Search NASA⌕ Search

SEARCH · Search NASA

Results for “subcritical experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Neutron Noise Analysis of the Neptunium Subcritical Observation (NESO) Experiment

The Neptunium Subcritical Observation (NeSO) experiment was a subcritical integral benchmark experiment. This experiment was designed in 2017-2018 and was performed at the National Criticality Experiments Research Center (NCERC) in 2019. Eight different subcritical configurations were measured with varying Nickel reflector thickness. For all configurations, a 3 He detection system was used to record neutron events. The focus of this work is to share neutron noise results of the measured data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Noise Analysis of the Neptunium Subcritical Observation (NESO) Experiment

The Neptunium Subcritical Observation (NeSO) experiment was a subcritical integral benchmark experiment. This experiment was designed in 2017-2018 and was performed at the National Criticality Experiments Research Center (NCERC) in 2019. Eight different subcritical configurations were measured with varying Nickel reflector thickness. For all configurations, a 3 He detection system was used to record neutron events. The focus of this work is to share neutron noise results of the measured data.

3-Helium↗

Stability of quasi-Keplerian shear flow in a laboratory experiment

Subcritical transition to turbulence has been proposed as a source of turbulent viscosity required for the associated angular momentum transport for fast accretion in Keplerian disks. Previously cited laboratory experiments in supporting this hypothesis were performed either in a different type of flow than Keplerian or without quantitative measurements of angular momentum transport and mean flow profile, and all of them appear to suffer from Ekman effects, secondary flows induced by nonoptimal axial boundary conditions. Such Ekman effects are expected to be absent from astronomical disks, which probably have stress-free vertical boundaries unless strongly magnetized. To quantify angular momentum transport due to subcritical hydrodynamic turbulence, if exists, in a quasi-Keplerian flow with minimized Ekman effects. We perform a local measurement of the azimuthal–radial component of the Reynolds stress tensor in a novel laboratory apparatus where Ekman effects are minimized by flexible control of axial boundary conditions. We find significant Ekman effects on angular momentum transport due to nonoptimal axial boundary conditions in quasi-Keplerian flows. With the optimal control of Ekman effects, no statistically meaningful angular momentum transport is detected in such flows at Reynolds number up to two millions. Either a subcritical transition does not occur, or, if a subcritical transition does occur, the associated radial transport of angular momentum in optimized quasi-Keplerian laboratory flows is too small to directly support the hypothesis that subcritical hydrodynamic turbulence is responsible for accretion in astrophysical disks. Possible limitations in applying laboratory results to astrophysical disks due to experimental geometry are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Primary Assessment Technologies FY2017 Milestone Report: NDSE Development Using DPF

A new diagnostic technique for a neutron-based measurement of dynamic subcritical experiments is currently under development. The technique, referred to as a Neutron Diagnosed Subcritical Experiment (NDSE), requires that a short intense burst of neutrons be directed into a subcritical fissile object and a precision measurement of the emitted fission gamma rays be made as a function of time. Recent advances in a dense plasma neutron source and gamma ray detectors have been integrated together at the Nevada National Security Site to provide a NDSE technique development and testing capability. The first set of NDSE demonstration experiments have now been completed using static objects constructed with large quantities of highly enriched uranium. The acquired data reveal the expected sensitivity to changes in neutronic properties of fissile objects and illustrate that the diagnostic approach is viable. As expected for any new measurement technique, many areas for improvement have been identified during static object testing and continued maturation of the diagnostic is planned before implementation on a dynamic subcritical experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Some experience using subcritical response methods in wind-tunnel flutter model studies

Experiences obtained with four methods of predicting flutter of wind-tunnel models from subcritical response data are described. The four methods are: co/quad, randomdec, power spectra density, and the peak-hold spectrum. Model excitation techniques included both forced (sinusoidal sweep) and random (tunnel turbulence). These methods were successfully used to measure the frequency and damping (or an inverse response amplitude proportional to the damping) in the predominant flutter modes. Implementation and application of each method are discussed. Some results and comparisons between methods are presented.

