Search NASA⌕ Search

SEARCH · Search NASA

Results for “sub-micron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Printed Targets with Micron-Scale Feature Patterns for the Study of Ablator Defects on OMEGA

As per present models, laser imprint and implosion symmetry are insufficient to account for observed performance degradation of direct-drive cryogenic fusion implosions. More and better data are needed on ablator defects as a source of hydrodynamic instability and mix. To investigate this, a series of OMEGA experimental campaigns is underway to study isolated target defects. Key requirements are systematic variation of the laser intensity and pulse shape at shot, with highly controlled defect type, geometry, and location. Here, given the need for sub-micron resolution and precise registration of multiple features, two-photon polymerization (TPP) printing was identified as an ideal method to fabricate these targets. TPP printing has enabled controlled formation of designed domes, divots, and vacuoles for studying the combined effect of size and proximity of these features on the hydro performance.

Two-photon polymerization printing↗

CuCr 2 O 4 particle growth and evolution across sol–gel routes and calcination profiles

CuCr 2 O 4 spinel is a candidate coating material for central receivers in concentrating solar power to protect structural alloys against high temperature oxidation and related degradation. Coating performance and microstructure of dip-coated and sintered coatings is dictated by the initial particle size of the CuCr 2 O 4 and sintering temperature, but can be compromised by particle agglomeration. Here in this study, sub-micron particles were synthesised through the Pechini and modified Pechini sol–gel methods. Phase composition was confirmed via X-ray diffraction. Particle growth during calcination of the nanoparticles at different temperatures (650°C, 750°C, 850°C) and times (between 1 and 24 h) was measured via laser diffraction and scanning electron microscopy. The modified Pechini method displayed evidence of smaller particle sizes and greater agglomeration. The kinetics of particle growth observed are consistent with a diffusion limited inhibited grain growth model.

36 MATERIALS SCIENCE↗

High-resolution in-beam video rate imaging with the ClearXCam for synchrotron beamlines

The ClearXCam detector is a new video rate imaging in-beam monitor based on a diamond sensor. Imaging with 2304 effective pixels is achieved by sequentially biasing one of 48 metal stripes on one side of a diamond sensor, while reading out the current from 48 stripes on the other side of the sensor. This system was characterized for real-time X-ray beam diagnostics at synchrotron beam­line 17-BM at the National Synchrotron Light Source II. Significant results include: detection of in-beam structure via the imaging mode, beam focusing in one minute with real-time imaging feedback during a focusing event, linearity over five orders of magnitude, validation of a fast mode operating at 100 Hz, and sub-micron beam-positioning resolution. The system is now available commercially.

36 MATERIALS SCIENCE↗

Physical properties, internal structure, and the three‐dimensional petrography of CI chondrites

physical properties and the nature of their breccation, we investigated nine samples of the Ivuna and Orgueil CI chondrites ranging in size from 1 mm to 4 cm in approximate diameter. The combined mass of unique material investigated in this work is 113 g. For our investigations, we use ideal gas pycnometry, 3-D laser scanning, x-ray computed microtomography (μCT), and accompanying digital data extraction techniques. We found that the bulk density of the samples ranged from 1.61 to 2.10 g cm −3 . Larger samples tend to have a lower bulk density. Grain density (ranging from 2.44 to 2.55 g cm −3 ) is significantly less variable than the bulk density in our samples and the quantity of porosity (ranging from 14.6% to 33.8%) is the dominant factor in determining the bulk density of CI chondrite material. Our μCT results show that the visible porosity across all sizes of our CI chondrite samples is in the form of cracks, but these cracks can account for less than two-thirds of the porosity in the CI chondrites. Other porosity is not visible, even at μCT resolutions of 2.7 μm voxel edge −1 and we conclude that it is sub-micron in nature. It is not clear if the cracks seen in our samples are indigenous to the chondrites or are a result of terrestrial processes. We also find that the CI chondrites are excellent examples of the fractal-like nature of brecciation, where clasts can be observed at all scales we imaged. The breccias are composed of sub-equant-shaped and sub-rounded-textured clasts like melt-free impact breccias on other solar system bodies. From our μCT volume and digital data extraction, we determine that the Ivuna CI chondrite breccia is organized: the mostly sub-equant clasts within our ~2 cm chunk of Ivuna have a mean diameter of 1.33 mm and their aligned longest axes define a lineation structure. We speculate that the lineation was imparted after fragmentation of the clasts by slight shear on the parent asteroid which could be the result of seismic-related granular flow or mild non-axial impact-related compaction. These data will help to place returned asteroidal material from asteroids 162173 Ryugu and 101955 Bennu and the CI chondrites into a mutual geological context.

