Search NASA⌕ Search

SEARCH · Search NASA

Results for “statistical comparison”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Use of vision and sound to classify feller-buncher operational state

Productivity measures in logging involve simultaneous recognition and classification of event occurrence and timing, and the volume of stems being handled. In full-tree felling systems these measurements are difficult to implement in an autonomous manner because of the unfavorable working environment and the abundance of confounding extraneous events. This paper proposed a vision method that used a lowcost camera to recognize feller-buncher operational events including tree cutting and piling. It used a fine K-nearest neighbors (fKNN) algorithm as the final classifier based on both audio and video features derived from short video segments as inputs. The classifier’s calibration accuracy exceeds 94%. The trained model was tested on videos recorded under various conditions. The overall accurate rates for short segments were greater than 89%. Comparisons were made between the human- and algorithm derived event detection rates, events’ durations, and inter-event timing using continuously recorded videos taken during feller operation. Video results between the fKNN model and manual observation were similar. Statistical comparison using the Kolmogorov–Smirnov test to evaluate measured parameters’ distributions (manual versus automated event duration and inter-event timing) did not show significant differences with the lowest P-value among all Kolmogorov–Smirnov tests equal to 0.12. Here the result indicated the feasibility and potential of using the method for the automatic time study of drive-to-tree feller bunchers.

97 MATHEMATICS AND COMPUTING↗

THE DIFFERENT EVOLUTION OF GAS AND DUST IN DISKS AROUND SUN-LIKE AND COOL STARS

Planet formation is profoundly impacted by the properties of protoplanetary disks and their central star. However, how disk properties vary with stellar parameters remains poorly known. Here, we present the first comprehensive, comparative Spitzer/IRS study of the dust and gas properties of disks around young Sun-like stars (K1-M5) and cool stars/brown dwarfs (M5-M9). The comparison of these two large samples of over 60 sources reveal major differences in the evolution of both the dust and gas components. We report the first detection of organic molecules in disks around brown dwarfs. The detection rate statistics and the line flux ratios of HCN and C{sub 2}H{sub 2} show a striking difference between the two samples, demonstrating a significant underabundance of HCN relative to C{sub 2}H{sub 2} in the disk surface of cool stars. We propose this to originate from the large difference in the UV irradiation around the two types of sources. The statistical comparison of the 10 {mu}m silicate emission features also reveals a difference between the two samples. Cool stars and brown dwarfs show weaker features arising from more processed silicate grains in the disk atmosphere. These findings complement previous indications of flatter disk structures and longer disk lifetimes around cool stars. Our results highlight important differences in the chemical and physical evolution of protoplanetary disks as a function of stellar mass, temperature, and radiation field which should be taken into account in planet formation models. We note that the different chemistry of preplanetary materials in the disk may also influence the bulk composition and volatile content of the forming planets. In particular, if exogenous HCN has played a key role in the synthesis of prebiotic molecules on Earth as proposed, then prebiotic chemistry may unfold differently on planets around cool stars.

99 GENERAL AND MISCELLANEOUS↗

Implications of Bioremediation of Polycyclic Aromatic Hydrocarbon-Contaminated Soils for Human Health and Cancer Risk

Background: Bioremediation uses microorganisms to degrade polycyclic aromatic hydrocarbons (PAHs) in contaminated soils. Its success is largely evaluated through targeted analysis of PAH concentrations in soil and cancer risk (exposure) estimates. However, bioremediation often fails to significantly degrade the most carcinogenic PAHs and can initiate formation of more polar metabolites, some of which may be more toxic. Objectives: We aimed to investigate whether the cancer risk associated with PAH-contaminated soils was reduced post-bioremediation and to identify the most effective bioremediation strategies for degrading the carcinogenic and high molecular weight (≥MW302) PAHs. Methods: Pre- and post-bioremediation concentrations of eight B2 group carcinogenic PAHs in soils were collated from the literature and used to calculate excess lifetime cancer risks (ELCR) for adult populations exposed via non-dietary ingestion, per current U.S. Environmental Protection Agency (USEPA) recommendations. Due to the nature of the collated data (reported as mean concentrations ± standard deviations pre- and post-bioremediation), we used simulation methods to reconstruct the datasets and enable statistical comparison of ELCR values pre- and post-bioremediation. Additionally, we measured MW302 PAHs in a contaminated soil prior to and following treatment in an aerobic bioreactor and examined their contributions to cancer risk. Results: 120 of 158 treated soils (76%) exhibited a statistically significant reduction in cancer risk following bioremediation; however, 67% (106/158) of soils had post-bioremediation ELCR values over 10 fold higher than the USEPA health-based ‘acceptable’ risk level. Composting treatments were most effective at biodegrading PAHs in soils and reducing the ELCR. MW302 PAHs were not significantly degraded during bioremediation and dibenzo(a,l)pyrene, alone, contributed an additional 35% to the cancer risk associated with the eight B2 group PAHs in the same bioremediated soil. Conclusions: Bioremediation strategies often fail to reduce carcinogenic PAH concentrations in contaminated soils below USEPA acceptable cancer risk levels. Additionally, MW302 PAHs and ‘unknown’ metabolites (compounds not routinely measured) are not included in current cancer risk assessments and could significantly contribute to soil carcinogenicity.