Foughner, J. T., Jr.↗

A Procedure for Evaluating Modified Pulsed-Neutron- Source Experiments in Subcritical Nuclear Reactors

A theoretical interpretation of the modified pulsed-neutron-source experiments of Sjöstrand, Gozani, and Garelis and Russell is given using exact steady-state Boltzmann equations. Here, interpretation is based on a phenomenological description of the experiments and is patterned after work done on the Garelis-Russell method by Corngold. The basic approximation made is that the fundamental prompt-mode decay constant is much larger than any delayed-neutron precursor decay constant. The theoretical interpretation allows the reactivities measured by the above three modified pulsed-source techniques to be easily calculated and compared to more conventional definitions of reactivity. The calculations can be performed by any standard source-iteration code that has been modified to solve the inhomogeneous problem. Experiments were performed on the Cornell University Critical Assembly and interpreted with the aid of the above theory. Calculations and experiments agree to within 20%. Sjöstrand's method is found to give the best result for this reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Spatial and spectral effects in subcritical system pulsed experiments

Accurate neutronic models are needed for the interpretation of pulsed experiments in subcritical systems. In this work, the extent of spatial and spectral effects in the pulse propagation phenomena is investigated and the analysis is applied to the GUINEVERE experiment. The multigroup cross section data is generated by the Monte Carlo SERPENT code and the neutronic evolution following the source pulse is simulated by a kinetic diffusion code. The results presented show that important spatial and spectral aspects need to be properly accounted for and that a detailed energy approach may be needed to adequately capture the physical features of the system to the pulse injection. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comprehensive Experiments on Subcritical Assemblies of Cascade Reactor Systems

Cascade reactors attract particular attention because of their capability of improving the parameters of pulsed reactors and achieving the feasibility of electronuclear facilities. The paper presents the results of three series of experiments on uranium-neptunium cascade assemblies at the Institute of Nuclear and Radiation Physics of the All-Russian Research Institute of Experimental Physics conducted in 2003–2004. The experiments confirmed theoretical conclusions on positive properties of cascade blankets and effectiveness of using neptunium-237 as a means of creating a one-sided connection between the sections.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SHOCKED SURFACE STEREO IMAGING WITH FIBER-OPTIC IMAGING PROBES

“A picture tells a thousand words”—this is a concept that captivates everyone, from the casual observer to the experimental physics scientist. To bring this concept to light in support of Stockpile Stewardship subcritical experiments executed at the Nevada National Security Site (NNSS), we have developed a new diagnostic tool to investigate the behavior of materials under high-explosive dynamic shock conditions. For the Leda subcritical experiment executed in August, 2014, a single line-of-sight imaging system was designed and fielded as a stretch diagnostic goal for National Security Technologies, LLC (NSTec). For the Lyra series, beginning with the Orpheus experiment in September 2015, a newly created dynamic stereo surface imaging (DSSI) capability was deployed. The DSSI diagnostic records a high-speed image sequence that allows scientists to peer inside an imploding hydrodynamic test article with stereoscopic imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DPF Test Conditions: FY 2016

A Neutron Diagnosed Subcritical Experiment (NDSE) is designed to quantitatively measure the reactivity of a subcritical (k eff <1.0) plutonium experiment and thereby improve our understanding of primary performance in the absence of underground nuclear testing. Successful implementation of this diagnostic requires a short, intense burst of neutrons be delivered to the fissile assembly at a precise time during a plutonium implosion. Monte Carlo particle transport simulations of representative subcritical experiments have been performed to establish the pulse shape, flux, and timing requirements for the NDSE neutron source. Additional requirements have also been established for detector sensitivity, acceptable background levels, and total diagnostic reliability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical experiments on subcritical transition mechanisms

A spectral algorithm for simulating three-dimensional, incompressible, parallel shear flows is described. It applies to the channel, to the parallel boundary layer, and to other shear flows with one wall-bounded and two periodic directions. Simulations performed for the channel identify the one nonlinear interaction which is crucial to the secondary instability. Moreover, it is shown that subharmonic instability ensues for Reynolds numbers as low as 1500. Simulations performed for the heated water boundary layer reveal the operation of the secondary instability in this controlled flow.

