Search NASA⌕ Search

SEARCH · Search NASA

Results for “storage consistency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Utilizing Commercial Submersible Mixer Pumps for Sludge Removal in Savannah River Site's Tank 26 - 20289

The Savannah River Site (SRS) Liquid Waste System (LWS) safely manages, stores, treats, and dispositions liquid radioactive waste. The LWS consists of 51 underground waste storage tanks (eight of which are operationally closed and filled with grout), waste evaporators, treatment facilities, and solidification facilities, known as the Defense Waste Processing Facility (DWPF) and Saltstone Production Facility (SPF). One of the waste storage tanks, Tank 26, was placed into service in 1980 as an F Tank Farm (FTF) Evaporator Feed Tank. From 1980 to 2013, Tank 26 received F Canyon receipts and dilute supernate that was then transferred to the 242-16F FTF Evaporator for volume reduction. In 2013, the steam tube bundle failed in the FTF Evaporator, and the decision was made not to repair/resume evaporator operation. During operation of Tank 26, solids built up to a level of 2.03 m in the tank with a volume of 1062.9 kL. Due to the evaporator failure and subsequent shutdown, the solids in Tank 26 were selected to feed Sludge Batch 10, which is collected and prepped prior to being sent to DWPF for final disposition. To accomplish solids removal, Commercial Submersible Mixer Pumps (CSMPs) were selected to slurry the solids in preparation to be sent to Tank 51. Four CSMPs were installed in Tank 26 with each one installed in a separate quadrant of Tank 26. This work would mark the first deployment of CSMPs in an SRS waste tank. The CSMPs were developed in response to operational issues from previous mixing pumps and budgetary constraints. The CSMPs use the concept of modifying commercially available equipment for nuclear waste applications. The CSMPs consist of a 230-horsepower submersible mixing pump (manufactured by GPM, Inc.) joined to a mast fabricated at SRS. For this application, Savannah River Remediation (SRR) design services was challenged to provide a mast design that required no steel superstructure support system on top of Tank 26. Also, SRR design services provided a simplified Tank 26 riser interface that did not require extensive machine parts to adjust height of the suction screen of the CSMP within the tank. Other design improvements include no requirements for tank top radiation monitors and no requirements for flushing of the CSMPs during startup/shutdown operations. The CSMPs were operated at an initial height of 2.29 m above the Tank 26 bottom for 10 days. After sludge sounding, the CSMPs were lowered to a height of 1.52 m with no issues due to proper work planning and the simplified riser interface. With the CSMPs lowered to a level of 1.52 meters above the tank bottom, the CSMPs were operated for 12 days and another sounding was performed. The sounding level came back matching the disturbance depth results of the first pump run. Chemistry samples were analyzed while the tank was left to settle. The analysis revealed enough weight percent solids to provide good feed to Sludge Batch 10. Also, the results revealed the supernate within the mixture would provide good salt solution feed to Salt Waste Processing Facility (SWPF) Salt Batch 3. So, the plan was modified to let the disturbed solids settle and decant the salt solution for addition to SWPF Salt Batch 3. Then water will be added back to Tank 26, and the CSMPs run in order to wash the solids to decrease settling time prior to being sent to Tank 51 for Sludge Batch 10. Utilizing CSMPs for waste removal in an SRS Tank has provided a cost-effective means for further waste removal efforts. In addition, the CSMPs are easier to operate by utilizing a robust and simplified design. The CSMPs performed quite well with no process shutdown or delays during operation. As a result, CSMPs are integral to the future of removing radioactive waste from storage tanks at SRS. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Workflow for Developing and Operating Subsurface Hydrogen Storage Facilities in Porous Reservoirs