bioremediation↗

MO-G-201-01: A Multi-Institutional Study Investigating the Performance of a Knowledge-Based Planning System Against Pinnacle Auto-Planning Engine in SIB-IMRT for the Head-And-Neck Cancer

Purpose: Knowledge-based Planning (KBP) founded on prior planning experience and Auto-Planning Engine (APE; commercialized in Pinnacle v9.10 TPS) based on progressive optimization algorithm both aim to eliminate the trial-and-error process in radiotherapy inverse planning. This study investigates the performance of the approaches in a multi-institutional setting to evaluate their functionalities in oropharyngeal cancer and offers suggestions how they can be implemented in the clinic. Methods: Radboud University Medical Center (RUMC) provided 35 oropharyngeal cancer patients (SIB-IMRT with two-dose-level prescription: 68 Gy to PTV68 and 50.3 Gy to PTV50.3) with corresponding comparative APE plans. Johns Hopkins University (JHU) contributed to a three-dose-level (70 Gy 63 Gy and 58.1 Gy) plan library for RUMC’s patient KBP generation. MedStar Georgetown University Hospital (MGUH) contributed to a KBP approach employing overlap-volume histogram (OVH-KBP) for generating RUMC’s patient KBP plans using JHU’s plan library. Since both approaches need their own user-defined parameters as initial inputs the first 10 patients were set aside as training set to finalize them. Meanwhile cross-institutional comparisons and adjustments were implemented for investigating institutions’ protocol discrepancies and the approaches’ user-defined parameters were updated accordingly. The finalized parameters were then applied to the remaining 25 patients for OVH-KBP and APE generation. A Wilcoxon rank-sum test was used for statistical comparison with significance level of p<0.05. Results: On average PTV68’s V95 was 96.5% in APE plans vs. 97% in OVH-KBP plans (p=0.36); PTV50.3’s V95 in APE plans was 97.8% vs.97.6% in OVH-KBP plans (p=0.6); cord’s D0.1 cc was 38.6 Gy in OVH-KBP plans vs. 43.7 Gy in APE plans (p=0.0001); mean doses to larynxes oral cavities parotids and submandibular glands were similar with p>0.2. Conclusions: The study demonstrates that KBP and APE can generate plans of comparable quality in a multi-institutional setting. Variations in clinical protocols can be effectively addressed for cross-institutional adaptations. Binbin Wu and Todd McNutt are the co-inventors of a patent associated with the proposed knowledge-based planning system which was licensed to Varian Medical Systems in 2015; This research was in part supported by Philips Radiation Oncology Systems.

60 APPLIED LIFE SCIENCES↗

Graph Sampling for Visual Analytics

Effectively visualizing large graphs and capturing the statistical properties are two challenging tasks. To aid in these two tasks, many sampling approaches for graph simplification have been proposed, falling into three categories: node sampling, edge sampling, and traversal-based sampling. It is still unknown which approach is the best. We evaluate commonly used graph sampling methods through a combined visual and statistical comparison of graphs sampled at various rates. We conduct our evaluation on three graph models: random graphs, small-world graphs, and scale-free graphs. Initial results indicate that the effectiveness of a sampling method is dependent on the graph model, the size of the graph, and the desired statistical property. This benchmark study can be used as a guideline in choosing the appropriate method for a particular graph sampling task, and the results presented can be incorporated into graph visualization and analysis tools.

