Mk-IV Salt Crystallization Hot Finger Apparatus for Partitioning Used Electrorefiner Salt

Electrorefining is a controlled redox process used to regulate the behavior of ionic species. Through this process, metals can be deposited onto a cathode from an electrolyte solution in a controlled manner. The Mk-IV electrorefiner (Mk-IV ER) at Idaho National Laboratory is an engineering-scale, molten salt-based electrorefining cell that has been used for decades to recover metallic uranium from spent fuel. As a result, highly stable fission product chlorides have accumulated in the electrolyte. This accumulation results in changes to the salt’s properties, such as melting temperature, thermal conductivity, and density, as well as elevated product impurity and fissile materials criticality margin. These factors prompt the need for a salt regeneration process, such as melt-crystallization and species drawdown. This work focuses on providing a conceptual design to regenerate ER salt from used Mk-IV-ER salt in-situ, while minimizing salt waste volumes by concentrating the fission products in a final processed salt heal. We propose using a hot-finger crystallization apparatus design to fractionally crystallize salt in the Mk-IV-ER head space (or baffle space), allowing the collection of solid and liquid fractions. By using a cup-drain design, the used salt will be allowed to slowly solidify on the walls of a stainless-steel cup. The apparatus drain plug will then open to allow the liquid salt phase to drain to a lower cup, effectively separating the liquid phase from the solid phase. Under the hypothesis that the liquid phase salt concentrates the fission products, which is under examination in the accompanying work package, this separation allows the recovered solid salt to be reused while minimizing the high-level salt waste volume of used ER salt.

36 - MATERIALS SCIENCE↗

AGR-5/6/7 Thermal Model with Non-uniform Gas Gaps

The daily as-run thermal analysis for the Advanced Gas Reactor (AGR)-5/6/7 experiment was documented in ECAR-5633 (Hawkes 2021). A finite element model was created for the entire test train, which consisted of five capsules. The fuel compacts, graphite holders, stainless-steel capsule walls, and all other major components were individually modeled, including all thermocouples (TCs). Daily heat rates for each compact and component in the model were input from daily as-run physics analyses. Daily gas compositions for each capsule were also input. The thermal conductivity of the compacts and graphite holders varied with fast neutron fluence. Gas mixture thermal conductivity was implemented using experimentally attained values from the literature. Fluence and temperature-dependent thermal conductivity was used for the graphite components and the fuel compacts. Radiation heat transfer was implemented. The model was tuned in an attempt to match the TC readings during the first cycle by adjusting the Neolube (graphite lubricant) thickness.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGR-5/6/7 Irradiation Experiment Fission Product Mass Balance

This report presents the fission product mass balance for the AGR-5/6/7 TRISO fuel irradiation experiment. The fission product inventories deposited on capsule components outside of the fuel (e.g., stainless-steel shells, graphite holders, Grafoil disks, and associated hardware) were quantified as part of the post-irradiation examination (PIE) to assess the performance of this fuel. Comparisons were made between these inventories and depletion calculations, non-destructive measurements of fuel fission product inventories in the intact fuel compacts, prior AGR experiments, and results from among each of the five distinct AGR-5/6/7 capsules. The data served as estimates of the condensable fission products released from the fuel during irradiation. Excluding Capsule 1 (which experienced accidental damage during irradiation) and Capsule 3 (which was tested at very high irradiation temperatures of >1300°C), the results indicate that the AGR-5/6/7 fuel performed comparably to fuel from earlier AGR experiments. The mass balance results were also used to estimate the number of particles with in-pile SiC failures. Subject to the assumptions made in these estimates, and excluding Capsules 1 and 3, the in-pile SiC failure rates for AGR-5/6/7 are comparable to those observed in AGR-2.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiolytic Gas Generation and Pressure Buildup in a Closed System Containing Mo-99 Solution