CI chondrite↗

Vertical-cavity surface-emitting phase shifter

This study proposes a novel technique for a 2D beam steering system using hybrid plasmonic phase shifters with a cylindrical configuration in a 2D periodic array suitable for LIDAR applications. A nanoscale VCSEP design facilitates a sub-wavelength spacing between individual phase shifters, yielding an expanded field of view and side lobes suppression. The proposed design includes a highly doped sub-micron silicon pillar covered by a thin layer of nonlinear material and an additional conductive metal layer. Characterization of a single VCSEP demonstrated a Free Spectral Range (FSR) of 53.28 ± 2.5 nm and a transmission variation of 3 dB, with V π L equal to 0.075 V-mm.

47 OTHER INSTRUMENTATION↗

Tunable and efficient ultraviolet generation with periodically poled lithium niobate

On-chip ultraviolet (UV) sources are of great interest for building compact and scalable atomic clocks, quantum computers, and spectrometers. However, few material platforms are suitable for integrated UV light generation and manipulation. Of these materials, thin-film lithium niobate offers unique advantages such as sub-micron modal confinement, strong nonlinearity, and quasi-phase matching. Despite these characteristics, its utilization in the UV has remained elusive because of the substantial sensitivity of standard quasi-phase matching to fabrication imperfections, the photorefractive effect, and relatively large losses in this range. Here, we present efficient (197 ± 5%/W/cm 2 ) second harmonic generation of UV-A light in a periodically poled lithium niobate nanophotonic waveguide. We achieve on-chip UV powers of ~30 µW and linear wavelength tunability using temperature. These results are enabled with large cross section waveguides, which leads to first-order UV quasi-phase-matching with relatively long poling periods (>1.5 µm). By varying the poling period, we have achieved the shortest reported wavelength (355 nm) generated through frequency doubling in thin-film lithium niobate. Furthermore, our results open up new avenues for UV on-chip sources and chip-scale photonics through compact frequency-doubling of common near-IR laser diodes.

42 ENGINEERING↗

Dry etching of epitaxial InGaAs/InAlAs/InAlGaAs structures for fabrication of photonic integrated circuits

A dry etching process to transfer the pattern of a photonic integrated circuit design for high-speed laser communications is described. The laser stack under consideration is a 3.2-µm-thick InGaAs/InAlAs/InAlGaAs epitaxial structure grown by molecular beam epitaxy. The etching was performed using Cl2-based inductively-coupled-plasma and reactive-ion-etching (ICP-RIE) reactors. Four different recipes are presented in two similar ICP-RIE reactors, with special attention paid to the etched features formed with various hard mask compositions, in-situ passivations, and process temperatures. The results indicate that it is possible to produce high-aspect-ratio features with sub-micron separation on this multilayer structure. Additionally, the results of the etching highlight the tradeoffs involved with the corresponding recipes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The EIC accelerator: design highlights and project status

The design of the electron-ion collider (EIC) at Brookhaven National Laboratory is well underway, aiming at a peak electron-proton luminosity of 10e+34 cm^-1·sec^-1. This high luminosity, the wide center-of-mass energy range from 29 to 141 GeV (e-p) and the high level of polarization require innovative solutions to maximize the performance of the machine, which makes the EIC one of the most challenging accelerator projects to date. The complexity of the EIC will be discussed, and the project status and plans will be presented.

43 PARTICLE ACCELERATORS↗

RESONANT MATCHING SECTION FOR CEBAF ENERGY UPGRADE

In order to prevent emittance growth during long stores of the proton beam at the future Electron-Ion Collider (EIC), we need to have some mechanism to provide fast cooling of the dense proton beams. One promising method is coherent electron cooling (CeC), which uses an electron beam to both ?measure? the positions of protons within the bunch and then apply energy kicks which tend to reduce their longitudinal and transverse actions. In this work, we discuss the under- lying physics of this process. We then discuss simulations which constrain the electrons to move only longitudinally in order to perform fast optimizations and long-term track- ing of the bunch evolution, and benchmark these results against fully 3D codes. Additionally, we discuss practical challenges, including the necessity of a high-quality elec- tron beam and sub-micron alignment of the electrons and protons.