Zang, T. A.↗

Benchmark Analysis of Subcritical Noise Measurements on a Nickel-Reflected Plutonium Metal Sphere

Subcritical experiments using californium source-driven noise analysis (CSDNA) and Feynman variance-to-mean methods were performed with an alpha-phase plutonium sphere reflected by nickel shells, up to a maximum thickness of 7.62 cm. Both methods provide means of determining the subcritical multiplication of a system containing nuclear material. A benchmark analysis of the experiments was performed for inclusion in the 2010 edition of the International Handbook of Evaluated Criticality Safety Benchmark Experiments. Benchmark models have been developed that represent these subcritical experiments. An analysis of the computed eigenvalues and the uncertainty in the experiment and methods was performed. The eigenvalues computed using the CSDNA method were very close to those calculated using MCNP5; however, computed eigenvalues are used in the analysis of the CSDNA method. Independent calculations using KENO-VI provided similar eigenvalues to those determined using the CSDNA method and MCNP5. A slight trend with increasing nickel-reflector thickness was seen when comparing MCNP5 and KENO-VI results. For the 1.27-cm-thick configuration the MCNP eigenvalue was approximately 300 pcm greater. The calculated KENO eigenvalue was about 300 pcm greater for the 7.62-cm-thick configuration. The calculated results were approximately the same for a 5-cm-thick shell. The eigenvalues determined using the Feynman method are up to approximately 2.5% lower than those determined using either the CSDNA method or the Monte Carlo codes. The uncertainty in the results from either method was not large enough to account for the bias between the two experimental methods. An ongoing investigation is being performed to assess what potential uncertainties and/or biases exist that have yet to be properly accounted for. The dominant uncertainty in the CSDNA analysis was the uncertainty in selecting a neutron cross-section library for performing the analysis of the data. The uncertainty in the Feynman method was equally shared between the uncertainties in fitting the data to the Feynman equations and the neutron multiplicity of 239 Pu. Material and geometry uncertainties in the benchmark experiment were generally much smaller than uncertainties in the analysis methods.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fast-Spectrum Critical Assemblies with a Pb-HEU Core Surrounded by a Copper Reflector

The Department of Energy invests tens of millions of dollars each year to develop the next generation of nuclear engineering modeling & simulation (M&S) tools. These M&S tools are used to analyze advanced reactor designs and the safety of current nuclear operations. As computers become more powerful, we are able to enhance resolution in our calculations. This improved resolution is taking us to a point where the limitations of simulation capability are in the quality of data, including our ability to quantify the uncertainty and sensitivity of the data. In order to accurately model systems of interest, the industry must improve key nuclear data measurements and our confidence of how well we understand the data. Thus, M&S tools need evaluated and quality-assured experimental data for validation purposes. The International Criticality Safety Benchmark Evaluation Project (ICSBEP) compiles benchmark experiment data in a handbook that can be used by criticality safety engineers to validate computer codes and cross-section libraries at nuclear facilities. Both critical and subcritical experiments are included in the handbook. Figure 1 organizes all the benchmark evaluations that have been performed by the isotope of interest, in this case Pb, and the neutron energy within the system. Compared to other isotopes of interest for nuclear applications, there are few benchmark evaluations for Pb systems. This has caused the latest nuclear cross-section libraries to over/underestimate changes in the neutron population compared to experimental results. Therefore, this evaluation fills an important knowledge gap in benchmark evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CGMF & FREYA Verification in MCNP6

