Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectrometry data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Multivariate Analysis of MALDI Imaging Mass Spectrometry Data of Mixtures of Single Pollen Grains

Mixtures of pollen grains of three different species (Corylus avellana, Alnus cordata, and Pinus sylvestris) were investigated by matrix-assisted laser desorption/ionization time-of-flight imaging mass spectrometry (MALDI-TOF imaging MS). The amount of pollen grains was reduced stepwise from > 10 to single pollen grains. For sample pretreatment, we modified a previously applied approach, where any additional extraction steps were omitted. Our results show that characteristic pollen MALDI mass spectra can be obtained from a single pollen grain, which is the prerequisite for a reliable pollen classification in practical applications. MALDI imaging of laterally resolved pollen grains provides additional information by reducing the complexity of the MS spectra of mixtures, where frequently peak discrimination is observed. Combined with multivariate statistical analyses, such as principal component analysis (PCA), our approach offers the chance for a fast and reliable identification of individual pollen grains by mass spectrometry. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fuzzy Logic Classification of Imaging Laser Desorption Fourier Transform Mass Spectrometry Data

The fuzzy logic method is applied to classification of mass spectra obtained with an imaging internal source Fourier transform mass spectrometer (I2LD-FTMS). Traditionally, an operator uses the relative abundance of ions with specific mass-to-charge (m/z) ratios to categorize spectra. An operator does this by comparing the spectrum of m/z versus abundance of an unknown sample against a library of spectra from known samples. Automated positioning and acquisition allow the I2LD-FTMS to acquire data from very large grids, which would require classification of up to 3600 spectra per hour to keep pace with the acquisition. The tedious job of classifying numerous spectra generated in an I2LD-FTMS imaging application can be replaced by a fuzzy rule base if the cues an operator uses can be encapsulated. Appropriate methods for assigning fuzzy membership values for inputs (e.g., mass spectrum abundances) and choice of fuzzy inference operators to translate linguistic antecedent into confidence values for the consequence (or in this case the classification) is followed by using the maximum confidence and a necessary minimum threshold for making a crisp decision. This paper also describes a method for gathering statistics on ions, which are not currently used in the rule base, but which may be candidates for making the rule base more accurate and complete or to form new rule bases based on data obtained from known samples. A spatial method for classifying spectra with low membership values, based on neighboring sample classifications, is also presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LipidMiner: A Software for Automated Identification and Quantification of Lipids from Multiple Liquid Chromatography-Mass Spectrometry Data Files

We have developed a tool for automated, high-throughput analysis of LC-MS/MS data files, which greatly simplifies LC-MS based lipidomics analysis. Our results showed that LipidMiner is accurate and comprehensive in identification and quantification of lipid molecular species. In addition, the workflow implemented in LipidMiner is not limited to identification and quantification of lipids. If a suitable metabolite library is implemented in the library matching module, LipidMiner could be reconfigured as a tool for general metabolomics data analysis. It is of note that LipidMiner currently is limited to singly charged ions, although it is adequate for the purpose of lipidomics since lipids are rarely multiply charged,[14] even for the polyphosphoinositides. LipidMiner also only processes file formats generated from mass spectrometers from Thermo, i.e. the .RAW format. In the future, we are planning to accommodate file formats generated by mass spectrometers from other predominant instrument vendors to make this tool more universal.

Environmental Molecular Sciences Laboratory↗

Comparative Evaluation of Preprocessing Freeware on Chromatography/Mass Spectrometry Data for Signature Discovery

Preprocessing software is crucial for the discovery of chemical signatures in metabolomics, chemical forensics, and other signature-focused disciplines that involve analyzing large data sets from chemical instruments. Here, four freely available and published preprocessing tools known as metAlign, MZmine, SpectConnect, and XCMS were evaluated for impurity profiling using nominal mass GC/MS data and accurate mass LC/MS data. Both data sets were previously collected from the analysis of replicate samples from multiple stocks of a nerve-agent precursor. Each of the four tools had their parameters set for the untargeted detection of chromatographic peaks from impurities present in the stocks. The peak table generated by each preprocessing tool was analyzed to determine the number of impurity components detected in all replicate samples per stock. A cumulative set of impurity components was then generated using all available peak tables and used as a reference to calculate the percent of component detections for each tool, in which 100% indicated the detection of every component. For the nominal mass GC/MS data, metAlign performed the best followed by MZmine, SpectConnect, and XCMS with detection percentages of 83, 60, 47, and 42%, respectively. For the accurate mass LC/MS data, the order was metAlign, XCMS, and MZmine with detection percentages of 80, 45, and 35%, respectively. SpectConnect did not function for the accurate mass LC/MS data. Larger detection percentages were obtained by combining the top performer with at least one of the other tools such as 96% by combining metAlign with MZmine for the GC/MS data and 93% by combining metAlign with XCMS for the LC/MS data. In terms of quantitative performance, the reported peak intensities had average absolute biases of 41, 4.4, 1.3 and 1.3% for SpectConnect, metAlign, XCMS, and MZmine, respectively, for the GC/MS data. For the LC/MS data, the average absolute biases were 22, 4.5, and 3.1% for metAlign, MZmine, and XCMS, respectively. In summary, metAlign performed the best in terms of peak discovery; however, more than one preprocessing tool should be considered to avoid missing potential chemical signatures.

chemical forensics, chemometrics↗

Exploring Ion Mobility Mass Spectrometry Data File Conversions to Leverage Existing Tools and Enable New Workflows