This study measured radiolytic gas generation and pressure buildup in a sealed stainless-steel system containing alkaline Mo-99 solution with added sodium nitrate as a hydrogen suppressant. In each of two experiments, approximately 200 Ci of Mo-99 solution was transferred into a closed experimental vessel inside a hot cell, isolated, and monitored for pressure rise caused by gas generation during radioactive decay. After pressure buildup, headspace gas samples were collected and analyzed by mass spectrometry to determine hydrogen and oxygen concentrations. The purpose was to quantify the magnitude of pressure buildup in a closed system and to characterize the gas composition produced by radiolysis of the Mo-99 target solution under representative handling and storage conditions. The two experiments used similar total Mo-99 activity but differed in solution volume, headspace volume, and leak integrity. In the first experiment, 197.5 Ci of Mo-99 in 16.92 mL of solution was loaded into a vessel with a 31.1-mL headspace; a small leak was later identified, and the measured peak pressure of 46 psig was extrapolated to about 70 psig in the absence of leakage. The headspace gas from this experiment contained about 21.4% H2 and 63.4% O2, but the composition was influenced by preferential hydrogen loss through the leak. In the second experiment, 193 Ci of Mo-99 in 5.41 mL of solution with 0.46 g NaNO3 was loaded into a vessel with a larger 42.61 mL headspace, and no detectable leak was observed. This experiment reached a peak pressure of 38 psig, and the measured gas composition was approximately 28.2% H2 and 51.5% O2. Because the second experiment was leak-free, it is considered the more reliable indicator of the true pressure buildup and intrinsic radiolytic gas composition of the Mo-99 solution.

Chemerisov, Sergey D.↗

Ultra-High Vacuum Outgassing Characterization of Thermally Processed Low-Carbon Steel for Advanced Particle Accelerator and Gravitational Wave Detector Applications

This dissertation investigated AISI 1020 low-carbon steel as an alternative vacuum chamber material to conventional stainless steel for ultra-high vacuum (UHV) and extreme-high vacuum (XHV) applications. After a 400 °C/48 h bake, AISI 1020 tube chambers achieved a hydrogen outgassing rate of 2.4 × 10¿¹6 Torr·L·s¿¹·cm¿², approximately 2,300 times lower than the prebaked 316L stainless-steel comparator, among the lowest hydrogen outgassing rates ever reported for an uncoated metallic vacuum chamber. Bare and magnetite-coated AISI 1020 chambers were then compared using throughput and rate-of-rise methods. The magnetite coating yielded 5× lower water outgassing at room temperature, but this advantage disappeared after 80 °C baking. After full thermal conditioning (400 °C/48 h prebake followed by 150 °C/96 h and 200 °C/110 h), bare steel achieved 25× lower hydrogen outgassing than the magnetite-coated chamber (9.6 × 10¿¹6 Torr·L·s¿¹·cm¿²) and >99% H2 purity with carbon species below RGA detection. Monte Carlo molecular flow simulations of a CEBAF photogun beamline (96 scenarios) showed that replacing 304L stainless steel with AISI 1020 reduces equilibrium H2 pressure by a factor of 833; a single 304L electrode contributes 98.8% of the gas load despite occupying only 9.1% of the internal surface area. A 500-m Einstein Telescope beampipe screening showed that corrugated bellows contribute 18% of the gas load from only 0.7% of the surface area. A five-model adsorption isotherm framework applied to 22 pumpdown datasets (164 fits with AR(1)-GLS correction) established that the experimental protocol, not the material, controls isotherm identifiability: Dubinin–Radushkevich wins isothermal pipe pumpdowns; Langmuir wins thermally dominated chamber bakes. Cross-dataset joint fitting of the AISI 1020 pipe pumpdowns yielded an H2 diffusion activation energy Ed = 7.24 ± 1.28 kcal·mol¿¹, consistent with trap dominated diffusion in commercial low-carbon steels. Two companion innovations were developed: a Variable Conductance Device (VCD, patent pending IDF-00723) for XHV outgassing measurement, and VacuumDesignerPro (VDP), a MATLAB-based design tool validated against LIGO benchmarks.

