Search NASA⌕ Search

SEARCH · Search NASA

Results for “start”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Interaction between the PH and START domains of ceramide transfer protein competes with phosphatidylinositol 4-phosphate binding by the PH domain

De novo synthesis of the sphingolipid sphingomyelin requires non-vesicular transport of ceramide from the endoplasmic reticulum to the Golgi by the multidomain protein ceramide transfer protein (CERT). CERT's N-terminal pleckstrin homology (PH) domain targets it to the Golgi by binding to phosphatidylinositol 4-phosphate (PtdIns(4)P) in the Golgi membrane, whereas its C-terminal StAR-related lipid transfer domain (START) carries out ceramide transfer. Hyperphosphorylation of a serine-rich motif immediately after the PH domain decreases both PtdIns(4)P binding and ceramide transfer by CERT. This down-regulation requires both the PH and START domains, suggesting a possible inhibitory interaction between the two domains. In this study we show that isolated PH and START domains interact with each other. The crystal structure of a PH–START complex revealed that the START domain binds to the PH domain at the same site for PtdIns(4)P-binding, suggesting that the START domain competes with PtdIns(4)P for association with the PH domain. We further report that mutations disrupting the PH–START interaction increase both PtdIns(4)P-binding affinity and ceramide transfer activity of a CERT-serine–rich phosphorylation mimic. We also found that these mutations increase the Golgi localization of CERT inside the cell, consistent with enhanced PtdIns(4)P binding of the mutant. Collectively, our structural, biochemical, and cellular investigations provide important structural insight into the regulation of CERT function and localization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stop and Restart Effects on Modern Vehicle Starting System Components

Many drivers of personal and commercial vehicles believe that turning the vehicle off and on frequently instead of idling will cause premature wear of the starter system (starter motor and starter battery). As a result, they are concerned that the replacement cost of the starter motor and/or battery due to increased manual engine cycling would be more than the cumulative cost of the fuel saved by not idling unnecessarily. A number of variables play a role in addressing this complex concern, including the number of starting cycles per day, the time between starting cycles, the intended design life of the starting system, the amount of fuel used to restart an engine, and the cumulative cost of the saved fuel. Qualitative and quantitative information from a variety of sources was used to develop a life-cycle economic model to evaluate the cost and quantify the realistic factors that are related to the permissible frequency of starter motor cycles for the average vehicle to economically minimize engine idle time. Annual cost savings can be calculated depending on shutdown duration and the number of shutdown cycles per day. Analysis shows that cost savings are realized by eliminating idling exceeding one minute by shutting down the engine and restarting it. For a typical motorist, the damage to starting system components resulting from additional daily start cycles will be negligible. Overall, it was found that starter life is mostly dependent on the total number of start cycles, while battery life is more dependent on ensuring a full charge between start events.

42 ENGINEERING↗

Development of a Cold Start Fuel Penalty Metric for Evaluating the Impact of Fuel Composition Changes on SI Engine Emissions Control

The U.S. Department of Energy’s Co-Optimization of Fuels and Engines initiative (Co-Optima) aims to simultaneously transform both transportation fuels and engines to maximize performance and energy efficiency. Researchers from across the DOE national laboratories are working within Co-Optima to develop merit functions for evaluating the impact of fuel formulations on the performance of advanced engines. The merit functions relate overall engine efficiency to specific measurable fuel properties and will serve as key tools in the fuel/engine co-optimization process. This work focused on developing a term for the Co-Optima light-duty boosted spark ignition (SI) engine merit function that captures the effects of fuel composition on emissions control system performance. For stoichiometric light-duty SI engines, the majority of NOx, NMOG, and CO emissions occur during cold start, before the three-way catalyst (TWC) has reached its “light-off” temperature. This light-off temperature depends on the exhaust composition, which changes with fuel formulation. Thus, the time to achieve light-off, and therefore the cold start emissions, depends on fuel composition. Since the time to reach light-off must be minimized to meet emissions regulations, modern vehicles employ cold start strategies that intentionally release fuel energy into the engine exhaust to heat the TWC above the light-off temperature as quickly as possible. The fuel penalty associated with catalyst heating during cold start provides a link between fuel properties, emissions performance, and engine efficiency. This paper describes the derivation of the Co-Optima SI engine merit function term for emissions control, which is based on the cold start fuel penalty for catalyst heating and the catalytic light-off temperature for a particular fuel composition. It also discusses the process used for extracting cold start fuel penalties from chassis dynamometer data sets previously collected at ORNL. The form of the merit function term is simple, but it is only intended as a starting point for comparing the potential impacts of changes in fuel formulation on emissions control system performance.

