayalite (Fa) and ferrosilite (Fs), are in excellent agreement with the mean values measured from the samples (Fa{sub 28.6±1.1} and Fs{sub 23.1±2.2}), with a maximum difference of 0.6 mol% for Fa and 1.4 mol% for Fs.

79 ASTRONOMY AND ASTROPHYSICS↗

Hyperspectral imaging for real-time waste materials characterization and recovery using endmember extraction and abundance detection

Hyperspectral imaging, combined with advanced spectral unmixing techniques and artificial intelligence, offers a powerful solution for improving material identification and classification. Here, this study evaluates the effectiveness of the pixel purity index and the sequential maximum angle convex cone algorithms in extracting and validating spectral signatures from pure samples of paper components (cellulose and lignin) and plastic (polypropylene). Principal-component analysis showed that both algorithms captured nearly all relevant variance for the tested materials. Spectral signatures were compared using the spectral angle mapper, revealing high similarity in the short-wave infrared region and greater variability in the visible near-infrared range. The methodology was then applied to a disposable coffee cup to detect and quantify mixed materials, accurately estimating material abundance and object area with less than 1% error. This approach enhances material classification, supporting product verification, quality control, and automated sorting for sustainable waste management and resource recovery.

36 MATERIALS SCIENCE↗

Hyperfine structure and isotope shifts of xenon measured for near-infrared transitions with Doppler-free saturated absorption spectroscopy

Hyperfine structure and isotope shifts of Xe were investigated with Doppler-free saturated absorption spectroscopy for all transitions in the 820-841 nm spectral interval. The Xe samples were commercial gases of natural isotopic abundances. The measurements were performed by employing a widely tunable narrow line Ti:sapphire laser. The hyperfine structures for 129 Xe and 131 Xe were well resolved. For the transitions with the wavelengths in vacuum near 820.860 nm and 841.150 nm also isotope shifts of the even isotopes were clearly observed. The modeling of the shapes of the observed absorption lines qualitatively reproduces experimental spectral profiles. The measured absorption peaks of the hyperfine structure and isotope shifts of Xe isotopes present characteristic spectral fingerprints for their identification. Eventually, quantitative spectral analysis will provide isotopic abundances of natural, as well as radioactive Xe gas samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reagent-free Hyperspectral Diagnosis of SARS-CoV-2 Infection in Saliva Samples

Rapid, reagent-free pathogen-agnostic diagnostics that can be performed at the point of need are vital for preparedness against future outbreaks. Yet, many current strategies are pathogen-specific and require several reagents. We present hyperspectral sensing, using light to non-invasively measure the composition of several molecules to form a spectral signature, to overcome these barriers. To generate these spectral signatures, we present the ProSpectral TM V1, a novel, miniaturized hyperspectral platform with high spectral resolution with two mini-spectrometers. Furthermore, we developed state-of-the-art ML pipelines for near real-time analysis of spectral signatures in saliva samples. We found that we could accurately identify SARS-CoV-2 infection status in double-blinded saliva samples and demonstrate 100% accuracy on a hold out test dataset. To our knowledge, this establishes the fastest hyperspectral diagnostic platform and in a small form factor, and executable with liquid samples, without ligands or reagents, all while maintaining PCR level specificity and sensitivity.

59 BASIC BIOLOGICAL SCIENCES↗

Improving understanding of NpO 2 and Np 2 O 5 through vibrational spectroscopy

Raman spectra of three NpO 2 samples and two samples produced from a modified direct denitration (MDD) process were collected. The spectral features of the NpO 2 samples were consistent and indicated only NpO 2 . The spectra of the MDD samples indicated the presence of NpO 2 and an additional phase attributed to the neptunium binary oxide Np 2 O 5 . These Raman spectra are the first reported of Np 2 O 5 , and the proportions of these neptunium oxide phases varied within the samples, suggesting significant sample inhomogeneity. Peaks in the Raman spectra of Np 2 O 5 at 569 and 782 cm –1 were tentatively assigned to concerted, symmetric stretches of the neptunyl cations. Finally, laser-induced heating of regions in the MDD samples that were rich in Np 2 O 5 showed spectral features that indicated conversion to NpO 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tarda and Tagish Lake: Samples from the same outer Solar System asteroid and implications for D- and P-type asteroids