Al-Allaq, Aiman H [Old Dominion University]↗

Impact of Irradiation on Corrosion Performance of Hybrid Organic/Inorganic Coatings on Austenitic Stainless Steel

The effects of gamma radiation on the performance of two corrosion-resistant coatings applied to stainless-steel 304L (SS304L) surfaces are presented. Specifically, the ability of the coatings to mitigate corrosion of SS304L surfaces as a function of the dose received (0–1300 Mrad) and dose rate (176 compared to 1054 rad/s) is evaluated using electrochemical methods, spectroscopy, and microscopy. Coating A, an organic/inorganic hybrid coating consisting of a two-part silica ceramic component and a polymer linker was evaluated in comparison to Coating B, which utilized Coating A as a topcoat for a commercial, off-the-shelf, Zn-rich primer. Post irradiation, Coating A demonstrated some corrosion protection following exposure to low levels of gamma radiation, but coating degradation occurred with an increased exposure dose and resulted in isolated regions of corrosion initiation. For Coating B, greater corrosion resistance was observed compared to Coating A due to the sacrificial nature of the Zn at elevated doses of gamma radiation. No effect of the dose rate (for the single dose examined) was observed for either coating. It is proposed for Coating B that as the polymer coating thermally degrades above 250 °C (bond scission of the polymer occurs), the remaining Zinc layer adhered to the SS304L post-irradiation enables enhanced corrosion resistance as compared to Coating A, which displays solely polymer degradation. The results presented herein establish an understanding of coating behavior with radiation exposure, specifically the relationship between corrosion coating performance and radiation dose, and can inform ageing and lifetime management for various applications.

degradation↗

Effect of sintering temperature on adhesion of spray-on piezoelectric transducers

Conventionally sol-gel spray-on transducers require a high-temperature (> 700 ◦C) sintering process; however, this process can affect the microstructure of the substrate material. For mechanical elbows and valves utilized for fluid transport in the energy sector, the components are designed to have a specific microstructure, and deviations from these specifications can create weak points in the system. For this reason it is important to investigate how the temperature of the deposition process affects the substrate. This paper investigates the effect of high-temperature and low-temperature (< 150 ◦C) processing conditions on the surface composition of the substrate. Furthermore, the resultant transducers from high- and low-temperature fabrication processes are compared to determine if a low-temperature processing method is feasible. For these studies a sol-gel spray-on process is employed to deposit piezoelectric ceramics onto a stainless-steel 316L substrate. Energy-dispersive X-ray spectroscopy is utilized to determine the composition of the substrate surface before and after transducer deposition. Results indicate that the high-temperature processing conditions may alter the surface composition of the metal due to a diffusion of the metal into the ceramic, which results in a metal surface that is bonded to the ceramic. Furthermore, it is shown that low-temperature processing of spray-on transducers is a viable method for transducer fabrication where the resultant transducers meet the industry minimum requirement of 30 dB signalto-noise ratio. In parallel simulation calculations, finite-element method (FEM) studies were performed to model the adhesive strength of the low-temperature processed transducer to the substrate surface. Comparisons between the simulations and experiments suggest that the bond strength is much greater than the commercial gel bonds and closer to hardened epoxy glue bonds. These results indicate that spray-on transducers fabricated under lowtemperature processing conditions are a viable solution for leave-in-place monitoring of structures.

M. Sinding, Kyle↗

The Effects of Some Surface Irregularities on Wing Drag

The N.A.C.A. has conducted tests to provide more complete data than were previously available for estimating the effects of common surface irregularities on wing drag. The irregularities investigated included: brazier-head and countersunk rivets, spot welds, several types of sheet-metal joints, and surface roughness. Tests were also conducted to determine the over-all effect of manufacturing irregularities incidental to riveted aluminum alloy and to spot-welded stainless-steel construction. The tests were made in the 8-foot high speed wind tunnel at Reynolds Numbers up to 18,000,000. The results show that any of the surface irregularities investigated may increase wing drag enough to have important adverse effects on high-speed performance and economy. A method of estimating increases in wing drag caused by brazier-head rivets and lapped joints under conditions outside the range of the tests is suggested. Estimated drag increases due to rivets and lapped joints under conditions outside the range of the tests is suggested. Estimated drag increases due to rivets and lapped joints on a wing of 20-foot chord flying at 250 miles per hour are shown.