Pihl, Josh↗

Start-up Behavior of a Miniature Loop Heat Pipe with Multiple Evaporators and Multiple Condensers

This paper presents the test results on start-up behaviors of a miniature loop heat pipe (MLHP) with two evaporators and two condensers. The MLHP start-up tests were conducted by varying the heat load to one or both evaporators, the condenser sink temperatures, and with or without compensation chamber (CC) temperature control. More than 90 start-up tests have been conducted in horizontal position, and all were successful. Test results showed robust start-ups of the MLHP with heat loads of 1W to 100W. Loop started as soon as the heat load was applied, without a large temperature overshoot. The efficacy and good repeatability of the start-ups with CC active temperature control by using thermoelectric cooler (TEC) was demonstrated. The ability of the loop to start with parasitic heat gain caused by cooling the CC temperature below ambient temperature was also demonstrated.

Nagano, Hosei↗

An infeasible-start framework for convex quadratic optimization, with application to constraint-reduced interior-point and other methods

A framework is proposed for solving general convex quadratic programs (CQPs) from an infeasible starting point by invoking an existing feasible-start algorithm tailored for inequality-constrained CQPs. The central tool is an exact penalty function scheme equipped with a penalty-parameter updating rule. The feasible-start algorithm merely has to satisfy certain general requirements, and so is the updating rule. Under mild assumptions, the framework is proved to converge on CQPs with both inequality and equality constraints and, at a negligible additional cost per iteration, produces an infeasibility certificate, together with a feasible point for an (approximately) ℓ 1 -least relaxed feasible problem, when the given problem does not have a feasible solution. The framework is applied to a feasible-start constraint-reduced interior-point algorithm previously proved to be highly performant on problems with many more inequality constraints than variables (“imbalanced”). Numerical comparison with popular codes (OSQP, qpOASES, MOSEK) is reported on both randomly generated problems and support-vector machine classifier training problems. The results show that the former typically outperforms the latter on imbalanced problems. Finally, application of the proposed infeasible-start framework to other feasible-start algorithms is briefly considered, and is tested on a simplex iteration.

97 MATHEMATICS AND COMPUTING↗

Comparison of plasma start-up with high Z and low Z first wall in WEST

The choice of first wall material is of paramount importance for the plasma start-up conditions in ITER and future fusion power plants. In this context, the present work focuses on the correlations between first wall impurity sources and total radiated power during plasma start-up in the tungsten (W) Environment in Steady-state Tokamak (WEST). The objective is to highlight experimental indications for a preferable combination of start-up plasma scenario and first wall materials. Until 2019, WEST featured a full high Z first wall with all limiters exposing only W surfaces to the plasma. To study the impact of a low Z first wall in WEST, boron nitride tiles were installed in the central part of the inner and outer limiters in 2020. Although visible spectroscopy and bolometry measurements show respectively a strong weakening of the WI line intensity on the limiters and a reduction of radiated power after the changeover, a degradation occurs with the accumulation of plasma exposure. In addition, the different plasma facing elements of the main chamber do not influence equally the radiated power during start-up. In both high Z and low Z environments, a clear non-linear dependence is found between the start-up radiated power and the outer limiter W impurity source. Since W seems to be the main cause for core radiation, correlation between outer limiter W sources and other impurity sources are investigated. Finally, analysis of the legacy of B powder drops on a number of start-up plasmas suggests that it is less effective at reducing radiated power when the first wall is covered with W.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resilient Inverter-Driven Black Start with Collective Parallel Grid-Forming Operation