97 MATHEMATICS AND COMPUTING↗

A Unified View of Engineering Creep Parameters

Creep data are often analyzed using derived engineering parameters to correlate creep life (either time to rupture, or time to a specified strain) to applied stress and temperature. Commonly used formulations include Larson-Miller, Orr-Sherby-Dorn, Manson-Haferd, and Manson-Succop parameterizations. In this paper, it is shown that these parameterizations are all special cases of a common general framework based on a linear statistical model. Recognition of this fact allows for statistically efficient estimation of material model parameters and quantitative statistical comparisons among the various parameterizations in terms of their ability to fit a material database, including assessment of a stress-temperature interaction in creep behavior. This provides a rational basis for choosing the best parameterization to describe a particular material. Furthermore, using the technique of maximum likelihood estimation to estimate model parameters allows for a statistically proper treatment of runouts in a test database via censored data analysis methods, and for construction of probabilistically interpretable upper and lower bounds on creep rate. A generalized Larson-Miller formulation is developed, which is comparable in complexity to the Manson-Haferd parameter, but utilizes a reciprocal temperature dependence. The general framework for analysis of creep data is illustrated with analysis of Alloy 617 and Alloy 230 test data.

36 MATERIALS SCIENCE↗

SU-F-T-327: Total Body Irradiation In-Vivo Dose Measurements Using Optically Stimulated Luminescence (OSL) NanoDots and Farmer Type Ion Chamber

Purpose: This study was performed to analyze the agreement between optically stimulated luminescence (OSL) nanoDots measured doses and 0.6 cc Farmer type ionization chamber measured doses during total body irradiation (TBI). Methods: In-vivo dose measurements using OSL nanoDots and Farmer chamber were done in a total of twelve patients who received TBI at our center by bilateral parallel-opposed beams technique. In this technique, the patient is kept inside the TBI box which is filled with rice bags and irradiated using two bilateral parallel opposed beams of 40×40 cm{sup 2} size with 45° collimator rotation at an SSD of 333.5 cm in an Elekta Synergy linear accelerator. All patients received a dose of 2 Gy in single fraction as conditioning regimen. The beams were equally weighted at the midplane of the box. The nanoDots were placed over forehead, right and left neck, right and left lung, umbilicus, right and left abdomen, medial part of thigh, knee and toe. A 0.6 cc Farmer chamber was placed in between the thighs of the patient. Measured doses are reported along with the statistical comparisons using paired sample t-test. Results: For the above sites the mean doses were 212.2±21.1, 218.2±7.6, 218.7±9.3, 215.6±9.5, 217.5±11.5, 214.5±7.7, 218.3±6.8, 221.5±15, 229.1±11.0, 220.5±7.7 and 223.3±5.1 cGy respectively. For all OSL measurements the mean dose was 218.6±11.8 cGy. Farmer chamber measurements yielded a mean dose of 208.8±15.6 cGy. Statistical analysis revealed that there was no significant difference between OSL measured doses in forehead, right and left neck, right and left lung, umbilicus, right and left abdomen and toe and Farmer chamber measured doses (0.72≤p≤0.06). However the mean OSL doses at thigh and knee were statistically different (p<0.05) from the Farmer chamber measurements. Conclusion: OSL measurements were found to be in agreement with Farmer type ionization chamber measurements in in-vivo dosimetry of TBI.

60 APPLIED LIFE SCIENCES↗

Comparison of planetary boundary layer height from ceilometer with ARM radiosonde data

