Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectrometer chemical analysis instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

First-results from the Perseverance SHERLOC Investigation: Aqueous Alteration Processes and Implications for Organic Geochemistry in Jezero Crater, Mars

The Perseverance rover landed in Jezero crater, a site selected to fulfill the Mars-2020 mission goals of characterizing the geology of habitable environments and searching for signs of life while collecting samples for return to Earth [1]. Jezero hosted an open-basin lake during the late Noachian/early Hesperian (~3.7 Ga) [1-2], has units associated with the largest carbonate deposit identified on Mars [3-4], and has a well-preserved delta with clay and carbonate-bearing sediments, well-suited to preservation of organics [1,3-4]. Investigating the nature of organics and aqueous environments within their geologic con-text allows us to understand important aqueous processes and determine habitability within Jezero crater. Previous in situ landed measurements of organics could not resolve their spatial and mineralogical con-text [5-6]. Although Martian meteorites lack geological context, the spatial distribution of organic compounds in Martian meteorites have allowed recognition of an association between aqueous processes and organics [7-8]. Here, we show for the first time in-situ associations between carbonate-forming ultramafic alteration process, later stage aqueous sulfate and perchlorate formation, and organics on the Martian surface. Methodology and geological context: We use the Perseverance rover’s SHERLOC instrument (Scanning Habitable Environments with Raman and Lumines-ence of Organics and Chemicals), a deep-ultraviolet fluorescence and Raman scattering spectrometer capable of mapping the organic and mineral composition with a spatial resolution of 100 μm resolution to report the presence of organics and aqueously formed minerals at Jezero crater [9]. These spectral detections were compared with co-located images obtained with the autofocus context imager (ACI) and the WATSON camera for textural analysis [9]. As of writing, the Per-severance rover has abraded five targets that were measured with the SHERLOC instrument. The five targets are located in two different orbitally-identified geological units within the floor of Jezero crater; the Crater Floor Fractured Rough unit (CF-Fr) and the Séítah region within the Crater Floor Fractured 1 unit (CF-F1) [10]. In orbital infrared spectroscopic data, the CF-Fr unit is associated with pyroxene spectral signatures and minor alteration, while the Séítah region is associated with olivine and minor Mg-rich carbonates and clays [3-4,10]. Carbonation of ultramafic protolith recorded within Jezero crater: All scans of abraded targets within the Séítah region reveal strong peaks at 1080–1090 cm−1 consistent with carbonate and peak singlets or doublets at 820–840 cm−1 attributed to olivine (Fig. 1), consistent with orbital infrared observations. Our detailed micron-scale petrographic and spectroscopic evidence shows that these carbonates formed through carbonation of an ultramafic protolith. The supporting observations include: (1) Carbonate cation compositions match those of olivine, suggesting mixed Fe- and Mg-olivine gave rise to mixed Fe- and Mg-carbonates, similar to observations of ultramafic systems on Earth and within Martian meteorites [3-4,7-8]. (2) The ob-served carbonates co-occur with hydrated materials, gypsum, and potentially aqueously-formed phases, amorphous silicates and phosphate. (3) The spectral and textural variation of olivine and carbonate dominated zones and olivine-carbonate mixtures within both primary grains and interstitial zones are expected for carbonated ultramafic protoliths. (4) These mineral associations and textures closely resemble those observed within the ALH84001 and Nakhlite meteorites attributed to olivine carbonation on Mars [6-7]. Taken together, micron-scale SHERLOC documentation of these phenomena bridge previous orbital and meteorite observations and demonstrate in-situ regionally extensive (~106 km2) ultramafic alteration resulting in geo-logical deposition of carbonates. Furthermore, we observe that olivine carbonation was involved in preserving and possibly synthesizing organics, which makes this environment potentially habitable, as previously suggested in [1,3-4] (Fig. 1). Late-stage aqueous perchlorate and sulfate in Jezero crater: An abrasion target within the CF-Fr unit contains combinations of high intensity 950-955 cm−1 peaks and minor 1090-1095 cm−1 and 1150-1155 cm−1 peaks that are spectral fits to anhydrous perchlorate (Fig. 1). Some spectra show a combination of 950-955 cm−1 peaks with equally strong 1010-1020 cm−1 peaks, low intensity broad features at 1120 cm−1, and occasional broad 3450 cm−1 hydration (-OH) features, indicating a mixture of Ca-sulfate and perchlorate that is minimally hydrated (Fig. 1). The detections of per-chlorates within Jezero crater differ from previous measurements (e.g. Phoenix lander, Curiosity rover, Tissint meteorite [7,11]) because they are observed to be intimately related to aqueous processes including sulfate formation, they present as a secondary white void-fill occurring within the interior of the rock, and they are found to likely be Na-perchlorate. implications for their formation: Three different types of organics embedded within three different lithologies were observed within the abraded targets. Organics associated with low intensity ~340 nm fluorescence were widespread within targets with no apparent association to particular minerals (Fig. 1). Organics associated with ~305 nm and ~275 nm fluorescence correlated with sulfates within the Bellegarde target in the CF-Fr unit, while organics associated with high intensity ~340 nm fluorescence correlated with carbonate, phosphate, and amorphous silicate mixtures within the Garde target in the Séítah region (Fig. 1). Although assignment of fluorescence signatures to specific organic compounds is not conclusive, ~340 nm fluorescence is generally more consistent with 2-ring aromatic organics, ~275 nm fluorescence is more consistent with 1-ring aromatic organics, and ~305 nm fluorescence can be created by either 2- or 1-ring aromatics [12]. These observations indicate that the strongest fluorescence signatures interpreted as organics were found in materials associated with aqueous processes, i.e. sulfate- and carbonate-bearing materials, suggesting both brines and ultramafic carbonation aqueous environments were capable of preserving organics on ancient Mars. In Martian meteorites, simple aromatic organics proposed to have been synthesized through aqueous processes can be found within minerals associated with olivine carbonation and in spatial association with perchlorate and sulfate materials [7-8], similar to SHERLOC observations. Hence, we advance an abiotic aqueous synthesis origin for the organics although we cannot rule out the presence of organics from meteoritic in-fall or putative organic biosignatures. Detailed analyses will be required upon return of these materials to Earth.

