Search NASA⌕ Search

SEARCH · Search NASA

Results for “squids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A three-axis SQUID-based absolute vector magnetometer

We report on the development of a three-axis absolute vector magnetometer suited for mobile operation in the Earth’s magnetic field. It is based on low critical temperature dc superconducting quantum interference devices (LTS dc SQUIDs) with sub-micrometer sized cross-type Josephson junctions and exhibits a white noise level of about 10 fT/Hz{sup 1/2}. The width of superconducting strip lines is restricted to less than 6 μm in order to avoid flux trapping during cool-down in magnetically unshielded environment. The long-term stability of the flux-to-voltage transfer coefficients of the SQUID electronics is investigated in detail and a method is presented to significantly increase their reproducibility. We further demonstrate the long-term operation of the setup in a magnetic field varying by about 200 μT amplitude without the need for recalibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scanning SQUID microscopy in a cryogen-free dilution refrigerator

We report a scanning superconducting quantum interference device (SQUID) microscope in a cryogen-free dilution refrigerator with a base temperature at the sample stage of at least 30 mK. The microscope is rigidly mounted to the mixing chamber plate to optimize thermal anchoring of the sample. The microscope housing fits into the bore of a superconducting vector magnet, and our design accommodates a large number of wires connecting the sample and sensor. Through a combination of vibration isolation in the cryostat and a rigid microscope housing, we achieve relative vibrations between the SQUID and the sample that allow us to image with micrometer resolution over a 150 μm range while the sample stage temperature remains at base temperature. To demonstrate the capabilities of our system, we show images acquired simultaneously of the static magnetic field, magnetic susceptibility, and magnetic fields produced by a current above a superconducting micrometer-scale device.

47 OTHER INSTRUMENTATION↗

Scanning SQUID characterization of extremely overdoped La 2-x Sr x CuO 4

Recently, advances in film synthesis methods have enabled a study of extremely overdoped La 2 - x Sr x Cu O 4 . This has revealed a surprising behavior of the superfluid density as a function of doping and temperature, the explanation of which is vividly debated. One popular class of models posits electronic phase separation, where the superconducting phase fraction decreases with doping, while some competing phase (e.g., ferromagnetic) progressively takes over. A problem with this scenario is that all the way up to the dome edge the superconducting transition remains sharp, according to mutual inductance measurements. However, the physically relevant scale is the Pearl penetration depth Λ P , and this technique probes the sample on a length scale L that is much larger than Λ P . In the present paper, we use local scanning superconducting quantum interference device (SQUID) measurements that probe the susceptibility of the sample on the scale L << Λ P . Our SQUID maps show uniform landscapes of susceptibility and excellent overall agreement of the local penetration depth data with the bulk measurements. Overall, these results contribute an important piece to the puzzle of how high-temperature superconductivity vanishes on the overdoped side of the cuprate phase diagram.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Vortex dynamics induced by scanning SQUID susceptometry

In this work, we measured the local magnetic response of a niobium thin film by applying a millitesla-scale AC magnetic field using a micron-scale field coil and detecting the response with a micron-scale pickup loop in a scanning superconducting quantum interference device (SQUID) susceptometry measurement. Near the film's critical temperature, we observed a steplike nonlinear and dissipative magnetic response due to the dynamics of a small number of vortex-antivortex pairs induced in the film by the local applied AC field. We modeled the dynamics of the measurement using a combined two-dimensional London-Maxwell and time-dependent Ginzburg-Landau approach, allowing us to construct a detailed real-space picture of the vortex motion causing the observed dissipative response. This work pushes scanning SQUID susceptometry of two-dimensional superconductors beyond the regime of linear response and lays the foundation for microscopic studies of vortex dynamics and pinning in superconducting devices and more exotic materials systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SQUID-Based Microwave Cavity Search for Dark-Matter Axions