As modern power systems are experiencing exceptional changes with increasing penetrations of inverter-based resources (IBRs), system restoration using IBRs has received attention. Using local grid-forming (GFM) assets near consumers, engineered to establish grid voltages in the absence of a stiff grid, i.e., bottom-up restoration, a distribution system could obtain high system resilience by not relying on the bulk power system restoration, which requires significant human intervention and procedure. This paper studies the technical feasibility of the novel approach with detailed electromagnetic transient (EMT) simulations. To thoroughly evaluate the potential of GFM inverters and the technical challenges in IBR-driven black start, a detailed three-phase inverter model is developed, including negative-sequence control for voltage balance and a phase-by- phase current limiter to sustain momentary overloading during the black start. To examine dynamic aspects of the black-start process, the EMT simulation also models transformer and motor dynamics to emulate their inrush and startup behaviors as well as network dynamics. In addition, active involvement of grid- following distributed energy resources is also studied to facilitate the black-start process. By allowing multiple GFM inverters to collectively black start without leader-follower coordination, we demonstrate that a system can achieve high resilience even with a fraction of assets lost. Two test cases of inverter-driven black start, using two and one GFM inverters, respectively, for a heavily unbalanced 2-MVA distribution feeder are demonstrated. Takeaways for further study and field deployment are provided.

grid-forming inverter↗

Black Start of Unbalanced Microgrids Harmonizing Single- and Three-Phase Grid-Forming Inverters

As power systems are transforming with increasing penetrations of inverter-based resources (IBRs), system restoration using IBRs has drawn attention. Using distributed grid-forming (GFM) assets located near critical loads, either three-phase or single-phase, to establish microgrid voltages in the absence of a bulk grid, a distribution system could obtain high system survivability. For swift and secure recovery of a critical load in a single-phase lateral, local single-phase GFM inverters can form a microgrid, and then it can be combined with a neighbouring grid with the inverters remaining in GFM mode for voltage and frequency regulation until the bulk grid comes online. It leads to dynamic interoperation of single-phase GFM inverters with three-phase ones in the black start process. This paper studies the novel approach with electromagnetic transient (EMT) simulations. To evaluate the potential and the technical challenges of the heterogeneous IBR-driven black start, three-phase and single-phase GFM inverter models are developed, including negative-sequence control for voltage balance and a phase-by-phase current limiter (three-phase) and current magnitude limiter (single-phase). To examine dynamic aspects of the black-start process, the EMT simulation also models transformer and motor dynamics emulating their inrush and startup behavior as well as network dynamics. Involvement of grid-following assets to facilitate the black-start process is also modeled. By allowing multiple GFM inverters to collectively black start without leader-follower coordination, regardless of phases, a system can achieve extreme resilience. An inverter-driven black start of a heavily unbalanced 2-MVA distribution feeder using 1 three-phase and 3 single-phase GFM inverters is demonstrated. The simulation shows the heterogeneous system can maintain stability with the single-phase GFM dynamics coupled with the three-phase one.

grid-forming inverter↗

Black Start of Unbalanced Microgrids Harmonizing Single- and Three-Phase Grid-Forming Inverters: Preprint

As power systems are transforming with increasing penetrations of inverter-based resources (IBRs), system restoration using IBRs has drawn attention. Using distributed grid-forming (GFM) assets located near critical loads, either three-phase or single-phase, to establish microgrid voltages in the absence of a bulk grid, a distribution system could obtain high system survivability. For swift and secure recovery of a critical load in a single-phase lateral, local single-phase GFM inverters can form a microgrid, and then it can be combined with a neighbouring grid with the inverters remaining in GFM mode for voltage and frequency regulation until the bulk grid comes online. It leads to dynamic interoperation of single-phase GFM inverters with three-phase ones in the black start process. This paper studies the novel approach with electromagnetic transient (EMT) simulations. To evaluate the potential and the technical challenges of the heterogeneous IBR-driven black start, three-phase and single-phase GFM inverter models are developed, including negative-sequence control for voltage balance and a phase-by-phase current limiter (three-phase) and current magnitude limiter (single-phase). To examine dynamic aspects of the black-start process, the EMT simulation also models transformer and motor dynamics emulating their inrush and startup behavior as well as network dynamics. Involvement of grid-following assets to facilitate the black-start process is also modeled. By allowing multiple GFM inverters to collectively black start without leader-follower coordination, regardless of phases, a system can achieve extreme resilience. An inverter-driven black start of a heavily unbalanced 2-MVA distribution feeder using 1 three-phase and 3 single-phase GFM inverters is demonstrated. The simulation shows the heterogeneous system can maintain stability with the single-phase GFM dynamics coupled with the three-phase one.

