Search NASA⌕ Search

SEARCH · Search NASA

Results for “subset selections”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Public Participation in Earth Science from the ISS

The Gateway to Astronaut Photography of Earth (GAPE) is an online database (http://eol.jsc.nasa.gov) of terrestrial astronaut photography that enables the public to experience the astronaut s view from orbit. This database of imagery includes all NASA human-directed missions from the Mercury program of the early 1960 s to the current International Space Station (ISS). To date, the total number of images taken by astronauts is 1,025,333. Of the total, 621,316 images have been "cataloged" (image geographic center points determined and descriptive metadata added). The remaining imagery provides an opportunity for the citizen-scientist to become directly involved with NASA through cataloging of astronaut photography, while simultaneously experiencing the wonder and majesty of our home planet as seen by astronauts on board the ISS every day. We are currently developing a public cataloging interface for the GAPE website. When complete, the citizen-scientist will be able to access a selected subset of astronaut imagery. Each candidate will be required to pass a training tutorial in order to receive certification as a cataloger. The cataloger can then choose from a selection of images with basic metadata that is sorted by difficulty levels. Some guidance will be provided (template/pull down menus) for generation of geographic metadata required from the cataloger for each photograph. Each cataloger will also be able to view other contributions and further edit that metadata if they so choose. After the public inputs their metadata the images will be posted to an internal screening site. Images with similar geographic metadata and centerpoint coordinates from multiple catalogers will be reviewed by NASA JSC Crew Earth Observations (CEO) staff. Once reviewed and verified, the metadata will be entered into the GAPE database with the contributors identified by their chosen usernames as having cataloged the frame.

Willis, Kimberly J.↗

Selection of optimum frequencies for atmospheric electric path length measurement by satellite-borne microwave radiometers

Numerical experiments using regressions by leaps and bounds have been performed to determine the optimum frequencies for satellite-borne microwave radiometers to estimate atmospheric electrical path length over the sea. The frequency range 5-40 GHz was searched. The effect of surface wind speed, sea surface temperature, and clouds was considered in the optimum frequency selection. The analysis indicates that approximately 0.6-cm rms accuracy is possible for one-way path length measurement using a proper pair of frequencies. The best two-channel subset selected by the leaps and bounds techniques is (16.0, 21.0) GHz.

Pandey, P. C.↗

Impact of compressed breast thickness and dose on lesion detectability in digital mammography: FROC study with simulated lesions in real mammograms

Purpose: The aim of this work was twofold: (1) to examine whether, with standard automatic exposure control (AEC) settings that maintain pixel values in the detector constant, lesion detectability in clinical images decreases as a function of breast thickness and (2) to verify whether a new AEC setup can increase lesion detectability at larger breast thicknesses. Methods: Screening patient images, acquired on two identical digital mammography systems, were collected over a period of 2 yr. Mammograms were acquired under standard AEC conditions (part 1) and subsequently with a new AEC setup (part 2), programmed to use the standard AEC settings for compressed breast thicknesses ≤49 mm, while a relative dose increase was applied above this thickness. The images were divided into four thickness groups: T1 ≤ 29 mm, T2 = 30–49 mm, T3 = 50–69 mm, and T4 ≥ 70 mm, with each thickness group containing 130 randomly selected craniocaudal lesion-free images. Two measures of density were obtained for every image: a BI-RADS score and a map of volumetric breast density created with a software application (VolparaDensity, Matakina, NZ). This information was used to select subsets of four images, containing one image from each thickness group, matched to a (global) BI-RADS score and containing a region with the same (local) VOLPARA volumetric density value. One selected lesion (a microcalcification cluster or a mass) was simulated into each of the four images. This process was repeated so that, for a given thickness group, half the images contained a single lesion and half were lesion-free. The lesion templates created and inserted in groups T3 and T4 for the first part of the study were then inserted into the images of thickness groups T3 and T4 acquired with higher dose settings. Finally, all images were visualized using the ViewDEX software and scored by four radiologists performing a free search study. A statistical jackknife-alternative free-response receiver operating characteristic analysis was applied. Results: For part 1, the alternative free-response receiver operating characteristic curves for the four readers were 0.80, 0.65, 0.55 and 0.56 in going from T1 to T4, indicating a decrease in detectability with increasing breast thickness. P-values and the 95% confidence interval showed no significant difference for the T3-T4 comparison (p = 0.78) while all the other differences were significant (p < 0.05). Separate analysis of microcalcification clusters presented the same results while for mass detection, the only significant difference came when comparing T1 to the other thickness groups. Comparing the scores of part 1 and part 2, results for the T3 group acquired with the new AEC setup and T3 group at standard AEC doses were significantly different (p = 0.0004), indicating improved detection. For this group a subanalysis for microcalcification detection gave the same results while no significant difference was found for mass detection. Conclusions: These data using clinical images confirm results found in simple QA tests for many mammography systems that detectability falls as breast thickness increases. Results obtained with the AEC setup for constant detectability above 49 mm showed an increase in lesion detection with compressed breast thickness, bringing detectability of lesions to the same level.