Abstract. Ceilometer measurements of aerosol backscatter profiles have been widely used to provide continuous planetary boundary layer height (PBLHT) estimations. To investigate the robustness of ceilometer-estimated PBLHT under different atmospheric conditions, we compared ceilometer- and radiosonde-estimated PBLHTs using multiple years of U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) ceilometer and balloon-borne sounding data at ARM fixed-location atmospheric observatories and from ARM mobile facilities deployed around the world for various field campaigns. These observatories cover from the tropics to the polar regions and over both ocean and land surfaces. Statistical comparisons of ceilometer-estimated PBLHTs from the Vaisala CL31 ceilometer data with radiosonde-estimated PBLHTs from the ARM PBLHT-SONDE Value-added Product (VAP) are performed under different atmospheric conditions including stable and unstable atmospheric boundary layer, low-level cloud-free conditions, and cloudy conditions at these ARM observatories. Under unstable conditions, good comparisons are found between ceilometer- and radiosonde-estimated PBLHTs at ARM low- and mid-latitude land observatories. However, it is still challenging to obtain reliable PBLHT estimations over ocean surfaces even using radiosonde data. Under stable conditions, ceilometer- and radiosonde-estimated PBLHTs have weak correlations. We compare different PBLHT estimations utilizing the Heffter, the Liu–Liang, and the bulk Richardson number methods applied to radiosonde data with ceilometer-estimated PBLHT. We find that ceilometer-estimated PBLHT compares better with the Liu–Liang method under unstable conditions and compares better with the bulk Richardson number method under stable conditions.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Zero-Net-Rate Pumping Tests