Long-duration (seasonal) storage of natural gas (NG), which primarily consists of methane (CH 4 ), has been practiced for more than a hundred years at underground gas storage (UGS) facilities that use depleted hydrocarbon reservoirs, saline aquifers, and salt caverns. To enable hydrogen (H 2 ) to be used as a long-duration, energy-storage medium, similar facilities are envisioned for underground H 2 storage (UHS) of either H 2 or H 2 /NG mixtures. Experience with UGS can be used to guide recommended practices for developing and operating UHS facilities in porous reservoirs. The most important factors (formation/fluid properties and engineering choices) that influence the performance of UHS reservoirs have been identified and quantified in previous studies. These factors and choices influence phenomena that determine the sweep efficiency of the stored working gas. These phenomena include viscous fingering, hysteretic capillary trapping, and gravity override of the working gas, as well as the upconing of nonproductive fluid that determine the sweep efficiency of the stored working gas. This report describes initial recommended-practices and a project-development workflow for UHS facilities that utilize porous reservoirs, based on the current state-of-knowledge about H 2 behavior in the subsurface. The workflow sequentially addresses all aspects of UHS project development, including the identification of H 2 sources and users, site ranking and down-selection, geologic and reservoir-engineering characterization, reservoir design, testing, risk management, commissioning, operations, and monitoring for a UHS facility. The goal is to enable UHS facilities to be developed in an efficient and timely manner, while carefully managing project risks. This workflow is similar to that which has been developed for UGS facilities (see Figure 1 of API, 2022), with the addition of tasks and subtasks specific to H 2 and UHS. The project-development workflow is broken down into three major stages: (1) define the H 2 use case; (2) rank, down-select, and characterize potential, candidate UHS sites; and (3) reservoir design, integrity testing, risk assessment, commissioning, operations, and monitoring for selected UHS sites. Each major stage is further broken down into tasks and subtasks, which are described at a high level. This report also provides more detailed descriptions of all tasks and subtasks that involve reservoir analysis and testing.

08 HYDROGEN↗

Resonant anomalous X-ray reflectivity for revealing ion distributions near electrodes

Energy storage devices–batteries, for example–consist of an electrolyte sandwiched between two charged electrodes through which current can pass. The metal ion organization at the electrode–electrolyte interface, commonly referred to as the electric double layer, determines the efficiency and stability of the device. There are two major challenges with experimentally characterizing the metal ion distribution at the interface.

42 ENGINEERING↗

Metabolic flux, metabolite, and transcript analysis uncover reprogramming of metabolism toward higher seed oil

Overexpression of WRINKLED1 (WRI1), a master regulator of glycolysis and fatty acid biosynthesis, together with DIACYLGLYCEROL ACYLTRANSFERASE1 (DGAT1), which catalyzes the final step of triacylglycerol assembly, is a promising strategy for enhancing seed oil content. However, how these regulators coordinate system-wide metabolic reprogramming at the levels of gene expression, metabolite pools, and fluxes remains poorly understood. To address this, we performed 13 C-metabolic flux analysis, metabolomics, and transcriptomics on in vitro cultured pennycress (Thlaspi arvense L.) embryos overexpressing the native WRI1 and DGAT1 homologs. Here, in cultured embryos, WRI1/DGAT1 overexpression increased triacylglycerol accumulation by 28% while reducing protein content by 34%, relative to the wild type. Embryos showed ∼20-fold and 50-fold upregulation of WRI1 and DGAT1 along with induction of WRI1 target genes in glycolysis and fatty acid biosynthesis. Genes associated with photosynthesis and Calvin cycle functions were also upregulated, whereas genes encoding ribosomal proteins and seed storage proteins were strongly repressed, consistent with the observed lipid–protein tradeoff. Flux analysis revealed that enhanced triacylglycerol biosynthesis is supported by increased flux through the Rubisco shunt and cytosolic pyruvate kinase, while the oxidative pentose phosphate pathway and malic enzyme contributed little to NADPH or pyruvate supply. Metabolomic profiling revealed extensive perturbations in glycolytic intermediates, tricarboxylic acid cycle metabolites, and amino acids. In plant grown seeds, WRI1/DGAT1 lines also showed a modest but significant increase in total lipid content. Collectively, these findings reveal how WRI1 and DGAT1 reprogram central metabolism to enhance oil accumulation, with relevance to mature seeds.