Deitrick, K.↗

Storage and Diffusion of Carbon and Nitrogen in Crustal Materials

Nitrogen is a primary constituent of Earth’s atmosphere and an essential component of many biological processes. Recent developments in understanding N incorporation into silicate minerals suggest that the solid earth and lithosphere could provide a substantial reservoir for the planetary N budget. Furthermore, determining the concentration and distribution of low abundances of N in silicates presents a significant challenge in microanalysis. We tested capabilities for high spatial resolution quantification of low levels of N using EPMA with the goal of developing standards to be used in coupled N and noble gas analyses of silicate minerals. We investigated the concentration and distribution of N in a suite of ammonium-bearing silicate minerals that reflect the dominant N-bearing phases of the lithosphere: tobelite, buddingtonite, ammonioleucite, tsaregorodtsevite, and hyalophane. These minerals form during NH 4 -rich alteration of K-bearing silicate minerals, and the bonding environment of N in each mineral is likely to differ based on crystal structure. Using an optimized analytical routine for N quantification enables sensitivity approaching 0.02 weight% N and high-resolution quantitative mapping of sub-micron variations in N contents.

58 GEOSCIENCES↗

Rapid Fabrication of High Frame Rate Multichannel FTIR Spectrometers

Spectrally resolved signals in the short- to mid-wave infrared (SWIR/MWIR) bands at high-temporal resolution are critical for many national security remote sensing missions. Currently available off the shelf technology can achieve either high temporal resolution or high spectral resolution, but rugged instruments that can achieve both simultaneously remain mostly in the realm of one-off R&D projects. This report documents efforts to demonstrate a new technique for designing and building high resolution, high framerate multichannel FTIR (MC-FTIR) spectrometers that operate in the SWIR/MWIR bands. The core optical element in a MC-FTIR spectrometer is an array of statically-tuned lamellar grating interferometers (LGI). In the original MC-FTIR work these arrays were fabricated using a synchrotron x-ray lithography method. We proposed to instead fabricate these LGI arrays using multiphoton lithography (MPL), a 3D printing technique that can fabricate meso-scale structures with sub-micron precision. Although we were able to fabricate LGI arrays of sufficient size using MPL, the realized optical surfaces had unsuitably high optical form errors, precluding their use in a fieldable instrument. Further advancement in MPL technology may eventually enable fabrication of interferometer-grade LGI arrays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Machine Learning for Predictive Performance Analysis in Charged Particle Beam Tools

Imaging methods driven by probes, electrons, and ions have played a dominant role in modern science and engineering. Opportunities for machine vision and AI that focus on consumer problems like driving and feature recognition, are now presenting themselves for automating aspects of the scientific processes. This proposal aims to enable and drive discovery in ultra-low energy implantation by taking advantage of faster processing, flexible control and detection methods, and architecture-agnostic workflows that will result in higher efficiency and shorter scientific development cycles. Custom microscope control, collection and analysis hardware will provide a framework for conducting novel in situ experiments revealing unprecedented insight into surface dynamics at the nanoscale. Ion implantation is a key capability for the semiconductor industry. As devices shrink, novel materials enter the manufacturing line, and quantum technologies transition to being more mainstream. Traditional implantation methods fall short in terms of energy, ion species, and positional precision. Here we demonstrate 1 keV focused ion beam Au implantation into Si and validate the results via atom probe tomography. We show the Au implant depth at 1 keV is 0.8 nm and that identical results for low energy ion implants can be achieved by either lowering the column voltage, or decelerating ions using bias – while maintaining a sub-micron beam focus. We compare our experimental results to static calculations using SRIM and dynamic calculations using binary collision approximation codes TRIDYN and IMSIL. A large discrepancy between the static and dynamic simulation is found that is due to lattice enrichment with high stopping power Au and surface sputtering. Additionally, we demonstrate how model details are particularly important to the simulation of these low-energy heavy-ion implantations. Finally, we discuss how our results pave a way to much lower implantation energies, while maintaining high spatial resolution.