Accurately estimating the distribution of aquifer properties is key to understanding contaminant movement in the subsurface. The distribution of aquifer properties is typically addressed using slug or constant-rate well tests, and the pros and cons of these tests are well known. Slug tests are appealing because they avoid removing contaminated water, but their results are affected by well skin and the small volume of displaced water limits the volume of aquifer that can be evaluated. Constant-rate well tests have the disadvantage of requiring disposal of potentially contaminated water, but they can generate properties that are more representative than slug tests, and they can be used to estimate well efficiency and storativity, which are difficult to characterize using slug tests. Periodic pumping tests are appealing because they have many of the advantages and few of the disadvantages of slug and constant-rate well tests. Periodic pumping tests involve cycling the pumping rate with a regular period and measuring the resulting response in monitoring wells. Some of these tests involve imposing a periodic rate on a constant mean rate. However, other tests involve moving water out and back into the well at rates that are balanced so the net rate after each period is zero. Some zero-net-rate (ZNR) well tests use rates that follow a sinusoidal pattern, whereas others use a square wave pattern that switches between a constant rate of pumping and a constant rate of injection to achieve a zero-net rate. ZNR well tests appear to be a useful compromise between slug and constant rate tests, but methods for conducting and analyzing the results from these tests have received limited evaluation. Periodic pumping tests are typically evaluated through recorded pressure responses to a disturbance source. Recent work has demonstrated that the strain field in the vadose zone shows a response to disturbances in the underlying aquifer. Various instrument designs are available that can record vertical and horizontal strain to very precise resolutions (10-9 ε). Measuring the strain in the vadose zone can present lower costs than measuring pressure in a monitoring well, so using strain could improve the resolution of ZNR tests, as well as make these tests potentially cheaper. A ZNR periodic pumping system was constructed and used to perform tests in the Clemson, South Carolina area. The system was designed to pump and inject with a periodic square-wave, so pumping occurs at a constant rate for half the period and is followed by injection at the same rate for half the period resulting in no net gain or loss of water from the aquifer. The system is designed to generate flow rates from 1 to 3.5 gallons per minute (gpm) with a capacity of 875-gallon per half period. Pressure and strain monitoring points are located in the vicinity of the pumping well. A series of 10 ZNR periodic pumping tests were conducted at the field site, with periods ranging from 2 to 540 minutes. Pressure data were collected and recorded in four monitoring wells in various locations around the pumping well. In addition, vertical and horizontal strain and tilt data were recorded in various locations around the pumping well. Traditional aquifer tests, including slug tests and constant-rate pumping tests were conducted at the field site to provide a baseline of aquifer parameter estimates that are compared the results of ZNR tests. Pressure data measured at monitoring wells during ZNR tests were analyzed utilizing an analytical solution (Streltsova, 1988) that assumes a confined aquifer and estimates hydraulic diffusivity and transmissivity using the time lag and amplitude of the pressure signal. The storativity can be separated out from the hydraulic diffusivity using the transmissivity estimate. The time-lag and amplitude of the pressure signals were estimated using a Fourier transform. The time-lag of the primary period of the pressure increases as a linear function of distance from the pumping well, and it increases as the square root of the period of the ZNR test over a range of periods spanning two orders of magnitudes. The first few harmonics follow similar trends, but the higher frequency harmonics diverge from this trend. Strain and tilt data from various instruments in the vadose and saturated zones are periodic during ZNR tests. The time lags of the strain components increase roughly linearly with distance from the well. Many of the time lags of the strain data from the vadose zone are similar to the time lags observed in the pressure data from a similar distance and pumping period. Theoretical experiments were performed to understand how pressure and strain responds to ZNR periodic pumping. The time-lags of the simulated pressure responses match the field data trends. The results were used to validate the Streltsova (1988) solution for periodic pumping to estimate hydraulic diffusivity. Hydraulic diffusivity was estimated to be 1.8 x 10-2 m2s-1 < Dh < 9.0 x 10-2 m2s-1 using pressure data from all the wells during ZNR tests. Transmissivity was estimated to be 0.8 x 10-4 m2s-1 < T < 4.3 x 10-4 m2s-1. Assuming Storativity = T/Dh gives 1.1 x 10-3 < S < 19 x10-3. Transmissivity is used to estimate the hydraulic conductivity, K, by dividing by the assumed aquifer thickness. Two constant-rate pumping tests were conducted and analyzed using two conceptual models: The Hantush (1961) solution was used to analyze data assuming confined conditions and the Neuman (1974) solution was used to analyze data assuming unconfined conditions. The Hantush (1961) solution estimated transmissivity to be 1.6 x 10-4 m2s-1 < T < 1.8 x 10-4 m2s-1 when using data from all the wells. Storativity was estimated to be 4.4 x 10-3 < S < 8.2 x 10-3. Assuming Dh = T/S gives 0.22 x 10-2 m2s-1 < Dh < 3.6 x 10-2 m2s-1. The Neuman (1974) solution estimated transmissivity to be 0.80 x 10-4 m2s-1 < T < 0.84 x 10-4 m2s-1. Total storativity (S + Sy) was estimated to be 22 x 10-3 < S < 110 x 10-3. Storativity excluding the Sy term was estimated to be 2.2 x 10-3 < S < 2.5 x 10-3. Assuming Dh = T/S gives 0.073 x 10-2 m2s-1 < S < 0.36 x 10-2 m2s-1. Two slug tests were performed on the pumping well, PW-2. The Bouwer and Rice (1976) solution for slug tests was used to analyze the data. This solution works for both confined and unconfined conditions, so both conceptual models were covered through the analysis. Hydraulic conductivity was estimated to be 1.95 x 10-6 ms-1 < K < 2.49 x 10-6 ms-1. Statistical comparison show generally no significant difference in the estimates of Dh, K, or S made using ZNR and conventional pumping tests.. However, the total storage estimated by the Neuman (1974) solution for unconfined settings is larger than that estimate using the Streltsove analysis applied to the ZNR tests. This is likely because the Neuman solution considers delayed yield from storage that the water table, whereas the Streltsova (1988) solution assumes confined conditions. The analysis also indicates that there is a statistically significant difference between parameters estimated with conventional slug tests and those measured with either constant-rate pumping tests or ZNR tests. Hydraulic diffusivity is estimated from the time-lag and the distance from the well. The time-lags of the strain data from the vadose zone are similar to the lags of the pressure data from a similar distance. This indicates that hydraulic diffusivities estimated from the strain data measured in the vadose zone would be similar to the estimates from the pressure data measured in the aquifer. There appear to be sign reversals in some of the strain data that were corrected to estimate the time lag. The dissolved oxygen (CO) concentration was measured during several ZNR tests to evaluate the feasibility of using the procedure to increase contaminant degradation kinetics that are related to DO. The results indicate that DO can be increased during the cycling of ZNR tests in some cases.