59 BASIC BIOLOGICAL SCIENCES↗

Integration of the Back End of the Nuclear Fuel Cycle

Management of spent nuclear fuel and high-level radioactive waste consists of three main phases – storage, transportation, and disposal – commonly referred to as the back end of the nuclear fuel cycle. Current practice for commercial spent nuclear fuel management in the United States (US) includes temporary storage of spent fuel in both pools and dry storage systems at operating or shutdown nuclear power plants. Storage pools are filling to their operational capacity, and management of the approximately 2,200 metric tons of spent fuel newly discharged each year requires transferring older and cooler spent fuel from pools into dry storage. Unless a repository becomes available that can accept spent fuel for permanent disposal, projections indicate that the US will have approximately 136,000 metric tons of spent fuel in dry storage systems by mid-century, when the last plants in the current reactor fleet are decommissioned. Current designs for dry storage systems rely on large multi-assembly canisters, the most common of which are so-called “dual-purpose canisters” (DPCs). DPCs are certified for both storage and transportation, but are not designed or licensed for permanent disposal. The large capacity (greater number of spent fuel assemblies) of these canisters can lead to higher canister temperatures, which can delay transportation and/or complicate disposal. This current management practice, in which the utilities continue loading an ever-increasing inventory of larger DPCs, does not emphasize integration among storage, transportation, and disposal. This lack of integration does not cause safety issues, but it does lead to a suboptimal system that increases costs, complicates storage and transportation operations, and limits options for permanent disposal. This paper describes strategies for improving integration of management practices in the US across the entire back end of the nuclear fuel cycle. The complex interactions between storage, transportation, and disposal make a single optimal solution unlikely. However, efforts to integrate various phases of nuclear waste management can have the greatest impact if they begin promptly and continue to evolve throughout the remaining life of the current fuel cycle. A key factor that influences the path forward for integration of nuclear waste management practices is the identification of the timing and location for a repository. The most cost-effective path forward would be to open a repository by mid-century with the capability to directly dispose of DPCs without repackaging the spent fuel into disposalready canisters. Options that involve repackaging of spent fuel from DPCs into disposalready canisters or that delay the repository opening significantly beyond mid-century could add 10s of billions of dollars to the total system life cycle cost.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Real-Time Optimization Workflow Status Update

Economically optimal and safe operation of integrated energy systems (IES) requires optimization at many different time scales. A real-time optimization (RTO) workflow will attempt to maximize revenue and minimize operational costs on a time scale of minutes to hours. Such a workflow requires the use of a digital twin (DT), which is a virtual representation of a physical system. The DT is updated using real-time data from the physical system, and serves as a model in an optimization framework. The optimization results are then sent back to the physical system to complete the loop. This report details the progress made in developing building blocks for a DT/RTO framework. The Risk Analysis Virtual Environment (RAVEN) platform within the Framework for Optimization of Resources and Economics (FORCE) tool suite can perform many of the tasks required for building a DT and performing RTO. The first item of this report details RAVEN enhancements that enable RAVEN workflows to be run in various environments. Data communication between the physical system and its DT is essential for successful RTO. This includes preprocessing real-time data, loading data into a data warehouse, and querying the stored data. The second section of this report describes the progress made in implementing an adapter in Python in order for Deep Lynx to handle the data communication. Typical dispatch optimization frameworks are built on linear programming (LP). The prototype RTO workflow developed in this report uses an LP problem as a part of a receding-horizon- or economic model predictive control (EMPC) based optimization. The third section of this report details the framework of an RTO workflow in which the system consists of a simple electrical storage device. A DT can be built from a reduced-order model (ROM). Integrating a ROM into a typical LP optimization framework has been challenging because most optimization packages require the user to write algebraic expressions for the system model. The final section of this report shows how an externally built RAVEN ROM can be integrated in an RTO framework by using the Python package Pyomo. This demonstrates the RTO workflow capability from a software-only perspective and is an important step in demonstrating the capability to implement an RTO workflow for a physical system.