grid-forming inverter↗

Survival and Age at Maturity in Head-Started Wood Turtles ( Glyptemys insculpta ) with Implications for Population Recovery

A small relict population of Glyptemys insculpta (Wood Turtle) was discovered on a protected area in New Jersey in 2006. Marking and radio-tracking of the old founder individuals helped to determine movement patterns and habitat use. Monitoring of nesting females revealed that nesting habitat and nest success was limited due to invasive plants, human landscape alteration, and Procyon lotor (Raccoon) depredation. We initiated habitat restoration including creation of protected nesting areas, mowing in winter, invasive plant removal, and adjacent landowner education. Here, we direct-released hatchlings from protected nests from 2006 to 2015, yet only a few were detected in subsequent years. Between 2011 and 2023, some or all of each hatchling cohort were head-started indoors at a high school for 9 months. We have continuously radio-tracked all head-starts from the 2011 cohort and portions of the 2012–2014 cohorts. Head-started turtles found their own food, established home ranges, and hibernated communally with founder adults. Subsidized Raccoons, mowers, automobiles, and flooding events—all human-instigated—were the causes of mortality. The first males and first females from the 2011 head-start cohort reached maturity in 2017 and 2019, respectively, at ages 6–8, younger than expected by 4–5 years. Successful reproduction by head-starts was confirmed by viable hatchlings produced in 2019, 2020, and 2023. Head-starting can pull a relict population out of the nose-dive to extirpation when used in conjunction with habitat-restoration practices, but it must be conducted with persistence and continuity over at least the number of years it takes for the earliest cohorts to reach maturity and begin producing offspring of their own.

59 BASIC BIOLOGICAL SCIENCES↗

Smart Building Start (SBS) (CRADA 480)

The idea of Smart Building Start (SBS) is to manage the on/off scheduling of HVAC equipment in buildings in an optimal way in order to achieve comfort conditions at the designated times with the minimal use of energy. This concept is also known as Optimal Start and it has typically been used in buildings to start up equipment based on predictions made for a representative (or average) zone in a building. This means that zones that could have waited longer to receive conditioned air are activated too early leading to unnecessary energy loss. The approach proposed in this project is to develop and implement a distributed version of optimal start that will consider the individual requirements of all treated zones. The developed control strategy will enable smart start of the central plant as well as further localized control over each individual zone by means of setpoint adjustment so that zones are not conditioned too early thereby reducing energy use compared to the current state of the art. This project is a collaboration between PNNL and Verdicity with the goal being to bring the research concept of SBS to commercialization. The SBS algorithm(s) will be implemented and hosted on the PNNL-developed open-platform VOLTTRON which will accelerate bringing the research to practice. It is anticipated that this project will lead to new IP surrounding the algorithm and its decentralized deployment. The project will also further demonstrate the success of VOLTRON as a flexible platform for implementation of innovative algorithms for improving energy efficiency in buildings. Previous studies on smart building start carried out by PNNL have indicated potential energy savings on the order of 10-15% for multi-zone buildings compared to conventional strategies. Verdicity currently has a number of customers who can benefit from the use of this technology. PNNL will work with Verdicity to identify any key gaps in the integrated software and jointly work to enhance and customize it for Verdicity and to integrate it with their existing products for use at their customers’ sites. The proposed work will help previously funded Federal research and development technology investments find their way into a viable commercial market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of China Experimental Fast Reactor Start-up Tests (Final Report, Revision 1)

