At least 55 records · Page 3

Freeing Water from Viruses and Bacteria

Four years ago, Argonide Corporation, a company focused on the research, production, and marketing of specialty nano materials, was seeking to develop applications for its NanoCeram[R] fibers. Only 2 nanometers in diameter, these nano aluminum oxide fibers possessed unusual bio-adhesive properties. When formulated into a filter material, the electropositive fibers attracted and retained electro-negative particles such as bacteria and viruses in water-based solutions. This technology caught the interest of NASA as a possible solution for improved water filtration in space cabins. NASA's Johnson Space Center awarded Sanford, Florida-based Argonide a Phase I Small Business Innovation Research (SBIR) contract to determine the feasibility of using the company's filter for purifying recycled space cabin water. Since viruses and bacteria can be carried aboard space cabins by space crews, the ability to detect and remove these harmful substances is a concern for NASA. The Space Agency also desired an improved filter to polish the effluent from condensed and waste water, producing potable drinking water. During its Phase I partnership with NASA, Argonide developed a laboratory-size filter capable of removing greater than 99.9999 percent of bacteria and viruses from water at flow rates more than 200 times faster than virus-rated membranes that remove particles by sieving. Since the new filter s pore size is rather large compared to other membranes, it is also less susceptible to clogging by small particles. In September 2002, Argonide began a Phase II SBIR project with Johnson to develop a full-size cartridge capable of serving a full space crew. This effort, which is still ongoing, enabled the company to demonstrate that its filter media is an efficient absorbent for DNA and RNA.

Source record↗

Microfluidic Devices for Studying Biomolecular Interactions

Microfluidic devices for monitoring biomolecular interactions have been invented. These devices are basically highly miniaturized liquid-chromatography columns. They are intended to be prototypes of miniature analytical devices of the laboratory on a chip type that could be fabricated rapidly and inexpensively and that, because of their small sizes, would yield analytical results from very small amounts of expensive analytes (typically, proteins). Other advantages to be gained by this scaling down of liquid-chromatography columns may include increases in resolution and speed, decreases in the consumption of reagents, and the possibility of performing multiple simultaneous and highly integrated analyses by use of multiple devices of this type, each possibly containing multiple parallel analytical microchannels. The principle of operation is the same as that of a macroscopic liquid-chromatography column: The column is a channel packed with particles, upon which are immobilized molecules of the protein of interest (or one of the proteins of interest if there are more than one). Starting at a known time, a solution or suspension containing molecules of the protein or other substance of interest is pumped into the channel at its inlet. The liquid emerging from the outlet of the channel is monitored to detect the molecules of the dissolved or suspended substance(s). The time that it takes these molecules to flow from the inlet to the outlet is a measure of the degree of interaction between the immobilized and the dissolved or suspended molecules. Depending on the precise natures of the molecules, this measure can be used for diverse purposes: examples include screening for solution conditions that favor crystallization of proteins, screening for interactions between drugs and proteins, and determining the functions of biomolecules.

Wilson, Wilbur W.↗

Fueling the Future: The Emergence of Self-Powered Enzymatic Biofuel Cell Biosensors

Self-powered biosensors are innovative devices that can detect and analyze biological or chemical substances without the need for an external power source. These biosensors can convert energy from the surrounding environment or the analyte itself into electrical signals for sensing and data transmission. The self-powered nature of these biosensors offers several advantages, such as portability, autonomy, and reduced waste generation from disposable batteries. They find applications in various fields, including healthcare, environmental monitoring, food safety, and wearable devices. While self-powered biosensors are a promising technology, there are still challenges to address, such as improving energy efficiency, sensitivity, and stability to make them more practical and widely adopted. This review article focuses on exploring the evolving trends in self-powered biosensor design, outlining potential advantages and limitations. With a focal point on enzymatic biofuel cell power generation, this article describes various sensing mechanisms that employ the analyte as substrate or fuel for the biocatalyst’s ability to generate current. Technical aspects of biofuel cells are also examined. Research and development in the field of self-powered biosensors is ongoing, and this review describes promising areas for further exploration within the field, identifying underexplored areas that could benefit from further investigation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The fluorescence of chlorophyll and yellow substances in natural waters: A note on the problems of measurement and the importance of their remote sensing