97 MATHEMATICS AND COMPUTING↗

Scalable, In-situ Data Clustering Data Analysis for Extreme Scale Scientific Computing (Final Report)

The objective of this project is to address challenges in the design and development of scalable in-situ data clustering and analytics algorithms and software. Our goal is to develop parallel software consisting of a set of spatio-temporal data clustering and anomaly detection functions, both of which are very important for large-scale analysis and have wide applicability for in-situ runs as well as post-processing analysis. Our design principles for in-situ analysis consider the following: (1) identify parts of the computation can be done close to the data within the nodes, while it is still in memory; (2) extract analysis components can (and should) be performed in remote staging and analysis nodes; (3) develop error-bound approximation methods for applications tolerable for small errors; (4) identify the type of derived distributions and statistics, for spatio-temporal data, that can be kept locally in order to both accelerate computations and meet energy constraints in subsequent iterations and phases; (5) use a self-describing data format so that data can be consistent and understood among local storage (memory and SSDs) and at staging and analysis nodes, thereby providing portability and flexibility; (6) develop service-oriented functions that can schedule in-situ and post-hoc analysis tasks based on the dynamic requirements of applications. Our development focus is to produce the parallel data analysis software/library that will be scalable, reusable, extensible, and generic for applications in different disciplines. The software will be able to run in-situ with the simulations as well as post-hoc analysis. This approach will satisfy many synergistic requirements for data intensive applications executed on data coming from instruments and experiments. In particular, the proposed multilevel approach is directly applicable to perform design tradeoffs for running part of the algorithms near the instruments and the rest on remote (analysis) systems.

97 MATHEMATICS AND COMPUTING↗

Economic Evaluation of a Coupled Nuclear Power Plant and Hydrogen Production Facility: A Case Study

This study optimized the design sizes and operation of a power-to-hydrogen-to-power integrated energy system to allow a baseload power plant to operate flexibly in the energy market. In collaboration with a utility industry partner, the system, consisting of an electrolyzer, compressors, storage tank, and fuel cell, was optimized under conditions specific to the proposed project at the site of a nuclear power plant. The Design Integration and Synthesis Platform to Advance Tightly Coupled Hybrid Energy Systems (DISPATCHES) maximized net present value by optimizing sizing of components and dispatch decisions. Revenues included sale of electricity, capacity payments typical of the New York Independent System Operator, and the section 45V hydrogen production tax credit of the Inflation Reduction Act of 2022 (the tax credit was assumed to be available to legacy plants in the absence of clear guidance at present). Under default assumptions which excluded many capital expenditures, the base case optimized solution had a net present value of $\$$1.4 million over a 30 year lifetime, with a 0.365 MW fuel cell operating nearly continuously and 85% of revenues supplied by the hydrogen production tax credit (which was counted as a revenue regardless of profit, thus assuming credit monetization or offset of taxes within the larger firm was possible in all years). Beyond the base case, a sensitivity study elucidated drivers of the economics as capacity payment rate and hydrogen production tax credit rate vary. Additional sensitivity studies also extended results to variation of other, previously fixed parameters, including the fuel cell capital cost, and to imposition of further constraints. Optimization was also repeated for the default assumptions but recognizing tax credits upon use of hydrogen rather than upon its production, producing no change in the optimal solution. Most notably, capacity payments above $\$$15/kW-month drove optimal fuel cells multiple times larger than those with the default estimated capacity payment of $\$$2.5/kW-month (approaching 11 vs. 0.365 MW), and these larger fuel cells operated rarely (capacity factors of ~0.03). Furthermore, when the hydrogen production tax credit was provided for only 10 years, under the specific assumptions of this study (e.g., neither site preparation costs nor electrolyzer capital cost counted), the optimal solution avoided economic loss by ceasing system operation after the 10th year. Viewed broadly, this study demonstrated the capabilities of DISPATCHES, which can be user-adapted to serve other industrial case studies.

08 HYDROGEN↗

Residential Solar-Adopter Income and Demographic Trends: November 2022 Update [Slides]