E L Scheller↗

Electron spectroscopy for chemical analysis: Sample analysis

Exposure conditions in atomic oxygen (ESCA) was performed on an SSL-100/206 Small Spot Spectrometer. All data were taken with the use of a low voltage electron flood gun and a charge neutralization screen to minimize charging effects on the data. The X-ray spot size and electron flood gun voltage used are recorded on the individual spectra as are the instrumental resolutions. Two types of spectra were obtained for each specimen: (1) general surveys, and (2) high resolution spectra. The two types of data reduction performed are: (1) semiquantitative compositional analysis, and (2) peak fitting. The materials analyzed are: (1) kapton 4, 5, and 6, (2) HDPE 19, 20, and 21, and (3) PVDF 4, 5, and 6.

Carter, W. B.↗

Extraterrestrial Molecular Indicators of Life Investigation (EMILI)

Future missions to Enceladus, Europa, Mars, and beyond may seek the molecular signs of extraterrestrial life through chemical analysis of acquired samples. Particularly on ocean worlds such as Enceladus and Europa, samples may contain trace ocean-borne molecular biosignatures of extant life that may or may not share similarities to those of terrestrial life. In situ analyses must be prepared to detect and characterize a wide range of possible molecular species, structures, and patterns, typically with exquisite sensitivity and within a complex, poorly-characterized planetary environment. The Extraterrestrial Molecular Indicators of Life Investigation (EMILI) is designed to meet or exceed the requirements of such missions for organic molecular analysis through a powerful combination of dual chemical separation and both optical and mass spectrometry detection techniques, realized in an integrated, compact instrument package fully compatible with anticipated flight resources and conditions. The full EMILI instrument combines two sample analysis subsystems to provide wide-ranging and complementary detection of organic compounds and inorganic salts. The Gas Analysis Processing System (GAPS) uses a chemical derivatization protocol with gas chromatography (GC) separation prior to detection in an ion trap mass spectrometer (ITMS) to enable full characterization of lower-polarity, volatile and semi-volatile molecules such as fatty acids and hydrocarbons. The Organic Capillary Electrophoresis ANalysis System (OCEANS) uses a liquid-based extraction protocol with CE separation to enable precise analysis of more water-soluble/polar compounds. OCEANS features a laser-induced fluorescence detection mode to perform ultra-sensitive quantitative analysis of chiral amino acids. In EMILI, OCEANS is additionally coupled to the same ITMS through a novel electrospray ionization interface. The common ITMS allows EMILI to identify and cross-correlate molecular species and patterns, detected through either or both protocols, of molecular weights to over 1000 u, potentially even revealing complex biosignatures such as alien oligopeptides and informational polymers.