Smith-Jones, Austin↗

IMPLICATIONS OF THE TENTATIVE ASSOCIATION BETWEEN GW150914 AND A FERMI -GBM TRANSIENT

The merger-driven gamma-ray bursts (GRBs) and their associated gravitational-wave (GW) radiation, if both are successfully detected, have some far-reaching implications, including, for instance: (i) the statistical comparison of the physical properties of the short/long-short GRBs with and without GW detection can test the general origin model; (ii) revealing the physical processes taking place at the central engine; (iii) measuring the velocity of the gravitational wave directly/accurately. In this work, we discuss these implications in the case of a possible association of GW150914/Gamma-ray Burst Monitor (GBM) transient 150914. We compared GBM transient 150914 with other SGRBs and found that such an event may be a distinct outlier in some statistical diagrams, possibly due to its specific binary black hole merger origin. However, the presence of a “new” group of SGRBs with “unusual” physical parameters is also possible. If the outflow of GBM transient 150914 was launched by the accretion onto the nascent black hole, the magnetic activity rather than the neutrino process is likely responsible for the energy extraction, and the accretion disk mass is estimated to be ∼10{sup −5} M {sub ⊙}. The GW150914/GBM transient 150914 association, if confirmed, would provide the first opportunity to directly measure the GW velocity, and its departure from the speed of the light should be within a factor of ∼10{sup −17}.

79 ASTRONOMY AND ASTROPHYSICS↗

EMISSION SIGNATURES FROM SUB-PARSEC BINARY SUPERMASSIVE BLACK HOLES. I. DIAGNOSTIC POWER OF BROAD EMISSION LINES

Motivated by advances in observational searches for sub-parsec supermassive black hole binaries (SBHBs) made in the past few years, we develop a semi-analytic model to describe spectral emission-line signatures of these systems. The goal of this study is to aid the interpretation of spectroscopic searches for binaries and to help test one of the leading models of binary accretion flows in the literature: SBHB in a circumbinary disk. In this work, we present the methodology and a comparison of the preliminary model with the data. We model SBHB accretion flows as a set of three accretion disks: two mini-disks that are gravitationally bound to the individual black holes and a circumbinary disk. Given a physically motivated parameter space occupied by sub-parsec SBHBs, we calculate a synthetic database of nearly 15 million broad optical emission-line profiles and explore the dependence of the profile shapes on characteristic properties of SBHBs. We find that the modeled profiles show distinct statistical properties as a function of the semimajor axis, mass ratio, eccentricity of the binary, and the degree of alignment of the triple disk system. This suggests that the broad emission-line profiles from SBHB systems can in principle be used to infer the distribution of these parameters and as such merit further investigation. Calculated profiles are more morphologically heterogeneous than the broad emission lines in observed SBHB candidates and we discuss improved treatment of radiative transfer effects, which will allow a direct statistical comparison of the two groups.

79 ASTRONOMY AND ASTROPHYSICS↗

Lidar Inter-Comparison Exercise Final Campaign Report

The objective of this IOP was to evaluate the performances of the new Leosphere R-MAN 510 lidar procured by the Australian Bureau of Meteorology, by testing it against the MPL and Raman lidars at the Darwin ARM site. This lidar is an eye-safe (355 nm), turn-key mini Raman lidar, which allows for the detection of aerosols and cloud properties, and the retrieval of particulate extinction profiles. To do so, the R-MAN 510 lidar has been operated at the Darwin ARM site, next to the MPL, Raman lidar, and Vaisala ceilometer for three months (from 20 January 2013 to 20 April 2013) in order to collect a good sample for statistical comparisons. The comparisons with the Raman lidar were not performed, since the Raman lidar attenuated backscatter and depolarization ratio product was not available. A new product has just been delivered to the ARM archive as a value-added product, hence this study will continue. Nevertheless we have developed software to match the different space and time resolutions of the other lidars and project the data onto a common grid to permit detailed comparison of the instruments’ performance and an enhanced analysis of clouds and aerosols through the use of composite data products, like the ratios of attenuated backscatters, attenuated scattering ratios and depolarization ratios. Comparisons between the MPL and R-MAN510 lidar data exhibit large differences in total attenuated backscatter at 355 and 532 nm, attenuated scattering ratios, and aerosol volume depolarization ratios. Differences in attenuated backscatter result mainly from the different relative contributions of scattering from molecules and particles at the different wavelengths, but there are some intriguing differences that will require further investigations. The differences in volume depolarization ratios are due to the much larger contribution of molecular returns to the volume depolarization ratio (5 times larger at 355 nm than at 532 nm). The R-MAN510 lidar is also found to be much less sensitive to daylight solar background illumination, which is greater at the visible wavelength than in the UV.