Here, we report a comprehensive study of the ungrouped type 2 carbonaceous chondrite, Tarda, which fell in Morocco in 2020. This meteorite exhibits substantial similarities to Tagish Lake, Wisconsin Range 91600, and Meteorite Hills 00432, which are generally considered to have originated from a D-type asteroid(s). We constrain the compositions and petrologies of the materials present in a potential sample of a D-type asteroid by reporting the petrography, bulk chemical compositions, bulk H, C, N, Cr, and Ti isotopic compositions, reflectance spectra, and in situ chemical compositions of metals, sulfides, carbonates, and FeO-poor and FeO-rich chondrule silicates of Tarda. We also present new data for Tagish Lake. We then compare Tarda with the other Tagish Lake-like meteorites. Tarda and Tagish Lake appear to be from the same parent body, as demonstrated by their similar petrologies (modal abundances, chondrule sizes), mineral compositions, bulk chemical and isotopic compositions, and reflectance spectra. While the two other Tagish Lake-like meteorites, Wisconsin Range 91600 and Meteorite Hills 00432, show some affinities to Tagish Lake and Tarda, they also share similar characteristics to the Mighei-like carbonaceous (CM) chondrites, warranting further study. Similarities in reflectance spectra suggest that P-type asteroids 65 Cybele and 76 Freia are potential parent bodies of Tarda and the Tagish Lake-like meteorites, or at least have similar surface materials. Since upcoming spacecraft missions will spectrally survey D-type, P-type, and C-type Trojan asteroids (NASA's Lucy) and spectrally study and return samples from Mars' moon Phobos (JAXA's Martian Moons eXploration mission), which is spectrally similar to D-type asteroids, these meteorites are of substantial scientific interest. Furthermore, since Tarda closely spectrally matches P-type asteroids (but compositionally matches the D-type asteroid like Tagish Lake meteorite), P-type and D-type asteroids may represent fragments of the same or similar parent bodies.

58 GEOSCIENCES↗

Investigation of defects in melt and solution grown perovskite CsPbBr 3 single crystals

Recently, there has been considerable interest in x-ray and gamma ray detectors with large volume and high energy resolution that operate at room temperature. To improve detector energy resolution, the carrier mobility-lifetime product needs to be increased, and the electronic trap state concentration needs to be minimized. Defect concentrations in the part per billion range can alter the charge transport and carrier recombination lifetime. In this work, thermally stimulated current spectroscopy measurements were systematically carried out in bulk halide perovskite single crystals of CsPbBr 3 over a temperature range of 80–320 K. The origins and trap parameters of CsPbBr 3 crystals from the solution growth and melt growth procedures were determined and compared. Trap concentrations were ranged from 1 × 10 11 to 1 × 10 16 cm –3 . Appreciable detector performance was observed for CsPbBr3 crystals with trap concentrations less than 1 × 10 14 cm –3 . The comparison of spectral responses of crystal samples grown using two different methods shows that, after purification, solution-grown crystals are comparable to melt-grown crystals in terms of low defect concentration and improved detector performance. Finally, for an improved mobility-lifetime product and enhanced spectral response to high energy radiation from fissile materials, trap states in either type of a crystal ingot must be reduced closer to 10 11 cm –3 .

36 MATERIALS SCIENCE↗

Correcting thermal-emission-induced detector saturation in infrared spectroscopy

We found that temperature-dependent infrared spectroscopy measurements (i.e., reflectance or transmittance) using a Fourier-transform spectrometer can have substantial errors, especially for elevated sample temperatures and collection using an objective lens. These errors can arise as a result of partial detector saturation due to thermal emission from the measured sample reaching the detector, resulting in nonphysical apparent reduction of reflectance or transmittance with increasing sample temperature. Here, we demonstrate that these temperature-dependent errors can be corrected by implementing several levels of optical attenuation that enable convergence testing of the measured reflectance or transmittance as the thermal-emission signal is reduced, or by applying correction factors that can be inferred by looking at the spectral regions where the sample is not expected to have a substantial temperature dependence.

47 OTHER INSTRUMENTATION↗

Diffuse X-ray scattering from polished silicon: application of the distorted wave Born approximation

Measured diffuse X-ray scattering data for a `smooth' as well as for a `rough' silicon sample were fit to theoretical expressions within the distorted wave Born approximation (DWBA). Data for the power spectral density (PSD) for both samples were also obtained by means of atomic force microscopy and optical interferometry. The Fourier transforms of trial correlation functions were fit to the PSD data and then applied to the DWBA formalism. The net correlation functions needed to fit the PSD data for each sample comprised the sum of two terms with different cutoff lengths and different self-affine fractal exponents. At zero distance these correlation functions added up to yield net values of σ 2 = (2) 2 and (71) 2 Å 2 for the smooth and rough samples, respectively. X-ray scattering data were obtained at beamline 1-BM of the Advanced Photon Source. Data and fits at values of q z = 0.05 and 0.10 Å −1 for the smooth sample are reported. Good fits for the smooth sample were obtained at both q z values simultaneously, that is, identical fitting parameters were applied at both values of q z . The smooth sample also exhibited weak Yoneda wings and a clear distinction between the strong specular scattering and the weak diffuse scattering. Data for the rough sample were qualitatively different and exhibited very weak scattering at the specular condition in contrast to extremely large Yoneda wings. Fits for the rough sample are reported for q z = 0.04, 0.05, and 0.06 Å −1 . Although the large Yoneda wings could be fit quite well in both position and amplitude, scattering near the specular condition could not be equally well fit by applying the same fitting parameters at all values of q z . Albeit imperfect, best-fitting results at the specular condition were obtained by invoking only diffuse scattering, that is, without including a separate theoretical expression for specular scattering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-resolution optical micro-spectroscopy extending from the near-infrared to the vacuum-ultraviolet