Ion mobility (IM) is often combined with LC-MS experiments to provide an additional dimension of separation for complex sample analysis. While highly complex samples are better characterized by the full dimensionality of LC-IM-MS experiments to uncover new information, downstream data analysis workflows are often not equipped to properly mine the additional IM dimension. For many samples the data acquisition benefits of including IM separations are all that is necessary to uncover sample information and the full dimensionality of the data is not required for data analysis. Post-acquisition reduction and adaptation of the dimensions of LC-IM-MS and IM-MS experiments into an LC-MS format opens the possibility to use a plethora of existing software tools. In this work, we developed data file conversion tools to reduce the complexity of IM data analysis. Three data file transformations are introduced in the PNNL PreProcessor software: 1) mapping the IM axis to the LC axis for IM-MS data, 2) converting the drift time vs. m/z space to CCS/z vs m/z space, and 3) transforming All Ions IM/MS mobility aligned fragmentation data to a standard LC-MS DDA data file format. Finally, these new data file conversions are demonstrated with corresponding lipidomics and proteomics workflows that leverage existing LC-MS data analysis software to highlight the benefits of the data transformations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Author Correction: A universal language for finding mass spectrometry data patterns

Correction to: Nature Methodshttps://doi.org/10.1038/s41592-025-02660-z, published online 12 May 2025. This article was originally published under standard Springer Nature license (© The Author(s), under exclusive licence to Springer Nature America, Inc.). It is now available as an open-access paper under a Creative Commons Attribution 4.0 International license, © The Author(s). The error has been corrected in the HTML and PDF versions of the article.

Damiani, Tito↗

Image processing software for imaging spectrometry data analysis

Imaging spectrometers simultaneously collect image data in hundreds of spectral channels, from the near-UV to the IR, and can thereby provide direct surface materials identification by means resembling laboratory reflectance spectroscopy. Attention is presently given to a software system, the Spectral Analysis Manager (SPAM) for the analysis of imaging spectrometer data. SPAM requires only modest computational resources and is composed of one main routine and a set of subroutine libraries. Additions and modifications are relatively easy, and special-purpose algorithms have been incorporated that are tailored to geological applications.

Mazer, Alan↗

Inversion of imaging spectrometry data using singular value decomposition

The use of imaging spectrometers, which acquire data that are both spectrally contiguous images and spatially contiguous spectra, for quantitative remote sensing of the earth is addressed. Such data sets cannot be analyzed fully using either existing spectroscopic or image techniques. Singular value decomposition (SVD) is used here for spectral unmixing and determination of the spatial scales of mixing. It is shown that when it is used to invert the mixing endmember library, SVD allows more insight into library characteristics and more control of the inversion process than other commonly used matrix inversion techniques.

Boardman, Joe W.↗

Calibration to surface reflectance of terrestrial imaging spectrometry data: Comparison of methods

Many algorithms for spectral analysis of imaging spectroscopy data of the Earth's surface require that the data be calibrated to surface reflectance. Calibration requires removing instrumental response, solar irradiance, atmospheric transmittance, and atmospheric scattering from the radiance detected at the sensor. Depending on the amount of support data, this can be a formidable task. This paper examines four methods of calibration: (1) a radiative transfer model from the University of Colorado (ATREM: Gao and Goetz, 1990; Gao et al., 1992), (2) a MODTRAN-based method developed at the Jet Propulsion Lab by Green et al., (1191), (3) a ground calibration using known sites as standards, and (4) a combined approach using radiative transfer methods and ground calibration. Data from the Airborne Visual and Infra-Red Imaging Spectrometer (AVIRIS) instrument were evaluated from data sets obtained over multiple years and multiple sites.

Clark, Roger N.↗

High Accuracy In-Flight Wavelength Calibration of Imaging Spectrometry Data

Accurate wavelength calibration of imaging spectrometer data is essential if proper atmospheric transmission corrections are to be made to obtain apparent surface reflectance. Accuracies of 0.1 nm are necessary for a 10 nm-sampling instrument in order to match the slopes of the deep atmospheric water vapor features that dominate the 0.7-2.3 micrometer regions. The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) is calibrated in the laboratory to determine the wavelength position and full-width-half-maximum (FWHM) response for each of the 224 channels. The accuracies are limited by the quality of the monochromator used as a source. The accuracies vary from plus or minus to plus or minus 1.5 nm depending on the wavelength region, in general decreasing with increasing wavelength. Green et al. make corrections to the wavelength calibrations by using the known positions of 14 atmospheric absorption features throughout the 0.4-2.5 micrometer wavelength region. These features, having varying width and intensity, were matched to the MODTRAN model with a non-linear least squares fitting algorithm. A complete calibration was developed for all 224 channels by interpolation. Instrument calibration cannot be assumed to be stable to 0.1 nm over a flight season given the rigors of thermal cycling and launch and landing loads. The upcoming sensor HYDICE will require a means for in-flight spectral calibration of each scene because the calibration is both temperature and pressure sensitive. In addition, any sensor using a two-dimensional array has the potential for systematic wavelength shifts as a function of cross-track position, commonly called 'smile'. Therefore, a rapid means for calibrating complete images will be required. The following describes a method for determining instrument wavelength calibration using atmospheric absorption features that is efficient enough to be used for entire images on workstations. This study shows the effect of the surface reflectance on the calibration accuracy and the calibration history for the AVIRIS B spectrometer over the 1992 flight season.

Goetz, Alexander F. H.↗