Drag, Manley↗

Relief of Residual Stress in Streamline Tie Rods by Heat Treatment

About two-thirds of the residual stress in cold-worked SAE 1050 steel tie rods was relieved by heating 30 minutes at 600 degrees Fahrenheit. Cold-worked austenitic stainless-steel tie rods could be heated at temperatures up to 1000 degrees Fahrenheit without lowering the important physical properties. The corrosion resistance, in laboratory corrosion test, of straight 18:8 and titanium-treated 18:8 materials appeared to be impaired after heating at temperatures above 800 degrees or 900 degrees fahrenheit. Columbium-treated and molybdenum-treated 18:8 steel exhibited improved stability over a wide range of temperatures. Tie rods of either material could be heated 30 minutes with safety at any temperature up to 1000 degrees Fahrenheit. At this temperature most of the residual stress would be relieved.

Pollard, R E↗

Description of stress-strain curves by three parameters

A simple formula is suggested for describing the stress-strain curve in terms of three parameters; namely, Young's modulus and two secant yield strengths. Dimensionless charts are derived from this formula for determining the stress-strain curve, the tangent modulus, and the reduced modulus of a material for which these three parameters are given. Comparison with the tensile and compressive data on aluminum-alloy, stainless-steel, and carbon-steel sheet in NACA Technical Note No. 840 indicates that the formula is adequate for most of these materials. The formula does not describe the behavior of alclad sheet, which shows a marked change in slope at low stress. It seems probable that more than three parameters will be necessary to represent such stress-strain curves adequately.

Ramberg, Walter↗

Poisson's Ratios and Volume Changes for Plastically Orthotropic Material

Measurements of Poisson's ratios have been made in three orthogonal directions on aluminum alloy blocks in compression and on stainless-steel sheet in both tension and compression. These measurements, as well as those obtained by density determinations, show that there is no permanent plastic change in volume within the accuracy of observation. A method is suggested whereby a correlation may be effected between the measured individual values of the Poisson's ratios and the stress-strain curves for the material. Allowance must be made for the difference in the stress-strain in tension and compression; this difference, wherever it appears, is accompanied by significant changes in the Poisson's ratios.

Stowell, Elbridge Z↗

A Study of the Efficiency of High-strength, Steel, Cellular-core Sandwich Plates in Compression

Structural efficiency curves are presented for high-strength, stainless-steel, cellular-core sandwich plates of various proportions subjected to compressive end loads for temperatures of 80 F and 600 F. Optimum proportions of sandwich plates for any value of the compressive loading intensity can be determined from the curves. The efficiency of steel sandwich plates of optimum proportions is compared with the efficiency of solid plates of high-strength steel and aluminum and titanium alloys at the two temperatures.

SANDWICH AND LAMINATES↗

The Combinations of Thermal and Load Stresses for the Onset of Permanent Buckling in Plates

A simple and practical method for evaluating the onset of permanent buckling in plates in the presence of combined thermal and compressive load stresses is outlined. A particular application of the method shows reasonable agreement with tests of 17-7 PH stainless-steel square tubes. The results indicate that the compressive load stress which the plate can support at the onset of permanent buckling is substantially reduced as the temperature difference of the plate and adjoining members increases.

LOADS AND STRESSES, STRUCTURAL - COMPRESSION↗

Wire Cloth as Porous Material for Transpiration-cooled Walls

The permeability characteristics and tensile strength of a porous material developed from stainless-steel corduroy wire cloth for use in transpiration-cooled walls where the primary stresses are in one direction were investigated. The results of this investigation are presented and compared with similar results obtained with porous sintered metal compacts. A much wider range of permeabilities is obtainable with the wire cloth than with the porous metal compacts considered and the ultimate tensile strength in the direction of the primary stresses for porous materials produced from three mesh sizes of wire cloth are from two to three times the ultimate tensile strengths of the porous metal compacts.

MATERIALS - TYPES↗

Endurance Evaluation of Sintered, Porous, Strut-Supported Turbine Blades made by Federal-Mogul-Bower-Bearings, Incorporated, under Bureau of Aeronautics Contract NOas 55-124-C

Four strut-supported, transpiration-cooled turbine blades were investigated experimentally in a turbojet engine. The blade shells were fabricated by the mold-sintering method with spherical stainless-steel powder. Two blades were investigated in order to evolve suitable capping methods for the blade tip. Two other blades were used to evaluate the durability of the porous-shell material. The blades were investigated at a turbine-tip speed of 1305 feet per second, an average turbine-inlet temperature of about 1670 F, and at a porous-shell temperature limited to a maximum of approximately 1040 F.