Optical characterization of small samples over a wide spectral range with rapid data acquisition is essential for the analysis of many material systems, such as 2D van der Waals layers and their heterostructures. In this paper, we present the design and implementation of a tabletop micro-spectroscopy system covering the near-infrared to the vacuum-ultraviolet (1.2 eV–6.8 eV or ~1.0 μm to 185 nm) using mostly off-the-shelf components. It can measure highly reproducible local reflectance spectra with a total integration time of a few minutes and a full-width-half-maximum spot size of 2.7 by 5.6 μm. For precise positioning, the design also allows simultaneous monitoring of the measurement location and the wide-field image of the sample. We demonstrate ultra-broadband reflectance spectra of exfoliated thin flakes of several wide-gap 2D materials, including ZnPS 3 , hexagonal BN, and Ca(OH) 2 .

47 OTHER INSTRUMENTATION↗

Acoustic Observations of the OSIRIS-REx Sample Return Capsule Re-Entry from Wendover Airport

The Origins, Spectral Interpretation, Resource Identification, and Security‐Regolith Explorer sample return capsule (SRC) re‐entered the Earth’s atmosphere at hypersonic speeds from interplanetary space on 24 September 2023. The current work reports on 18 ground‐based acoustic sensors deployed at Wendover Airport, the same location that the Genesis and Stardust SRC re‐entries were recorded. Four different sensors (Chaparral Physics, Gem, Wilson Engineering Research and Development [WERD], and RedVox) were deployed in close proximity to compare their performance. All the sensors captured an N‐wave signal associated with the SRC re‐entry shock wave followed by a broadband coda. The Chaparral Physics array served as the high‐fidelity reference measurement. The N‐wave signal had a peak‐to‐peak amplitude of 4.07 Pa with a fundamental frequency of 4.98 Hz from 167.5° measured clockwise from north, nearly perpendicular to the SRC trajectory. In addition, high coherence in the coda was shown to be associated reflections from the surrounding mountains. In general, the more economical sensors (Gem, WERD, and RedVox) produced results that were consistent with these observations and sensor specifications. Beamforming with these single sensors arranged as an array showed agreement with the high‐fidelity array to within a couple of degrees. Furthermore, the current high‐fidelity results were compared with the measurements during the Genesis and Stardust SRC re‐entries. All three entries produced a broadband fundamental peak at a frequency that was inversely related to the SRC diameter as well as evidence of reflections from the surrounding topography.

KC, Real J. [Oklahoma State University, Stillwater↗

Understanding the structural and morphological effects of synthesis route on NpO 2

The availability of actinide standard materials for use in nuclear safeguard applications is critical, as is thorough characterization thereof. Although accurate trace element compositions and isotopic considerations are paramount for deployment of reference standards, structural characterization is also essential towards accurately describing the chemical form and potential matrix effects in candidate materials. Here, to this end, samples of NpO 2 were synthesized via a direct denitration (DD) method and probed with powder X-ray diffraction (PXRD), Raman spectroscopy, and scanning electron microscopy (SEM) for structural and morphological characterization and comparison with NpO 2 materials produced via modified direct denitration (MDD). PXRD confirmed the bulk identity of NpO 2 , and no additional phases were identified using this method. Analysis of Raman data collected using a 532 nm excitation wavelength indicates that samples are mostly phase pure; however, some variability in spectral features is observed. Analysis of additional spectroscopic data collected with a 785 nm excitation wavelength revealed variability in the relative intensity of spectral features. Raman spectroscopy indicates that the sample is primarily NpO 2 ; however, additional signals indicate possible structural disorder, oxidized species, or potential contributions from other Np phases. To further investigate the possibility of additional phase contributions within the sample of NpO 2 , Raman spectroscopic mapping was employed to examine the homogeneity of the sample produced via DD. From this analysis, we determined that despite variability in the intensity of Raman-active vibrational modes, consistent spectra are obtained throughout the area of the sample investigated. SEM images show aggregates with variable sizes and shapes, with rounded, primary particles possessing an average diameter of approximately 100 nm. Comparison of the results of these multimodal analyses to the literature indicates that the crystal chemical, spectroscopic, and microstructural properties of NpO 2 vary based on synthesis method, even if X-ray diffraction data indicate that the bulk phase is NpO 2 .