60 APPLIED LIFE SCIENCES↗

An exploration of heterogeneity in supernova type Ia samples

We examine three SNe Type Ia datasets: Union2.1, JLA and Panstarrs to check their consistency using cosmology blind statistical analyses as well as cosmological parameter fitting. We find that the Panstarrs dataset is the most stable of the three to changes in the data, although it does not, at the moment, go to high enough redshifts to tightly constrain the equation of state of dark energy, w . The Union2.1, drawn from several different sources, appears to be somewhat susceptible to changes within the dataset. The JLA reconstructs well for a smaller number of cosmological parameters. At higher degrees of freedom, the dependence of its errors on redshift can lead to varying results between subsets. Panstarrs is inconsistent with the other two datasets at about 2σ confidence level, and JLA and Union2.1 are about 1σ away from each other. For the Ω{sub 0} {sub m} − w cosmological reconstruction, with no additional data, the 1σ range of values in w for selected subsets of each dataset is two times larger for JLA and Union2.1 as compared to Panstarrs. The range in Ω{sub 0} {sub m} for the same subsets remains approximately similar for all three datasets. We find that although there are differences in the fitting and correction techniques used in the different samples, the most important criterion is the selection of the SNe, a slightly different SNe selection can lead to noticeably different results both in the purely statistical analysis and in cosmological reconstruction. We note that a single, high quality low redshift sample could help decrease the uncertainties in the result. We also note that lack of homogeneity in the magnitude errors may bias the results and should either be modeled, or its effect neutralized by using other, complementary datasets. A supernova sample with high quality data at both high and low redshifts, constructed from a few surveys to avoid heterogeneity in the sample, and with homogeneous errors, would result in a more robust cosmological reconstruction.

79 ASTRONOMY AND ASTROPHYSICS↗

Bayesian and LASSO Regressions for Comparative Permeability Modeling of Sandstone Reservoirs

In this research, Bayesian model averaging (BMA) and least absolute shrinkage and selection operator regression (LASSO) algorithms were adopted for the core permeability modeling as a function of well log and core measurements. More specifically, the core permeability (dependent factor) was modeled given the well log and core data (independent variables) and then predicted in non-cored intervals of a well in a sandstone formation. The BMA is a stochastic linear modeling and a Bayesian parameter selection. Among 50 linear models generated as a function of the independent variables and depicted in Occam’s window, the best model of the highest posterior probability is determined. The best model has the optimal subset parameters that most influences the response factor. The core permeability modeling was again conducted using the LASSO algorithm, which adopts a completely different way of modeling and subset selection by using the penalized least-squared equation. Both BMA and LASSO resulted in a very accurate prediction of the core permeability by achieving perfect measured and calculated permeability matching. Matches for the two algorithms were quantified by computing the adjusted R-squared and root-mean-squared prediction error. In addition, results of the BMA and LASSO were compared to the conventional multiple linear regression (LM). The LASSO algorithm led to an accurate matching similar to LM, but slightly better than BMA. Therefore, both BMA and LASSO represent integrated procedures for accurate permeability estimation similar to conventional regression analysis.