54 ENVIRONMENTAL SCIENCES↗

Structure of the accretion disk in the lensed quasar Q2237+0305 from multi-epoch and multi-wavelength narrowband photometry

We present estimates for the size and the logarithmic slope of the disk temperature profile of the lensed quasar Q2237+0305, independent of the component velocities. These estimates are based on six epochs of multi-wavelength narrowband images from the Nordic Optical Telescope. For each pair of lensed images and each photometric band, we determine the microlensing amplitude and chromaticity using pre-existing mid-IR photometry to define the baseline for no microlensing magnification. A statistical comparison of the combined microlensing data (6 epochs × 5 narrow bands × 6 image pairs) with simulations based on microlensing magnification maps gives Bayesian estimates for the half-light radius of R{sub 1/2}=8.5{sub −4.0}{sup +7.5}√(〈M〉/0.3 M{sub ⊙}) lt-day, and p = 0.95 ± 0.33 for the exponent of the logarithmic temperature profile T∝R{sup −1/p}. This size estimate is in good agreement with most recent studies. Other works based on the study of single microlensing events predict smaller sizes, but could be statistically biased by focusing on high-magnification events.

79 ASTRONOMY AND ASTROPHYSICS↗

Lidar Inter-Comparison Exercise Final Campaign Report

The objective of this field campaign was to evaluate the performance of the new Leosphere R-MAN 510 lidar, procured by the Australian Bureau of Meteorology, by testing it against the MicroPulse Lidar (MPL) and Raman lidars, at the Darwin Atmospheric Radiation Measurement (ARM) site. This lidar is an eye-safe (355 nm), turn-key mini Raman lidar, which allows for the detection of aerosols and cloud properties, and the retrieval of particulate extinction profiles. To accomplish this evaluation, the R-MAN 510 lidar has been operated at the Darwin ARM site, next to the MPL, Raman lidar, and Vaisala ceilometer (VCEIL) for three months (from 20 January 2013 to 20 April 2013) in order to collect a sufficient sample size for statistical comparisons.

Protat, A↗

Data & Code from Phoenix CPPP Phase 2 Analysis

This data and code package supports the analysis presented in “Beyond Surface Cooling: Comprehensive Field Assessment of Reflective Pavement Thermal Performance in Phoenix, Arizona” and provides fully reproducible workflows for evaluating the thermal performance of cool pavement treatments in a hot urban environment. The dataset integrates multi-modal field measurements collected across residential and nonresidential settings, including mobile air temperature traverses, stationary air temperature monitoring, residential mean radiant temperature (MRT) measurements, subsurface temperature profiles, and controlled testbed observations. The data package contains raw and processed datasets in comma-separated value (CSV) format, accompanying metadata files describing site characteristics and measurement protocols, and R scripts (.R files) used for data cleaning, time synchronization, spatial and temporal matching, quality control filtering, statistical comparison, and figure generation. All analyses were conducted using R (version ≥ 4.2.0) with commonly available packages (e.g., tidyverse, lubridate, data.table, ggplot2). No proprietary software is required to reproduce results. Field campaigns were designed to quantify the effects of high-reflectance pavement coatings on surface temperature, near-surface air temperature, subsurface heat propagation, and radiative heat exposure. Temporal alignment procedures include standardized timestamp conversion and nearest-neighbor matching of high-frequency sensor measurements to stop-based metadata within defined tolerance windows to ensure comparability across instruments. The workflows generate summary statistics, treatment–control contrasts, depth-dependent thermal gradients, and time-series visualizations used in the associated publication. By integrating mobile, stationary, radiative, and subsurface measurements within a unified and transparent processing framework, this package enables comprehensive evaluation of cool pavement performance across multiple thermal exposure pathways and supports reuse in future urban heat mitigation and climate resilience studies.

AIR TEMPERATURE↗

Dosimetric Comparison of Combined Intensity-Modulated Radiotherapy (IMRT) and Proton Therapy Versus IMRT Alone for Pelvic and Para-Aortic Radiotherapy in Gynecologic Malignancies