There are two chromophylls which, if sensed remotely from high altitude, would revolutionize the ability to survey large areas of the world's oceans. The chromophylls of importance are: the photosynthetic pigments of plankton algae and a group of organic materials frequently termed dissolved yellow substances. These are derived from plants and carried into the ocean by fresh water inflow. The attenuation of light by phytoplankton is characterized by two distinctive bands (450, 675 nm) which represent absorption by chloroplastic pigments. Yellow substances are characterized by a strong ultraviolet absorption which tails over into the visible region. It is emphasized that chlorophyll determination could be a unique technique for estimating the extent of eutrophication in coastal waters, and that a high altitude observer equipped with temperature, chlorophyll and yellow substance sensors has the possibility of detecting the magnitude of eutrophication and its sources by using laser induced fluorescent devices.

Yentsch, C. S.↗

Simple Test For Organic Material In Gas

Dried enzymes and color indicators test sensitively and selectively. Dehydrated enzymes used in convenient method for analyzing gases for specific organic substances, outside laboratory. Method used to detect alcohol in breath or formaldehyde in gas streams. Used for simple semiquantitative detection or for precise quantitative measurement.

Barzana, Eduardo↗

Lab-scale Lidar Sensing of Diesel Engines Exhausts

Combustion technology and its environmental concerns are being considered with increasing attention, not only for global-scale effects, but also for toxicological implications, particularly in the lift conditions of traffic-congested areas and industrial sites. Majority combustion by-products (CO, NO(sub x)) and unburned hydrocarbons (HC), are already subject to increasingly severe regulations; however other, non-regulated minority species, mainly soot and heavy aromatic molecules, involve higher health risks, as they are suspected to be agents of serious pathologies and even mutagenic effects. This is but one of the reasons why much research work is being carried out worldwide on the physical properties of these substances. Correspondingly, the need arises to detect their presence in urban environments, with as high a sensitivity as is required by their low concentrations, proper time- and space-resolutions, and 'real-time' capabilities. Lidar techniques are excellent candidates to this purpose, although severe constraints limit their applicability, eye-safety problems and aerosol Mie scattering uncertainties above all. At CNR's Istituto Motori in Napels, a Lidar-like diagnostic system is being developed, aimed primarily at monitoring the dynamic behavior of internal combustion engines, particularly diesel exhausts, and at exploring the feasibility of a so-called 'Downtown Lidar'.

Borghese, A.↗

Changes in Black Carbon Deposition to Antarctica from Two Ice Core Records, A.D. 1850-2000

Continuous flow analysis was based on a steady sample flow and in-line detection of BC and other chemical substances as described in McConnell et al. (2007). In the cold room, previously cut one meter ice core sticks of 3x3cm, are melted continuously on a heated melter head specifically designed to eliminate contamination from the atmosphere or by the external parts of the ice. The melted ice from the most inner part of the ice stick is continuously pumped by a peristaltic pump and carried to a clean lab by Teflon lines. The recorded signal is continuous, integrating a sample volume of about 0.05 mL, for which the temporal resolution depends on the speed of melting, ice density and snow accumulation rate at the ice core drilling site. For annual accumulation derived from the WAIS and Law Dome ice cores, we assumed ~3.1 cm water equivalent uncertainty in each year's accumulation from short scale spatial variability (glaciological noise) which was determined from several measurements of annual accumulation in multiple parallel ice cores notably from the WAIS Divide ice core site (Banta et al., 2008) and from South Pole site (McConnell et al., 1997; McConnell et al., 2000). Refractory black carbon (rBC) concentrations were determined using the same method as in (Bisiaux et al., 2011) and adapted to continuous flow measurements as described by (McConnell et al., 2007). The technique uses a single particle intracavity laser induced incandescence photometer (SP2, Droplet Measurement Technologies, Boulder, Colorado) coupled to an ultrasonic nebulizer/desolvation (CETAC UT5000) Flow Injection Analysis (FIA). All analyses, sample preparation etc, were performed in a class 100 cleanroom using anti contamination "clean techniques". The samples were not acidified.