The report describes income, demographic, and other socio-economic trends among U.S. residential rooftop solar adopters. The report is based on address-level data for roughly 2.8 million residential rooftop solar systems installed through 2021, representing 86% of all U.S. systems. With its unique size, geographic scope, and level of detail, this report is intended to serve as a foundational reference document for policy-makers, industry stakeholders, and researchers. Key findings include the following: -Median solar adopter income was about $\$110$k/year in 2021, compared to a U.S. median of about $\$63$k/year for all households and $\$79$k/year for all owner-occupied households -The degree of income skew varies significantly across all states, but all states exhibit some positive income skew, with median solar-adopter incomes ranging from 131-168% of the respective county-median income for all households -Notwithstanding the fact that solar adopter incomes skew high, a substantial share of adopters could be considered low-to-moderate income (LMI), with 22% of all 2021 adopters earning less than 80% of area median income, and an additional 21% between 80% and 120% of area median income. -Solar-adopter incomes are declining over time, with median incomes dropping from $\$129$k in 2010 to $\$110$k in 2021, as adoption becomes more proportionately distributed across the population and has started to broaden into low- and middle-income states since 2016. -Solar-adopter incomes are consistently higher for systems paired with battery storage, for host-owned systems, and for systems installed on single-family homes; higher income adopters also consistently install larger systems. -Solar adopters tend to live in Census Tracts not identified as “disadvantaged communities” (using the U.S. Department of Energy’s interim definitions developed March 2022), making up 11% of adopters compared to 18% of U.S. households. -Compared to the broader population, solar adopters tend to: identify as Non-Hispanic White, be primarily English-speaking, have higher education levels, be middle-aged, work in business and finance-related occupations, and live in higher-value homes In conjunction with the report, Berkeley Lab has published an updated accompanying set of online data visualizations that allow users to further explore the underlying data. Berkeley Lab is also offering related analytical support to states, local agencies, and other organizations on issues related to solar adoption among low-to-moderate income households; requests for analytical support may be submitted through this online form.

13 HYDRO ENERGY↗

Optical Fiber H2 Sensor Operating in Harsh Environments of Subsurface H2 Storage Reservoirs

Monitoring hydrogen concentration in the subsurface storage reservoirs is vital to ensure the integrity and safety of the storage facilities. An optical fiber hydrogen sensor consisting of a palladium-based sensing layer and a protective polymer layer was developed and evaluated in simulated subsurface hydrogen storage conditions. The developed optical fiber hydrogen sensor has demonstrated successful sensing performance at ~80 °C, ~1,000 psi, and ~100% RH. In addition, the sensor was exposed to real subsurface microbial samples in the harsh environments to monitor microbially induced changes in hydrogen concentration. The sensor has shown stable H2 sensing responses in the replicated underground hydrogen storage conditions without deterioration or loss of H2 sensitivity in the presence of biological samples.

filter layer↗

FY2025 Status Report: Model 9975 O Ring Fixture Long-Term Leak Performance

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package have been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The mock-up PCV fixtures are leak tested periodically, and all GLT O-ring fixtures aged at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aged at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years of aging without failure. Two of these retired fixtures were returned to testing and heated to 350 °F to evaluate the impact of additional heating at higher temperature for aged O-rings. Fixture #20 failed after 3 months while fixture #18 failed after 9 months at 350 °F. These O-rings demonstrated that aged and in-service O-rings can continue to be used, even at higher temperatures, after being in storage, and their leak performance are consistent with other samples at 350 °F. There has been one GLT O-ring fixture which failed after 13.4 years of aging at 200 °F. However, 20 other GLT O-rings aging at 200 °F have remained leak-tight for over 16.9 years and remain in test. There are two GLT O-ring fixtures at 270 °F; one fixture has failed after 12.9 years while the other fixture remains in test after 12.5 years. All GLT-S O-ring fixtures aged at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 250 °F for 14.9 years, while one GLT-S O-ring fixture failed after 12.4 years at 200 °F. The leak testing data to date suggest the GLT and GLT-S O-rings aging in the K-Area Complex (KAC) storage at temperatures of 158 °F might maintain a leak-tight seal for up to 59 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in KAC. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 24 mock-up PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

H2Fills™ [SWR-19-67]