47 OTHER INSTRUMENTATION↗

Final Technical Report - Rapid Surface Microanalysis using a Low Temperature Plasma

This project focused on improving our current understanding and scientific knowledge in the area of plasma-surface interactions and plasma assisted material synthesis related to advanced microelectronics and nanotechnology. Current challenges include: controlling the interaction of Low Temperature Plasma (LTP) with a single layer of atoms to manufacture integrated circuits, continued miniaturization of integrated circuits, LTP processing of material surfaces and thin films to enable industrial scale fabrication of advanced microelectronics, synthesis of new materials, nanomaterials, nanotubes, and complex materials, Technology developed in this subtopic is of value to either (i) enable scans of surfaces (~1 sq. cm area) using various microscopies (electron, optical, other) at high resolution (micron or sub-micron resolution) rapidly (hours or days rather than years to complete a high-resolution scan of such a large surface area), or (ii) enable scans of surfaces (~1 sq. cm area) using various microscopies (electron, optical, other) at relatively low resolution rapidly, then apply algorithms to select spots for micron-scale imaging. Sputtering occurs when particles of a solid material are ejected from its surface by energetic particles from a plasma. While the degradation of the solid material and the subsequent deposition of the ejected material onto vulnerable surfaces are the usual subjects of sputtering studies, plasma science has yet to be combined with sputtering to create new diagnostics devices and systems. Small changes in the design of the plasma discharge device make it possible to create broad plasma beams for rapid scanning or small plasma beams to obtain the distribution of ejected elements with micron resolution. In the high-resolution use, the ion flux is extracted from the gas-discharge plasma and focused by a spherical emission surface to micron sizes onto the target specimen, providing very local sputtering and local elemental analysis. We call this “self-focusing”. The radiation from the excited and ionized sputtered atoms is recorded by a spectrometer through a window and fiberglass cable and analyzed with standard software packages used for optical glow discharge spectroscopy. Computer simulations of beam formation were used to verify and optimize the designs to be tested. A prototype was designed, constructed, and used to start experiments of beam formation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of carbonaceous aerosols during TRACER-CAT

Absorbing aerosols (AA) have an important impact on the global radiation budget and cloud properties. The composition and properties of AA can vary substantially throughout the atmosphere, depending on the particle source and the influence of chemical aging. Uncertainties associated with the radiative effects of AA remain substantial. A key contributor to this uncertainty is understanding the extent to which coatings in general, and water uptake especially, alters absorption by AA particles and how this depends on particle composition. We deployed new and existing experimental tools during the Tracking Aerosol Convection Interactions Experiment (TRACER) campaign in Houston, TX as part of the Carbonaceous Aerosols Thrust (CAT) to provide detailed characterization of aerosol optical, chemical, and physical properties. Our TRACER-CAT measurements complemented and expanded on the planned TRACER instrumentation, allowing for more detailed characterization of aerosol properties of relevance to cloud development (a core focus of TRACER), such as the composition of particles that can act as cloud condensation nuclei, than would otherwise be available. Our measurements have allowed for assessment of the relationship(s) between AA optical properties (with a focus on absorption) and the chemical and physical characteristics (including the mixing state of black carbon (BC) containing particles). These field observations occurred in collaboration with Los Alamos National Laboratory in summer 2022 during the TRACER intensive operating period. The instrumentation we co-deployed provided for measurement of (i) multi-wavelength dry aerosol absorption, scattering, and extinction, (ii) the size-dependent composition and abundance of sub-micron aerosol, differentiating between those particles that do and do not contain BC, (iii) BC-specific concentrations and size distributions, (iv) particle size, and (v) the first field measurements at an ARM site of the influence of RH on multi-wavelength absorption by ambient AA. We have leveraged the natural variability of the atmosphere and of aerosol sources in the Houston region to (i) specifically disentangle contributions to light absorption from BC, absorbing organic carbon (brown carbon), and coatings on BC, (ii) characterize the mixing state of BC and assess the factors that give rise to compositional differences between BC-containing and BC-free aerosol, and (iii) establish how water uptake influences absorption and how any such effect depends on particle composition and BC mixing state. Overall, our study contributed to the mission of the Atmospheric System Research program in multiple ways. Through the deployment of complementary, advanced instrumentation for characterization of a wide range of aerosol properties our work helped to maximize the scientific impact of the TRACER campaign. Our work also allowed for development of new insights into the relationship(s) between aerosol composition, hygroscopicity, and the mixing state of BC with aerosol optical properties. Through this, our work has provided knowledge that can improve understanding and model representation of aerosol processes as they affect the Earth’s radiation budget.