Direct denitration↗

Pan-sharpening for microscopy

Techniques for generating full-spatial resolution, full spectral resolution image(s) from a 3D spectral-data cube for any spectral value within a given spectral range are provided without requiring the acquisition of all full-spatial resolution, full spectral resolution data by an instrument. The 3D spectral-data cube is generated from a limited number of full-spatial resolution, sparse spectral resolution data and a sparse-spatial resolution, full-spectral resolution data of the same area of the sample. The use of the 3D spectral-data cube reduces the data acquisition time.

Ovchinnikova, Olga S.↗

Autonomous Synthesis of Thin Film Materials with Pulsed Laser Deposition Enabled by In Situ Spectroscopy and Automation

Autonomous systems that combine synthesis, characterization, and artificial intelligence can greatly accelerate the discovery and optimization of materials, however platforms for growth of macroscale thin films by physical vapor deposition techniques have lagged far behind others. Here this study demonstrates autonomous synthesis by pulsed laser deposition (PLD), a highly versatile synthesis technique, in the growth of ultrathin WSe 2 films. Further, by combing the automation of PLD synthesis and in situ diagnostic feedback with a high-throughput methodology, this study demonstrates a workflow and platform which uses Gaussian process regression and Bayesian optimization to autonomously identify growth regimes for WSe 2 films based on Raman spectral criteria by efficiently sampling 0.25% of the chosen 4D parameter space. With throughputs at least 10x faster than traditional PLD workflows, this platform and workflow enables the accelerated discovery and autonomous optimization of the vast number of materials that can be synthesized by PLD.

36 MATERIALS SCIENCE↗

Spectroscopic and computational investigations of organometallic complexation of group 12 transition metals by methanobactins from Methylocystis sp. SB2

Methanotrophic bacteria catalyze the aerobic oxidation of methane to methanol using Cu-containing enzymes, thereby exerting a modulating influence on the global methane cycle. To facilitate the acquisition of Cu ions, some methanotrophic bacteria secrete small modified peptides known as “methanobactins,” which strongly bind Cu and function as an extracellular Cu recruitment relay, analogous to siderophores and Fe. In addition to Cu, methanobactins form complexes with other late transition metals, including the Group 12 transition metals Zn, Cd, and Hg, although the interplay among solution-phase configurations, metal interactions, and the spectroscopic signatures of methanobactin-metal complexes remains ambiguous. In this study, the complexation of Zn, Cd, and Hg by methanobactin from Methylocystis sp. strain SB2 was studied using a combination of absorbance, fluorescence, extended x-ray absorption fine structure (EXAFS) spectroscopy, and time-dependent density functional theory (TD-DFT) calculations. We report changes in sample absorbance and fluorescence spectral dynamics, which occur on a wide range of experimental timescales and characterize a clear stoichiometric complexation dependence. Mercury L3-edge EXAFS and TD-DFT calculations suggest a linear model for Hg--S coordination, and TD-DFT suggests a tetrahedral model for Zn 2+ and Cd 2+ . We observed an enhancement in the fluorescence of methanobactin upon interaction with transition metals and propose a mechanism of complexation-hindered isomerization drawing inspiration from the wild-type Green Fluorescent Protein active site. Collectively, our results represent the first combined computational and experimental spectroscopy study of methanobactins and shed new light on molecular interactions and dynamics that characterize complexes of methanobactins with Group 12 transition metals.

59 BASIC BIOLOGICAL SCIENCES↗

Upgrade of the helically symmetric experiment Thomson scattering diagnostic suite

The Helically Symmetric eXperiment (HSX) Thomson Scattering (TS) diagnostic is being upgraded to decrease uncertainty in electron temperature and density measurements. Upgrades to the HSX TS diagnostic will consist of a novel redesign of polychromator electronics and digitization of the TS output signal. Here, we also present a study of the benefits of an additional spectral channel that will sample the red-shifted band of the scattered spectrum. In conclusion, to maximize system bandwidth (BW) and gain, while minimizing noise, the existing low-BW polychromator electronics on HSX will be replaced by high-BW, high gain circuitry designed in-house.

47 OTHER INSTRUMENTATION↗

Independent Gamma Spectroscopy Analysis of a Plutonium Oxide Sample

Independent gamma spectroscopy data analysis of a plutonium oxide sample was requested on July 23, 2021. The primary request was to assess the Pu-239 activity/mass of the sample using previously collected gamma spectral data. Using the provided gamma spectral analysis report and spectral files, an independent evaluation of the data was conducted without any prior knowledge of the isotopic activity/mass of the sample.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