Europa↗

Titan Ice and Dust Experiment (TIDE): Detection and Analysis of Compounds of Interest to Astrobiology in the Lower Atmosphere and Surface of Titan

The Titan Orbiter Aerorover Mission (TOAM) is a proposed concept for the Solar System Exploration Visions Mission, Titan Explorer, a follow-on to the Cassini-Huygens mission. TOAM would use a Titan polar orbiter and a lighter-than-air aerorover to investigate the surface and atmosphere of Titan. Astrobiology issues will be addressed though TOAM investigations including, for example: Distribution and composition of organics (atmospheric, aerosol, surface); Organic chemical processes, their chemical context and energy sources; and Seasonal variations and interactions of the atmosphere and surface. The TIDE instrument will perform in-situ analyses to obtain comprehensive and sensitive molecular and elemental assays of volatile organics in the atmosphere, oceans and surface. TIDE chemical analyses are conducted by a Gas Chromatograph-Ion Mobility Spectrometer (GC-IMS). This TIDE GC-IMS was a component of the mini-Cometary Ice and Dust Experiment (mini-CIDEX) developed for the chemical analysis of a cometary environment. Both the GC and helium IMS of mini-CIDEX have been further developed to better meet the analytical and operational requirements of the TOAM. application. A Micro-ElectroMechanical System (MEMS) GC and Mini-Cell helium IMS are under development to replace their respective mini-CIDEX components, providing similar or advanced analytical capabilities.

Kojiro, Daniel R.↗

Compact Microwave Fourier Spectrum Analyzer

A compact photonic microwave Fourier spectrum analyzer [a Fourier-transform microwave spectrometer, (FTMWS)] with no moving parts has been proposed for use in remote sensing of weak, natural microwave emissions from the surfaces and atmospheres of planets to enable remote analysis and determination of chemical composition and abundances of critical molecular constituents in space. The instrument is based on a Bessel beam (light modes with non-zero angular momenta) fiber-optic elements. It features low power consumption, low mass, and high resolution, without a need for any cryogenics, beyond what is achievable by the current state-of-the-art in space instruments. The instrument can also be used in a wide-band scatterometer mode in active radar systems.

Savchenkov, Anatoliy↗

First Detection of Non-Chlorinated Organic Molecules Indigenous to a Martian Sample

The Sample Analysis at Mars (SAM) instrument onboard Curiosity can perform pyrolysis of martian solid samples, and analyze the volatiles by direct mass spectrometry in evolved gas analysis (EGA) mode, or separate the components in the GCMS mode (coupling the gas chromatograph and the mass spectrometer instruments). In addition, SAM has a wet chemistry laboratory designed for the extraction and identification of complex and refractory organic molecules in the solid samples. The chemical derivatization agent used, N-methyl-N-tert-butyldimethylsilyl- trifluoroacetamide (MTBSTFA), was sealed inside seven Inconel metal cups present in SAM. Although none of these foil-capped derivatization cups have been punctured on Mars for a full wet chemistry experiment, an MTBSTFA leak was detected and the resultant MTBSTFA vapor inside the instrument has been used for a multi-sol MTBSTFA derivatization (MD) procedure instead of direct exposure to MTBSTFA liquid by dropping a solid sample directly into a punctured wet chemistry cup. Pyr-EGA, Pyr-GCMS and Der-GCMS experiments each led to the detection and identification of a variety of organic molecules in diverse formations of Gale Crater.