Bisiaux, Marion M.↗

Atomically Precise Hexanuclear Ce(IV) Clusters as Functional Fluorescent Nanosensors for Rapid One-Step Detection of PFAS

Here, the presence of poly- and perfluoroalkyl substances (PFAS) in the environment is associated with adverse health effects but measuring PFAS is challenging due to the associated high cost and technical complexities of the analysis. Here, the reactivity of atomically precise metal-oxo clusters is reported and the foundation for their use is provided as fluorescent nanosensors for PFAS detection. The material comprises crystalline, water soluble, hexanuclear cerium-oxo clusters [Ce 6 (µ 3 -O) 4 (µ 3 -OH) 4 ] 12+ decorated with glycine molecules (Ce-Gly) characterized by fluorescence emission at 353 nm. The Ce-Gly fluorescence is found sensitive to long chain carboxylated PFAS of CF 3 –(CF 2 ) n –, where n ≥ 6, such as perfluorooctanoic, perfluorononanoic and perfluorodecanoic acids. This unique reactivity leads to a change in the emission spectra in a concentration dependent manner, enabling PFAS detection through ligand exchange and aggregation-induced emission (AIE) enhancement. No significant cross-reactivity from potentially co-existing species, including sulfonated PFAS, octanoic and dodecanoic acids, humic acid, and inorganic ions is observed. With an optimal concentration of 3.3 µg mL -1 Ce-Gly, the method demonstrated detection limits of 0.24 ppb for PFOA and 0.4 ppb for PFNA. These findings highlight the potential of fluorescence-based detection strategies utilizing nanoscale probes such as Ce-Gly as fluorescent probes and nanosensors for PFAS.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

PFAS remediation: Evaluating the infrared spectra of complex gaseous mixtures to determine the efficacy of thermal decomposition of PFAS

Due to their widespread production and known environmental contamination, the need for the detection and remediation of per- and polyfluoroalkyl substances (PFAS) has grown quickly. While destructive thermal treatment of PFAS at low temperatures (e.g., 200 to 500oC) is of interest due to lower energy and infrastructure requirements, the range of possible degradation products remains underexplored. To better understand the low temperature decomposition of PFAS species, we have coupled gas-phase infrared spectroscopy with a multivariate curve resolution (MCR) analysis and a database of high-resolution PFAS infrared reference spectra to detect and quantify a complex mixture resulting from potassium perfluorooctanesulfonate (PFOS-K) decomposition. Nine prevalent decomposition products (namely smaller perfluorocarbon species) are identified and quantified.

54 ENVIRONMENTAL SCIENCES↗

Low Cost Solar Array Project: Composition Measurements by Analytical Photo Catalysis

The applicability of the photon catalysis technique for effecting composition analysis of silicon samples is discussed. A detector for the impurities Al, Cr, Fe, Mn, Ti, V, Mo and Zr is evaluated. During the first reporting period Al, Cr, Fe, and Mn were detected with the photon catalysis method. The best fluorescence lines to monitor and determine initial sensitivities to each of these elements by atomic absorption calibration were established. In the course of these tests vapor pressure curves for these four pure substances were also mapped. Ti and Si were detected. The best lines to monitor were catalogued and vapor pressure curves were determined. Attempts to detect vanadium were unsuccessful due to the refractory nature of this element and the limited temperature range of the evaporator.