58 GEOSCIENCES↗

TU-CD-BRA-05: Atlas Selection for Multi-Atlas-Based Image Segmentation Using Surrogate Modeling

Purpose: The growing size and heterogeneity in training atlas necessitates sophisticated schemes to identify only the most relevant atlases for the specific multi-atlas-based image segmentation problem. This study aims to develop a model to infer the inaccessible oracle geometric relevance metric from surrogate image similarity metrics, and based on such model, provide guidance to atlas selection in multi-atlas-based image segmentation. Methods: We relate the oracle geometric relevance metric in label space to the surrogate metric in image space, by a monotonically non-decreasing function with additive random perturbations. Subsequently, a surrogate’s ability to prognosticate the oracle order for atlas subset selection is quantified probabilistically. Finally, important insights and guidance are provided for the design of fusion set size, balancing the competing demands to include the most relevant atlases and to exclude the most irrelevant ones. A systematic solution is derived based on an optimization framework. Model verification and performance assessment is performed based on clinical prostate MR images. Results: The proposed surrogate model was exemplified by a linear map with normally distributed perturbation, and verified with several commonly-used surrogates, including MSD, NCC and (N)MI. The derived behaviors of different surrogates in atlas selection and their corresponding performance in ultimate label estimate were validated. The performance of NCC and (N)MI was similarly superior to MSD, with a 10% higher atlas selection probability and a segmentation performance increase in DSC by 0.10 with the first and third quartiles of (0.83, 0.89), compared to (0.81, 0.89). The derived optimal fusion set size, valued at 7/8/8/7 for MSD/NCC/MI/NMI, agreed well with the appropriate range [4, 9] from empirical observation. Conclusion: This work has developed an efficacious probabilistic model to characterize the image-based surrogate metric on atlas selection. Analytical insights lead to valid guiding principles on fusion set size design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Machine Learning Optimization of p-Type Transparent Conducting Films

p-Type transparent conducting materials (p-TCMs) are important components of optoelectronic devices including solar cells, photodetectors, displays, and flexible sensors. Cu–Zn–S thin films prepared by chemical bath deposition (CBD) can have both high transparency in the visible range (>80%) as well as excellent hole conductivity (>1000 S cm –1 ). However, the interplay between the deposition parameters in the CBD process (metal and sulfur precursor concentrations, temperature, pH, complexing agents, etc.) creates a multidimensional parameter space such that optimization for a specific application is challenging and time-consuming. Here we show that strategic design of experiment combined with machine learning (ML) allows for the efficient optimization of p-TCM performance. The approach is guided by a figure of merit (FOM) calculated from the film conductivity and optical transmission in the desired spectral range. A specific example is shown using two steps of optimization using a selected subset of four experimental CBD factors. The ML model is based on support vector regression employing a radial basis function as the kernel function. 10-fold cross-validation was performed to mitigate overfitting. After the first round of optimization, predicted areas in the parameter space with maximal FOMs were selected for a second round of optimization. Films with optimal FOMs were incorporated into heterojunction solar cells and transparent photodiodes. Here, the optimization approach shown here will be generally applicable to any materials synthesis process with multiple parameters.

14 SOLAR ENERGY↗

On the Selection of Dimension Reduction Techniques for Scientific Applications

Many dimension reduction methods have been proposed to discover the intrinsic, lower dimensional structure of a high-dimensional dataset. However, determining critical features in datasets that consist of a large number of features is still a challenge. In this paper, through a series of carefully designed experiments on real-world datasets, we investigate the performance of different dimension reduction techniques, ranging from feature subset selection to methods that transform the features into a lower dimensional space. We also discuss methods that calculate the intrinsic dimensionality of a dataset in order to understand the reduced dimension. Using several evaluation strategies, we show how these different methods can provide useful insights into the data. These comparisons enable us to provide guidance to a user on the selection of a technique for their dataset.