Freissinet, C.↗

Seasonal Variations in Atmospheric Composition as Measured in Gale Crater, Mars

The Sample Analysis at Mars (SAM) instrument onboard the Mars Science Laboratory Curiosity rover measures the chemical composition of major atmospheric species (CO2, N2, 40Ar,O2, and CO) through a dedicated atmospheric inlet. We report here measurements of volume mixing ratios in Gale Crater using the SAM quadrupole mass spectrometer, obtained over a period of nearly 5 years (3 Mars years) from landing. The observation period spans the northern summer of MY31 and solar longitude (L(sub S)) of 175° through spring of MY 34, L(sub S) = 12°. This work expands upon prior reports of the mixing ratios measured by SAM QMS in the first 105 sols of the mission. The SAM QMS atmospheric measurements were taken periodically, with a cumulative coverage of four or five experiments per season on Mars. Major observations include the seasonal cycle of CO2, N2, and Ar, which lags approximately 20–40° of L(sub S) behind the pressure cycle driven by CO2 condensation and sublimation from the winter poles. This seasonal cycle indicates that transport occurs on faster timescales than mixing. The mixing ratio of O2 shows significant seasonal and interannual variability, suggesting an unknown atmospheric or surface process at work. The O2 measurements are compared to several parameters, including dust optical depth and trace CH4 measurements by Curiosity. We derive annual mean volume mixing ratios for the atmosphere in Gale Crater: CO2 = 0.951 (±0.003), N2 = 0.0259 (±0.0006), 40Ar = 0.0194 (±0.0004), O2 = 1.61 (±0.09) x 10(exp ‐3), and CO = 5.8 (±0.8) x 10(exp ‐4).

Gale Crater↗

Sample Processing Instrumentation to Enable Lab-like Analysis of Lipids, Hydrocarbons, and Kerogen in situ

Introduction: Over the last decade, our team based out of NASA Ames Research Center has made advances in fluidic technologies to enable laboratory-grade processes in space environments. More recently, we have designed and developed two instruments that utilize sample processing steps to extract and purify organic molecules that are key targets in the search for life. The first instrument targets soluble lipids and hydrocarbons that have been preserved in soil or rock material for millions to billions of years called ExCALiBR (Extractor for Chemical Analysis of Lipid Biomarkers in Regolith). The second instrument called KAMELOT (Kerogen and Macromolecule Extractor Liberating Organics Thermolytically) targets kerogen or insoluble macromolecular material that reside in the residue left behind after solvent extraction. Together, these instruments can be coupled to existing flight sample acquisition and analytical instrumentation (e.g., mass spectrometers) to achieve our overall science goal of identifying molecular patterns and features that are diagnostic of how the organic matter was synthesized, either through biological or non-biological processes.

Mary Beth Wilhelm↗

The Mineralogical and Chemical Case for Habitability at Yellowknife Bay, Gale Crater, Mars

Sediments of the Yellowknife Bay formation (Gale crater) include the Sheepbed member, a mudstone cut by light-toned veins. Two drill samples, John Klein and Cumberland, were collected and analyzed by the CheMin XRD/XRF instrument and the Sample Analysis at Mars (SAM) evolved gas and isotopic analysis suite of instruments. Drill cuttings were also analyzed by the Alpha Particle X-ray Spectrometer (APXS) for bulk composition. The CheMin XRD analysis shows that the mudstone contains basaltic minerals (Fe-forsterite, augite, pigeonite, plagioclase), as well as Fe-oxide/hydroxides, Fe-sulfides, amorphous materials, and trioctahedral phyllosilicates. SAM evolved gas analysis of higher-temperature OH matches the CheMin XRD estimate of ~20% clay minerals in the mudstone. The light-toned veins contain Ca-sulfates; anhydrite and bassanite are detected by XRD but gypsum is also indicated from Mastcam spectral mapping. These sulfates appear to be almost entirely restricted to late-diagenetic veins. The sulfate content of the mudstone matrix itself is lower than other sediments analyzed on Mars. The presence of phyllosilicates indicates that the activity of water was high during their formation and/or transport and deposition (should they have been detrital). Lack of chlorite places limits on the maximum temperature of alteration (likely <100 C). The presence of Ca-sulfates rather than Mg- or Fe-sulfates suggests that the pore water pH was near-neutral and of relatively low ionic strength (although x-ray amorphous Mg-and Fe- sulfates could be present and undetectable by CheMin). The presence of Fe and S in both reduced and oxidized states represents chemical disequilibria that could have been utilized by chemolithoautotrophic biota, if present. When compared to the nearby Rocknest sand shadow mineralogy or the normative mineralogy of Martian soil, both John Klein and Cumberland exhibit a near-absence of olivine and a surplus of magnetite (7-9% of the crystalline component). The magnetite is interpreted as an authigenic product formed when olivine was altered to phyllosilicate. Saponitization of olivine (a process analogous to serpentinization) could have produced H2 in situ. Indeed, early diagenetic hollow nodules ("minibowls") present in the Cumberland mudstone are interpreted by some as forming when gas bubbles accumulated in the unconsolidated mudstone. Lastly, all of these early diagenetic features appear to have been preserved with minimal alteration since their formation, as indicated by the ease of drilling (weak lithification, lack of cementing phases), the presence of 20-30% amorphous material, and the late-stage fracturing with emplacement of calcium sulfate veins and minibowl infills, where they were intersected by veins. A rough estimate of the minimum duration of the lacustrine environment is provided by the minimum thickness of the Sheepbed member. Given 1.5 meters, and applying a mean sediment accumulation rate for lacustrine strata of 1 m/1000 yrs yields a duration of 1,500 years. If the aqueous environments represented by overlying strata are considered, such as Gillespie Lake and Shaler, then this duration increases. The Sheepbed mudstone meets all the requirements of a habitable environment: Aqueous deposition at clement conditions of P, T, pH, Eh and ionic strength, plus the availability of sources of chemical energy.