Purpose: To perform a dosimetric comparison of intensity-modulated radiotherapy (IMRT), passive scattering proton therapy (PSPT), and intensity-modulated proton therapy (IMPT) to the para-aortic (PA) nodal region in women with locally advanced gynecologic malignancies. Methods and Materials: The CT treatment planning scans of 10 consecutive patients treated with IMRT to the pelvis and PA nodes were identified. The clinical target volume was defined by the primary tumor for patients with cervical cancer and by the vagina and paravaginal tissues for patients with endometrial cancer, in addition to the regional lymph nodes. The IMRT, PSPT, and IMPT plans were generated using the Eclipse Treatment Planning System and were analyzed for various dosimetric endpoints. Two groups of treatment plans including proton radiotherapy were created: IMRT to pelvic nodes with PSPT to PA nodes (PSPT/IMRT), and IMRT to pelvic nodes with IMPT to PA nodes (IMPT/IMRT). The IMRT and proton RT plans were optimized to deliver 50.4 Gy or Gy (relative biologic effectiveness [RBE)), respectively. Dose-volume histograms were analyzed for all of the organs at risk. The paired t test was used for all statistical comparison. Results: The small-bowel V{sub 20}, V{sub 30}, V{sub 35}, andV{sub 40} were reduced in PSPT/IMRT by 11%, 18%, 27%, and 43%, respectively (p < 0.01). Treatment with IMPT/IMRT demonstrated a 32% decrease in the small-bowel V{sub 20}. Treatment with PSPT/IMRT showed statistically significant reductions in the body V{sub 5-20}; IMPT/IMRT showed reductions in the body V{sub 5-15}. The dose received by half of both kidneys was reduced by PSPT/IMRT and by IMPT/IMRT. All plans maintained excellent coverage of the planning target volume. Conclusions: Compared with IMRT alone, PSPT/IMRT and IMPT/IMRT had a statistically significant decrease in dose to the small and large bowel and kidneys, while maintaining excellent planning target volume coverage. Further studies should be done to correlate the clinical significance of these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Statistical Approaches for Pebble Bed Reactor Operations and Safeguards

The design of pebble bed reactors (PBRs) and their method of operation align more closely with statistical approaches used in manufacturing and process control than traditional safeguards statistical approaches. The reason is PBRs will employ a nondestructive assay (NDA) measurement (burnup measurement system [BUMS]) that is part of the fuel handling system supporting discharge decisions in addition to the reactor code which monitor performance. The integration of these two approaches provides the opportunity to monitor reactor performance statistically for both operations and safeguards in ways not achievable using other reactor designs. For light water reactors (LWRs), knowledge about reactor code performance in predicting irradiated special nuclear material (SNM) content historically was only achieved from special measurement campaigns or from fuel reprocessing. Conversely, through statistical comparison of the BUMS with the reactor code-predicted values, PBRs can achieve this in real time. The resulting SNM distribution is an indicator of reactor performance because factors such as transit time and path of the pebble fuel through the reactor determine the plutonium production and uranium depletion. By analyzing the predicted and measured values, opportunities exist to adjust operating parameters, fuel design, and other characteristics to optimize performance and fuel utilization. From a safeguards perspective, this approach also provides the information necessary to validate declared values and evaluate whether the reactor is being operated as expected. This paper outlines statistical approaches for PBRs that can be used to support both operations and safeguards.

Ball, Cory↗

Rapid Analysis of Carbohydrates in Bioprocess Samples: An Evaluation of the CarboPac SA10 for HPAE-PAD Analysis by Interlaboratory Comparison

A technique for carbohydrate analysis for bioprocess samples has been developed, providing reduced analysis time compared to current practice in the biofuels R&D community. The Thermofisher CarboPac SA10 anion-exchange column enables isocratic separation of monosaccharides, sucrose and cellobiose in approximately 7 minutes. Additionally, use of a low-volume (0.2 mL) injection valve in combination with a high-volume detection cell minimizes the extent of sample dilution required to bring sugar concentrations into the linear range of the pulsed amperometric detector (PAD). Three laboratories, representing academia, industry, and government, participated in an interlaboratory study which analyzed twenty-one opportunistic samples representing biomass pretreatment, enzymatic saccharification, and fermentation samples. The technique's robustness, linearity, and interlaboratory reproducibility were evaluated and showed excellent-to-acceptable characteristics. Additionally, quantitation by the CarboPac SA10/PAD was compared with the current practice method utilizing a HPX-87P/RID. While these two methods showed good agreement a statistical comparison found significant quantitation difference between them, highlighting the difference between selective and universal detection modes.

09 BIOMASS FUELS↗