H2FillS: Hydrogen Filling Simulation The Hydrogen Filling Simulation (H2FillS) software is a thermodynamic model designed to track and report on the transient change in hydrogen temperature, pressure, and mass flow when filling a fuel cell electric vehicle (FCEV). H2FillS simulates gas flow from the hydrogen station to the FCEV storage system. Using empirical fueling data sets, the model has been validated over a range of fueling conditions to match common light-duty FCEV fill profiles. Overall, it provides significant benefits to the light-duty fueling market and fill knowledge gaps of the interaction between a hydrogen station and an FCEV. Capabilities Use the comprehensive H2FillS model to: Safely design and operate a hydrogen fueling station Support code refinement with readily available data Develop system and operational improvements to reduce capital or operating costs at hydrogen stations or on-board FCEVs. How It Works H2FillS uses a "drag-and-drop" graphical user interface to simulate station and vehicle systems with preset parameters for common hydrogen station components as default values. When needed, users can define their own parameters to create their own station or vehicle components. Download H2FillS in Two Steps Read the terms of the end user software license agreement. Register to download the software. There are two versions of the model: A full-station model starts the simulation at high-pressure ground storage, runs through a dispenser, and ends at a vehicle storage system. A partial-station model starts at the dispenser breakaway and consists solely of the dispenser components and the vehicle storage system. H2FillS will automatically output fill performance data from the vehicle by tracking pressure and temperature throughout the fill. Users can input their own fill profiles into the model to run a variety of simulations.

Peters, Michael↗

Multiscale characterization of phase change materials for building thermal energy storage applications

Phase change materials (PCMs) store and release large amounts of thermal energy because of their high latent energy storage capacity. However, long-term cyclic stability, supercooling and performance-scalability are some of the major challenges for their use in building thermal energy storage (TES) applications. Here, in this study, we present a comprehensive multiscale characterization of two commercially available organic PCMs, Puretemp 18 and Puretemp 23. At the microscale, differential scanning calorimetry (DSC) was used to characterize phase change temperature, specific heat, and latent heat. At the mesoscale, a heat flow meter apparatus (HFMA), following the ASTM C1784 standard, was employed to measure the phase change temperature, specific heat, and latent heat properties. A comparative analysis of latent heat as a function of temperature was conducted by integrating the DSC and HFMA results. At the macroscale, the thermal performance and cyclic stability of the TES system was evaluated using Puretemp 23. The TES system consisted of a finned tube heat exchanger with a storage volume of 0.0189 m 3 (5 gal), which represents a compact, real-world TES solution suitable for building energy storage. The results showed consistent thermal stability of the PCM over 200 cycles, and the supercooling temperature remained within 0.2 °C, which was not detected in smaller-scale characterization methods. Additionally, the macroscale testing methodology of the PCM revealed that the TES is able to charge and discharge stored latent energy within 2 h under a temperature differential of 16.67 °C measured between the inlet water temperature and the phase transition temperature of the PCM. The proposed multiscale PCM characterization method provides a systematic basis for comparing important thermal storage properties while also investigating the scalability, reliability and integration challenges in large scale TES applications.

Latent heat↗

Selective consolidation of learning and memory via recall-gated plasticity

In a variety of species and behavioral contexts, learning and memory formation recruits two neural systems, with initial plasticity in one system being consolidated into the other over time. Moreover, consolidation is known to be selective; that is, some experiences are more likely to be consolidated into long-term memory than others. Here, we propose and analyze a model that captures common computational principles underlying such phenomena. The key component of this model is a mechanism by which a long-term learning and memory system prioritizes the storage of synaptic changes that are consistent with prior updates to the short-term system. This mechanism, which we refer to as recall-gated consolidation, has the effect of shielding long-term memory from spurious synaptic changes, enabling it to focus on reliable signals in the environment. We describe neural circuit implementations of this model for different types of learning problems, including supervised learning, reinforcement learning, and autoassociative memory storage. These implementations involve synaptic plasticity rules modulated by factors such as prediction accuracy, decision confidence, or familiarity. We then develop an analytical theory of the learning and memory performance of the model, in comparison to alternatives relying only on synapse-local consolidation mechanisms. We find that recall-gated consolidation provides significant advantages, substantially amplifying the signal-to-noise ratio with which memories can be stored in noisy environments. We show that recall-gated consolidation gives rise to a number of phenomena that are present in behavioral learning paradigms, including spaced learning effects, task-dependent rates of consolidation, and differing neural representations in short- and long-term pathways.