Axions in the mueV mass range are a plausible cold dark-matter candidate and may be detected by their conversion into microwave photons in a resonant cavity immersed in a static magnetic field. We report the first result from such an axion search using a superconducting first-stage amplifier (SQUID) replacing a conventional GaAs field-effect transistor amplifier. This experiment excludes KSVZ dark-matter axions with masses between 3.3 mueV and 3.53 mueV and sets the stage for a definitive axion search utilizing near quantum-limited SQUID amplifiers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ordinary SQUID interferometers and superfluid helium matter wave interferometers: The role of quantum fluctuations

When comparing the operation of a superfluid helium matter wave quantum interferometer (He SQUID) with that of an ordinary direct-current quantum interferometer (dc SQUID), we estimate their resolution limitation that correspond to quantum fluctuations. An alternative mode of operation of the interferometer as a unified macroquantum system is considered.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Energetics of an rf SQUID Coupled to Two Thermal Reservoirs

We study energetics of a Josephson tunnel junction connecting a superconducting loop pierced by an external magnetic flux (an rf SQUID) and coupled to two independent thermal reservoirs of different temperature. In the framework of the theory of quantum dissipative systems, we analyze energy currents in stationary states. The stationary energy flow can be periodically modulated by the external magnetic flux exemplifying the rf SQUID as a quantum heat interferometer. Additionally, we consider the transient regime and identify three distinct regimes: monotonic decay, damped oscillations and pulse-type behavior of energy currents. Furthermore, the first two regimes can be controlled by the external magnetic flux while the last regime is robust against its variation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Crosstalk in microwave SQUID multiplexers

Low-temperature detector technologies provide extraordinary sensitivity for applications ranging from precision measurements of the cosmic microwave background to high-resolution, high-rate x-ray, and γ-ray spectroscopy. To utilize this sensitivity, new instruments are being built, and new instruments are imagined, with ever greater pixel counts, but the scale of these instruments is limited by the capability of the readout electronics. Microwave SQUID multiplexing addresses the needs of these future instruments, exploiting gigahertz of bandwidths of coaxial cables and broadband components to combine hundreds to thousands of signals on a single readout line. A key feature of any multiplexer is the level of crosstalk between input channels. This crosstalk can degrade the sensitivity of the instrument, introduce systematic error, or simply confound data analysis. In this letter, we explain the primary mechanisms of crosstalk in a microwave SQUID multiplexer, calculate and measure their magnitude, and consider their effect and methods of mitigation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improved microwave SQUID multiplexer readout using a kinetic-inductance traveling-wave parametric amplifier

We report on the use of a kinetic-inductance traveling-wave parametric amplifier (KITWPA) as the first amplifier in the readout chain of a microwave superconducting quantum interference device (SQUID) multiplexer (μmux). This μmux is designed to multiplex signals from arrays of low temperature detectors, such as superconducting transition-edge sensor microcalorimeters. When modulated with a periodic flux-ramp to linearize the SQUID response, the flux noise improves, on average, from 1.6 μ $\Phi$ 0 /$\sqrt{Hz}$ with the KITWPA off to 0.77 μ $\Phi$ 0 /$\sqrt{Hz}$ with the KITWPA on. When statically biasing the μmux to the maximally flux-sensitive point, the flux noise drops from 0.45 μ $\Phi$ 0 /$\sqrt{Hz}$ to 0.2 μ $\Phi$ 0 /$\sqrt{Hz}$⁠. We validate this new readout scheme by coupling a transition-edge sensor microcalorimeter to the μmux and detecting background radiation. In conclusion, the combination of μmux and KITWPA provides a variety of new capabilities including improved detector sensitivity and more efficient bandwidth utilization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Robust and symmetric magnetic field dependency of superconducting diode effect in asymmetric Dirac semimetal SQUIDs

The recent demonstration of the superconducting diode effect (SDE) has generated renewed interest in superconducting electronics, in which devices such as compact superconducting diodes that can perform signal rectification with low-energy operations are needed. In this article, we present our results of robust and symmetric-in-magnetic-field SDE in asymmetric superconducting quantum interference devices (SQUIDs) realized in high-quality Dirac semimetal Cd 3 As 2 thin film grown by the molecular beam epitaxy technique. Consistent with previous work, a zero magnetic field SDE is observed. Furthermore, the difference in switching current is independent of the strength and polarity of an out-plane magnetic field in the range of −10 and 10 mT. We speculate that this robust symmetric-in-field SDE in our Dirac semimetal SQUIDs is due to the formation of helical spin texture, theoretically predicted in Dirac semimetals.