97 MATHEMATICS AND COMPUTING↗

Analyte separation utilizing temperature programmed desorption of a preconcentrator mesh

A method and system for controllably releasing contaminants from a contaminated porous metallic mesh by thermally desorbing and releasing a selected subset of contaminants from a contaminated mesh by rapidly raising the mesh to a pre-determined temperature step or plateau that has been chosen beforehand to preferentially desorb a particular chemical specie of interest, but not others. By providing a sufficiently long delay or dwell period in-between heating pulses, and by selecting the optimum plateau temperatures, then different contaminant species can be controllably released in well-defined batches at different times to a chemical detector in gaseous communication with the mesh. For some detectors, such as an Ion Mobility Spectrometer (IMS), separating different species in time before they enter the IMS allows the detector to have an enhanced selectivity.

Linker, Kevin L↗

Detection of 224 candidate structured RNAs by comparative analysis of specific subsets of intergenic regions

The discovery of structured non-coding RNAs (ncRNAs) in bacteria can reveal new facets of biology and biochemistry. Comparative genomics analyses executed by powerful computer algorithms have successfully been used to uncover many novel bacterial ncRNA classes in recent years. However, this general search strategy favors the discovery of more common ncRNA classes, whereas progressively rarer classes are correspondingly more difficult to identify. In the current study, we confront this problem by devising several methods to select subsets of intergenic regions that can concentrate these rare RNA classes, thereby increasing the probability that comparative sequence analysis approaches will reveal their existence. By implementing these methods, we discovered 224 novel ncRNA classes, which include ROOL RNA, an RNA class averaging 581 nt and present in multiple phyla, several highly conserved and widespread ncRNA classes with properties that suggest sophisticated biochemical functions and a multitude of putative cis-regulatory RNA classes involved in a variety of biological processes. We expect that further research on these newly found RNA classes will reveal additional aspects of novel biology, and allow for greater insights into the biochemistry performed by ncRNAs.

59 BASIC BIOLOGICAL SCIENCES↗

Method of controlling a vehicle to adjust perception system energy usage

A method of controlling a vehicle includes determining a current operating situation of the vehicle, and identifying a subset of a plurality of sensors of the vehicle needed to provide data to enable a vehicle control function for the current operating situation of the vehicle. A remainder of the plurality of sensors is disengaged to reduce electric energy usage by the vehicle while the vehicle is operating in the current operating situation of the vehicle. A sampling rate for the selected subset of sensors may be reduced to further reduce energy usage of the vehicle. Additionally, an energy reduction processing strategy may be implemented to reduce a processor frequency or a voltage of a computing device used to provide the vehicle control function to further reduce energy usage of the vehicle.

Hu, Yuxiao↗

eBits: Compact stream of mesh refinements for remote visualization

Here, we focus on applications where a remote client needs to visualize or process a complex, manifold triangle mesh, M , but only in a relatively small, user controlled, Region of Interest (RoI) at a time. The client first downloads a coarse base mesh , pre-computed on the server via a series of simplification passes on M , one per Level of Detail (LoD), each pass identifying an independent set of triangles, collapsing them, and, for each collapse, storing, in a Vertex Expansion Record (VER), the information needed to reverse the collapse. On each client initiated RoI modification request, the server pushes to the client a selected subset of these VERs, which, when decoded and applied to refine the mesh locally, ensure that the portion in the RoI is always at full resolution. The eBits approach proposed here offers state of the art compression ratios (using less than 2.5 bits per new full resolution RoI triangle when the RoI has more than 2000 vertices to transmit the connectivity for the selective refinements) and fine-grain control (allowing the user to adjust the RoI by small increments). The effectiveness of eBits results from several novel ideas and novel variations of previous solutions. We represent the VERs using persistent labels so that they can be applied in different orders within a given LoD. The server maintains a shadow copy of the client’s mesh. To avoid sending IDs identifying which vertices should be expanded, we either transmit, for each new vertex, a compact encoding of its death tag –the LoD at which it will be expanded if it lies in the Rol–or transmit vertex masks for the RoI and its neighboring vertices. We also propose a three-step simplification that reduces the overall transmission cost by increasing both the simplification effectiveness and the regularity of the valences in the resulting meshes.