Sutton, D. G.↗

Reversible parts-per-trillion-level detection of perfluorooctane sulfonic acid in tap water using field-effect transistor sensors

Widespread, persistent and toxic per- and polyfluoroalkyl substances (PFAS) pose a major threat to water systems and human health. Current detection methods are relatively expensive, slow and complex, underscoring the need for more accessible alternatives to meet increasingly stringent PFAS regulations. Here, in this study, we present an ultrasensitive sensing platform for perfluorooctane sulfonic acid detection in tap water with a reporting limit ( ~ 250 parts per quadrillion) lower than the US Environmental Protection Agency’s regulatory standard (4 parts per trillion), using a remote gate field-effect transistor featuring β-cyclodextrin (β-CD)-modified reduced graphene oxide as the sensing membrane. The sensor exhibits excellent selectivity against common inorganic ions, natural organic matter and select organic pollutants in tap water. The reversible and rapid response ( < 2 min) indicates the potential of remote gate field-effect transistor for continuous in-line monitoring. Mechanistic studies using quartz crystal microbalance and molecular dynamics simulations reveal key roles of analyte adsorption and charge properties in sensing performance and offer insights for designing more selective PFAS capture probes.

Wang, Yuqin [University of Chicago, IL (United Sta↗

Remote detection of ocean waste

An application of characteristic vector analysis to ocean color spectra for the detection of pollutants in water is described. The technique can be useful for detecting and distinguishing among a variety of substances in the water. The analysis also illustrates the variability of the water color spectra with both concentration and depth distribution. Both concentration and depth information may be extractable from passive multispectral data under certain circumstances.

Philpot, W. D.↗

Applications of the Strategic Defense Initiative's compact accelerators

The Strategic Defense Initiative's (SDI) investment in particle accelerator technology for its directed energy weapons program has produced breakthroughs in the size and power of new accelerators. These accelerators, in turn, have produced spinoffs in several areas: the radio frequency quadrupole linear accelerator (RFQ linac) was recently incorporated into the design of a cancer therapy unit at the Loma Linda University Medical Center, an SDI-sponsored compact induction linear accelerator may replace Cobalt-60 radiation and hazardous ethylene-oxide as a method for sterilizing medical products, and other SDIO-funded accelerators may be used to produce the radioactive isotopes oxygen-15, nitrogen-13, carbon-11, and fluorine-18 for positron emission tomography (PET). Other applications of these accelerators include bomb detection, non-destructive inspection, decomposing toxic substances in contaminated ground water, and eliminating nuclear waste.

Montanarelli, Nick↗

Toxicological evaluation of the Columbia spacecraft

The toxicology procedures developed for the Space Shuttle program to evaluate and eliminate contaminants in the cabin atmosphere characterized, and results from STS missions 1-5 are reviewed. Shuttle maximum-allowable-concentration standards (SMAC) equal to 10-50 percent of those established for normal 40-h work weeks on the ground have been established for a broad range of substances, and outgassing data are employed in choosing spacecraft construction materials. Gases are removed by the atmospheric revitalization system (CO2-removal bed, catalytic oxidizer, and dehumidifier). Whole-gas and adsorbed-gas samples are employed in ground-based and inflight measurements of contaminants: results are presented in tables. A total of 152 substances, of which 64 were well defined, were detected in STS-1-5. Only the toluene contamination on STS-2 (17 ppm compared to the SMAC of 20 ppm) was considered serious.

Rippstein, W. J., Jr.↗

Genetic toxicity studies of organic chemicals found as contaminants in spacecraft cabin atmospheres

Astronauts can be exposed during spaceflight to organic chemical contaminants in the spacecraft cabin atmosphere. Toxic exposures may cause lesions in the cellular DNA which are subsequently expressed as sister-chromatid exchanges (SCE). Analysis of SCE is a sensitive short term assay techinque to detect and quantitate exposures to DNA damaging (mutagenic) substances. The increase in SCE incidence over baseline (control) levels is generally proportional to the concentration of the mutagen and to the duration of exposure. The BHK-21 baby hamster kidney cell line was the in vitro test system used. Test organics were added to the culture media for 18 hrs, in concentrations ranging from one to 20 ppm. Acetaldehyde and carbon disulfide were chosen for this study since they have occurred as atmospheric contaminants in many of the STS flights, and have been reported to have toxic and mutagenic effects in various test systems. Glutaraldehyde was chosen because few data are available on the mutagenicity of this common fixative, which is carried on STS flights for use in biological experiments. Acetaldehyde was a very strong inducer of SCE at concentrations of 2 ppm and above. Glutaraldehyde and carbon disulfide failed to induce SCE.