54 ENVIRONMENTAL SCIENCES↗

Effects of Focused Ion Beam Lithography on La 2– x Sr x CuO 4 Single Crystals

Focused ion beam (FIB) milling is a mask-free lithography technique that allows the precise shaping of 3D materials on the micron and sub-micron scale. The recent discovery of electronic nematicity in La 2–x Sr x CuO 4 (LSCO) thin films triggered the search for the same phenomenon in bulk LSCO crystals. With this motivation, we have systematically explored FIB patterning of bulk LSCO crystals into micro-devices suitable for longitudinal and transverse resistivity measurements. We found that several detrimental factors can affect the result, ultimately compromising the possibility of effectively using FIB milling to fabricate sub-micrometer LSCO devices, especially in the underdoped regime.

36 MATERIALS SCIENCE↗

Measurement and Simulation of Ultra-Low-Energy Ion–Solid Interaction Dynamics

Ion implantation is a key capability for the semiconductor industry. As devices shrink, novel materials enter the manufacturing line, and quantum technologies transition to being more mainstream. Traditional implantation methods fall short in terms of energy, ion species, and positional precision. Here, we demonstrate 1 keV focused ion beam Au implantation into Si and validate the results via atom probe tomography. We show the Au implant depth at 1 keV is 0.8 nm and that identical results for low-energy ion implants can be achieved by either lowering the column voltage or decelerating ions using bias while maintaining a sub-micron beam focus. We compare our experimental results to static calculations using SRIM and dynamic calculations using binary collision approximation codes TRIDYN and IMSIL. A large discrepancy between the static and dynamic simulation is found, which is due to lattice enrichment with high-stopping-power Au and surface sputtering. Additionally, we demonstrate how model details are particularly important to the simulation of these low-energy heavy-ion implantations. Finally, we discuss how our results pave a way towards much lower implantation energies while maintaining high spatial resolution.

36 MATERIALS SCIENCE↗

Development of mesopores in superfine grain graphite neutron-irradiated at high fluence

Microstructural changes induced by neutron irradiation of superfine grain graphite G347A (Tokai Carbon, Japan) were examined by nitrogen adsorption at 77K and by three microscopy techniques (SEM, TEM and FIB-SEM tomography). The specimens were irradiated at doses of up to 30 dpa, covering stages before and after the turnaround fluence at three temperatures (300, 450, 750 °C) of their irradiation envelope. The initial graphite densification at low fluences did not produce any detectable effect in the pore size range (<350 nm) measured by gas adsorption. However, graphite irradiated at high fluences, after turnaround, showed severe structural changes. At all three temperatures and high irradiation fluences, gas adsorption revealed significant increase of the volume of narrow mesopores (<5–20nm) and up to five times increase of BET surface area, both in linear relationship with the relative volume expansion. Analysis of microscopy images showed multiplication of fine macropores (>50 nm) at high irradiation fluences and more structural changes on multiple scales, from nanometers to microns. This work demonstrates the unique ability of gas adsorption techniques to analyze open pores with sizes between sub-nanometer and sub-micron in bulk nuclear graphite, with supporting microscopy results.

I. Contescu, Cristian↗

ARM Aerial Facility (AAF) Water-based Condensation Particle Counter

The condensation particle counter (CPC) measures sub-micron aerosol particle number concentration by condensing fluid onto particles and causing them to grow to sizes that are easily detectable by optical scattering. The condensing liquid is typically an alcohol (e.g., butanol) or water. Depending on the CPC type, typical CPC instruments can count particles with sizes that range from 3 to 3000 nanometers (ultrafine CPC) or from 10 to 3000 nanometers (fine CPC).

54 ENVIRONMENTAL SCIENCES↗