97 MATHEMATICS AND COMPUTING↗

Measurements of OC and EC in coarse particulate matter in the southeastern United States

The organic carbon (OC) and elemental carbon (EC) content of filter-based, 24-hr integrated particulate matter with aerodynamic diameters between 2.5 and 10 {mu}m (PM10-2.5) was measured at two urban and two rural locations in the southeastern United States. On average, total carbon (OC + EC) comprised approximately 30% of PM10-2.5 mass at these four sites. Carbonate carbon was measured on a subset of samples from three sites and was found to be undetectable at a rural site in central Alabama, less than 2% of PM10-2.5 at an urban site in Georgia, and less than 10% of PM10-2.5 at an urban-industrial site in Alabama. Manual scanning electron microscopy (SEM) and computer-controlled SEM (CCSEM) along with energy dispersive X-ray spectroscopy (EDS) were used to identify individual carbonaceous particles in a selected subset of samples collected at one rural site and one urban-industrial site in Alabama. CCSEM results showed that biological material (e.g., fungal spores, pollen, and vegetative detritus) accounted for 60-70% of the carbonaceous mass in PM10-2.5 samples with concentrations in the range of 2-16 {mu}g/m{sup 3}. Samples with higher PM10-2.5 concentrations (25-42 {mu}g/m{sup 3}) at the urban-industrial site were found by manual SEM to have significant amounts of unidentified carbonaceous material, likely originating from local industrial activities. Both filter-based OC and EC concentrations and SEM-identified biological material tended to have higher concentrations during warmer months. Upper limits for organic mass (OM) to OC ratios (OM/OC) are estimated for PM10-2.5 samples at 2.1 for urban sites and 2.6-2.7 for rural sites. 40 refs., 12 figs., 5 tabs.

01 COAL, LIGNITE, AND PEAT↗

Control of matrix converters using machine learning

A method of controlling a matrix converter system is provided. The method includes receiving an operating condition and consulting a trained Q-data structure for reward values associated with respective switching states of the switching matrix for an operating state that corresponds to the operating condition. The Q-data structure is trained using Q-learning to map a reward value predicted for respective switching states to respective discrete operating states. The method further includes sorting the reward values predicted for the respective switching states mapped to the operating state that corresponds to the operating condition, selecting a subset of the set of the mappings as a function of a result of sorting the reward values associated with the switching states of the operating state, evaluating each switching state included in the subset, and selecting an optimal switching state for the operating condition based on a result of evaluating the switching states of the subset.

Chamie, Mahmoud El↗

Mass Spectrometry Adduct Calculator

We describe the Mass Spectrometry Adduct Calculator (MSAC), an automated Python tool to calculate the adduct ion masses of a parent molecule. Here, adduct refers to a version of a parent molecule [M] that is charged due to addition or loss of atoms and electrons resulting in a charged ion, e.g. [M+H] + . MSAC includes a database of 2,341 potential ions and their mass-to-charge ratios (m/z) as extracted from the NIST/EPA/NIH Mass Spectral Library (NIST17), the Global Natural Products Social Molecular Networking Public Spectral Libraries (GNPS), and MassBank of North America (MoNA). The calculator relies on user-selected subsets of the combined database to calculate expected m/z for adducts of molecules supplied as formulas This tool is intended to help researchers create identification libraries to collect evidence for the presence of molecules in mass spectrometry data. While the included adduct database focuses on adducts typically detected during liquid chromatography-mass spectrometry analyses, users may supply their own lists of adducts and charge states for calculating expected m/z. We also analyzed statistics on adducts from spectra contained in the three selected mass spectral libraries. MSAC is freely available at https://github.com/pnnl/MSAC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

RegPrecise 3.0 – A resource for genome-scale exploration of transcriptional regulation in bacteria