Blake, David Frederick↗

Miniature Mass Spectrometers on Space and Planetary Missions

Space flight mass spectrometers contribute our understanding of the origin and evolution of our solar system and even of life itself. This fundamental role has motivated increasing interest in miniature mass spectrometry for planetary missions. Several remarkable new instruments are en route or under development to investigate the composition of planetary bodies such as Mars and comets. For instance, the Sample Analysis at Mars (SAM) suite on the 2009 Mars Science Laboratory (MSL) mission includes a quadrupole mass spectrometer with a sophisticated gas processing system as well as pyrolysis and chemical derivatization protocols for solid samples. Future missions will require even lighter, lower power, and yet more capable mass spectrometers, particularly to analyze samples in situ on planetary surfaces. We have been developing laser-based mass spectrometers for elemental and organic/molecular analysis of rock, ice, or fine particle samples. These typically use time-of-flight (TOF) mass analyzers, which are readily miniaturized and can detect both atomic species and complex organics that occur in a variety of planetary materials. For example, nonvolatile polycyclic aromatic hydrocarbons and kerogen-like macromolecular carbon are found in some carbonaceous meteorites, which derived from asteroid parent bodies. A single focused laser pulse is able to volatilize and ionize some of these compounds for direct TOF analysis. While this is possible without any sample preparation or contact, sensitivity and quantitative performance can improve significantly with some sample handling. As such we have also been examining robotic mechanisms and protocols to accompany space flight mass spectrometers. In addition, sensors in early development may significantly improve these capabilities, via use of techniques such as switchable polarity, ambient pressure, or resonant ionization; tandem mass spectrometry (TOF or ion trap); and chemical imaging.

Brinckerhoff, William↗

ATLAS: Airborne Tunable Laser Absorption Spectrometer for stratospheric trace gas measurements

The ATLAS instrument is an advanced technology diode laser based absorption spectrometer designed specifically for stratospheric tracer studies. This technique was used in the acquisition of N2O tracer data sets on the Airborne Antarctic Ozone Experiment and the Airborne Arctic Stratospheric Expedition. These data sets have proved valuable for comparison with atmospheric models, as well as in assisting in the interpretation of the entire ensemble of chemical and meteorological data acquired on these two field studies. The N2O dynamical tracer data set analysis revealed several ramifications concerning the polar atmosphere: the N2O/NO(y) correlation, which is used as a tool to study denitrification in the polar vertex; the N2O Southern Hemisphere morphology, showing subsidence in the winter polar vortex; and the value of the N2O measurements in the interpretation of ClO, O3, and NO(y) measurements and of the derived dynamical tracer, potential vorticity. Field studies also led to improved characterization of the instrument and to improved accuracy.