This report documents the results and observations on the Coordinated Research Project (CRP) of the International Atomic Energy Agency (IAEA) on “Neutronics Benchmark of CEFR Start-Up Tests.” The China Experimental Fast Reactor (CEFR) is a 65MWt sodium-cooled fast reactor with highly enriched uranium oxide fuel. The reactor achieved first criticality in 2010, and a series of start-up tests were conducted to measure various reactor physics parameters. In 2018, the IAEA launched the CRP for validation and qualification of member states' computation capabilities in the field of fast reactor simulation by utilizing the measured data in the CEFR start-up test. Twenty-nine international organizations from eighteen member countries, including Argonne National Laboratory, have participated in the CRP. The CEFR start-up tests offer a rare opportunity to validate U.S. nuclear engineering software because it is a well-specified benchmark with corresponding measurements for a recently built fast reactor starting up with a known fuel composition (fresh fuel). Previous fast reactor validation benchmarks frequently involve reactors that have already been started up and contain irradiated fuel that is difficult to characterize with high certainty.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effect of Split-Injection Strategies on Engine Performance and Emissions under Cold-Start Operation

The recently concluded partnership for advancing combustion engines (PACE) was a US Department of Energy consortium involving multiple national laboratories focused on addressing key efficiency and emission barriers in light-duty engines. Generation of detailed experimental data and modeling capabilities to understand and predict cold-start behavior was a major pillar in this program. Cold-start, as defined by the time between first engine crank and three-way catalyst light-off, is responsible for a large percentage of NOx, unburned hydrocarbon, and particulate matter emissions in light-duty engines. Minimizing emissions during cold-start is a trade-off between achieving faster three-way catalyst light-off, and engine out emissions during that period. In this study, engine performance, emissions, and catalyst warmup potential were monitored while the engine was operated using a single direct injection (baseline case) as well as a two-way-equal-split direct injection strategy. These injection strategies were analyzed at a range of cold-start-operation relevant retarded spark timings of up to 25 degrees after top dead center of firing (dATDCf). A stoichiometric 2-bar NIMEP steady-state condition was used for all cases to simulate cold-start operation. Significant improvement in engine stability was observed with the two-way-split injection strategy at the retarded spark timings allowing for up to 2.5x increase in exhaust heat rate when engine operation is stability constrained. Similar fuel-loss-to-oil trends with exhaust heat rate were observed for both single and two-way-split injection strategies. However, the two-way split injection was observed to produce higher NOx emissions per unit exhaust heat rate. A single data point run with three-way-split direct injection at a very retarded spark-timing of 30 dATDCf pointed to further improvements in engine stability and reduction in fuel-loss-to-oil as compared to single injection strategy. Engine stability decreased as spark timing was initially retarded with a single injection but was observed to plateau and stabilize beyond spark timing of 10 dATDCf. Finally, for the two-way-split-injection strategy, retarding the start of injection (SOI) timing of the second injection led to a decrease in engine stability as well as an increase in soot emissions.

42 ENGINEERING↗

A parametric study of motor starting for a 2- to 10-kilowatt Brayton power system

A study of the motor starting of a Brayton cycle power system was conducted to provide estimates of system sensitivity to several controllable parameters. These sensitivity estimates were used as a basis for selection of an optimum motor-start scheme to be implemented on the 2- to 10-kilowatt Brayton power system designed and presently under test. The studies were conducted with an analog simulation of the Brayton power system and covered a range of frequencies from 400 Hz (33 percent design) to 1200 Hz (design), voltage-to-frequency ratios of 0.050 (50 percent design) to 0.100 (design), turbine-inlet temperatures of 800 K (1440 R, 70 percent design) to 1140 K (2060 deg R, design), and prestart pressure levels of 14.5 psia to 29.0 psia. These studies have shown the effect of selected system variables on motor starting. The final selection of motor-start variables can therefore be made on the basis of motor-start inverter complexity, battery size and weight, desired steady-state pressure level after startup, and other operational limitations. In general, the study showed the time required for motor starting to be inversely proportional to motor frequency, voltage, turbine-inlet temperature, and pressure level. An increase in any of these parameters decreases startup time.