Background: Genome-scale prediction of gene regulation and reconstruction of transcriptional regulatory networks in prokaryotes is one of the critical tasks of modern genomics. Bacteria from different taxonomic groups, whose lifestyles and natural environments are substantially different, possess highly diverged transcriptional regulatory networks. The comparative genomics approaches are useful for in silico reconstruction of bacterial regulons and networks operated by both transcription factors (TFs) and RNA regulatory elements (riboswitches). Description: RegPrecise (http://regprecise.lbl.gov) is a web resource for collection, visualization and analysis of transcriptional regulons reconstructed by comparative genomics. We significantly expanded a reference collection of manually curated regulons we introduced earlier. RegPrecise 3.0 provides access to inferred regulatory interactions organized by phylogenetic, structural and functional properties. Taxonomy-specific collections include 781 TF regulogs inferred in more than 160 genomes representing 14 taxonomic groups of Bacteria. TF-specific collections include regulogs for a selected subset of 40 TFs reconstructed across more than 30 taxonomic lineages. Novel collections of regulons operated by RNA regulatory elements (riboswitches) include near 400 regulogs inferred in 24 bacterial lineages. RegPrecise 3.0 provides four classifications of the reference regulons implemented as controlled vocabularies: 55 TF protein families; 43 RNA motif families; ~150 biological processes or metabolic pathways; and ~200 effectors or environmental signals. Genome-wide visualization of regulatory networks and metabolic pathways covered by the reference regulons are available for all studied genomes. A separate section of RegPrecise 3.0 contains draft regulatory networks in 640 genomes obtained by an conservative propagation of the reference regulons to closely related genomes. Conclusions: RegPrecise 3.0 gives access to the transcriptional regulons reconstructed in bacterial genomes. Analytical capabilities include exploration of: regulon content, structure and function; TF binding site motifs; conservation and variations in genome-wide regulatory networks across all taxonomic groups of Bacteria. RegPrecise 3.0 was selected as a core resource on transcriptional regulation of the Department of Energy Systems Biology Knowledgebase, an emerging software and data environment designed to enable researchers to collaboratively generate, test and share new hypotheses about gene and protein functions, perform large-scale analyses, and model interactions in microbes, plants, and their communities.

59 BASIC BIOLOGICAL SCIENCES↗

Reducing I/O variability using dynamic I/O path characterization in petascale storage systems

In petascale systems with a million CPU cores, scalable and consistent I/O performance is becoming increasingly difficult to sustain mainly because of I/O variability. Furthermore, the I/O variability is caused by concurrently running processes/jobs competing for I/O or a RAID rebuild when a disk drive fails. We present a mechanism that stripes across a selected subset of I/O nodes with the lightest workload at runtime to achieve the highest I/O bandwidth available in the system. In this paper, we propose a probing mechanism to enable application-level dynamic file striping to mitigate I/O variability. We also implement the proposed mechanism in the high-level I/O library that enables memory-to-file data layout transformation and allows transparent file partitioning using subfiling. Subfiling is a technique that partitions data into a set of files of smaller size and manages file access to them, making data to be treated as a single, normal file to users. Here, we demonstrate that our bandwidth probing mechanism can successfully identify temporally slower I/O nodes without noticeable runtime overhead. Experimental results on NERSC’s systems also show that our approach isolates I/O variability effectively on shared systems and improves overall collective I/O performance with less variation.

97 MATHEMATICS AND COMPUTING↗

Molecular imaging to guide systemic cancer therapy: Illustrative examples of PET imaging cancer biomarkers

Molecular imaging agents have the ability to non-invasively visualize, characterize, and quantify the molecular biology of disease. Recent advances in nuclear probe development, particularly in PET radiotracers, have generated many new imaging agents with precise molecular targets. With such specificity, PET probes may be utilized as biomarkers to objectively interrogate and evaluate pathology. Whereas the current indications for PET imaging are predominately confined to staging and restaging of malignancy, the utility of PET greatly expands when utilized as a biomarker, the topic of this review. As an imaging biomarker, PET may be used to (1) measure target expression to select subsets of patients who would most benefit from targeted therapy; (2) measure early treatment response to predict therapeutic efficacy; and (3) relate tumor response to survival. This work will discuss the application of radiotracers to targeted cancer therapy. Particular attention is given to new radiotracers evaluated in recently completed clinical trials and those with current or potential clinical utility. The diverse roles of PET in clinical trails for drug development are also examined.

62 RADIOLOGY AND NUCLEAR MEDICINE↗