Loewenstein, Max↗

Calibration and Sequence Development Status for the Sample Analysis at Mars Investigation on the Mars Science Laboratory

The measurement goals of the Sample Analysis at Mars (SAM) instrument suite on the "Curiosity" Rover of the Mars Science Laboratory (MSL) include chemical and isotopic analysis of organic and inorganic volatiles for both atmospheric and solid samples [1,2]. SAM directly supports the ambitious goals of the MSL mission to provide a quantitative assessment of habitability and preservation in Gale crater by means of a range of chemical and geological measurements [3]. The SAM FM combined calibration and environmental testing took place primarily in 2010 with a limited set of tests implemented after integration into the rover in January 2011. The scope of SAM FM testing was limited both to preserve SAM consumables such as life time of its electromechanical elements and to minimize the level of terrestrial contamination in the SAM instrument. A more comprehensive calibration of a SAM-like suite of instruments will be implemented in 2012 with calibration runs planned for the SAM testbed. The SAM Testbed is nearly identical to the SAM FM and operates in a ambient pressure chamber. The SAM Instrument Suite: SAM's instruments are a Quadrupole Mass Spectrometer (QMS), a 6-column Gas Chromatograph (GC), and a 2-channel Tunable Laser Spectrometer (TLS). Gas Chromatography Mass Spectrometry is designed for identification of even trace organic compounds. The TLS [5] secures the C, H, and O isotopic composition in carbon dioxide, water, and methane. Sieved materials are delivered from the MSL sample acquisition and processing system to one of68 cups of the Sample Manipulation System (SMS). 59 of these cups are fabricated from inert quartz. After sample delivery, a cup is inserted into one of 2 ovens for evolved gas analysis (EGA ambient to >9500C) by the QMS and TLS. A portion of the gas released can be trapped and subsequently analyzed by GCMS. Nine sealed cups contain liquid solvents and chemical derivatization or thermochemolysis agents to extract and transform polar molecules such as amino acids, nucleobases, and carboxylic acids into compounds that are sufficiently volatile to transmit through the GC columns. The remaining 6 cups contain calibrants. SAM FM Calibration Overview: The SAM FM calibration in the Mars chamber employed a variety of pure gases, gas mixtures, and solid materials. Isotope calibration runs for the TLS utilized 13C enriched C02 standards and 0 enriched CH4. A variety of fluorocarbon compounds that spanned the entire mass range of the QMS as well as C3-C6 hydrocarbons were utilized for calibration of the GCMS. Solid samples consisting of a mixture of calcite, melanterite, and inert silica glass either doped or not with fluorocarbons were introduced into the SAM FM cups through the SAM inlet funnel/tube system.

Mahaffy, Paul R.↗

Biological particle analysis by mass spectrometry

An instrument that analyzes the chemical composition of biological particles in aerosol or hydrosol form was developed. Efforts were directed toward the acquisition of mass spectra from aerosols of biomolecules and bacteria. The filament ion source was installed on the particle analysis by mass spectrometry system. Modifications of the vacuum system improved the sensitivity of the mass spectrometer. After the modifications were incorporated, detailed mass spectra of simple compounds from the three major classes of biomolecules, proteins, nucleic acids, and carbohydrates were obtained. A method of generating bacterial aerosols was developed. The aerosols generated were collected and examined in the scanning electron microscope to insure that the bacteria delivered to the mass spectrometer were intact and free from debris.

Vilker, V. L.↗

Analytical Techniques for Retrieval of Atmospheric Composition with the Quadrupole Mass Spectrometer of the Sample Analysis at Mars Instrument Suite on Mars Science Laboratory

The Sample Analysis at Mars (SAM) instrument suite is the largest scientific payload on the Mars Science Laboratory (MSL) Curiosity rover, which landed in Mars׳ Gale Crater in August 2012. As a miniature geochemical laboratory, SAM is well-equipped to address multiple aspects of MSL׳s primary science goal, characterizing the potential past or present habitability of Gale Crater. Atmospheric measurements support this goal through compositional investigations relevant to martian climate evolution. SAM instruments include a quadrupole mass spectrometer, a tunable laser spectrometer, and a gas chromatograph that are used to analyze martian atmospheric gases as well as volatiles released by pyrolysis of solid surface materials (Mahaffy et al., 2012). This report presents analytical methods for retrieving the chemical and isotopic composition of Mars׳ atmosphere from measurements obtained with SAM׳s quadrupole mass spectrometer. It provides empirical calibration constants for computing volume mixing ratios of the most abundant atmospheric species and analytical functions to correct for instrument artifacts and to characterize measurement uncertainties. Finally, we discuss differences in volume mixing ratios of the martian atmosphere as determined by SAM (Mahaffy et al., 2013) and Viking (Owen et al., 1977, Oyama and Berdahl, 1977) from an analytical perspective. Although the focus of this paper is atmospheric observations, much of the material concerning corrections for instrumental effects also applies to reduction of data acquired with SAM from analysis of solid samples.