59 BASIC BIOLOGICAL SCIENCES↗

Selective consolidation of learning and memory via recall-gated plasticity

In a variety of species and behavioral contexts, learning and memory formation recruits two neural systems, with initial plasticity in one system being consolidated into the other over time. Moreover, consolidation is known to be selective; that is, some experiences are more likely to be consolidated into long-term memory than others. Here, we propose and analyze a model that captures common computational principles underlying such phenomena. The key component of this model is a mechanism by which a long-term learning and memory system prioritizes the storage of synaptic changes that are consistent with prior updates to the short-term system. This mechanism, which we refer to as recall-gated consolidation, has the effect of shielding long-term memory from spurious synaptic changes, enabling it to focus on reliable signals in the environment. We describe neural circuit implementations of this model for different types of learning problems, including supervised learning, reinforcement learning, and autoassociative memory storage. These implementations involve synaptic plasticity rules modulated by factors such as prediction accuracy, decision confidence, or familiarity. We then develop an analytical theory of the learning and memory performance of the model, in comparison to alternatives relying only on synapse-local consolidation mechanisms. We find that recall-gated consolidation provides significant advantages, substantially amplifying the signal-to-noise ratio with which memories can be stored in noisy environments. We show that recall-gated consolidation gives rise to a number of phenomena that are present in behavioral learning paradigms, including spaced learning effects, task-dependent rates of consolidation, and differing neural representations in short- and long-term pathways.

Lindsey, Jack W. (ORCID:0000000309307327)↗

CO 2 Storage prospeCtive Resource Estimation Excel aNalysis (CO 2 -SCREEN) User’s Manual: Python_V4.1

This user’s manual guides the use of the National Energy Technology Laboratory’s (NETL) CO 2 Storage prospeCtive Resource Estimation Excel aNalysis (CO 2 -SCREEN) tool, which was developed to aid users in screening geologic formations for prospective CO 2 storage resources. This manual is specific to the CO 2 -SCREEN 4.1 version which is based in Python. The 4.1 version of CO 2 -SCREEN adds in newly updated storage efficiency factors for saline formations. CO 2 -SCREEN applies U.S. Department of Energy (DOE) methods and equations for estimating prospective CO 2 storage resources for saline formations, shale formations, and residual oil zones (ROZ). CO 2 -SCREEN was developed to be substantive and user-friendly and provide a consistent method for calculating prospective CO 2 storage resources. CO 2 -SCREEN uses a Java- based graphical user interface (GUI) for data inputs and uses Python to calculate prospective CO 2 storage resources.

54 ENVIRONMENTAL SCIENCES↗

Effect of stereochemistry on nanoscale assembly of ABA triblock copolymers with crystallizable blocks

We report on the nanoscale assembly of poly(lactic acid)-b-poly(ethylene oxide)-b-poly(lactic acid) (PLA-PEO-PLA) triblock copolymers in water, focusing on the effect of stereochemistry, where the PLA blocks are statistical copolymers of l-lactide and d-lactide with l/d ratios of 100/0, 95/5, 90/10, 85/15, 75/25, and 50/50. Small-angle neutron scattering (SANS) shows a nearly constant d-spacing as concentration varies in triblock systems with l/d ratios of 90/10 and 95/5, which we attribute to inhomogeneity in the structure of these gels, supported by previous USANS and confocal microscopy studies. The SANS data fit well to a core-shell ellipsoid form factor model with a hard-sphere structure factor. Polymeric micelles with l/d ratios from 75/25 to 85/15 displayed very high aggregation numbers, consistent with a strong interaction between PLA chains and the enhanced storage modulus observed in rheological studies of these systems. While the 90/10 and 95/5 samples showed lower aggregation numbers, their SANS profiles shows close spacing between micelles, which may promote a high fraction of intermicellar bridging chains, also consistent with a higher storage modulus. Overall, these results provide insight into the micellar assembly behavior of block copolymers with a crystallizable block, and indicate that tuning stereochemistry of PLA-based block copolymers is an effective means of modifying micellar properties for specific applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reservoir Lining for Pumped Storage Hydropower: Scoping Study of Geomembrane Lining Systems

This report summarizes the results of a scoping study performed to research the use of geomembrane lining systems for pumped storage hydropower (PSH) reservoirs. The study consisted of a literature review for pertinent and publicly available information about geomembrane lining materials and their use in dams, reservoirs, and PSH as well as an assessment of the applicability of geomembrane lining systems to PSH reservoirs.

13 HYDRO ENERGY↗