Torres, Joseph, Jr.↗

Aerosol particles in the upper troposphere and lower stratosphere: Elemental composition and morphology of individual particles in northern midlatitudes

Atmospheric particles were collected in the midlatitude upper troposphere (UT) and lower stratosphere (LS) by inetrial impaction for subsequent electron microscopy and individual particle element analysis. More than 97% of particles analyzed on impactor substrates exposed in the LS contained only O and S in detectable quantities; these particles are believed to be acidic sulfate. Nonsulfate materials seen in the remaining particles included soot, other c-rich substances and crustal materials. Although not predominantly sulfate, usually carried a sulfer-rich coating in the LS. Samples collected very near and just below the tropopause were also dominated by sulfates. The fraction of sulfate particles analyzed on impactor substrates exposed in the UT was 91-94% of the total particle concentration. Nonsulfate substances observed in the UT samples included crustal-type material, hydrated marine salts, carbon-rich materials of several types, and metal-containing substances of uncertain origin. Most of these UT particles were not coated with detectable quantitites of sulfate.

Sheridan, Patrick J.↗

WGM-Based Photonic Local Oscillators and Modulators

Photonic local oscillators and modulators that include whispering-gallery mode (WGM) optical resonators have been proposed as power-efficient devices for generating and detecting radiation at frequencies of the order of a terahertz. These devices are intended especially to satisfy anticipated needs for receivers capable of detecting lowpower, narrow-band terahertz signals to be used for sensing substances of interest in scientific and military applications. At present, available terahertz-signal detectors are power-inefficient and do not afford the spectral and amplitude resolution needed for detecting such signals. The proposed devices would not be designed according to the conventional approach of direct detection of terahertz radiation. Instead, terahertz radiation would first be up-converted into the optical domain, wherein signals could be processed efficiently by photonic means and detected by optical photodetectors, which are more efficient than are photodetectors used in conventional direct detection of terahertz radiation. The photonic devices used to effect the up-conversion would include a tunable optical local oscillator and a novel electro-optical modulator. A local oscillator according to the proposal would be a WGM-based modelocked laser operating at a desired pulserepetition rate of the order of a terahertz. The oscillator would include a terahertz optical filter based on a WGM microresonator, a fiber-optic delay line, an optical amplifier (which could be either a semiconductor optical amplifier or an erbium-doped optical fiberamplifier), and a WGM Ka-band modulator. The terahertz repetition rate would be obtained through harmonic mode locking: for example, by modulating the light at a frequency of 33 GHz and locking each 33d optical mode, one would create a 1.089-THz pulse train. The high resonance quality factors (Q values) of WGM optical resonators should make it possible to decrease signal-generation threshold power levels significantly below those of other optical-signal-generation devices.

Matsko, Andrey↗

A quarantine protocol for analysis of returned extraterrestrial samples

A protocol is presented for the analysis at an earth-orbiting quarantine facility of return samples of extraterrestrial material that might contain (nonterrestrial) life forms. The protocol consists of a series of tests designed to determine whether the sample, conceptualized as a 1-kg sample of Martian soil, is free from nonterrestrial biologically active agents and so may safely be sent to a terrestrial containment facility, or it exhibits biological activity requiring further (second-order) testing outside the biosphere. The first-order testing procedure seeks to detect the presence of any replicating organisms or toxic substances through a series of experiments including gas sampling, analysis of radioactivity, stereomicroscopic inspection, chemical analysis, microscopic examination, the search for metabolic products under growth conditions, microbiologicl assays, and the challenge of cultured cells with any agents found or with the extraterrestrial material as is. Detailed plans for the second-order testing would be developed in response to the actual data received from primary testing.

Bagby, J. R.↗