quadropole mass spectometer↗

The Sample Analysis at Mars Investigation and Instrument Suite

The Sample Analysis at Mars (SAM) investigation of the Mars Science Laboratory(MSL) addresses the chemical and isotopic composition of the atmosphere and volatilesextracted from solid samples. The SAM investigation is designed to contribute substantiallyto the mission goal of quantitatively assessing the habitability of Mars as an essentialstep in the search for past or present life on Mars. SAM is a 40 kg instrument suite locatedin the interior of MSLs Curiosity rover. The SAM instruments are a quadrupole massspectrometer, a tunable laser spectrometer, and a 6-column gas chromatograph all coupledthrough solid and gas processing systems to provide complementary information on thesame samples. The SAM suite is able to measure a suite of light isotopes and to analyzevolatiles directly from the atmosphere or thermally released from solid samples. In additionto measurements of simple inorganic compounds and noble gases SAM will conducta sensitive search for organic compounds with either thermal or chemical extraction fromsieved samples delivered by the sample processing system on the Curiosity rovers roboticarm.

isotopes↗

The C23A system, an exmaple of quantitative control of plant growth associated with a data base

The architecture of the C23A (Chambers de Culture Automatique en Atmosphere Artificielles) system for the controlled study of plant physiology is described. A modular plant growth chambers and associated instruments (I.R. CO2 analyser, Mass spectrometer and Chemical analyser); network of frontal processors controlling this apparatus; a central computer for the periodic control and the multiplex work of processors; and a network of terminal computers able to ask the data base for data processing and modeling are discussed. Examples of present results are given. A growth curve analysis study of CO2 and O2 gas exchanges of shoots and roots, and daily evolution of algal photosynthesis and of the pools of dissolved CO2 in sea water are discussed.

Andre, M.↗

Galileo Probe Mass Spectrometer experiment

The chemical and isotopic composition of the Jupiter atmosphere's constituents, including their vertical variations, will be measured by the Galileo Probe Mass Spectrometer instrument through in situ sampling; batch sampling will also be undertaken for noble gas composition and isotopic ratio determinations. The instrument's gas-sampling system is connected to a quadrupole mass analyzer for molecular weight analysis. Threshold values are lowered through sample enrichment by a factor of 100-500 for stable hydrocarbons and by a factor of 10 for noble gases. The instrument follows a sampling sequence of 8192 steps, at a rate of 2 steps/sec.