Cantoni, D. A.↗

Arcjet starting reliability: A multistart test on hydrogen/nitrogen mixtures

An arcjet starting reliability test was performed to investigate one feasibility issue in the use of arcjets onboard a satellite for north-south stationkeeping. A 1 kW arcjet was run on hydrogen/nitrogen gas mixtures simulating decomposed hydrazine. A pulse width modulated power supply with an integral high voltage starting pulser was used for arc ignition and steady-state operation. The test was performed in four phases in order to determine if starting characteristics changed as a result of long term thruster operation. More than 300 successful starts were accumulated over an operating time of 18 hrs. Overall results indicate that there is a link between starting characteristics and long term thruster operation; however, the large number of starts had no effect on steady-state performance.

Haag, Thomas W.↗

Arcjet starting reliability - A multistart test on hydrogen/nitrogen mixtures

An arcjet starting reliability test was performed to investigate one feasibility issue in the use of arcjets on board a satellite for north-south stationkeeping. A 1 kW arcjet was run on hydrogen/nitrogen gas mixtures simulating decomposed hydrazine. A pulse width modulated power supply with an integral high voltage starting pulser was used for arc ignition and steady-state operation. The test was performed in four phases in order to determine if starting characteristics changed as a result of long term thruster operation. More than 300 successful starts were accumulated over an operating time of 18 hr. Overall results indicate that there is a link between starting characteristics and long term thruster operation; however, the large number of starts had no effect on steady-state performance.

Haag, Thomas W.↗

Magnification of starting torques of dc motors by maximum power point trackers in photovoltaic systems

Direct current (dc) motors are used in terrestrial photovoltaic (PV) systems such as in water-pumping systems for irrigation and water supply. Direct current motors may also be used for space applications. Simple and low weight systems including dc motors may be of special interest in space where the motors are directly coupled to the solar cell array (with no storage). The system will operate only during times when sufficient insolation is available. An important performance characteristic of electric motors is the starting to rated torque ratio. Different types of dc motors have different starting torque ratios. These ratios are dictated by the size of solar cell array, and the developed motor torque may not be sufficient to overcome the load starting torque. By including a maximum power point tracker (MPPT) in the PV system, the starting to rated torque ratio will increase, the amount of which depends on the motor type. The starting torque ratio is calculated for the permanent magnet, series and shunt excited dc motors when powered by solar cell arrays for two cases: with and without MPPT's. Defining a motor torque magnification by the ratio of the motor torque with an MPPT to the motor torque without an MPPT, a magnification of 3 was obtained for the permanent magnet motor and a magnification of 7 for both the series and shunt motors. The effect of the variation of solar insolation on the motor starting torque was covered. All motor types are less sensitive to insolation variation in systems including MPPT's as compared to systems with MPPT's. The analysis of this paper will assist the PV system designed to determine whether or not to include an MPPT in the system for a specific motor type.

Appelbaum, Joseph↗

Start-On-The-Part Transient Model for In-Situ Automated Tape Placement of Thermoplastic Composites

Fabrication of a complex part by automated tape placement (ATP) can require starting up a new tape-end in the part interior, termed start-on-the-part. Careful thermal management of the starting transient is needed to achieve uniform crystallinity and inter-laminar weld strength - which is the objective of this modeling effort. The transient is modeled by a Fourier-Laplace transform solution of the time-dependent thermal transport equation in two spatial dimensions. The solution is subject to a quasi-steady approximation for the speed and length of the consolidation head. Sample calculations are done for the Langley ATP robot applying PEEK/carbon fiber composite and for two upgrades in robot performance. The head starts out almost at rest which meets an engineering requirement for accurate placement of the new tape-end. The head then rapidly accelerates until it reaches its steady state speed. This rapid acceleration, however, violates the quasi-steady approximation, so uniform weld strength and crystallinity during the starting transient are not actually achieved. The solution does give the elapsed time and distance from start-up to validity of the quasi-steady approximation - which quantifies the length of the non-uniform region. The elapsed time was always less than 0.1 s and the elapsed distance less than 1 cm. This quantification would allow the non-uniform region to be either trimmed away or compensated for in the design of a part. Such compensation would require experiments to measure the degree of non-uniformity, because the solution does not provide this information. The rapid acceleration suggests that the consolidation roller or belt be actively synchronized to avoid abrading the tape.

Costen, Robert c.↗