Hickel, Robert O.↗

Determining Drying Conditions to Mitigate Hanford Transfer Line Corrosion

Radioactive waste is stored in underground, carbon-steel double-shell tanks at the Department of Energy Hanford site.1,2,3 The underground transfer lines are used to transfer the waste between the tanks and other assets at the Hanford tank farm facilities. The transfer lines constructed before 1990 are pipe-in-pipe design with most of the lines having carbon steel carrier pipe and carbon steel encasements. The lines constructed after 1990 have a stainless-steel carrier with a carbon steel encasement. The carrier lines, which are in contact with the waste, provide a critical confinement function, while the encasements provide secondary containment to reduce the risk of a release and contamination to the environment. In 2022, a visual inspection of the annulus between the encasement and the carrier for one of the pre-1990 transfer lines revealed standing liquid in contact with the carrier pipe. Additionally, a significant build-up of corrosion products on the exterior of the carrier pipe and the interior of the encasement pipe was observed. To assess the extent of condition, borescope inspections were performed in the encasement space of additional transfer lines in the facility to provide a baseline. The inspection revealed that of the lines inspected, 29 had either moisture present or evidence that moisture had been present in the past (e.g., waterline corrosion where the pipe had been exposed to standing water). Additional inspections indicated several instances of pitting corrosion on the interior of the encasement and exterior the carrier transfer lines. An image of the carrier pipe with several pits is presented in Figure 1(a) and the profiled image of the transfer line section along with the pit depths are presented Figure 1(b). As seen in the figure, the deepest pit was 73 mils on the pipe section. These lines were designated as “do-not-use” until further compensatory actions are implemented to return the lines to service.

Shukla, Pavan K. [Savannah River National Laborato↗

Modeling a Sodium Heat Pipe Experiment at SPHERE Using Sockeye

The Single Primary Heat Extraction and Rejection Emulator (SPHERE) facility at Idaho Na- tional Laboratory was recently utilized to generate data for the startup and steady operation of a high-performance, sodium heat pipe over the course of 1000 hours, as a test of detrimental, long-term effects of heat pipe operation. The setup consists of a single, sodium heat pipe enclosed in a stainless-steel vacuum chamber, heated radiatively via a cylindrical ceramic fiber heater configuration and cooled via a water-cooled calorimeter. Measurements include temperatures at several axial locations along the outer surface of the heat pipe, the power provided to the heaters, and the heat removal rate of the calorimeter. In this work, this data is utilized to validate heat pipe models in the heat pipe application Sockeye, which is based upon the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. Sockeye provides various heat pipe models at an engineering scale appropriate for the multiphysics simulation of microreactors, which may feature several hundred heat pipes. This work details models of this experiment in SPHERE using various heat pipe models with Sockeye, including heat conduction-based models and compressible flow models of the heat pipe interior. These models are compared to the experimental data to assess the accuracy of several aspects of heat pipe modeling, including frozen startup, the effect of non-condensable gases, and the coupling of the heat pipe to its environment.

97 - MATHEMATICS AND COMPUTING↗

Modeling a Sodium Heat Pipe Experiment at SPHERE Using Sockeye

The Single Primary Heat Extraction and Rejection Emulator (SPHERE) facility at Idaho National Laboratory was recently utilized to generate data for the startup and steady operation of a high-performance, sodium heat pipe over the course of 1,000 hours to test the detrimental, long-term effects of heat pipe operation. The setup consisted of a single, sodium heat pipe enclosed in a stainless-steel vacuum chamber, heated radiatively via a cylindrical ceramic-fiber heater configuration and cooled via a water-cooled calorimeter. Measurements included temperatures at several axial locations along the outer surface of the heat pipe, the power provided to the heaters, and the heat removal rate of the calorimeter. In this work, we use this data to validate heat pipe models in Sockeye, a heat pipe application based on the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. Sockeye provides various heat pipe models at an engineering scale appropriate for the multiphysics simulation of microreactors, which may feature several hundred heat pipes. This work details models of this experiment at SPHERE using various heat pipe models with Sockeye, including heat-conduction-based and compressible flow models of the heat pipe interior.

97 - MATHEMATICS AND COMPUTING↗