Current-voltage characteristic↗

Quantum Machine Learning with SQUID

In this work we present the Scaled QUantum IDentifier (SQUID), an open-source framework for exploring hybrid Quantum-Classical algorithms for classification problems. The classical infrastructure is based on PyTorch and we provide a standardized design to implement a variety of quantum models with the capability of back-propagation for efficient training. We present the structure of our framework and provide examples of using SQUID in a standard binary classification problem from the popular MNIST dataset. In particular, we highlight the implications for scalability for gradient-based optimization of quantum models on the choice of output for variational quantum models.

97 MATHEMATICS AND COMPUTING↗

Squid detected NMR and MRI at ultralow fields

Nuclear magnetic resonance (NMR) signals are detected in microtesla fields. Prepolarization in millitesla fields is followed by detection with an untuned dc superconducting quantum interference device (SQUID) magnetometer. Because the sensitivity of the SQUID is frequency independent, both signal-to-noise ratio (SNR) and spectral resolution are enhanced by detecting the NMR signal in extremely low magnetic fields, where the NMR lines become very narrow even for grossly inhomogeneous measurement fields. MRI in ultralow magnetic field is based on the NMR at ultralow fields. Gradient magnetic fields are applied, and images are constructed from the detected NMR signals.

47 OTHER INSTRUMENTATION↗

Bandwidth and Aliasing in the Microwave SQUID Multiplexer

The microwave SQUID multiplexer (μmux) has enabled higher bandwidth or higher channel counts across a wide range of experiments in particle physics, astronomy, and spectroscopy. The large multiplexing factor coupled with recent commercial availability of microwave components and warm electronics readout systems make it an attractive candidate for systems requiring large cryogenic detector counts. Since the multiplexer is considered for both bolometric and calorimetric applications across several orders of magnitude of signal frequencies, understanding the bandwidth of the device and its interaction with readout electronics is key to appropriately designing and engineering systems. Here we discuss several important factors contributing to the bandwidth properties of μmux systems, including the intrinsic device bandwidth, interactions with warm electronics readout systems, and aliasing. Further, we present simulations and measurements of μmux devices coupled with SLAC Microresonator RF (SMuRF) tone-tracking electronics and discuss several implications for future experimental design.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Crosstalk Effects in Microwave SQUID Multiplexed TES Bolometer Readout

Transition-edge sensor (TES) bolometers are broadly used for background-limited astrophysical measurements from the far-infrared to mm-waves. Many planned future instruments require increasingly large detector arrays, but their scalability is limited by their cryogenic readout electronics. Microwave SQUID multiplexing offers a highly capable scaling solution through the use of inherently broadband circuitry, enabling readout of hundreds to thousands of channels per microwave line. As with any multiplexing technique, the channelization mechanism gives rise to electrical crosstalk which must be understood and controlled so as to not degrade the instrument sensitivity. Here, in this study, we explore implications relevant for TES bolometer array applications, focusing in particular on upcoming mm-wave observatories such as the Simons Observatory and AliCPT. We model the relative contributions of the various underlying crosstalk mechanisms, evaluate the difference between fixed-tone and tone-tracking readout systems, and discuss ways in which crosstalk nonlinearity will complicate on-sky measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analytical results of the Fokker-Planck equation derived for one superconducting nanowire quantum interference device and for DC SQUIDs-asymmetric devices