Niemann, H. B.↗

Proceedings of the 40th Lunar and Planetary Science Conference

The 40th Lunar and Planetary Science Conference included sessions on: Phoenix: Exploration of the Martian Arctic; Origin and Early Evolution of the Moon; Comet Wild 2: Mineralogy and More; Astrobiology: Meteorites, Microbes, Hydrous Habitats, and Irradiated Ices; Phoenix: Soil, Chemistry, and Habitability; Planetary Differentiation; Presolar Grains: Structures and Origins; SPECIAL SESSION: Venus Atmosphere: Venus Express and Future Missions; Mars Polar Caps: Past and Present; SPECIAL SESSION: Lunar Missions: Results from Kaguya, Chang'e-1, and Chandrayaan-1, Part I; 5 Early Nebula Processes and Models; SPECIAL SESSION: Icy Satellites of Jupiter and Saturn: Cosmic Gymnasts; Mars: Ground Ice and Climate Change; SPECIAL SESSION: Lunar Missions: Results from Kaguya, Chang'e-1, and Chandrayaan-1, Part II; Chondrite Parent-Body Processes; SPECIAL SESSION: Icy Satellites of Jupiter and Saturn: Salubrious Surfaces; SNC Meteorites; Ancient Martian Crust: Primary Mineralogy and Aqueous Alteration; SPECIAL SESSION: Messenger at Mercury: A Global Perspective on the Innermost Planet; CAIs and Chondrules: Records of Early Solar System Processes; Small Bodies: Shapes of Things to Come; Sulfur on Mars: Rocks, Soils, and Cycling Processes; Mercury: Evolution and Tectonics; Venus Geology, Volcanism, Tectonics, and Resurfacing; Asteroid-Meteorite Connections; Impacts I: Models and Experiments; Solar Wind and Genesis: Measurements and Interpretation; Mars: Aqueous Processes; Magmatic Volatiles and Eruptive Conditions of Lunar Basalts; Comparative Planetology; Interstellar Matter: Origins and Relationships; Impacts II: Craters and Ejecta Mars: Tectonics and Dynamics; Mars Analogs I: Geological; Exploring the Diversity of Lunar Lithologies with Sample Analyses and Remote Sensing; Chondrite Accretion and Early History; Science Instruments for the Mars Science Lander; . Martian Gullies: Morphology and Origins; Mars: Dunes, Dust, and Wind; Mars: Volcanism; Early Solar System Chronology; Seek Out and Explore: Upcoming and Future Missions; Mars: Early History and Impact Processes; Mars Analogs II: Chemical and Spectral; Achondrites and their Parent Bodies; and Planning for Future Exploration of the Moon The poster sessions were: Lunar Missions: Results from Kaguya, Chang'e-1, and Chandrayaan-1; LRO and LCROSS; Geophysical Analysis of the Lunar Surface and Interior; Remote Observation and Geologic Mapping of the Lunar Surface; Lunar Spectroscopy; Venus Geology, Geophysics, Mapping, and Sampling; Planetary Differentiation; Bunburra and Buzzard Coulee: Recent Meteorite Falls; Meteorites: Terrestrial History; CAIs and Chondrules: Records of Early Solar System Processes; Volatile and Organic Compounds in Chondrites; Crashing Chondrites: Impact, Shock, and Melting; Ureilite Studies; Petrology and Mineralogy of the SNC Meteorites; Martian Meteorites; Phoenix Landing Site: Perchlorate and Other Tasty Treats; Mars Polar Atmospheres and Climate Modeling; Mars Polar Investigations; Mars Near-Surface Ice; Mars: A Volatile-Rich Planet; Mars: Geochemistry and Alteration Processes; Martian Phyllosilicates: Identification, Formation, and Alteration; Astrobiology; Instrument Concepts, Systems, and Probes for Investigating Rocks and Regolith; Seeing is Believing: UV, VIS, IR, X- and Gamma-Ray Camera and Spectrometer Instruments; Up Close and Personal: In Situ Analysis with Laser-Induced Breakdown Spectroscopy and Mass Spectrometry; Jupiter and Inscrutable Io; Tantalizing Titan; Enigmatic Enceladus and Intriguing Iapetus; Icy Satellites: Cryptic Craters; Icy Satellites: Gelid Geology/Geophysics; Icy Satellites: Cool Chemistry and Spectacular Spectroscopy; Asteroids and Comets; Comet Wild 2: Mineralogy and More; Hypervelocity Impacts: Stardust Models, LDEF, and ISPE; Presolar Grains; Early Nebular Processes: Models and Isotopes; Solar Wind and Genesis: Measurements and Interpretation; Education and Public Outreach; Mercury; Pursuing Lunar Exploration; Sources and Eruptionf Lunar Basalts; Chemical and Physical Properties of the Lunar Regolith; Lunar Dust and Transient Surface Phenomena; Lunar Databases and Data Restoration; Meteoritic Samples of the Moon; Chondrites, Their Clasts, and Alteration; Achondrites: Primitive and Not So Primitive; Iron Meteorites; Meteorite Methodology; Antarctic Micrometeorites; HEDs and Vesta; Dust Formation and Transformation; Interstellar Organic Matter; Early Solar System Chronology; Comparative Planetology; Impacts I: Models and Experiments; Impacts II: Craters and Ejecta; Mars: Volcanism; Mars: Tectonics and Dynamics; Martian Stratigraphy: Understanding the Geologic History of Mars Through the Sedimentary Rock Record; Mars: Valleys and Valley Networks; Mars: Aqueous Processes in Valles Marineris and the Southern Highlands; Mars: Aqueous Geomorphology; Martian Gullies: Morphology and Origins; Mars: Dunes, Dust, and Wind; Mars: Remote Sensing; Mars: Geologic Mapping, Photogrammetry, and Cratering; Martian Mineralogy: Constraints from Missions and Laboratory Investigations; Mars Analogs: Chemical and Physical; Mars Analogs: Sulfates and Sulfides; Missions: Approaches, Architectures, Analogs, and Actualities; Not Just Skin Deep: Electron Microscopy, Heat Flow, Radar, and Seismology Instruments and Planetary Data Systems, Techniques, and Interpretation.

Source record↗