At the present time, the new and updated fission event generators included in MCNP6.2 have been verified to be functioning properly through a variety of detailed tests. This work describes the detailed verification steps taken to ensure these complicated fission event generators, FREYA and CGMF, are integrated into MCNP6 properly. Ultimately, with the knowledge that MCNP6 is making use of these models appropriately, we can now begin to validate the models against benchmarked experiments. Some benchmarks, including criticality and subcritical experiments interested in multiplication and bulk counting rates, are easy to model and understand but are likely insensitive to the detailed nature of these models. It will take some new measurements with coincidence detection capabilities to be able to stress the physics within each of these fission event generator models. Once the models are validated and it is understood where the models can truly be predictive, then we can study what SNM observables can be characterized for nonproliferation applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dense Plasma Focus Diagnostic Suite for the Surrogate Static Test

A Neutron Diagnosed Subcritical Experiment (NDSE) has been proposed to measure the reactivity of a subcritical ($k_{eff} <$ 1:0) plutonium experiment. This experiment requires a short, high-intensity neutron pulse delivered to the target material with precise timing. A feasibility study for the NDSE is being conducted jointly by National Security Technologies, LLC, and Los Alamos National Laboratory at Area 11 of the Nevada National Security Site. The goals of this study include characterizing and developing the proposed neutron pulse source, the fast photon detection system, and the shielding system to suppress scattering backgrounds.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

IER-407 CED-3b Rev-1: Experiment Execution Report for the Inherently Safe Subcritical Assembly (ISSA) Subcritical Measurements

This set of benchmark subcritical multiplicity experiments was conducted at the ISSA experiment center of Lawrence Livermore National Laboratory. The purpose of these subcritical experiments, as described in the ISSA final design report, was to measure fission neutrons by collecting time-tagged data corresponding to a maximum multiplication of approximately 20. The fission source for this experiment was Materials Test Reactor (MTR)-type highly enriched uranium fuel assembly, which is composed of nineteen fuel plates. One, two, four, six and nine ISSA fuel assemblies were closely packed and loaded inside a support fixture assembly and immersed in water. Four 3 He proportional counters were placed around the fuel assemblies, and list-mode experimental data was taken. Additionally, efficiency calibration measurements with calibrated neutron sources were conducted. The LLNL developed codes BIGFIT and OSANTI RESTART will be used to evaluate the measured data and calculate the experimental multiplication.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of Cygnus Electrical Signals

The United States initiated the Subcritical Experiment (SCE) program to support a stockpile stewardship mission shortly after the 1992 moratorium on underground nuclear testing was established. Many SCE’s are conducted at the Nevada National Security Site (NNSS) in Nevada. Cygnus is a high-energy radiation generating device (RGD) located and operated at the NNSS and is a primary diagnostic for the SCE program. The Cygnus Dual Beam Radiographic Facility consists of two identical radiographic sources, Cygnus 1 and Cygnus 2. From creation of the high power V-I drive to energy transport and X-ray conversion at the rod-pinch diode, the Cygnus machines utilize the following components: oil-filled Marx generator, water-filled pulse-forming line (PFL), water-filled coaxial transmission line (CTL), three-cell vacuum induction voltage adder (IVA), and rod-pinch diode. The diode pulse has the following electrical specifications: 2.25 MV, 60 kA, 60 ns. Each source has the following X-ray specifications: 1 mm diameter, 4 rad at 1 m, and 50 ns radiation pulse. SCEs are both single-event and high-value; therefore, a high level of performance in reliability and reproducibility are key issues of Cygnus. Prior to executing such a SCE, there are a formidable number of shots (e.g., each of the two Cygnus RGDs charging and discharging properly into the rod-pinch diode load) that must be executed to determine reliability and reproducibility of the Cygnus RGDs. For every shot on Cygnus, voltages and currents along the machine are recorded and analyzed. In this paper we summarize attributes of the voltage and current waveforms at different locations using distribution plots. These distribution plots are used to quantify the reliability and reproducibility for Cygnus. This analysis methodology will provide a standard to trouble shoot results of individual Cygnus shots, and also to monitor long term Cygnus performance. Accordingly, this type of extensive analysis will contribute to optimized Cygnus performance on SCEs.

42 ENGINEERING↗