We consider an asymmetric two-junction superconducting quantum interference device, whose junctions are assumed to be overdamped, and regard Sin Fourier series for their current-phase relations. We take into account the effects of thermal fluctuations by forming a two-dimensional Fokker-Planck equation for the distribution function. We judge a series expansion of first order with respect to the components of the reduced inductance for distribution function and obtain current-voltage relation. We consider the measured resistance of the superconducting nanowire quantum interference device with mesoscopic leads that Hopkins et al. reported in Hopkins et al. [D.S. Hopkins, D. Pekker, P.M. Goldbart, A. Bezryadin, Science 308 (2005) 1762] and analyzed in Pekker et al. [D. Pekker, A. Bezryadin, D.S. Hopkins, P.M. Goldbart, Phys. Rev. B 72 (2005) 104517], by defining loop inductance, and by considering appropriate relations for resistance of nanowires. In fact we extend Chesca formulation [B. Chesca, J. Low Temp. Phys. 112 (1998) 165] simultaneously in three aspects and give a unified theory for nanowire two-junction devices, low T{sub c} and high T{sub c} DC SQUIDs, in restricted conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spin transition in Gd{sub 3}N-C{sub 80}, detected by low-temperature on-chip SQUID technique

We present a magnetic study of the Gd{sub 3}N-C{sub 80} molecule, consisting of a Gd-trimer via a nitrogen atom, encapsulated in a C{sub 80} cage. This molecular system can be an efficient contrast agent for magnetic resonance imaging (MRI) applications. We used a low-temperature technique able to detect small magnetic signals by placing the sample in the vicinity of an on-chip SQUID. The technique implemented at the National High Magnetic Field Laboratory has the particularity of being able to operate in high magnetic fields of up to 7 T. The Gd{sub 3}N-C{sub 80} shows a paramagnetic behavior and we find a spin transition of the Gd{sub 3}N structure at 1.2 K. We perform quantum mechanical simulations, which indicate that one of the Gd ions changes from a {sup 8}S{sub 7/2} state (L = 0, S = 7/2) to a {sup 7}F{sub 6} state (L = S = 3, J = 6), likely due to a charge transfer between the C{sub 80} cage and the ion.

36 MATERIALS SCIENCE↗

An interchangeable scanning Hall probe/scanning SQUID microscope

We have constructed a scanning probe microscope for magnetic imaging, which can function as a scanning Hall probe microscope (SHPM) and as a scanning SQUID microscope (SSM). The scanning scheme, applicable to SHPM and SSM, consists of a mechanical positioning (sub) micron-XY stage and a flexible direct contact to the sample without a feedback control system for the Z-axis. With the interchangeable capability of operating two distinct scanning modes, our microscope can incorporate the advantageous functionalities of the SHPM and SSM with large scan range up to millimeter, high spatial resolution (⩽4 μm), and high field sensitivity in a wide range of temperature (4.2 K-300 K) and magnetic field (10{sup −7} T-1 T). To demonstrate the capabilities of the system, we present magnetic images scanned with SHPM and SSM, including a RbFeB magnet and a nickel grid pattern at room temperature, surface magnetic domain structures of a La{sub 2/3}Ca{sub 1/3}MnO{sub 3} thin film at 77 K, and superconducting vortices in a striped niobium film at 4.2 K.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Trace element content and magnetic properties of commercial HOPG samples studied by ion beam microscopy and SQUID magnetometry

In this study, the impurity concentration and magnetic response of nine highly oriented pyrolytic graphite (HOPG) samples with different grades and from different providers were determined using ion beam microscopy and SQUID magnetometry. Apart from sideface contaminations in the as-received state, bulk contamination of the samples in most cases consists of disk-shaped micron-sized particles made of Ti and V with an additional Fe contamination around the grain perimeter. The saturation magnetization typically increases with Fe concentration, however, there is no simple correlation between Fe content and magnetic moment. The saturation magnetization of one, respectively six, out of nine samples clearly exceeds the maximum contribution from pure Fe or Fe{sub 3}C. For most samples the temperature dependence of the remanence decreases linearly with T – a dependence found previously for defect-induced magnetism (DIM) in HOPG. We conclude that apart from magnetic impurities, additional contribution to the ferromagnetic magnetization exists in pristine HOPG in agreement with previous studies. A comparative study between the results of ion beam microscopy and the commonly used EDX analysis shows clearly that EDX is not a reliable method for quantitative trace elemental analysis in graphite, clarifying weaknesses and discrepancies in the element concentrations given in the recent literature.

36 MATERIALS SCIENCE↗